| 1 | L1₹44.7 LAccepted-AOC 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC Due to lowest amount quoted | |
| 2 | L2₹52.6 L+₹5.4 L (11.4%)Rejected-Finance | L2 | Rejected-Finance Due to high amount quoted | |
| 3 | L3₹57.8 L+₹10.5 L (22.3%)Rejected-Finance PLOT NO 14 SHIV COLONY KATI GHATI RAJGARH ROAD ALWER RAJ | ALWAR | ALWAR | RAJASTHAN | L3 | Rejected-Finance Due to high amount quoted | |
| 4 | L4₹58.6 L+₹11.3 L (24.0%)Rejected-Finance | L4 | Rejected-Finance Due to high amount quoted | |
| 5 | L5₹61.9 L+₹14.7 L (31.0%)Rejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | L5 | Rejected-Finance Due to high amount quoted |
Tender Value
₹63.5 L
EMD Value
₹1.2 L
Closing Date
18 Jan 2023, 6:00 pmClosed
CWE Army Jaisalmer
HQ CWE Army Jaisalmer 345001
SPECIAL REPAIR/REPLACEMENT OF SECURITY POLE LIGHT AND ALLIED WORKS AT MIL STN JAISALMER
2022_MES_571289_1
84061
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Jaisalmer
As per cover 1
8 documents required · 8 mandatory
₹500
GE Army Jaisalmer
₹1.2 L
Yes
22 Mar 2023
26 Dec 2022
20 Jan 2023
26 Dec 2022
18 Jan 2023
11 Jan 2023
26 Dec 2022 - 10 Jan 2023
Amount
Taking out old unserviceable service cables of any size and at any location including protection pipes/bricks or precast concrete cable cover etc of any description from trenches/poles/transformers of any size and unserviceable materials removing from site all as specified and as directed.
Taking down old unserviceable PCC pole all as specified and directed.
Taking down old unserviceable street light of any type complete all as specified and directed .
Taking down old unserviceable copper cable of any size all as specified and directed .
Taking out old unserviceable rusted GI pipe of any size removing from site all as specified and as directed.
Taking down old unserviceable Service GI bracket all as specified and directed.
Taking down old unserviceable LT feeder pillar box any type all as specified and directed .
Taking down old unserviceable LT Panel complete all as specified and directed .
Taking down old unserviceable PVC conduit pipe 20 mm medium grade complete all as specified and directed .
Taking out old unserviceable stay assembly complete all as specified and directed .
Taking down old unserviceable Junction Box all as specified and directed .
Taking down old unserviceable Insulators any type all as specified and directed .
Taking down old unserviceable Angle iron all as specified and directed .
Taking down old unserviceable Earthing all as specified and directed .
Taking down old unserviceable Timer Switch Panel of any capacity all as specified and directed .
Supply, Laying, Jointing, commisssioning & testing XLPE insulated, armoured heavy huty electric cable with aluminium conductor, 1100 Volts grade, cross section area 70 Sqmm 3.5 core drawn through pipe or laid in trenches, fixed on poles etc. complete all as specified and as directed. Note : Earth work, GI pipe shall be measured and paid for seperately.
Supply, Laying, Jointing, commisssioning & testing XLPE insulated, armoured heavy huty electric cable with aluminium conductor, 1100 Volts grade, cross section area 10 Sqmm 4 core drawn through pipe or laid in trenches, fixed on poles etc. complete all as specified and as directed. Note : Earth work, GI pipe shall be measured and paid for seperately.
Supply, Laying, Jointing, commisssioning & testing XLPE insulated, armoured heavy huty electric cable with aluminium conductor, 1100 Volts grade, cross section area 25 Sqmm 3.5 core drawn through pipe or laid in trenches, fixed on poles etc. complete all as specified and as directed. Note : Earth work, GI pipe shall be measured and paid for seperately.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or Hard Rock for shaft, walls, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified & directed by Engr-in-Charge.
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5m in depth for foundation, laying of cable/pipe etc or soft/dis integrated rock for shaft, walls, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out complete all as specified & directed by Engr-in-Charge.
Returning, filling in including spreading, leveling, watering and well ramming excavated soft/disintegrated rock in layers , all as specified and directed at site
Removing excavated materials (Soft/Disintegrated Rock) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
M&L for sand cushioning to under ground cable using tibba sand and gently punning to cushioning to cable complete all as directed by Engineer-in-Charge.
Supply & laying 40 to 50mm thick roughly hammer dressed Jodhpur stone patti cable cover 25cm to 30cm wide and n. exc 60cm long each laid dry abutting with each other with maximum gap between adjacent slabs n. exc 10mm complete all as specified & directed by Engineer-in-charge.
Supply, transportation fixing and errection of prestressed cement concrete pole in repair 9 metre long, minimum cross section 102 mm x 172 mm at top and 102 mm x 279 mm at bottom class -10 confirming to IS-1678 and including making alternate white and black strips 30 cm height (Total 5 Nos ), with two coats of synthetic enamel paint over a coat of primer complete all as specified and directed by Engr-in-Charge.
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate in foundation for PCC poles/struts including necessary form work complete all as specified & directed by Engr-in-Charge.
M & L for plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation of PCC pole /stay assembly including necessary form work up to groud level all as specified and directed by Engr-in-Charge.
M&L for plain cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) for pedestal/coping/plinth of poles, including necessary form work finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L fo stay assembly complete comprising of MS galvanised stay plate 230 mm x 230 mm x 6mm , MS galvanised stay rod 16 mm dia with nut & bolts, 2.15 M long , MS galvanised stay bow 40 cm long with 02 Nos galvanised thimbles with and including all fittings as shown in electrical plate No 1 of SSR Part-I (loop type insulator, stay clamps, excavation( and concrete measured separately).complete all as specified and directed by Engr-in-Charge.
S & F GI Pipe 40 mm Tubes, 'light grade'galvanised,with all fitting and fixed complete to walls andceilings or laid in floors light grade on pole etc complete all as specified and directed by Engr-in-Charge.
Supply and fixing 3 core PVC cable copper conductor multistarnded 1.5 sqmm complete all as specified by Engr-in-Charge.
S & Fixing in repair security light bracket with GI pipe medium grade of size 40mm dia bent to shape of length 1.2 meter including flat 2 Nos iron clamp made of FI 40 mm x 6 mm, nuts, bolts, washers check nuts etc duly painted with two coat of synthetic enamel paint over a coat of red oxide primer complete.as specified by Engr-in-Charge.
S & F pole mounting box made out of PVC FR Grade (Syntex) with bus bar -03 Nos for phase & 01 No for Neutral 32 Amps supported on insulators and one No MCB 6 Amps, clamp made out of FI 25x6 mm , nut, bolts and washers etc duly painted with two coat of synthetic enamel paint over a coat of red oxide primer on clamp complete as specified by Engr-in-Charge.
Supply and fixing hightly efficient IP 66 and IS - 10322/IEC -60598 LED street lights 60 Watts are aerodynamically designed for all weather conditions with excellent thermal management, made with pressure die cast housing with toughened glass and high power LED's with secondary optics and IP66 protection. PF > 0.95 and system Efficacy ≥ 100 LPW10KV SPD and CRI>70 suitable for LED street light Included (60/70SL) as specified by Engr-in-Charge. Product Description MRP (`energy saving and enviorment friendly long life LED made up of pressure die cast aluminum hosing with high efficieny LEDs as lighting source and lens embedded PC cocer having TOP Opening seperate driver compartment with IP 66 protection and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete as specified & directed by Engineer-in-Charge.
M & L earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick, burried directly in ground (earth pit not less then 2.25m deep bellow ground level) with top edge of the plate not less then 1.5m deep below normal ground level connected to galvanised iron strip of 32 x 6mm earth lead by means of bolt, nuts, washers of galvanised steel earth strip protected by and including GI pipe 40mm dia bore (light grade) and conncted to main test point as directed and including concrete pit in PCC(1:3:6)type C-1 precast RCC(1:1.5:3)type A-1 cover slab 54 x 5 cm reinforced with 4mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8mm dia TMT bar embedded in precast cover slab funnel wire mens 20mm bore GI pipe (medium grade) for watering charcoal and salt in altemate layers, including necessary excavation and earth work in any type of soil complete all as shown on electrical plate No. 3 of SSR part-I complete all as specified.
Supply ,installation ,testing,and commissioning LT Feeder pillar/Panel board cubical type outdoor conforming to IS 8623 Part 1 1993 ,factory fabricated out of 3.15 mm thick CRCA sheet & suitable size to accommodate all acceessories / fitting , compartmentalized in construction to accomodate incoming and outgoing ,MCCB, MCB and TPN Aluminium Bus bar of rating not less 1.5 times the rated capacity of incomer MCCB/ACB and outdoor feeder. The TPN bud bar shall insulated with color coded heat shrinkable sleeve and shall be mounted on DMC/ Epoxy insulators of suitable size through out the length of TPN bus bar. The incoming as well as outgoing MCCBs shall have copper extension link of current carrying cap not lass than 1.5 times the rated capacity of individul feeders. The extension link shall be supported on DMC /Epoxy insulators having provision for termination of incoming and outgoing cables . All extension links / interconnection shall be insulated with heat shrinkable colour code sleeves. The cubical shall have a bottom channel of size 50x50X5 mm and and 45 cm height above the ground level duly fixed with PCC . a detachable predrilled gland plate of thickness not less than 3 mm thick should be used at a bottom for enrty of armoured cable of adequate size with glands. The above panel shall be front and back openable /lockable by the key from both side and shall have louvers and air vent gasket for natural floe of air.XLPE adhesive type gasket shall be used to make the panel weather , dust and vermin proof with IP 65 degree of protection ,complete as specified and consisting the following switchgears and accessories.:-
(a) 4 No's alumnium bus bar of rating 400 Amps mounted on heavy duty rubberised/porcelene support two set (Vertically and horizontaly)
(b) Incoming MCCB 4 pole ,250 Amp 415 Volts , 36 kA rupturing capacity ,with adjustable setting 80% to 100 % thermal magnetic release -01 No (Ics =100%Icu)
(c) Outgoing MCCB 4 pole ,100 Amp 415 Volts , 16 kA rupturing capacity ,with adjustable setting 80% to 100 % thermal magnetic release -02 No (Ics =100%Icu)
(d) Outgoing MCCB 4 pole ,63 Amp 415 Volts , 16 kA rupturing capacity ,with adjustable setting 80% to 100 % thermal magnetic release -02 No (Ics =100%Icu)
(g) Indicating lamp LED type 230 volts for RYB including all necessuary items set of three -01 No
(h) Danger Notice board-02
(j) PCC work complete
Note :- All MCCBs to be Ics= 100% Icu
Supply ,installation ,testing,and commissioning LT Feeder pillar/Panel board cubical type outdoor conforming to IS 8623 part 1 1993 ,factory fabricated out of 3.15 mm thick CRCA sheet & suitable size to accommodate all acceessories / fitting , compartmentalized in construction to accomodate incoming and outgoing ,MCCB, MCB and TPN Aluminium Bus bar of rating not less 1.5 times the rated capacity of incomer MCCB/ACB and outdoor feeder. The TPN bud bar shall insulated with color coded heat shrinkable sleeve and shall be mounted on DMC/ Epoxy insulators of suitable size through out the length of TPN bus bar. The incoming as well as outgoing MCCBs shall have copper extension link of current carrying cap not lass than 1.5 times the rated capacity of individul feeders. The extension link shall be supported on DMC /Epoxy insulators having provision for termination of incoming and outgoing cables . All extension links / interconnection shall be insulated with heat shrinkable colour code sleeves.The cubical shall have a bottom channel of size 50x50X5 mm and and 45 cm height above the ground level duly fixed with PCC . A detachable predrilled gland plate of thicknessnot less than 3 mm thick should be used at a bottom for enrty of armoured cable of adequate size with glands. The above panel shall be front and back openable /lockable by the key from both side and shall have louvers and air vent gasket for natural floe of air.XLPE adhesive type gasket shall be used to make the panel weather , dust and vermin proof with IP 65 degree of protection ,complete as specified and consisting the following switchgears and accessories.:-
(a) 4 No's alumnium bus bar of rating 250 Amps mounted on heavy duty rubberised/porcelene support two set (Vertically and horizontaly)
(b) Incoming MCCB 4 pole ,160 Amp 415 Volts , 25 kA rupturing capacity ,with adjustable setting 80% to 100 % thermal magnetic release -01 No (Ics =100%Icu)
(c) Outgoing MCCB 4 pole ,100 Amp 415 Volts , 16 kA rupturing capacity ,with adjustable setting 80% to 100 % thermal magnetic release -02 No (Ics =100%Icu)
(d) Outgoing MCB TPN 63 Amp , 4 Pole 415 Volts , 16 kA rupturing capacity ,with adjustable setting 80% to 100 % thermal magnetic release -01 No (Ics =100%Icu)
(e) Outgoing MCCB SPN 32Amp 230 V, -01 Nos
(h) Indicating lamp LED type 230 volts for RYB including all necessuary items set of three -01 No
(j) PCC work complete
(k) Danger Notice board-02
Note :- All MCCBs to be Ics= 100% Icu
M & L for Opening the binding wire from pin /shackle insulator on the Steel/ PCC pole of any height for restretching the ACSR conductor ,after restretching without kinks &bends ,binding the pin/shackle insulators with appropriate size of aluminium binding wire complete all specified by Engr -in-charge .Note:- (i) The above work includes clearing /prooning of tree branches falling around the conductors. (ii) Cost of binding wire deemed to be included in the quoted rate ,No extra amount will be paid. (iii) Ledder required for carriying out of job. (iv) Safety equpts provided to electrician will be responsibility of the contractor
S&F digital type advance microcontroller and real time clock base astronomical timer panel suitable for 3 phase 415v,AC having 8 bit micro controller with inbuilt battery,16 character two line LCD display, input isolator 125 Amp 4 pole and TPN elecrtic bus bar of rating 200 Amp supported on DMC/Epoxy isolators output with 06 Nos, 32Amps MCB SP and with complete copper conductor power wiring of suitable size, contactor 63 Amp 4 Pole-03 Nos, inside 2mm(16/18guage) thick feeder panel duly power coated complete with 40X40X5mm 45CM height angle iron structure with PCC complete suitable for 30 KVA load and suitable for staggering each phase complete all as specified and directed by Engr-In-Charge.
Supplu & fixing of 20 mm dia Rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but inclusiveof all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessoriessuch as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and directed by Engineer-in-charge
Supplu & fixing LT feeder pillar box out door tpye not less than 0.60 M x0.60 M x0.60 M made out of 3.15 mm thick CRCA sheet powder coated dust & vernin proof supported on angle iron frame 40x40x5 MM ,aluminium bus bar 04 Nos rated capacity 300 Amp fpr netural supported on porcelain insulators including painting with two coats red oxide primer and pcc foundation complete all as specified & directed by Engineer -in -charge.
S & F in repair LT 1100 Volts grade loop type ,pin type , porcelain, vitreous white brown or green insulators including one galvanised mild steel spindle , two galvanished iron washer and one galvansied iron nut , 100 mm height ,65 mm dia for 1100 volts gradecomplete all as specified & directed by Engineer -in -charge.
S & F GI Pipe 80 mm Tubes, 'light grade'galvanised,with all fitting and fixed complete to walls and ceilings or laid in floors light grade on pole etc complete all as specified and directed by Engr-in-Charge.
SHOBHIT BUILDERS
M/s Yash Electrical and Maintenance
star electricals
M/s Shree Construction Company
M.D. CONSTRUCTION CO.
S R ENTERPRISES
S.D. And Company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .