Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.4 LAccepted-AOC | L1 | Accepted-AOC L1 Accepted | |
| 2 | L2₹19.0 L+₹20,153 (1.07%)Rejected-AOC | L2 | Rejected-AOC Other than L1 |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
4 Dec 2023, 6:00 pmClosed
GE( N) Akhnoor
GE( N) Akhnoor PIN 181201 C/O 56 APO
CLEANING AND DESLUDGING OF MANHOLES SEPTIC TANKS SEWAGE LINES INCLUDING MISC B/R TO GUARD ROOM SANTRY POST IN NORTH ZONE AREA AT AKHNOOR UNDER GE (NORTH) AKHNOOR
2023_MES_626198_1
CANO- GE(N)/AKH-46/2023-2024
Open Tender
Support/Maintenance Service
Item Rate
180 days
Akhnoor
Class D cat a i
9 documents required · 9 mandatory
₹500
Yes
GE (N) Akhnoor
₹54,000
15 Feb 2024
1 Nov 2023
11 Dec 2023
1 Nov 2023
4 Dec 2023
15 Nov 2023
Amount
Demolition of reinforced cement concrete of any description and in any position including cutting reinforcement as required to facilitate complete all as specified and directed.
Pre cast reinforced cement concrete 1:2:4 type B1 (using 20mm graded crushed stone aggregates) as in manhole cover slabs including use and waste of necessary formwork complete all as specified and directed.
TMT Bar 8mm dia bar and over cut to length, bent to shape required including cranking, bending, hooking ends, binding, with and including mild steel wire (annealed) not less than steel wire 0.9mm dia or securing with clips, complete all as specified and directed.
Demolition of brick work or stone masonary built in cement mortar including all quions, arches , pillars etc. complete all as specified and directed.
Brick work with sub class 'B' bricks , straight or curved on plan exc. 6 mtr mean radius built in CM 1:6 complete all as specified and directed.
Rendering 15mm thick cement plaster with cement mortar(1:4) on fair faces of brick work or concrete surfaces and finishing the surface even and smooth without using extra cement complete all as specified and directed.
PCC 1:2:4 type B-0 (Using 12.5mm graded crushed stone aggregates) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles including necessary form work complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out etc in any type of soil, complete all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar of 150 mm diameter incl bends, complete all as specified and directed.
RCC class NP3 150mm dia drain pipes laid in trenches and jointed with & including coller complete all as specified and directed.
Concrete bed to drain pipes 1:3:6 type C-2 (Using 40mm graded crushed stone aggregate) including packing under and haunching against the side of pipes after they are laid and tested for 150mm internal dia of pipe, complete all as specified and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specified and directed.
Removing excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point, complete all as specified and directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cementt concrete 1:2:4 type B-1 smooth finished, and reforming benching as required, internal dia of pipe in 150mm, complete all as specified and directed.
Cleaning of sewage line 150mm/200mm internal dia at any depth including manholes by removing the manhole covers of any size and cleaning by means of hydraulic jet pressure / vaccum suction machine as required at site from and well flushing with water after cleaning including getting out sludge if any and liquid materials from connecting manholes deposited in sewer lines removing the solids and sludge to any distance/place outside the defence land and reinstating the manhole cover to its original position (cost of removal of sludge/liquid materials from sewage lines and manholes in the same line is included in the rate quoted and for keeping particular sewage line which is undertaken once for cleaning, functional for full contract period) complete all as specified and directed.
Taking out/pumping contaminated sewage water from septic tank/soakage well incl inlet/outlet chamber after plugging in the incoming sewage line by suction(vaccum) type machine mounted on LMV/HMV and facility of high pressure vaccume and removing and dumping off the same in tank to a place out side contonment at the place marked for the purpose by local municipality or the authority controling the area as directed by Engr-in-charge. Note :- contractors are advised to ascertain the place suitable/earmarked for disposal of sludge/sewage water from local municipality or area controling authority before quoting their rates. Disposal of waste at suitable place shall be sole responsibility of contractors and no representation or objection in this regard will be entertained at any later stage.
Labour for cleaning of spot blockage of WC seat, manholes, gully traps, floor traps, vertical soils/waste pipe of different dia and sewage line in the area of Akhnoor Mil Stn, complete all as specified and directed. Note- The labour deployed will report daily 08:45hrs at complaint cell and attend complaints till 16:45 hrs given by Engr-in-Charge. Complaints needs to be cleared within 24hrs after receiving. The contractors will supply all T&P (Mechanical iron rods, knot pipes, bamboo etc) scaffolding ladders any other materials required to clear the blockage at the site without any extra cost. Labour for cleaning of sludge from sewage lines (any dia) to manhole is included in quoted rates. The recovery will be made from the contractors dues @100 Rs. per complaint which are not cleared within 24hrs from the time of receipt of complaints. Decision of Engr-in-Charge is final in this respect. Mode of Payment : (i) The payments will be made through AADHAAR linked bank account of the employees by the contractor. Where the employee insists on being paid in coins or currency notes or by cheque, the same will not be denied. An undertaking may be obtained from such employees. However, efforts shall be made to educate the employees on benefits of bank/ digital payments and pursue with the individual(s) to shift towards banking system/digital modes. (ii) The GE/ Engineer-in-Charge being the Principal Employer will have the absolute right to check during site visit that the contractor is complying with the labour laws and rules and should there be any shortcomings, action is taken to rectify the same. GE in the capacity of Principal Employer will have also the right to check payment of minimum fair wages to labourers engaged by contractors by verifying the same from Muster Rolls. No Payment on account of advances on account of work done in terms of Condition 64 of IAFW-2249, General Condition of Contracts shall be admissible unless proof of payment of wages through AADHAAR linked bank account is submitted by the Contractors / Firms. Contd with Srl Item No 17.01
(iii) The Contractor shall be primarily liable for all payments to be made under, and for observance of the Regulations aforesaid without prejudice to his right to claim indemnity from his sub-contractors. The GE/Engineer-in-charge concerned shall have the right to deduct from the payment due to the Contractor, any sum required or estimated to be required for making good the loss suffered by a worker or workers by reason of non-fulfillment of the Conditions of the Contract for the benefit of the workers, non-payment of wages or deduction made from his or their wages, which are not justified by the terms of the contract or non-observance of the Regulations. (iv) The contractor shall be liable for proper maintenance of registers, records, display of notices and ensure enforcement of MES contractors Labour Regulations forming part of the contract and for production of the same during the visit of Labour Welfare Officer/Regional Labour Commissioner. (v) The contractor under information to the GE/Engineer-in-Charge shall take prompt action in rectifying irregularities notified by the Inspecting Officer. In Case of Non-Payment or short payment of fair wages to the workers by the contractor, GE/Engineer-in-Charge shall have the right with prompt action by recovering the amount notified by labour officer and paying the same to workers. Amount of unpaid wages withheld from Contractor's bills should be paid to the labourers concerned within 60 days from receipt, of report from the labour Welfare Officer/ Regional Labour Commissioner. (k) EPF and MP Act 1952 shall be strictly complied with : (i) For the purpose of implementation of the EPF and MP Act 1952, the contractor will ensure that the contractor is registered with FPFO and after award of Contract, the contractor details are entered in the EPFO portal. (ii) Payments due to the contractor shall be made only after verifying that the statutory PF payments have been made to EPFO. This shall be verified by the Govt. either directly from the EPFO portal or insisting on a payment receipt obtained by the contractor from the EPFO portal while making payment.
Removing of manholes cover, keeping aside and cleaning silt/sewage/garbage etc from manholes. clearing blockage by rodding manually or mechanically complete to the entire satisfaction of Engr-in-Charge.
M&L for construction of Septic tanks including excavation in any type soil, foundation in PCC 1:2:4, brick work in CM 1:4, RCC Slab in M-25 Design mix including RCC precast manhole cover with angle iron frame Vent shaft and sludge chambers etc., complete for 25 users, complete all as specified and shown on drg No CE/TD/1202/03 Sheet 1/2 & 2/2.
M&L for construction of Septic tanks including excavation in any type soil, foundation in PCC 1:2:4, brick work in CM 1:4, RCC Slab in M-25 Design mix including RCC precast manhole cover with angle iron frame Vent shaft and sludge chambers etc., complete for 50 users, complete all as specified and shown on drg No CE/TD/1202/03 Sheet 1/2 & 2/2.
M&L for construction of Soakage wells including excavation, in ordinary Soil, foundation in PCC 1:3:6, wells of Honey combed and solid in M-25 Concrete, including intercepting chamber, screen chamber Brick work in CM, RCC cover slab in M-25/ RR masonry / filling with brick bats, complete of size 1.2 M dia X 3.0M deep, complete all as specified and shown on drg No CE/TD/1202/03 Sheet 1/2 & 2/2.
Stop valves cast copper alloy screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions and fixed for 15mm bore dia of pipe in repairs, complete all as specified and directed.
PVC (Plastic polymer Cistern) valve less, Symphonic action type, flushing cistern of capacity 10 litres, low level, white with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length and making connections fixed in repairs, complete all as specified and directed.
Vitreous china wash down water closet pan (pedestal pattern), white, including fixing bolt, plastic water closet seat, white, closed pattern with flat bottom, cover and mild steel chromium plated or aluminium hinging device fixed in repairs, complete all as specified and directed.
Vitreous china squatting pan "Orissa Pattern" size 580 x 440 mm in any coloured with integral foot rest incl lime motor, 'S' trap and complete all as specified, fixed in repairs, complete all as specified and directed. Cat Part No-20042 (ORISSA PAN (ECO)) of Hindware or equivalent cat part of make specified in list make as approved.
Vitreous china urinal half stall flat back, size 465 x 355 x 265 mm, white , complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement; fixing flush pipe, grating and union for discharge pipe fixed in repairs, complete all as specified and directed.
PVC connection 15 mm size with PTMT nuts 600 mm long, complete all as specified and directed.
Stainless steel gratings 100mm dia with hole and fixed with cement motar, complete all as specified and directed.
Vitreous china wash basin, white, flat back, size 550 x 400 mm excluding taps, waste, chain & plug and porcelain stopper but including brackets, waste coupling etc fixed in repairs, complete all as specified and directed. Cat Part No. 10036 of Hindware (Model-Windsor) or its equivalent in Neycer, Cera & Parryware as approved.
Low density PVC waste pipe 32mm bore, 0.90 m long, complete all as specified and directed.
15 mm bore pillar taps, fancy type chromium plated screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe and fixed in repairs, complete all as specified and directed.
Taking down eaves gutters and rain water pipe , soil and waste pipe PVC or CI(any size or pattern ), includding all fittings, heads , shoes bends , swan-necks etc complete all as specified.
110mm bore PVC SWR Type-B (pressure not less than 6 Kg/cm2) pipes single socket in any length with rubber ring joints laid in trenches or in floors etc complete all as specified and directed.
75mm bore PVC SWR Type-B (pressure not less than 6 Kg/cm2) pipes single socket in any length with rubber ring joints laid in trenches or in floors etc all as specified and directed.
PVC SWR Type-B (pressure not less than 6 Kg/cm2) waste pipes/Rain water pipes 110mm dia in any length fixed to walls with PVC//MS holder or clamps complete all as specified and directed.
Description all as srl item No 35 here-in-before, but 75mm bore.
PVC SWR complete bends any radius 110 mm bore with oval access door all as specified.
PVC SWR bends any radius 75mm bore with oval access door complete all as specified.
PVC branch piece, 75 mm double (Y) equal or unequal ordinary or inverted (spigot or socket type) with access door with paralled branches complete all as specified and directed.
PVC branch piece, 110 mm double (Y) equal or unequal ordinary or inverted (spigot or socket type) with access door with parallel branches complete all as specified and directed.
PVC SWR cowls 110mm bore as specified directed.
PVC SWR cowls 75mm bore as complete all as specified and directed.
PVC (SWR) floor trap 75 mm, plain with grating including jointing with solvent cement complete all as specified and directed.
Demolition of Stone slabs and tiles laid bedded and pointed in any mortar of any description or thickness in floors, aprons,walls etc, complete all as specified and directed.
Non skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match including 15 mm thick screed bed in cement and sand mortar 1:6, complete all as specified and directed.
Glazed ceramic coloured tiles 300x450x7mm thick on vertical surfaces such as skirting, dados and rises to steps etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 10mm thick rendering in CM 1:4 on other than fair faces of brick work finished even and fair to receive tiles, complete all as specified and directed.
Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water etc all as specified and as directed.
Rendering 15 mm thick in 1:6 on other than fair faces of brick work or surfaces including finishing the surface even and smooth without using extra cement complete all as specified and as directed.
Rendering 10 mm thick in CM 1:4 on concrete surfaces such as ceiling, soffit or slab etc. including finishing the surface even and smooth without using extra cement complete all as specified and as directed.
Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified and as directed.
Preparation of newly plastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed.
Preparation of newly plastered surfaces of walls and applying two coats of distemper oil emulsion on walls over a coat of primer complete all as specified and as directed.
Complete removal of existing treatment incl washing, rubbing down and stopping of old painted surfaces and applying two coats of cement base paint to walls complete all as specified and as directed.
Complete removal of existing treatment incl washing, rubbing down and stopping of old painted surfaces and applying two coats of oil bound distemper to walls complete all as specified and as directed.
Preparation of old painted surfaces and applying one coat of cement base paint to walls complete all as specified and as directed.
Preparation of old painted surfaces and applying one coat of oil bound distemper on walls complete all as specified and as directed.
Preparation of old painted surfaces and applying one coat of white wash on walls complete all as specified and as directed.
Preparation of old painted surfaces and applying one coat of white wash on ceiling complete all as specified and as directed.
Preparation of old wooden surfaces of any description exc 10 cm width or girth, and applying two coats of synthetic enamel paint complete all as specified and directed.
Preparation of old steel and iron surfaces of any description exc 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level ) complete all as specified and as directed.
25 mm thick PCC 1:2:4 type B-1, (Using 20 mm graded crushed stone aggregate) as in flooring/padding etc of concrete topping even and rough as in levelling cousre complete all as specified.
50mm thick PCC (1:3:6) type C-2 (Using 40mm graded stone aggregate) as in plinth protection laid in bays n.exc 2.00 Sqm complete including finishing the surface of concrete topping even & fair. The joints shall be filled with mastic filling, complete all as specified and as directed.
50 mm thick PCC 1:2:4 type B-1, (Using 20 mm graded crushed stone aggregate), as in flooring/path etc & finishing the surface even and fair complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off premises complete all as specified and as directed.
Non skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match including 15 mm thick screed bed in cement and sand mortar 1:6, complete all as specified and directed.
Non skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.36 Sqm in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match including 15 mm thick screed bed in cement and sand mortar 1:6, complete all as specified and directed.
Description All as per item No 67 here-in-before, but on dado/skirting etc incl 10mm rendering in CM 1:4 complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frames including punching or drilling out old glazing pins/spring clips and providing and fixing new ones glazed with oil putty fixed with beads complete all as specified and directed.
03 mm thick sheet glass, ordinary quality and glazing with oil putty/wooden beads in square not exceeding 0.5 square metre in each pane complete all as specified.
Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of apeture 1.18mm fixed with tinned tacks or galvanised wire staple fixed in repairs complete all as specified.
Machine cut kota stone slab flooring 20-25mm thick laid including jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete as in floor over and including 20mm thick screed bed in CM 1:6 complete all as specified.
150mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked fixed in repairs complete all as specified.
Aluminium handles cast type anodised of size 150mm long ISI marked fixed in repairs complete all as specified and directed.
300 mm size mild steel ordinary rat tail rod pattern springs including roller and roller plate, ISI marked fixed in repairs complete all as specified and as directed.
300mm long aluminium alloy anodised sliding door bolt not less than 12mm dia with hasp staple, bolt type, and fixing clips of sheet, cast or extruded sections & fixing bolts and sliding bolts of extruded section or cast aluminium alloy, ISI marked fixed in repairs complete all as specified and directed.
Chequered cement concrete tiles 30mx30cmx25mm thick laid & jointed with grey cement and pointed in neat cement slurry in floors 15mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes all as specified and directed.
PCC 1:2:4, B-2 (40mm graded stone aggregate) as in surface channels and drain etc complete all as specified and directed.
Taking down steel tubing of any description/ size of 15/20mm complete all as specified and as directed by Engineer-in-Charge
Refixing old steel tubing in new or old position on walls, ceiling or floors etc of size 15 mm bore after cleaning including provn of new fittings if required complete all as directed.
Description all as per item No 80 here-in-before, but 20 mm bore.
Steel water tubing 20 mm bore medium grade galvanized with all fitting fixed to walls, ceiling & laid in floors etc complete all as specified and directed.
Description all as per item No 82 here-in-before, but 15mm bore.
PVC connection 15 mm size, of length 450 mm, with PTMT nuts complete all as specified and directed.
Stop valves cast copper alloy 15 mm dia, fancy type, chromium plated with long shank and cup (concealed type) screwed down, high pressure, with capstan handle screwed both ends for iron pipes or for unions and fixed in repairs, complete all as specified and directed.
Bib taps, fancy type chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, for bore dia of pipe 15mm, supplied and fixed in repairs complete all as specified.
CHOPRA CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .