Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.1 LAccepted-AOC | L1 | Accepted-AOC Being overall reasonable | |
| 2 | L2₹46.0 L+₹1.6 L (3.56%)Rejected-Finance | L2 | Rejected-Finance Not lowest bid | |
| 3 | L3₹49.3 L+₹4.9 L (11.1%)Rejected-Finance NO 98 1 1C YOJANANAGAR LOHEGAON WAGOLI ROAD NEAR SIVBHA DARBAR HOTEL LOHEGAON PUNE 411047 | PUNE | PUNE | MAHARASHTRA | 411047 | L3 | Rejected-Finance Not lowest bid |
Tender Value
₹50.0 L
EMD Value
₹99,960
Closing Date
11 Nov 2021, 6:00 pmClosed
GE CENTRAL KIRKEE
GE CENTRAL KIRKEE RANGE HILLS ROAD KIRKEE PUNE 411003
PROVN OF CERTAIN SPECIAL REPAIR LBW AND MINOR WORKS IN THE AOR OF GE CENTRAL KIRKEE
2021_MES_481699_1
8529/E8 OF 2021-2022
Open Tender
Civil Works
Item Rate
180 days
KIRKEE
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹99,960
Yes
26 Nov 2021
13 Oct 2021
12 Nov 2021
13 Oct 2021
11 Nov 2021
28 Oct 2021
13 Oct 2021 - 27 Oct 2021
Amount
Surface excavation in soft/loose soil n.exc 30 cm deep and averaging 15cm deep and getting out complete all as specified and as directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as directed.
Removing excavated surplus soil not exc 50 m and depositing where directed at level n.exc 1.5 m above the starting point complete all as specified and directed.
M&L Plain cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation filling as mass concrete complete all as specified and as directed.
M&L Form work to sides of concrete foundations, footings bases of columns, raft and raft beams, sides and soffits ( if any ) of foundation plinth beam and similar work vertical or bottom rough finished surfaces of concrete in flat and curved surfaces complete all as specificed and as directed.
M&L Form work to sides of pillars, posts, struts, piers, columns rough finished surfaces square, rectangular or polygonal complete all as specificed and as directed.
M&L Form work to sides and soffits of floor or roof beams, beams haunching, girders, bressumers, lintels, cantilevers shelves including supports overhangs etc, also splays between floors and beams etc flat rough finished surface complete all as specificed and as directed.
M&L Use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) with rough finished flat concrete surfaces complete all as specified.
M&L Use and waste formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide with rough finished flat concrete surfaces complete all as specified and as directed.
M&L RCC M-25 design mix (using 20 mm graded stone aggregate.) in footings & plinth beams etc. complete all as specified and directed.
M&L RCC M-25 design mix (using 20 mm graded stone aggregate.) in columns etc. complete all as specified and directed.
M&L RCC M-25 design mix (using 20 mm graded stone aggregate.) in roof beams & lintel beam etc. complete all as specified and directed.
M&L RCC M-25 design mix (using 20 mm graded stone aggregate.) in roof slabs supported on walls etc. complete all as specified and directed.
M&L RCC M-25 design mix (using 20 mm graded stone aggregate.) in Chajjas etc. complete all as specified and directed.
M&L mild steel TMT bar 10 mm dia and over, cut to length, bent to shape required and binding with MS wire (annealed) not less than 0.9mm dia. complete all as specified and directed.
M&L mild steel TMT bar 5mm dia and over upto and including 10mm dia cut to length, bent to shape required and binding with MS wire (annealed) not less than 0.9mm dia. in stirrups, spacers and binders. complete all as specified and directed.
M & L Spreading and levelling in layer n. exc. 25 cm thick including well ramming watering as required complete all as specified and directed.
M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M&L for Hardcore of broken stone or boulders gauge n exc 63mm, deposited spread levelled in layers n exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L Cement concrete 75mm thick (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub base of floor complete all as specificed and as directed.
M&L for precast cement concrete block masonry of grade C-5 having density not less than 1800 kg/cum and 28 days average minimum compressive strngth of block should be 5 N/sqmm as in walling set in cement mortar 1:6 complete all as specified and as directed.
M&L for Brickwork with sub-class `B' bricks, straight or curved on plan to any radius as in half brick thick walls, built in CM 1:4 complete all as specified and as directed.
M&L rendering 10 mm thick on concrete surfaces of wall in CM 1:4, to receive wall tiles or kota stones complete all as specified.
M&L for 5mm thick rendering on concrete surfaces of ceiling in CM (1:3) and rendering is to be finished even and smooth without using extra cement complete all as specificed and as directed.
M&L rendering 10 mm thick on concrete surfaces of wall in CM 1:6, finished even and smooth without using extra cement complete all as specificed and as directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 (external) with using WPC and finishing top surfaces even and smooth without using extra cement complete all as specified and as directed.(WPC shall be measured and paid seperately)
Supply only approved integral waterproofing compound.
M&L 75mm thick Plain Cement concrete (1:3:6) Type C-2 (using 40mm graded stone aggregate) as in plinth protection, surface finished even and smooth without using extra cement complete all as as specified and as directed by Engr-in-Charge.
M&L Forming 12 mm thick expansion joint with pre-formed filler and top 30 mm primed and sealed with sealing compound Grade ‘A’ all as specified for thickness of concrete slab 75mm complete all as specified and directed.
S&F for powder coated anodised aluminium ventilator shutters, fixed type without sash bar including stainless steel wire cloth of 0.63 mm nominal dia and average aperture 1.4 mm, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc.and fixed to block/stone masonry wall complete all as specificed and as directed.
S & F framed work such as grills, grating etc with ends bars shouldered and / or riveted or forged into spikes, framed guard bars, barred iron doors and similar work confirming to Fe 290 Gde E-165 complete all as specified and as directed.
M & L Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and as directed.
S & F 2nd class hardwood 35 mm thick Plain, framed, panelled shutters (two number of panels), with panels with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated supplied and fitted to chowkats complete all as specified and as directed.
M&L for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
S&F solid PVC door frame of size 50 mm x 47 mm made of 5 mm plain colour PVC sheet reinforced with mild steel square tube complete all as specified in clause 8B.3.1 and shown on page 150 of MES Schedule Part-II (2010) complete all as specified and as directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2004) complete all as specified. (Make: Rajashri or equivalent as approved.)
S&F 100 mm butt hinges, medium weight, cold rolled mild steel complete all as specified and as directed.
S&F for aluminium handles size 150 mm cast type anodised complete all as specified and as directed.
S&F aluminium anodised barrel tower bolt 200mm long of extruded section with steel screws complete all as specified and as directed.
S&F 300mm long Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and as directed.
S&F 200mm long Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and as directed.
S&F wash down water closet (pedestal pattern) complete (including fixing of seat cover) pedestal pan and trap including connection to drain (or outgoing pipe ) and flushing pipe, antisyphonage pipe etc complete all as specificed and as directed.
S&F Vitreous china white squatting pan orrissa pattern of size 580mm x 440 mm with integral foot rests including necessary lime concrete and 100 mm bore cast iron ‘P’ or 'S' trap with 550 to 600 mm long neck for connecting WC to branch piece with cement joints, squating pan including connection to trap and to flushing pipe, antisyphonage pipe complete all as specified and as directed.
S&F chromium plated bib taps long body, fancy type, cast copper alloy with capston head handle with cup, screwed for 15mm bore of iron pipe or for brass ferrule complete all as specified and as directed.
S&F pillar tap, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly-nuts, screwed for 15mm bore iron pipe, complete all as specified and as directed.
S & F stop valves cast copper alloy, screwed down, high pressure with butterfly handle, screwed both ends for iron pipe or for unions 15mm bore complete all as specified and as directed.
S&F PVC low level flushing cistern (white) of 10 liters capacity with inlet ball float valve, PVC flush pipe and necessary fixing arrangements and connecting to water pipe and WC etc complete all as specified and as directed.(Note:Rate quoted shall be deemed to be included taking down flushing cistern if any, if ordered by the Engineer-in-charge)
S&F wash hand basin, flat back 550x400mm vitreous china (white) including PTMT waste fittings, 32mm bore size, angle iron/cast iron brackets of required size as directed & making good disturbed surfaces to match with the existing complete all as specified and as directed.
S&F PVC (SWR) pipes, 75 mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors etc complete all as specified and directed.
S&F PVC (SWR) pipes, single socketed, 110mm bore in any length with rubber ring joints, laid in trenches or in floors etc complete all as specified and directed
S&F for provision of 75 mm dia of outlet PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specificed and as directed.
S&F PVC (SWR) bends of any radius 110 mm bore/dia complete all as specified and as directed.
S&F PVC (SWR) bends of any radius 75 mm bore/dia complete all as specified and as directed.
S&F 110mm bore/dia PVC vent cowl all as specified and directed.
S&F Galvanised iron steel water tubing, 15mm bore, medium grade with all fittings and fixed to walls and ceilings or laid in floors complete all as specified and as directed.
S&F Galvanised iron steel water tubing, 20mm bore, medium grade with all fittings and fixed to walls and ceilings or laid in floors complete all as specified and as directed.
S&F Galvanised iron steel water tubing, 25mm bore, medium grade with all fittings and fixed to walls and ceilings or laid in floors complete all as specified and as directed.
S&F in gun metal gate valve with iron wheel head, screwed both ends for iron pipes 25 mm bore complete all as specified and directed.
S & F Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 75mm bore etc complete all as specified and directed.
S&F 500 litres capacity rotational moulded, polythene water storage tanks (cylindrical vertical with closed top) hoisting and fixed in position on roofs including fittings, complete all as specified and as directed.
S&F 25mm bore ball valve high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe. (Minimum weight 15mm-142gms/ 20 mm - 210 gms . / 25mm-455gms/ 40mm - 690 gms) complete all as specified and as directed.
M & L for Non skid ceramic coloured tiles 7 to 8mm thick (square or rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set in neat cement slurry and pointed in coloured cement to match coloured tiles including 15mm thick screed bed in CM (1:6) complete all as specified and as directed.
M&L for Glazed ceramic coloured tiles in vertical surface 450 X300 X7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and as directed.
M & L for Machine cut kota stone slab flooring 20-25mm thick over and including 15mm thick cement screed bed in CM 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed by Engr in Charge.
M&L machine cut kota stone slab 20-25mm thick over and including 10mm thick backing coat of cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and mirror polishing as in skirting, vertical any type of surfaces, riser of steps including moulding where required complete all as specified and as directed.
M & L preparing new plastered surfaces of wall and applying two coats of dry distemper over a coat of alkali resistant primer complete all as specified and as directed.
M & L preparation of newly plastered surface of wall and applying two coat of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
M&L for applying three coats of white wash on ceiling including preparation of newly plastered surfaces complete all as specificed and as directed.
S&F PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and as directed.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth ; for foundation or for shafts, wells, cesspits, manholes, pierholes, etc n.exc 10 sqm on plan and n exc 1.5m in depth and getting out in hard/dense soil complete all as specified and directed.
M&L plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregates) as in foundations,filling and mass concrete etc.complete all as specified & directed.
M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) in lintels upto 1.5 m clear span, cills, steps seismic and other similar bands plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height copings, kneelers, apex stones, bed plates, kerbs, water troughs, benching and the like including weathering, slightly rounded or chamfered angles and throating, complete all as directed.
M&L Precast RCC slab 1:2:4, type B1(using 20mm graded stone aggregates) as in cover slab (for manholes), landings, chajjas,water troughs,hangers, shelves and similar articles with plain faces set in CM 1:4 complete all as specified and directed.
M & L TMT mild steel bars 6 to 8mm dia and over, cut to length, bent to shape required inluding cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips complete all as specified and directed.
M&L for providing plain cement concrete 1:3:6 type C-2 (Using 40 mm graded stone aggregates) as in concrete bed to drain pipes for 150 mm bore dia including forming cradles after laid and tested etc. complete all as specified and as directed.
M&L for Reinforced cement concrete pipes,150 mm bore of pipes Class NP-2, laid and jointed with collars complete all as specified and as directed.
M&L for preparing new plastered surfaces of walls and applying evenly three coats of white wash complete all as specified and directed.
M&L for Soakage wells of size 2.4M diaX 3.0 M effective depth excavation, in any type of soil, including intercepting chamber and screen chamber made of Brick masonary cover slab / SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size all as specified and as shown in drawing No.CEPZ/2019/TD/13 Sheet 1/2 and 2/2 dated 30 Apr 2019 and as directed by Engr-in charge.
Surface excavation in hard dense soil n.exc 30 cm deep and averaging 22.5cm deep and getting out complete all as specified and as directed.
M & L for 100 mm thick PCC 1:4:8 type D2 (using 40 mm graded granite stone aggregate) in sub base complete all as specificed and as directed.
M&L for sand/stone dust filling under floor or in foundation or for cushioning of UG cable/ at cable trenches including watering and consolidation complete all as specificed and as directed.
M & L for Coloured Machine pressed glossy finished precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade with grey cement and no pigment laid over sand cushion complete all as specificed and as directed.
Supply fixing and laying in trenches galvanised steel water tubing 40 mm bore, medium grade with and including all medium grade fittings complete all as specified.
Supply fixing and laying in trenches galvanised steel water tubing 25 mm bore, medium grade with and including all medium grade fittings complete all as specified.
S&F in gun metal gate valve with iron wheel head, screwed both ends for iron pipes 40 mm bore complete all as specified and directed.
Taking down cement plaster on brick or stone walls or concrete surfaces etc at any position including raking out joints, hacking for key, scrubbing down with water complete all as specified and as directed.
Taking down existing bituminous felt from existing roof and disposed off complete all as specified and as directed.
Demolition of cement concrete in ground floors and pavings n exc 15cm thickness (below or above ground level) complete all as specified and as directed.
M&L 25mm thick PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in base course complete all as specified and as directed.
S & F 110mm dia PVC (SWR) pipes single socketed in any length with rubber rings joints fixed to walls or laid in floors as sanitary fittings, rain water pipes etc in any position including taking down sanitary pipes, eaves gutters and rainwater pipes (any size or pattern), in any type and position including all fittings, heads, shoes, bends, swan-necks, branch pieces, couplers, reducers, vent cowl, stack clamps etc. complete all as specified and as directed.
S & F 75mm dia PVC (SWR) pipes single socketed in any length with rubber rings joints fixed to walls or laid in floors as sanitary fittings, rain water pipes etc in any position including taking down sanitary pipes, eaves gutters and rainwater pipes (any size or pattern), in any type and position including all fittings,heads,shoes, bends, swan-necks, branch pieces, couplers, reducers, vent cowl, stack clamps etc. complete all as specified and as directed.
S&F in repair 110mm PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and as directed.
S&F PVC (SWR) bends of any radius with access doors 110 mm bore/dia complete all as specified and as directed.
S&F PVC (SWR) bends of any radius with access doors 75 mm bore/dia complete all as specified and as directed.
S&F PVC (SWR) branch piece, double (double 'Y'), equal or unequal, with access door and fixed 75mm bore/dia complete all as specified and as directed.
S&F 75mm bore/dia PVC cowl all as specified and directed.
Taking down chowkats and frame n.exc 1.5 Sqm each of any type including shutters without taking off shutters from the frame complete all as specified and as directed.
Taking down chowkats and frame exc 1.5 Sqm but n.exc 4.00 sqm each of any type including shutter wiuthout taking off shutter from the frame complete all as specified and as directed.
S&F aluminium powder coated window sliding type (3 track) with frame size 100x35x1.2mm thick and shutter frame size 39.40x17.70x1.2mm thick with two glass shutter and one wire mesh shutter including necessary jointing cleats, glazing clips, rubber packing, powder coated aluminium snap beading screws with and including 4mm thick plain float glass and 0.63mm dia apperture 1.4mm stainless steel wire mesh and fittings etc and making good the jambs and painting with paint should match with the existing suface complete all as specified and as directed.
S & F 35mm thick 2nd class HW glazed or skelton shutter open rebated divided into square with plain chamfered or rounded mitred and rebated without sash bar and prepared to receive gauze or glaze, size of members as per clause No. 8.20 (a) of SSR pt-1 complete all as specified and as directed by Engineer-in-Charge.
M&L for 35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on one face and other side covered with decorative face veneer with liping/ frame to match including all necessary fittings, complete all as specified and as directed by Engr-in-Charge.
M & L for preparation of new or previously untreated wooden surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamal paint over a coat of pink primer complete all as specified and directed.
S & F 300mm size aluminium alloy, anodised, sliding door bolt of dia not less than 12mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed by Engineer-in-Charge.
S & F mild steel spring for doors 300mm long, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed by Engineer-in-Charge.
S&F aluminium anodised barrel tower bolt 150mm long of extruded section with steel screws complete all as specified and as directed.
Taking up or down steel water tubings and connections bore of pipe 15mm dia complete all as specified and as directed.
Taking up or down steel water tubings and connections bore of pipe 20mm dia complete all as specified and as directed.
Refixing 15mm and 20mm bore old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and as directed.
Disconnecting existing tanks n exc 500 litre capacity, setting aside ( or lowering if required ) for repairs, cleaning,etc. and hoisting if required reconnecting and refixing in position (Cleaning repairing, etc. measured separately) complete all as specified and as directed.
S&F Rubber door seal size, length and thickeness as orderd complete all as specified and as directed by Engineer-in-charge.
S&F in repair Vitreous china white squatting pan orrissa pattern of size 580mm x 440 mm with integral foot rests(excluding flushing cistern and flush pipe) including necessary lime concrete, connection to trap and to flushing pipe, antisyphonage pipe complete all as specified and as directed.
S&F in repairs wash hand basin, flat back 550x400mm vitreous china (white) with and including Waste coupling of PTMT (half or full threaded) (Minimum weight 32mm-45gms/40mm-60 gms), 32mm bore size, pvc waste pipe and angle iron/cast iron brackets of required size as directed & making good disturbed surfaces to match with the existing complete all as specified and as directed.
S & F in repairs brass CP shower rose 125mm size with swivel joint including fixing to steel pipe complete all as specified and as directed.
S & F in repairs stop cock cast copper alloy, chromium plated fancy type screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions or brass ferrule with long shunk and cup 15mm bore complete all as specified and as directed.
S&F in repair bib taps, cast copper alloy, chromium plated, fancy type screwed for 15mm bore of iron pipe or for brass ferrule complete all as specified and as directed.
S & F in repair stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.4 mm fixed with tinned tack of stainless steel wire staple or wooden beads complete all as specified and as directed.
S&F in repair stainless steel glossy finish Soap dish fixed to plugs with chromium plated brass screws complete all as specified. (Make : Prayag cat No. BA-15S)
S&F in repairs Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) complete all as specified.
S&F in repair chromium plated Towel ring fixed with and brass screws and wooden/plastic cleats (Minimum weight 170gms) complete all as specified and as directed.
S&F in repair brass chromium plated Towel Rail 20mm dia 60cm long fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 170gms) complete all as specified and as directed.
S&F in repairs Mild steel Hat peg and coat hooks, solid body, 175mm to 250 mm complete all as specified and as directed.
S&F in repairs SS Curtain/drapery rod 25mm dia fancy type complete all as specified and directed.
S&F in repair decorative Knob stainless steel curtain brackets for fixing of curtain rods including necessary fittings such as rawl plug and screws complete all as specified.
M & L cement concret prepolished chequered tiles 300x300x25 mm thick with grey cement and pigment, set and jointed in neat cement slurry and pointed in colured cement to match the pigments, over and including 20mm thick screed bed or bedding layer in CM 1:6 etc. complete all as specified and as directed.
M&L for preparing new Steel Surfaces of any description, over 10cm in width or girth, not otherwise described and applying evenly two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
M & L preparing old plastered wall surfaces by applying 3mm thick wall care putty to get smooth and even surfaces as directed and applying two coats of oil bound distemper complete all as specified and as directed.
M&L applying two coat of Acrylic Exterior Emulsion (Apex Ultima) on walls over primer including preparation of old surfaces of walls complete all as specified and as directed by Engr-in-charge.
Excavating in post holes (or similar holes) in hard dense soil each n exc 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and as directed.
M&L 150mm thick PCC 1:2:4 type B-2 (using 40mm graded stone aggregate) as in Sub base and pavings complete all as specified and as directed.
M&L for steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St.-240 complete all as specified and as directed.
S&F pre painted galvalume aluminum zink coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed.
M&L Forming Construction joint 30mm deep x 10mm wide filled with sealing compound Grade ‘A’ all as specified complete all as specified and directed.
Supply fixing and laying in trenches galvanised steel water tubing 20 mm bore, medium grade with and including all medium grade fittings complete all as specified.
S&F in gun metal gate valve with iron wheel head, screwed both ends for iron pipes 20 mm bore complete all as specified and directed.
M&L Extra for forming fair finished drain or channel 57 cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends etc complete all as specified and directed.
M&L Extra for forming fair finished drain or channel 74 cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends etc complete all as specified and directed.
Supply and placed On site Hume Pipe septic tank designed to carry sewage and sullage water, including excavation in any type of soil or hard rock, PCC 1:4:8 below foundation, Vent shaft, connection etc., having capacity for 05 users complete all as specified and as shown in CEPZ zonal TD and as directed.
Demolition and breaking up 150mm bore drain pipes (SGSW/AC/RCC) including haunching and benching set in cement mortar complete all as specified and as directed.
M&L for Reinforced cement concrete pipes, 200 mm bore of pipes Class NP-2, laid and jointed with collars including demolition and breaking up drain pipes (SGSW/AC/RCC) including haunching and benching set in cement mortar complete all as specified and as directed.
M& L for PCC 1:3:6 type C2 using 40 mm graded stone aggregate as in bed to drain pipe 200 mm bore including forming cradles complete all as specified and as directed.
Cleaning of existing septic tank of 100 to 200 users capacity by using Mechanical Pumping Machine to removing water, sludge, stones, solid particles etc complete from the septic tank at any location and at distance from road and removing the same from the campus and buried complete all as specified and as directed as below: (i) The sludge/burried soil etc taken out shall be stacked alongwith the septic tank, sump well etc. After 48 hours of the sludge taken out, measurement shall be taken as of the solid contents for the purpose of payment. The tenderer are advised to keep this aspect in mind while quotating the rates. After taking the measurements, the solid contents shall be disposed off outside the Md land/area. (ii) Necessary precautions as well as safety measures shall be taken by the contractor without any extra cost, for working in the foul conditions. (iii) The contractor shall be entirely responsible for the lapse, mishappening to any of the manpower deployed and/or to other equipment/machinary/material at the site of work during the execution.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles complete all as specified and as directed.
M&L Extra for forming fair finished drain or channel 40 cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends etc complete all as specified and directed.
M&L for concealed point wiring with two single core PVC insulated unsheathed 1100 volt grade multistranded FRLSH copper conductor cable of size 1.5sqmm (Nominal area) drawn into and including PVC conduit of medium grade of required size with all fitting and accessories alongwith one single core green colour PVC insulated 1100 volts grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for One light point or one fan point or one call bell point controlled by one, one way switch including 3 mm thick hylam sheet screwed with 04 Nos cadmium coated screws & cup washers with MS concealled box mounting of switch, regulators or bell push and casing caping terminal box for mounting ceiling rose/ holders etc all as specified and as directed.
M&L for concealed point wiring with two single core PVC insulated unsheathed 1100 volt grade multistranded FRLSH copper conductor cable of size 1.5sqmm (Nominal area) drawn into and including PVC conduit of medium grade of required size with all fitting and accessories alongwith one single core green colour PVC insulated 1100 volts grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for One 5 Amp socket point in same board including 3 mm thick hylam sheet screwed with 04 Nos cadmium coated screws & cup washers with MS concealled box mounting of switch, regulators or bell push and casing caping terminal box for mounting ceiling rose/ holders etc all as specified and as directed.
S&F 5 Amp switch piano type single pole one way (Dismantling old also if orderd by Engineer in charge)
S&F socket flush type 6 amps, 5 pin, 230v complete all as specified and as directed(Note: Rate quoted shall be inclusive of Dismantling old also if orderd by Engineer in charge)
S&F ceiling rose surface Bakelite three terminal complete all as specified and as directed.
S&F MCB sinle pole 6 Amp to 32 Amps, 240 volts, 10 KA breaking capacity, 'C' curve. Make : Cat Part No. 4085-87 to 4085-95 of Legrand or equivalent of Schneider/ABB.
S&F MCB double pole 6 Amp to 32 Amps, 415 volts, 10 KA breaking capacity, 'C' curve. Make : Cat Part No. 4086-28 to 4086-36 of Legrand or equivalent of Schneider/ABB.
S&F MCB DB, double door, metal enclosure, SPN, 230 volts, 4 way including dismantling unserviceable one all as specified and directed. Make : Cat Part No. 5076 10 of Legrand or equivalent of Schneider/ABB.
M & L LED building security light 15 watt, 230V complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade 20 mm dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastener all as specified and directed. Make- CG, Cat Part No LSTP-15-CDL or equivalent in Bajaj/Philips/HPL/Havells
S&F LED batten fitting, 20 watt, CDL, 230 Volts, 4 feet long , complete with all accssories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm twin core copper flexible conductor cable incl LED lamp and mounting casing box 2 nos all as specified and directed. Make-HPL, Cat Part No HPLLEDT5PC20W or equivalemt in Bajaj/Philips/CG/Havells
S&F LED batten fitting, 2'long, 09 watt,CDL 230 Volts, complete with all accssories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable with mounting casing box 2 nos all as specified and directed. Make-HPL Cat Part No- HLPT51509PCGCW or equivalemt in Bajaj/Philips/CG/Havells
Supply and fix Exhaust fan 225 mm sweep Metallic Grey including all connection all as specified and as directed. Make Bajaj Cat part No 70002 or Havells/Crompton.
M & L for Earthing complete with galvanised steel pipe electrode, 40 mm bore, medium grade, 3 mtr long buried directly and vertically in ground with top edge at ground level after making bore hole of size not less than 300 mm dia and 3.0 Mtr long using suitable mechanical drilling rig (for drilling near the specified bldg), connected with galvanised steel earthing lead of 4mm dia all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2with RCC precast pit cover slab 400mmx400mmx80mm with handle for lifting made out of 8mm dia MS rod, funnel, wiremesh, 15 mm dia light grade GI tubing for protection of GI wire 4mm dia, charcoal and salt in alternate 150mm thick layers around GI earth pipe, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion.
Supply and lay LT UG cable 2 core 6 Sqmm XLPE insulated armoured 1100 Volts grade heavy duty cable with PVC insulated stranded aluminium conductor laid in trenches incl indoor and out door joint all as specified and directed.
Supply only HDPE Double wall corrugated pipe (DWC) confirming to IS-14930(Part-II) of size-50/38mm including snap fit coupler as required, for cable protection.
M & L for point wiring with two single core PVC insulated multi stranded FRLSH Copper cable of size 1.5 sqmm drawn in and including PVC casing caping of required size with all fittings and accessories alongwith green colour FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one light/ fan / call bell point controlled by one, one way switch including PVC switch board and accesories of required size and making good to disturbed surfaces Note - One phase, one neutral and one earth of copper wire will measured as one point.
All as per item no 163 above for One three pin 5 Amp socket outlet point with cables 1.5 sqmm size on independent bord.
All as per item no 163 above for One three pin 5 Amp socket outlet point ,with cables 1.5 sqmm size on same board.
All as per item no 163 above for One three pin 16 Amp socket outlet point ,with cables 2.5 sqmm size on independent board.
M & L for sub main wiring with two single core PVC insulated multi stranded FRLSH Copper conductor cable of size 6.0 sqmm drawn through in and including PVC casing caping of size with all accesories and one single core green colour FRLSH Copper conductor cable of size 4 sqmm as earth wire and connected to earth dolly and making good to disturbed surfaces .NOTE: (a)Two run of cable with one run of earth wire and one run of casing capping will be measured as one unit (RM)
S&F switch socket combination multipurpose 2-in-1 flush type 3 pin 16 amps and 3 pin 6 amps, 230v (Dismantling old also if orderd by Engineer in charge)
S&F lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings.(Dismantling old also if orderd by Engineer in charge)
S&F LED lamp 12 watt, CDL, B-22 cap,(Pin type), 230V, PF-0.95 (min) including dismantling taking out unsv CFL complete all as specified and directed.
S&F Galvanised iron steel tubing, 32mm bore, light grade with all fittings and fixed to wall ceilings or pole complete all as specified and as directed.
S&F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm complete all as specified and as directed.
M&L street light bracket, made out of 40mm dia GI medium grade pipe 0.80m long bend to shape as required and welded and fixing in position complete all as specified and as directed.
S&F LED street light 45 watt with lense asthetically designed roadway luminiare complete all as specified and as directed. Make: Bajaj cat part No. LENXT F174 45 L WW CR PC SD or equivalent in HPL, Philips, and Crompton.
S&F street light pole box (SMC) type suitable for fixing on LT pole, of size 35cmX25cmx15cm with side hinged door, and locking arrangements and suitable for terminal for single phase including MCB 6-10 Amps SP, and fixing in position with nut, bolt and clamps complete all as specified and as directed.
Aishwarya Constructions
S.R.M.K Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .