Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹11.0 LQualified Make: KOEL GREEN GFE
Model: KOEL GREEN /KIRLOSKAR HA 394TCIG1 SCO 36 SECTOR 26 CHANDIGARH 160 019 CHANDIGARH CHANDIGARH CHANDIGARH 160019 | CHANDIGARH | CHANDIGARH | 160019 | Make: KOEL GREEN GFE
Model: KOEL GREEN /KIRLOSKAR HA 394TCIG1 | L1 | Qualified | |
| 2 | Disqualified Make: KOEL GREEN GFE
Model: KOEL GREEN /KIRLOSKAR HA 394TCIG1 1 A BUILDING NO 1231 DAYANAND COLONY NEAR SECTOR 4 GURGAON HARYANA 122001 | GURUGRAM | HARYANA | 122001 | Make: KOEL GREEN GFE
Model: KOEL GREEN /KIRLOSKAR HA 394TCIG1 | - | Disqualified | |
| 3 | Disqualified Make: MAHINDRA - GSP
Model: MM3320SIT-T-C2 B 2 16 MOHAN COOPERATIVE INDUSTRIAL ESTATE BADARPUR BORDER NEW DELHI SOUTH DELHI DELHI 110044 | SOUTH EAST DELHI | DELHI | 110044 | Make: MAHINDRA - GSP
Model: MM3320SIT-T-C2 | - | Disqualified | |
| 4 | Disqualified Make: ICON POWER
Model: Eicher Engine & 422 ES 6A LGF KHASRA NO 117 1 2 RAJPUR KHURD EXTENSION COLONY NEW DELHI DELHI 110068 | SOUTH DELHI | DELHI | 110068 | Make: ICON POWER
Model: Eicher Engine & 422 ES | - | Disqualified | |
| 5 | Disqualified Make: EICHER ENGINES JAYCEE
Model: EICHER ENGINES JAYCEE & JPS/3203A 13 6 MATHURA ROAD NH 2 FARIDABAD HARYANA 121003 | FARIDABAD | HARYANA | 121003 | Make: EICHER ENGINES JAYCEE
Model: EICHER ENGINES JAYCEE & JPS/3203A | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
26 Sept 2018, 9:00 amClosed
Diesel Generators- DG Sets ( 3 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 20 * (or higher) No of Phase - Single phase
Three Phase ENGINE Make of Engine - * Model Number of Engine - * Capacity of Engine (cc) - * Engine Power (kWm) - * ISI Marking to IS :10001 for engine false * Type of Engine cooling Air Cooled Air Cooled
Liquid Cooled Type of governer Mechanical Mechanical
Electronic (or higher) Class of governer A2 A0
A1
A2 (or higher) Number of cylinders 3 * 1/4 (nos) No of Strokes (nos) 4 * Rated RPM of Engine (RPM) - 1500
3000 Overload capacity for one hour for every 11 hours continuous running at full load (%) 1 * Specific Fuel Consumption (gm/kWh) - * Starting voltage (volt) 12 * ALTERNATOR AC GENERATOR(ALTER NATOR) Make - * AC GENERATOR(ALTER NATOR) model Number - * Rating of AC Generator (KVA) 20 * Power Factor of AC generator 0.8 * Efficiency at rated Power factor at 75% of full Load 91.6 * Compliance of Alternator to IS:13364(part-1) Yes * Type of alternator Brushless * Voltage Regulation Grade VG 3 * Alternator IP Rating IP 23 * Class of Insulation H * CONTROL PANEL Control Panel Manual Manual
AMF IP Rating of Control Panel IP 53 * ACOUSTIC ENCLOSURE Sheet Thickness 1.6 1.6
1.8
2
1.2 (or higher) Thickness of Foam 20 * Density of Foam for sound insulation 28 * Noise level at 1 meter (dB) 75 * BATTERY Battery Type & Specification Low Maintenance free to IS: 14257 for high cranking performance * Battery capacity (Ah) - * 2/4 No of batteries 1 * TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes * Test Report number and date(Engine) - * Name and address of laboratory(Engine) - * Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes * Test Report number and date(Alternator) - * Name and address of laboratory(Alternator) - * DG set meet requirements of Enviro nmental(Protection) Rules 1986
in respect of noise and emission norms
as described in STC Yes * WARRANTY INSTALLATION & COMMISSIONING Warranty 1 Any applicable numeric value Installation & Commissioning Without Installation With Installation
Without Installation Agreed to STC of the Product Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 SUDHANSHU GUPTA 191111
Near Degree College 3 15
634033
GEM/2018/B/89991
diesel generators- DG Sets
15 days
Jammu And Kashmir; Budgam
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Diesel Generators- DG Sets ( 3 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 20 * (or higher) No of Phase - Single phase | - | - | - |
| Three Phase ENGINE Make of Engine - * Model Number of Engine - * Capacity of Engine (cc) - * Engine Power (kWm) - * ISI Marking to IS :10001 for engine false * Type of Engine cooling Air Cooled Air Cooled | - | - | - |
| Liquid Cooled Type of governer Mechanical Mechanical | - | - | - |
| Electronic (or higher) Class of governer A2 A0 | - | - | - |
| A1 | - | - | - |
| A2 (or higher) Number of cylinders 3 * 1/4 (nos) No of Strokes (nos) 4 * Rated RPM of Engine (RPM) - 1500 | - | - | - |
| 3000 Overload capacity for one hour for every 11 hours continuous running at full load (%) 1 * Specific Fuel Consumption (gm/kWh) - * Starting voltage (volt) 12 * ALTERNATOR AC GENERATOR(ALTER NATOR) Make - * AC GENERATOR(ALTER NATOR) model Number - * Rating of AC Generator (KVA) 20 * Power Factor of AC generator 0.8 * Efficiency at rated Power factor at 75% of full Load 91.6 * Compliance of Alternator to IS:13364(part-1) Yes * Type of alternator Brushless * Voltage Regulation Grade VG 3 * Alternator IP Rating IP 23 * Class of Insulation H * CONTROL PANEL Control Panel Manual Manual | - | - | - |
| AMF IP Rating of Control Panel IP 53 * ACOUSTIC ENCLOSURE Sheet Thickness 1.6 1.6 | - | - | - |
| 1.8 | - | - | - |
| 2 | - | - | - |
| 1.2 (or higher) Thickness of Foam 20 * Density of Foam for sound insulation 28 * Noise level at 1 meter (dB) 75 * BATTERY Battery Type & Specification Low Maintenance free to IS: 14257 for high cranking performance * Battery capacity (Ah) - * 2/4 No of batteries 1 * TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes * Test Report number and date(Engine) - * Name and address of laboratory(Engine) - * Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes * Test Report number and date(Alternator) - * Name and address of laboratory(Alternator) - * DG set meet requirements of Enviro nmental(Protection) Rules 1986 | - | - | - |
| in respect of noise and emission norms | - | - | - |
| as described in STC Yes * WARRANTY INSTALLATION & COMMISSIONING Warranty 1 Any applicable numeric value Installation & Commissioning Without Installation With Installation | - | - | - |
| Without Installation Agreed to STC of the Product Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 SUDHANSHU GUPTA 191111 | - | - | - |
| Near Degree College 3 15 | - | - | - |
Exempted
26 Sept 2018
26 Sept 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_634033.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .