Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 CrAdmitted-Finance KALU BASS SHRI DUNGARGARH BIKANER RAJASTHAN 331803 | BIKANER | BIKANER | RAJASTHAN | 331803 | ₹6.5 Cr | L1 | Admitted-Finance |
| 2 | L2₹10.7 Cr+₹4.2 Cr (63.6%)Admitted-Finance 21 PASCHIM VIHAR EXTENSION NEW DELHI 110 063 | NEW DELHI | WEST DELHI | DELHI | 110063 | ₹10.7 Cr+₹4.2 Cr (63.6%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical NO in WLR |
| Sl No | Description | Qty | Unit | M/s R L PAREEK L1 | M/s R. K. Bhambri L2 |
|---|---|---|---|---|---|
| 1.00 | SEWAGE TREATMENT PLANT (75 KLD CAPACITY) Design, supplying, fabrication, installing, testing & commissioning of Pre fabricated package type Sewage Treatment Plant of capacity 75 KLD. The sewage treatement shall be based on MBR technology. The nature of effluent from domestic sewage from toilets and kitchen shall be discharge seperately into the STP. The cost will also include MS puddle flange, Inlet, Outlet, overflow, test line, drain line, by-pass line, vent, foot rest, inspection platform with railing, moving ladder and making support for pipes. Complete Sewage Treatment Plant of capacity 75 KLD to be provided as per the details given in Schedule 'A" Part-I from page No 38 to 42 of CA. | 2 | Each Job | 65,80,000 ₹1,31,60,000 Lowest | 1,18,00,000 ₹2,36,00,000 |
| 2.00 | Designing, Supplying, Developing, Installing and Commission SCADA System for 75 KLD Sewage Treatment Plant along with various Automation equipment for STP as indicated and as per details attached. The STP SCADA system shall comprise Complete Sewage Treatment Plant of capacity 75 KLD to be provided as per the details given in Schedule 'A" Part-I from page No 43 of CA. | 2 | Each Job | 7,25,000 ₹14,50,000 Lowest | 12,00,000 ₹24,00,000 |
| 3.00 | Supply, Installation , Testing and commissioning of CPRI APPROVED extendable, compartmentalised, front operated , back openable, LT cubicle STP panel having ingress protection of IP 54, suitable for operation on 415 Volt 3 phase 50 c/s power supply fabricated out of 2 mm thick CRCA sheet steel and base channel of MS section not less than 100mmX50mmX5mm, gland plate of 3 mm thick cleaned and treated in 7 tank process and powder coated with approved shade with TPN Electrolytic Aluminium busbar of 200 Amps duly insulated in colour coding & suitable to withstand 25 MVA fault lavel complete with supplying & installation of following equipment including interconnection, control wiring etc as required. All MCCBs shall have microprocessor based release & shall have manually operated handle.It includes all wiring , cabling of required sizes from STP panel board to each electrical parts with on site control panel for individual motors . The panel will consists of following Items as per drawings attached.(Panel shall be of outdoor type installation with suitable IP Protection)
(a) Incomming :-(i) 100Amp, 4 Pole, MCCB (25KA) with Microprocessor =01 No
(ii) R.Y.B Phase indication lamp with fuse =1 set.
(iii) 0-100 A Digital Ammeter 150/5A Class 10 , 1 set
(iv) 0-500V Digital Voltometer with Control MCB 1 set
(b) Out Going :- (i) 40 Amp, TP MCCB 15KA ICS with automatic star delta Starter as per type -2 cordination with single phase preventer under/ overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 sets (For Two Numbers Air blowers , 110m3/hr. (0.50 wc) 5.0HP motor each).Blower Model Number :AB 4130
(ii) 10A TP MCCB 10KA ICS with automatic DOL Starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set of 2 numbers(One Working +One standby) (For Wet Well Submercible sewer pumps ,Qty : Two Numbers ,2.0 H.P each pump(1 working + one standby) Discharge 3.6 m3/hr.10m head.
(iii) 6A TP MCCB 10KA ICS with automatic DOL Starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -1 nos: (For One number anoxic tank submerged mixer ,1.0 HP each) Model SUZ/RW3033 | 2 | Each Set | 1,75,000 ₹3,50,000 Lowest | 7,00,000 ₹14,00,000 |
| 3.01Item no. 3 (contd...) (iv) 10A TP MCCB 10KA ICS with automatic star delta Starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos(One working+one standby) (For Two Numbers RAS pumps ,2 H.P each) 150LPM. (v) 6A TP MCCB 10KA ICS with automatic star delta Starter as per type -2 cordination with single pahse preventer under/overvoltage protection, overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. - Two numbers (One Working+One Standby) Filter press feed pumps , 0.5 H.P each). (vi) 6A TP MCCB 10KA ICS with automatic star delta Starter as per type -2 cordination with single pahse preventer under/overvoltage protection, overload and short circuit protection,R.Y.B Phase indication lamp with fuse . -2 nos: (For One number Filter Press Hydraulic press machine motor , 0.5 H.P. (vii) 10A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers(One working +one standby) PERMEATE PUMPS 1.5 HP each pump) 4.0 m3/hr. Head : 20mWC (Two numbers ) VFD operated. (viii) 10A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection, R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For One numbers Air compressor motor 2.0 HP each pump) 200 LPM , 125 psi pressure. (ix) 6A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers (1 Working +One standby) MBR C.I.P Pumps and other fitting parts , 1.0 HP each) (x) 6A DP MCB 10KA ICS with under/overvoltage protection,overload and short circuit protection, indication lamp with fuse 1 set. -2 nos: (For SIX numbers Pneumatic Valves with flange fitting parts each) (xi) 6A DP MCB under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers Citric Acid Dosing Pumps ) | |||||
| 3.02Item no. 3 (contd...) (xii) 6A TP MCCB 15KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers CITRIC ACID MIXER , 0.5 HP each) (xiii) 6A DP MCB under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers Hypo Dosing Pumps ) (xiv) 6A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers Hypo Mixer ,0.5 HP each) (xv) 6A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers Treated water Distribution Pumps, 4 HP each). (xvi) 6A DP 10 KA for ON line Monitoring System and two number flow meters (xvii) 16A DP 10 KA for Spare -03 No for PLC board. (xviii) 32A DP 10 KA for Spare -03 No for STP Plant building & Street light. The above panel includes all kind of MCB , MCCB, MPCB, ENERGY METER , Indication Lights , Selector Switches ,Push Button. | |||||
| 4.00 | SEWAGE TREATMENT PLANT (50 KLD CAPACITY)
Design, supplying, fabrication, installing, testing & commissioning of Pre fabricated package type Sewage Treatment Plant of capacity 50 KLD. The sewage treatement shall be based on MBR technology. The nature of effluent from domestic sewage from toilets and kitchen shall be discharge seperately into the STP. The cost will also include MS puddle flange, Inlet, Outlet, overflow, test line, drain line, by-pass line, vent, foot rest, inspection platform with railing, moving ladder and making support for pipes. Complete Sewage Treatment Plant of capacity 50 KLD to be provided as per the details given in Schedule 'A" Part-I from page No 44 to 48 of CA. | 1 | Each Set | 53,46,000 ₹53,46,000 Lowest | 86,00,000 ₹86,00,000 |
| 5.00 | Designing, Supplying, Developing, Installing and Commission STP SCADA System for 50 KLD Sewage Treatment Plant along with various Automation equipment for STP as indicated and as per details attached. The STP SCADA system shall comprise Complete Sewage Treatment Plant of capacity 50 KLD to be provided as per the details given in Schedule 'A" Part-I from page No 49 of CA. | 1 | Each Job | 5,65,000 ₹5,65,000 Lowest | 12,00,000 ₹12,00,000 |
| 6.00 | Supply, Installation , Testing and commissioning of CPRI APPROVED extendable, compartmentalised, front operated , back openable, LT cubicle STP panel having ingress protection of IP 54, suitable for operation on 415 Volt 3 phase 50 c/s power supply fabricated out of 2 mm thick CRCA sheet steel and base channel of MS section not less than 100mmX50mmX5mm, gland plate of 3 mm thick cleaned and treated in 7 tank process and powder coated with approved shade with TPN Electrolytic Aluminium busbar of 100A duly insulated in colour coding & suitable to withstand 25 MVA fault lavel complete with supplying & installation of following equipment including interconnection, control wiring etc as required. All MCCBs shall have microprocessor based release & shall have manually operated handle.It includes all wiring , cabling of required sizes from STP panel board to each electrical parts with on site control panel for individual motors . The panel will consists of following Items as per drawings attached.(Panel shall be of outdoor type installation with suitable IP Protection)
(a) Incomming :-(i) 63Amp,4Pole,MCCB (25KA) with Microprocessor =01 No
(ii) R.Y.B Phase indication lamp with fuse =1 set.
(iii) 0-100 A Digital Ammeter 150/5A Class 10 , 1 set
(iv) 0-500V Digital Voltometer with Control MCB 1 set
(b) Out Going :- (i) 40 Amp, TP MCCB 15KA ICS with automatic star delta Starter as per type -2 cordination with single phase preventer under/ overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 sets (For Two Numbers Air blowers , m3/hr. ( 0.50 wc) 5.0HP motor each).Blower Model Number :AB 4130 (ii) 10A TP MCCB 10KA ICS with automatic DOL Starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set of 2 numbers(One Working +One standby) (For Wet Well Submercible sewer pumps ,Qty : Two Numbers ,2.0 H.P each pump(1 working + one standby) Discharge 2.4 m3/hr.10m head.
(iii) 10A TP MCCB 10KA ICS with automatic DOL Starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set of 2 numbers pumps (One working+one standby) (For Wet Well cutter Submercible sewer pumps ,Qty : two Numbers ,2.0 H.P each pump) Discharge 4m3/hr.10m head. | 1 | Each Job | 1,75,000 ₹1,75,000 Lowest | 5,60,000 ₹5,60,000 |
| 6.01Item no. 6(contd...) (iv) 6A TP MCCB 10KA ICS with automatic DOL Starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -1 nos: (For One number anoxic tank submerged mixer ,1.0 HP each) Model SUZ/RW3033 (v) 10A TP MCCB 10KA ICS with automatic star delta Starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos(One working+one standby) (For Two Numbers RAS pumps ,2 H.P each) 150LPM. (vi) 6A TP MCCB 10KA ICS with automatic star delta Starter as per type -2 cordination with single pahse preventer under/overvoltage protection, overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. - Two numbers (One Working+One Standby) Filter press feed pumps , 0.5 H.P each) (vii) 6A TP MCCB 10KA ICS with automatic star delta Starter as per type -2 cordination with single pahse preventer under/overvoltage protection, overload and short circuit protection,R.Y.B Phase indication lamp with fuse . -2 nos: (For One number Filter Press Hydraulic press machine motor , 0.5 H.P. (viii) 10A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers(One working +one standby) PERMEATE PUMPS 1.5 HP each pump) 3.0 m3/hr. Head : 20mWC (Two numbers ) VFD operated. (ix) 10A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For One numbers Air compressor motor 2.0 HP each pump) 150 LPM , 125 psi pressure. (x) 6A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers (1 Working +One standby) MBR C.I.P Pumps and other fitting parts , 1.0 HP each) | |||||
| 6.02Item no. 6(contd...) (xi) 6A DP MCB 10KA ICS with under/overvoltage protection,overload and short circuit protection, indication lamp with fuse 1 set. -2 nos: (For SIX numbers Pneumatic Valves with flange fitting parts each) (xii) 6A TP MCCB 15KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers CITRIC ACID MIXER ,0.5 HP each) (xiii) 6A DP MCB under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers Hypo Dosing Pumps ) (xiv) 6A TP MCCB 15KA ICS with DOL starter as per type -2 cordination with single pahse preventer uner/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers CITRIC ACID MIXER ,0.5 HP each) (xv) 6A DP MCB under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers Hypo Dosing Pumps ) (xvi) 6A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers Hypo Mixer ,0.5 HP each) (xvii) 6A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers Treated water Distribution Pumps, 3 HP each). (xviii) 6A DP 10 KA for ON line Monitoring System and two number flow meters (xix) 16A DP 10 KA for Spare -03 No for PLC board. (xx) 32A DP 10 KA for Spare -03 No for STP Plant building & Street light. The above panel includes all kind of MCB , MCCB, MPCB, ENERGY METER , Indication Lights , Selector Switches , Push Button. | |||||
Tender Value
₹5.0 Cr
EMD Value
₹5.8 L
Closing Date
22 Oct 2025, 6:00 pmClosed
HQ CHIEF ENGINEER PATHANKOT ZONE
HQ CHIEF ENGINEER PATHANKOT ZONE
PROVISION OF SEWAGE TREATMENT PLANTS (STPs) AT KANDRORI AND AT MIRTHAL UNDER GE (SOUTH) PATHANKOT
2025_MES_707294_2
CA NO CEPZ-18/2024-25
Open Tender
Civil Works
Lump-sum
180 days
GE (SOUTH) PATHANKOT
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
GE (SOUTH) PATHANKOT
₹5.8 L
Yes
14 Nov 2025
11 Sept 2025
29 Oct 2025
11 Sept 2025
22 Oct 2025
8 Oct 2025
Amount
SEWAGE TREATMENT PLANT (75 KLD CAPACITY) Design, supplying, fabrication, installing, testing & commissioning of Pre fabricated package type Sewage Treatment Plant of capacity 75 KLD. The sewage treatement shall be based on MBR technology. The nature of effluent from domestic sewage from toilets and kitchen shall be discharge seperately into the STP. The cost will also include MS puddle flange, Inlet, Outlet, overflow, test line, drain line, by-pass line, vent, foot rest, inspection platform with railing, moving ladder and making support for pipes. Complete Sewage Treatment Plant of capacity 75 KLD to be provided as per the details given in Schedule 'A" Part-I from page No 38 to 42 of CA.
Designing, Supplying, Developing, Installing and Commission SCADA System for 75 KLD Sewage Treatment Plant along with various Automation equipment for STP as indicated and as per details attached. The STP SCADA system shall comprise Complete Sewage Treatment Plant of capacity 75 KLD to be provided as per the details given in Schedule 'A" Part-I from page No 43 of CA.
Supply, Installation , Testing and commissioning of CPRI APPROVED extendable, compartmentalised, front operated , back openable, LT cubicle STP panel having ingress protection of IP 54, suitable for operation on 415 Volt 3 phase 50 c/s power supply fabricated out of 2 mm thick CRCA sheet steel and base channel of MS section not less than 100mmX50mmX5mm, gland plate of 3 mm thick cleaned and treated in 7 tank process and powder coated with approved shade with TPN Electrolytic Aluminium busbar of 200 Amps duly insulated in colour coding & suitable to withstand 25 MVA fault lavel complete with supplying & installation of following equipment including interconnection, control wiring etc as required. All MCCBs shall have microprocessor based release & shall have manually operated handle.It includes all wiring , cabling of required sizes from STP panel board to each electrical parts with on site control panel for individual motors . The panel will consists of following Items as per drawings attached.(Panel shall be of outdoor type installation with suitable IP Protection) (a) Incomming :-(i) 100Amp, 4 Pole, MCCB (25KA) with Microprocessor =01 No (ii) R.Y.B Phase indication lamp with fuse =1 set. (iii) 0-100 A Digital Ammeter 150/5A Class 10 , 1 set (iv) 0-500V Digital Voltometer with Control MCB 1 set (b) Out Going :- (i) 40 Amp, TP MCCB 15KA ICS with automatic star delta Starter as per type -2 cordination with single phase preventer under/ overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 sets (For Two Numbers Air blowers , 110m3/hr. (0.50 wc) 5.0HP motor each).Blower Model Number :AB 4130 (ii) 10A TP MCCB 10KA ICS with automatic DOL Starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set of 2 numbers(One Working +One standby) (For Wet Well Submercible sewer pumps ,Qty : Two Numbers ,2.0 H.P each pump(1 working + one standby) Discharge 3.6 m3/hr.10m head. (iii) 6A TP MCCB 10KA ICS with automatic DOL Starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -1 nos: (For One number anoxic tank submerged mixer ,1.0 HP each) Model SUZ/RW3033
Item no. 3 (contd...) (iv) 10A TP MCCB 10KA ICS with automatic star delta Starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos(One working+one standby) (For Two Numbers RAS pumps ,2 H.P each) 150LPM. (v) 6A TP MCCB 10KA ICS with automatic star delta Starter as per type -2 cordination with single pahse preventer under/overvoltage protection, overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. - Two numbers (One Working+One Standby) Filter press feed pumps , 0.5 H.P each). (vi) 6A TP MCCB 10KA ICS with automatic star delta Starter as per type -2 cordination with single pahse preventer under/overvoltage protection, overload and short circuit protection,R.Y.B Phase indication lamp with fuse . -2 nos: (For One number Filter Press Hydraulic press machine motor , 0.5 H.P. (vii) 10A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers(One working +one standby) PERMEATE PUMPS 1.5 HP each pump) 4.0 m3/hr. Head : 20mWC (Two numbers ) VFD operated. (viii) 10A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection, R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For One numbers Air compressor motor 2.0 HP each pump) 200 LPM , 125 psi pressure. (ix) 6A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers (1 Working +One standby) MBR C.I.P Pumps and other fitting parts , 1.0 HP each) (x) 6A DP MCB 10KA ICS with under/overvoltage protection,overload and short circuit protection, indication lamp with fuse 1 set. -2 nos: (For SIX numbers Pneumatic Valves with flange fitting parts each) (xi) 6A DP MCB under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers Citric Acid Dosing Pumps )
SEWAGE TREATMENT PLANT (50 KLD CAPACITY) Design, supplying, fabrication, installing, testing & commissioning of Pre fabricated package type Sewage Treatment Plant of capacity 50 KLD. The sewage treatement shall be based on MBR technology. The nature of effluent from domestic sewage from toilets and kitchen shall be discharge seperately into the STP. The cost will also include MS puddle flange, Inlet, Outlet, overflow, test line, drain line, by-pass line, vent, foot rest, inspection platform with railing, moving ladder and making support for pipes. Complete Sewage Treatment Plant of capacity 50 KLD to be provided as per the details given in Schedule 'A" Part-I from page No 44 to 48 of CA.
Designing, Supplying, Developing, Installing and Commission STP SCADA System for 50 KLD Sewage Treatment Plant along with various Automation equipment for STP as indicated and as per details attached. The STP SCADA system shall comprise Complete Sewage Treatment Plant of capacity 50 KLD to be provided as per the details given in Schedule 'A" Part-I from page No 49 of CA.
Supply, Installation , Testing and commissioning of CPRI APPROVED extendable, compartmentalised, front operated , back openable, LT cubicle STP panel having ingress protection of IP 54, suitable for operation on 415 Volt 3 phase 50 c/s power supply fabricated out of 2 mm thick CRCA sheet steel and base channel of MS section not less than 100mmX50mmX5mm, gland plate of 3 mm thick cleaned and treated in 7 tank process and powder coated with approved shade with TPN Electrolytic Aluminium busbar of 100A duly insulated in colour coding & suitable to withstand 25 MVA fault lavel complete with supplying & installation of following equipment including interconnection, control wiring etc as required. All MCCBs shall have microprocessor based release & shall have manually operated handle.It includes all wiring , cabling of required sizes from STP panel board to each electrical parts with on site control panel for individual motors . The panel will consists of following Items as per drawings attached.(Panel shall be of outdoor type installation with suitable IP Protection) (a) Incomming :-(i) 63Amp,4Pole,MCCB (25KA) with Microprocessor =01 No (ii) R.Y.B Phase indication lamp with fuse =1 set. (iii) 0-100 A Digital Ammeter 150/5A Class 10 , 1 set (iv) 0-500V Digital Voltometer with Control MCB 1 set (b) Out Going :- (i) 40 Amp, TP MCCB 15KA ICS with automatic star delta Starter as per type -2 cordination with single phase preventer under/ overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 sets (For Two Numbers Air blowers , m3/hr. ( 0.50 wc) 5.0HP motor each).Blower Model Number :AB 4130 (ii) 10A TP MCCB 10KA ICS with automatic DOL Starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set of 2 numbers(One Working +One standby) (For Wet Well Submercible sewer pumps ,Qty : Two Numbers ,2.0 H.P each pump(1 working + one standby) Discharge 2.4 m3/hr.10m head. (iii) 10A TP MCCB 10KA ICS with automatic DOL Starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set of 2 numbers pumps (One working+one standby) (For Wet Well cutter Submercible sewer pumps ,Qty : two Numbers ,2.0 H.P each pump) Discharge 4m3/hr.10m head.
Item no. 6(contd...) (iv) 6A TP MCCB 10KA ICS with automatic DOL Starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -1 nos: (For One number anoxic tank submerged mixer ,1.0 HP each) Model SUZ/RW3033 (v) 10A TP MCCB 10KA ICS with automatic star delta Starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos(One working+one standby) (For Two Numbers RAS pumps ,2 H.P each) 150LPM. (vi) 6A TP MCCB 10KA ICS with automatic star delta Starter as per type -2 cordination with single pahse preventer under/overvoltage protection, overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. - Two numbers (One Working+One Standby) Filter press feed pumps , 0.5 H.P each) (vii) 6A TP MCCB 10KA ICS with automatic star delta Starter as per type -2 cordination with single pahse preventer under/overvoltage protection, overload and short circuit protection,R.Y.B Phase indication lamp with fuse . -2 nos: (For One number Filter Press Hydraulic press machine motor , 0.5 H.P. (viii) 10A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers(One working +one standby) PERMEATE PUMPS 1.5 HP each pump) 3.0 m3/hr. Head : 20mWC (Two numbers ) VFD operated. (ix) 10A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For One numbers Air compressor motor 2.0 HP each pump) 150 LPM , 125 psi pressure. (x) 6A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers (1 Working +One standby) MBR C.I.P Pumps and other fitting parts , 1.0 HP each)
SEWAGE TREATMENT PLANT (25 KLD CAPACITY) Design, supplying, fabrication, installing, testing & commissioning of Pre fabricated package type Sewage Treatment Plant of capacity 25 KLD. The sewage treatement shall be based on MBR technology. The nature of effluent from domestic sewage from toilets and kitchen shall be discharge seperately into the STP. The cost will also include MS puddle flange, Inlet, Outlet, overflow, test line, drain line, by-pass line, vent, foot rest, inspection platform with railing, moving ladder and making support for pipes. Complete Sewage Treatment Plant of capacity 25 KLD to be provided as per the details given in Schedule 'A" Part-I from page No 50 to 54 of CA.
Designing, Supplying, Developing, Installing and Commission STP SCADA System for 25 KLD Sewage Treatment Plant along with various Automation equipment for STP as indicated and as per details attached. The STP SCADA system shall comprise Complete Sewage Treatment Plant of capacity 25 KLD to be provided as per the details given in Schedule 'A" Part-I from page No 55 of CA.
Supply, Installation , Testing and commissioning of CPRI APPROVED extendable, compartmentalised , front operated , back openable, LT cubicle STP panel having ingress protection of IP 54, suitable for operation on 415 Volt 3 phase 50 c/s power supply fabricated out of 2 mm thick CRCA sheet steel and base channel of MS section not less than 100mmX50mmX5mm, gland plate of 3 mm thick cleaned and treated in 7 tank process and powder coated with approved shade with TPN Electrolytic Aluminium busbar of 100A duly insulated in colour coding & suitable to withstand 25 MVA fault lavel complete with supplying & installation of following equipment including interconnection, control wiring etc as required. All MCCBs shall have microprocessor based release & shall have manually operated handle.It includes all wiring , cabling of required sizes from STP panel board to each electrical parts with on site control panel for individual motors . The panel will consists of following Items as per drawings attached.(Panel shall be of outdoor type installation with suitable IP Protection). (a) Incomming :- (i) 63 Amp,4Pole,MCCB (25KA) with Microprocessor =01 No (ii) R.Y.B Phase indication lamp with fuse =1 set. (iii) 0-100 A Digital Ammeter 150/5A Class 10 , 1 set (iv) 0-500V Digital Voltometer with Control MCB 1 set (b) Out Going :- (i) 32 Amp, TP MCCB 15KA ICS with automatic star delta Starter as per type -2 cordination with single phase preventer under/ overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 sets (For Two Numbers Air blowers , m3/hr. ( 0.50 wc) 3.0HP motor each).Blower Model Number :AB 4130
Item no. 9 (contd...) (iii) 10A TP MCCB 10KA ICS with automatic DOL Starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set of 2 numbers pumps (One working+one standby) (For Wet Well cutter Submercible sewer pumps ,Qty : two Numbers ,1.5 H.P each pump) Discharge 4m3/hr.10m head. iv) 6A TP MCCB 10KA ICS with automatic DOL Starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -1 nos: (For One number anoxic tank submerged mixer ,1.0 HP each)Model SUZ/RW3033 (v) 10A TP MCCB 10KA ICS with automatic star delta Starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos(One working+one standby) (For Two Numbers RAS pumps ,2 H.P each) 75LPM. (vi) 6A TP MCCB 10KA ICS with automatic star delta Starter as per type -2 cordination with single pahse preventer under/overvoltage protection, overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. - Two numbers (One Working+One Standby) Filter press feed pumps , 0.5 H.P each) vii) 6A TP MCCB 10KA ICS with automatic star delta Starter as per type -2 cordination with single pahse preventer under/overvoltage protection, overload and short circuit protection,R.Y.B Phase indication lamp with fuse . -2 nos: (For One number Filter Press Hydraulic press machine motor , 0.5 H.P. viii) 10A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers(One working +one standby) PERMEATE PUMPS 1.0 HP each pump) 2.0 m3/hr. Head : 20mWC (Two numbers ) VFD operated. (ix) 10A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For One numbers Air compressor motor 1.0 HP each pump) 100 LPM , 125 psi pressure.
Lumpsum price worked out by the contractor for construction of building as listed in Schedule 'A' Part-II.
Lumpsum price worked out by the contractor for Internal Water Supply as listed in Schedule 'A' Part-III.
Lumpsum price worked out by the contractor for Internal Electric Supply as listed in Schedule 'A' Part-IV.
Lumpsum price worked out by the contractor for Earth work as listed in Schedule 'A' Part-V.
Lumpsum price worked out by the contractor for Pathway as listed in Schedule 'A' Part-VI.
Lumpsum price worked out by the contractor for Fencing & Gate as listed in Schedule 'A' Part-VII.
Lumpsum price worked out by the contractor for Area Drainage as listed in Schedule 'A' Part-VIII.
Lumpsum price worked out by the contractor for External Electric Supply as listed in Schedule 'A' Part-IX.
Lumpsum price worked out by the contractor for External Water Supply as listed in Schedule 'A' Part-X.
Lumpsum price worked out by the contractor for STP Disposal Lines as listed in Schedule 'A' Part-XI.
Material and Labour for disconnecting electric connections, excavation in hard / dense soil by using mechanical earth excavater & mannual labour , taking out old dameged Cable with & including repair to damaged cable by inserting new straight through joint cold shrink type complete with jointing material and accessories to jointing kit for 1100 Volts (Earthed) grade suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25sqmm to 95 sqmm, & including necessary returning filling & removal of surplus spoil a to distance as directed, and make the electric cable line functional to the entire satisfaction of JE & AGE ; complete all as specified and directed by the Engineer-in-Charge.
Material and Labour for disconnecting electric connections, excavation in hard / dense soil by using mechanical earth excavater & mannual labour , taking out old dameged Cable with & including repair to damaged cable by inserting new straight through joint cold shrink type complete with jointing material and accessories to jointing kit for 1100 Volts (Earthed) grade suitable for 3.5 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm, & including necessary returning filling & removal of surplus spoil a to distance as directed, and make the electric cable line functional to the entire satisfaction of JE & AGE ; complete all as specified and directed by the Engineer-in-Charge.
Material and Labour for Disconnecting , dismantling & cutting the existing damaged water supply pipe line bursting/cracks , including excavation in hard / dense soil by using mechanical earth excavater & manual labour , taking out old dameged CI /GI/MS defective or misaligned water supply pipe line of any size carefully after disconnection of joints to a length up to 8 metres and create bund with excavated earth and dewatering / bailing out water from the trenches complete with pumping set and including repair the water supply pipe line by replacing the pipe line up to 8metres of length & inserting necessary CI / GI/MS specials , spares and jointing the pipe line with necessary lead joints and positioning the pipe line after repairs complete t& including necessary returning filling & removal of surplus spoil a to distance as directed, and make the water supply line functional to the entire satisfaction of JE & AGE ; complete all as specified and directed by the Engineer-in-Charge. Note :- (a) The rates quoted for this deemed to included for tool and plant and transportation required for attending the repair work. (b) The breakdown shall be attended within 4 Hrs of intimation round the clock and time of restoration shall be maximum of 8 Hours. The additional manpower required to complete the job in quoted rate is deemed to be included in the quoted.
Material and Labour for disconnecting electric connections, excavation in hard / dense soil by using mechanical earth excavater & mannual labour , taking out old dameged Cable with & including repair to damaged cable by inserting new straight through joint cold shrink type complete with jointing material and accessories to jointing kit for 11000 Volts (Earthed) grade suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm, & including necessary returning filling & removal of surplus spoil a to distance as directed, and make the electric cable line functional to the entire satisfaction of JE & AGE ; complete all as specified and directed by the Engineer-in-Charge.
Material and Labour for disconnecting electric connections, excavation in hard / dense soil by using mechanical earth excavater & mannual labour , taking out old dameged Cable with & including repair to damaged cable by inserting new straight through joint cold shrink type complete with jointing material and accessories to jointing kit for 11000 Volts (Earthed) grade suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm, & including necessary returning filling & removal of surplus spoil a to distance as directed, and make the electric cable line functional to the entire satisfaction of JE & AGE ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing of DBOXx MCB Protected socket With 25 A MCB DBOXX COMBO with sheet steel Enclosure single pole 25 Amp, with 3 pin plug top for AC connection from Socket point to stabilizer ; complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing of LED Lamp 9/10 watt Holder Type B22 Base with polycarbonate body and aluminium heat sink warm white complete all as specified and directed by Engineer - in - Charge.
Material and Labour for disconnecting water supply lines, excavation in hard / dense soil by using mechanical earth excavater & mannual labour , taking out old dameged by cutting existing GI/CI of any size/type of water supply pipe line & including making new connection for PPR pipe including short pieces , inserting tees, bends, sockets, union etc with existing water line & including necessary returning filling & removal of surplus spoil a to distance as directed, and make the water supply line functional to the entire satisfaction of JE & AGE ; complete all as specified and directed by the Engineer-in-Charge.
Material and Labour for Construction of valve chambers of internal size not less than 1000mm X 1000mm X 1050mm with 15cm thick solid concrete block masonary, block casted using PCC 1:3:6 type C-1 mix built in cement and sand mortar (1:4), 10mm thick plaster to thick internal surface and external surface up to 15 cm below ground level and top of floor in cement mortar (1:4) finished surfaces even and smooth without using extra cement, 15mm thick MS sheet cover including 40mm x 40mm x 6mm MS angle frame embedded in 150mm thick PCC 1:2:4 type B-1, with 25mm x 6mm flat iron hold fast, handles, hinges with locking arrangements, & including applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surface , complete including necessary excavation earth work in type of soil , returning filling & removal of surplus spoil a to distance as directed .; complete all as specified and directed by the Engineer-in-Charge.
Material and Labour for Construction of valve chambers of internal size not less than 600mm X 600mm X 600mm with 15cm thick solid concrete block masonary, block casted using PCC 1:3:6 type C-1 mix built in cement and sand mortar (1:4), 10mm thick plaster to thick internal surface and external surface up to 15 cm below ground level and top of floor in cement mortar (1:4) finished surfaces even and smooth without using extra cement, 15mm thick MS sheet cover including 40mm x 40mm x 6mm MS angle frame embedded in 150mm thick PCC 1:2:4 type B-1, with 25mm x 6mm flat iron hold fast, handles, hinges with locking arrangements, & including applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surface , complete including necessary excavation earth work in type of soil , returning filling & removal of surplus spoil a to distance as directed .; complete all as specified and directed by the Engineer-in-Charge.
Supply , Install , Testing & Commissioning of Centrifugal Pumpset of capacity 1.5HP/1KW,3 phase, 415 Volts, 50 Hz, 2900 RPM, min Head range - 25 metres at 312.50 L.P.M flow rate, horizontal type , inlet & outlet size -50mm can withstand wide voltage fluctuation from 200-440 Volts, designed to prevent overloading and motor burntout, dynamically balanced rotating parts to ensure minimum vibratios during running, CED coated cast iron components for rust free & longer life. and motor body & delivery casing made of material- cast iron , shaft- stainless steel including, NRV of suitable size,cable complete all as specified. (01 set including 02 Nos of pumps one working & one standby) ; complete all as specified and directed by the Engineer-in-Charge.
Supply , Install , Testing & Commissioning of Centrifugal Pumpset of capacity 3HP/2.24 KW, 3 phase, 415 Volts, 50 Hz, 2900 RPM, min Head range- 64 metres at 104.17 L.P.M flow rate, horizontal type , inlet & outlet size -50 mm can withstand wide voltage fluctuation from 200-440 Volts, designed to prevent overloading and motor burntout, dynamically balanced rotating parts to ensure minimum vibratios during running, CED coated cast iron components for rust free & longer life. and motor body & delivery casing made of material- cast iron , shaft- stainless steel including, NRV of suitable size, cable complete all as specified. (01 set including 02 Nos of pumps one working & one standby) ; complete all as specified and directed by the Engineer-in-Charge.
Supply , Install , Testing & Commissioning of Centrifugal Pumpset of capacity 4HP/3KW , 3 phase, 415 Volts, 50 Hz, 2900 RPM, min Head range- 25 metres at 350 L.P.M flow rate, horizontal type , inlet & outlet size -50 mm can withstand wide voltage fluctuation from 200-440 Volts, designed to prevent overloading and motor burntout, dynamically balanced rotating parts to ensure minimum vibratios during running, CED coated cast iron components for rust free & longer life. and motor body & delivery casing made of material- cast iron , shaft- stainless steel including,NRV of suitable size, cable complete all as specified. (01 set including 02 Nos of pumps one working & one standby) ; complete all as specified and directed by the Engineer in Charge.
Supply , fixing , Testing & Commissioning of straight through jointing kit, heat shrinkable type suitable for XLPE/ PVC cables of size 10 to 70 Sqmm 3.5/4 core with working voltage 1100 volts ; complete all as specified and directed by the Engineer-in-Charge.
Supply , fixing , Testing & Commissioning of Indoor End jointing kit, heat shrinkable type suitable for XLPE/ PVC cables of size 10 to 70 Sqmm 3.5/4 core with working voltage 1100 volts ; complete all as specified and directed by the Engineer in Charge.
Supply and fixing street light bracket fabricated & made out of GI Tubing light grade 40mm bore Bend to the shape as directed and of length not less than 1.5metres complete fixing on street light poles with & including mounting MS clamps of flat iron of suitable size 02 Nos with necessary nut bolts etc of suitable size ; complete all as specified and directed by the Engineer in Charge.
Supply and fixing weather Proof PVC Junction Box made out of not less than 2 mm thick of size 250mm X 200mm X100mm (approx) complete with hinged door locking arrangement and consisting of 01 No panel mounted connector 4 pole 32 A - 01 No MCB SP 06 Amps 10 KA - 01 No, confirming to IP 65 complete including fixing on street light pole with MS Clamps, bolts, nuts and washers ; complete all as specified and directed by the Engineer in Charge.
Supply and fixing PVC insulated 3 core 2.5 Sqmm stranded Copper conductor cable for connecting junction box to street light fitting testing and commissioning all as directed ; complete all as specified and directed by the Engineer in Charge.
Material & Labour for Constructing brick masonry circular manhole of size 0.91metre internal dia at bottom and 0.60 metre dia at top exceeding 0.90 metre deep and not exceeding 2.00 metres deep with 600mm internal diameter conforming to I.S. 12592 with FPS class designation 75 & brick masonry in cement mortar (1:4) (1 cement :4 coarse sand) using Sewer Bricks , finished internal surfaces of manhole with cement plaster 12mm thick in cement mortar (1:3) (1 cement : 3 coarse sand) & finished with a floating coat of cement , cover will be fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20 mm nominal size) with & including necessary excavation earth work in type of soil , centering, shuttering, orange colour safety foot rest , Curved on plan exc 6m mean radius complete including , returning filling & removal of surplus spoil a to distance as directed .; complete all as specified and directed by the Engineer-in-Charge.
Material & Labour for Constructing brick masonry circular manhole of size 1.22metre internal dia at bottom and 0.60 metre dia at top exceeding 1.50 metre deep and not exceeding 2.50 metres deep with 600mm internal diameter conforming to I.S. 12592 with FPS class designation 75 & brick masonry in cement mortar (1:4) (1 cement :4 coarse sand) using Sewer Bricks , finished internal surfaces of manhole with cement plaster 12mm thick in cement mortar (1:3) (1 cement : 3 coarse sand) & finished with a floating coat of cement , cover will be fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20 mm nominal size) with & including necessary excavation earth work in type of soil , centering, shuttering, orange colour safety foot rest at spacing 300mm centre to centre , Curved on plan exc 6m mean radius complete including , returning filling & removal of surplus spoil a to distance as directed .; complete all as specified and directed by the Engineer-in-Charge.
Supply and laying Rodent Repelent SN-8 DWC ID (HDPE BLACK) Pipe of size 150mm dia with full coupler and rubber ring conforming to IS:16098-2 including testing of joints, comissioning etc ; complete all as specified and directed by the Engineer in Charg. Make: Tirupati/Bestech/ Astral/Ashirwad
Supply and laying Rodent Repelent SN-8 DWC ID (HDPE BLACK) Pipe of size 200mm dia with full coupler and rubber ring conforming to IS:16098-2 including testing of joints, comissioning etc ; complete all as specified and directed by the Engineer in Charg. Make: Tirupati/Bestech/ Astral/Ashirwad
Providing and laying Rodent Repelent SN-8 DWC ID (HDPE BLACK) Pipe with full coupler and rubber ring conforming to IS:16098-2 including testing of joints, comissioning etc. complete of size 300mm diameter : Make: Tirupati/Bestech/ Astral/Ashirwad; complete all as specified and directed by the Engineer in Charge.
M&L for rectification of breakdown of OFC/communication cable including excavation in hard/dense soil by mechanical means/earthmoving equipment or manual labour as required, taking out damaged cable, carrying out repair using suitable jointing kit (complete with jointing material and accessories compatible with existing network), reinstating cable in position, returning, filling, well ramming in layers not exceeding 25 cm, and removal of surplus soil , complete all as specified and directed by the Engineer-in-Charge.
Supply & Fixing for FRP/GRP Manhole cover of size 600mm dia light duty of 2.5 Ton load with Frame of specified sizes & colour , manhole cover with frame load test shall be confirming to IS-1726 & BS EN 124 standards, Colour shall be as approved by Engineer in charge , & including manhole cover shall be engraved with Clients name as confirmed by the Engineer in charge complete with accessories in all respects andnothing shall be paid separately ; complete all as specified and directed by the Engineer-in-Charge. Make: JSN / Dudhi / HP/ Pillon
Supply & Fixing for FRP/GRP Manhole cover of size 600mm dia medium duty of 10Ton load with Frame of specified sizes & colour , manhole cover with frame load test shall be confirming to IS-1726 & BS EN 124 standards, Colour shall be as approved by Engineer in charge , & including manhole cover shall be engraved with Clients name as confirmed by the Engineer in charge complete with accessories in all respects andnothing shall be paid separately ; complete all as specified and directed by the Engineer-in-Charge. Make: JSN / Dudhi / HP/ Pillon
Material & Labour for 50 mm magnetic catches with brass body and striking plate including letting in as fixed ; complete all as specified and directed by the Engineer-in-Charge.
Supply, Install, testing and commissioning of Diesel Engine Driven Generating Set of 30KVA/24KW capacity with alternator out put Voltage 415 Volts +/- 1% at set value of 415Volts at a frequency 50HZ +/- 0.5% with suitable standard control panel, all mounted in acoustic enclosure and Control panel including AMF Panel as per manufacturers design and specification as per approved CPCB-IV Plus norms confirming to the detailed specifications appended below :- (i) ENGINE (a) General: Suitable four stroke compressed ignition, radiator water cooled,Turbocharged aspiration, continuous duty with 10% overload capacity for any one hour in 12 hours running, 50°C intake air temperature, CPCB-IV Plus Euro emission engine developing 268 BHP at 1500 RPM coupled to alternator mounted on Channel Iron base frame with in built fuel tank of minimum capacity suitable for 12 Hrs continous running. The prime mover provided should be as per IS specifications. (b) Air intake system : Should comprise of dry type intake air filter mounted on engine, one in number vacuum indicator mounted on intake piping. (c) Exhaust System: Should comprise of one exhaust manifold, dry type, mounted on engine, one exhaust residential type silencer which should be positioned in such a way that the exhaust gas is not sucked by the fan on the radiator, thereby affecting the cooling system. The silencer should cater to the noise level tolerance prescribed in the relevant IS/BS. The silencer should be provided with flaps with a provision so that it will open only when the generator is running. The complete exhaust system shall be properly supported so that entire lot of the exhaust system shall not fall on the DG Set. (d) Fuel System: Should comprise of disposal type element fuel filter, pressure type fuel pump mounted on engine, non return check valve in fuel supply and drain lines, wire braided hose between filter and pump, fuel system with suitable capacity electronic governor and engine mounted actuator. The fuel tank must have proper locking arrangement with level indicator and to be integrated with base frame.
Item no. 47(contd...) (e) Cooling System: Should comprise of radiator designed and tested for 50oC ambient temperature with 7 PSI pressure cap mounted on base rail. The thermostat installed in the engine coolant outlet, fresh water pump mounted on engine, fan and fan hub mounted on engine. A reservoir of 50% of radiator capacity to replenish coolant by gravity (as and when required) is also to be provided. (f) Lubricating System: Should comprise of lubricating oil sump mounted on engine, gear driven lub oil pump mounted on engine, lubricating oil cooler-fresh water cooled integral with engine cool out circuit mounted on engine, oil filter lubricating with cap and lubricating oil dip stick for oil level check mounted on engine. The system should be capable of feeding lube oil to the main end & large end bearings, cam shaft, valve rocker gear and all moving parts. (g) Starting System: Should comprise of suitable voltage DC electrical starter mounted on engine, with suitable maintenance free batteries of capacity 12/24 V DC with suitable AH to be mounted in trays (having rubber insulation) on the main frame. It should have the provision to charge the battery from external sources during static condition and while running of the generator. (h) AC Generator : The generator shall be horizontal and foot mounted, 30 KVA, 415 Volts, 3 phase, 4 wire, 0.8 PF, 50 HZ, self excited, self regulated, brushless AC generator, suitable for an ambient temperature of 50° C with IP-23 enclosure class H insulation and temperature rise limited to class H as per following technical details (i) Type, Brush less AC Generators (ii) Output rating 30 KVA (iii) Output Voltage: 415 ± 1% under all loading conditions. (iv) Output frequency 50Hz ±0.5% up to 0.8 lagging. (v) No of Phases: 3 phase with 01 Neutral (4 wire) (vi) Mounting : Horizontal foot mounted. (vii) Enclosure : Minimum IP-23 / Drip proof and screen protected. (viii) Automatic voltage regulator. (ix) Class of insulation-'H'
Item no. 47(contd...) (n) Acoustic enclosure: Specially designed to meet CPCB norms 75dBA @ 1 mtr at 75% load under free field conditions. The Acoustic enclosure is made of CRCA sheets and a structural/sheet metal base with high quality noise absorbent and fire-retardant grade acoustic insulation material (P.U.Foam) complying to IS 8183 with two point lifting handles (o) Internal Lighting: Tube lights with protective mesh around it to be fitted inside the container for proper illumination (p) Doors : The enclosure will be provided with suitable doors on the side and rear to enter the enclosure during operation and maintenance. All doors will be provided with lock and handles for opening/ closing the doors, retainers for holding the panel door (q) Painting Scheme ISS shade 220 olive green 1994 or all as per manufacturers specifications (r) Lifting/ Transportation arrangements :- Container with suitable corners will be provided to lift the DG set along with container. This is suitable for road/ rail/ sea transportation. (s) Trials:-Trials on site should be given as per load tests prescribed and all functional trials should be shown. Note : (i) The Engine, alternator, Control Panel, Acoustic enclosure shall be integrated unit sourced from OEM only as per Make. (i) Necessary foundation for installing the DG Set shall be as per manufacturers' recommendation and cost of the same deemed to be included in the quoted rate (ii) Accessories included in manufacturers standard modules are deemed to be included in the quoted rate. Note : This DG Set taken for STP-2 (for Md Accn) and nearest DG Set supply for STP-1 (for single living accn) taken from PH No 11 where the supply of 75 KVA DG from PH No 8 is available.
Supply & fixing of GI strip 32 mm x 6 mm burried in ground; complete all as specified and directed by the Engineer-in-Charge.
Supply, Install, testing and commissioning of Diesel Engine Driven Generating Set of 20KVA/16KW capacity with alternator out put Voltage 415 Volts +/- 1% at set value of 415 V at a frequency 50HZ +/- 0.5% with suitable standard control panel, all mounted in acoustic enclosure and Control panel including AMF Panel as per manufacturers design and specification as per approved CPCB-IV Plus norms confirming to the detailed specifications appended below :- (I) ENGINE (a) General: Suitable four stroke compressed ignition, radiator water cooled,Turbocharged aspiration, continuous duty with 10% overload capacity for any one hour in 12 hours running, 50°C intake air temperature, CPCB-IV Plus Euro emission engine developing 268 BHP at 1500 RPM coupled to alternator mounted on Channel Iron base frame with in built fuel tank of minimum capacity suitable for 12 Hrs continous running. The prime mover provided should be as per IS specifications. (b) Air intake system : Should comprise of dry type intake air filter mounted on engine, one in number vacuum indicator mounted on intake piping. (c ) Exhaust System: Should comprise of one exhaust manifold, dry type, mounted on engine, one exhaust residential type silencer which should be positioned in such a way that the exhaust gas is not sucked by the fan on the radiator, thereby affecting the cooling system. The silencer should cater to the noise level tolerance prescribed in the relevant IS/BS. The silencer should be provided with flaps with a provision so that it will open only when the generator is running. The complete exhaust system shall be properly supported so that entire lot of the exhaust system shall not fall on the DG Set. (d) Fuel System: Should comprise of disposal type element fuel filter, pressure type fuel pump mounted on engine, non return check valve in fuel supply and drain lines, wire braided hose between filter and pump, fuel system with suitable capacity electronic governor and engine mounted actuator. The fuel tank must have proper locking arrangement with level indicator and to be integrated with base frame.
Item no. 49(contd...) (c ) Exhaust System: Should comprise of one exhaust manifold, dry type, mounted on engine, one exhaust residential type silencer which should be positioned in such a way that the exhaust gas is not sucked by the fan on the radiator, thereby affecting the cooling system. The silencer should cater to the noise level tolerance prescribed in the relevant IS/BS. The silencer should be provided with flaps with a provision so that it will open only when the generator is running. The complete exhaust system shall be properly supported so that entire lot of the exhaust system shall not fall on the DG Set. (d) Fuel System: Should comprise of disposal type element fuel filter, pressure type fuel pump mounted on engine, non return check valve in fuel supply and drain lines, wire braided hose between filter and pump, fuel system with suitable capacity electronic governor and engine mounted actuator. The fuel tank must have proper locking arrangement with level indicator and to be integrated with base frame. (e) Cooling System: Should comprise of radiator designed and tested for 50oC ambient temperature with 7 PSI pressure cap mounted on base rail. The thermostat installed in the engine coolant outlet, fresh water pump mounted on engine, fan and fan hub mounted on engine. A reservoir of 50% of radiator capacity to replenish coolant by gravity (as and when required) is also to be provided. (f) Lubricating System: Should comprise of lubricating oil sump mounted on engine, gear driven lub oil pump mounted on engine, lubricating oil cooler-fresh water cooled integral with engine cool out circuit mounted on engine, oil filter lubricating with cap and lubricating oil dip stick for oil level check mounted on engine. The system should be capable of feeding lube oil to the main end & large end bearings, cam shaft, valve rocker gear and all moving parts. (g) Starting System: Should comprise of suitable voltage DC electrical starter mounted on engine, with suitable maintenance free batteries of capacity 12/24 V DC with suitable AH to be mounted in trays (having rubber insulation) on the main frame. It should have the provision to charge the battery from external sources during static condition and while running of the generator.
Item no. 49(contd...) (h) AC Generator : The generator shall be horizontal and foot mounted, 20 KVA, 415 Volts, 3 phase, 4 wire, 0.8 PF, 50 HZ, self excited, self regulated, brushless AC generator, suitable for an ambient temperature of 50° C with IP-23 enclosure class H insulation and temperature rise limited to class H as per following technical details (i) Type, Brush less AC Generators (ii) Output rating 20 KVA (iii) Output Voltage: 415 ± 1% under all loading conditions. (iv) Output frequency 50Hz ±0.5% up to 0.8 lagging. (v) No of Phases: 3 phase with 01 Neutral (4 wire) (vi) Mounting : Horizontal foot mounted. (vii) Enclosure : Minimum IP-23 / Drip proof and screen protected. (viii) Automatic voltage regulator. (ix) Class of insulation-'H' NOTE : Following shall be deemed to be included in cost quoted :- (i) Suitable size RCC cement concrete foundation platform of canopy base with height as required at site to mount the generator as per manufacturer's instructions/ recommendations. The cost of foundation bed incl earth work etc is deemed to be included in the quoted rate. (ii) Connecting existing cables, from existing panels and connecting cables , cables glands, cable lugs to new panel complete with all necessary accessories. (iii) Install on the foundation, connecting fuel lines, cable etc. (iv) Test and commissioning complete (v) The cost of control cables from engine Control panel to AMF panel shall be deemed to be included in the cost quoted. (j) BASE FRAME: Shall be stand by and fabricated with CRCA sheet metal which shall be suitable to mount the engine, alternator and radiator, channel width of base frame shall be adequate to accommodate anti-vibration pads.
Material and labour for cutting into existing CI/GI water supply pipeline of any size and making connection with PPR pipe, including provision of short pieces, insertion of tees, bends, sockets, unions and all necessary fittings, complete with proper jointing to the existing water line, all as specified and directed by the Engineer-in-Charge.
Material and labour for earthing with steel earth plate electrode of size 60cmx60xcmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of Gl strip to earth electrode to the full length of earth plate, Gl medium grade pipe 40 mm bore protection pipe upto test point, 20 mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation, earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-l and all as specified or indicated including testing on completion. Note :- Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RAC cover, funnel with watering pipe, Gl earth strip upto 7.5 m long for connection to test point etc. all as required at site for complete earthing.
Manning & Operation of the STP & SCADA (of capacity 75 KLD, 50KLD & 25 KLD as per srl item No 1 to 9 of this BOQ) for 11 months { PHASE - II refer Sch "A" note no.2.1(b) } , after completion of STP & SCADA :- Operating and keeping thecapacity in running / operational condition by deploying FGM / technical staff to produce the treated effluent of specified quality including Sundays and holidays including all connected electrical & sewage pumps items such as main switch, starter, change over switch, MCCB, voltmeter, ammeter, panel board etc, Sewage water pump, valve system, controlling syatem, daily checking, leakage, checking noise, cleaning of plant and its surrounding area etc for a period of 05 years on yearwise basis including all holidays all as specified and directed by Engr-in-Charge. Note:- (i) Contractor shall deploy one skilled operator (FGM) and one helper per shift in three shift/ day for operation of each STP for period of 05 (Five) years after completion of Phase-I. (ii) The comtractor shall employ FGMs having minimum qualification of ITI from recognised institute having sufficient knowledge and experience of minimum 02 years in maintenance / operation of similar work. The operators must be competent to carry out the repairs / maintenance of plant as required . (iii) The operators shall maintain the desired quality treated water including tracing out and rectification of minor leakages in pipe line / valves during the period. (iv) The operators shall operate elctrical equipement , pumps and maintain the STP in workable condition by checking daily leakages noise, cleaning the plant and its surrounding areas of plant as directed. (v) The contractor shall maintain all registers under various rules, and shall be produced to the Engineer-in-Charge as well as officers detailed by central labour department. (vi) The unit rate quoted shall be deemed to be included for cost of labour for daily for daily routine maintenance for trouble free functioning of installation. (vii) The quoted rate shall be deemed to be inclusive all consumables required for operation of STP. (viii) The payment to the staff employed shall be made within first week of every month through online mode in employees respective Bank Account. No payment to contractors / firms will be made unless proof of payment of wages / EPF / ESI etc through bank account is submitted by the contractor to all employees. Contractor shall produce details of payment made to the employees along with supporting documents for the verification of Engineer-in-Charge for processing the monthly / finall bills. In case of revision in pay slab by Government during the currency of contract, same shall be paid to the employee by the contractor and accordingly rates shall be quoted. Note:- (i) The contracor should follow the terms & conditions of E-in-C's br policy no 10/2023 issued vide letter No A/95533/SCADA Sewage/Pol/E2W (PPC) dt 21 Jul 2023 .(ii) At Kandrori distance between STP-1 & STP-2 approx 2 KM & Mirthal distance between STP-1 & STP-2 approx 0.7 KM. (iii) Approx distance between Mithal and Kandrori Army station is 13 KM. (iv) Necessary spare & manpower will be provides by Contractor.(v) Desired water quality as per standard norms comply with E-in-C's branch direction to be achieved.
All as per srl item No 52 above but Manning & Operation of the STP & SCADA (of capacity 75 KLD, 50KLD & 25 KLD as per srl item No 1 to 9 of this BOQ) for 11 months after completion of Phase-II { Phase-III refer Sch "A" note no.2.1(c) } complete.
All as per srl item No 52 above but Manning & Operation of the STP & SCADA (of capacity 75 KLD, 50KLD & 25 KLD as per srl item No 1 to 9 of this BOQ) for 11 months after completion of Phase-III { Phase-V refer Sch "A" note no.2.1(e) } complete.
All as per srl item No 52 above but Manning & Operation of the STP & SCADA (of capacity 75 KLD, 50KLD & 25 KLD as per srl item No 1 to 9 of this BOQ) for 11 months after completion of Phase-V { Phase-VII refer Sch "A" note no.2.1(g) } complete.
All as per srl item No 52 above but Manning & Operation of the STP & SCADA (of capacity 75 KLD, 50KLD & 25 KLD as per srl item No 1 to 9 of this BOQ) for 11 months after completion of Phase-VII { Phase-IX refer Sch "A" note no.2.1(j) } complete.
All as per srl item No 52 above but Manning & Operation of the STP & SCADA (of capacity 75 KLD, 50KLD & 25 KLD as per srl item No 1 to 9 of this BOQ) for 05 months after completion of Phase-IX { Phase-X refer Sch "A" note no.2.1(k) } complete.
Comprehensive maintenance of the above STP & SCADA (of capacity 75 KLD, 50KLD & 25 KLD as per srl item No 1 to 9 of this BOQ) { Phase - IV refer Sch "A" note no.2.1(d) } ,for the period of 1st years after expiry of Defect Liability Period. The scope of comprehensive maintenance includes maintenance of complete infrastructure under this work and replacing all defective components and restoring any defect / deformity / wear and tear and comprehensive maintenance of all STP components under this job, (Sl item No. 1.00 to 9.00) including all pumps and DG Sets in the scope of entire tender for further period of three years after completion defect liability period. The scope shall also include comprehensive maintenance of all electrical & Sewage Pumps items such as main switch, starter, change over switch, MCCB, voltmeter, anmeter, panel board etc, Sewage water pump, valve system, controlling syatem, daily checking, leakage, checking noise, cleaning of plant and its surrounding area etc, as per manufacturers instructions and as specified and directede by Engr-in-Charge. Note:- (a) Comprehensive maintenance includes replacement of all defective/ worn out / damaged parts including MBR membrane with new parts and nothing extra shall be paid on this account except the payment specified in this item. (b) The contractor shall be responsible for periodic maintenance as per maintenance schedule and specified including renewal/ replacement of parts, lubricants, fittings / fixtures filling of bacteria etc required for smooth functioning of the plant as per manufacturers instructions. (c) The rate quoted shall be deemed to be inclusive of safety gear & required tools for maintenance. (d) The quoted rate is deemed to be inclusive of tool & testing instruments required for operation & maintenance of STP plant. (e) The sludge cakes procured after treatment shall become contractors property and shall be removed from premises of STP as early as possible. The rate shall be quoted accordingly.
All as srl item no.58 above but Comprehensive Maintenance (of capacity 75 KLD, 50KLD & 25 KLD as per srl item No 1 to 9 of this BOQ) for 2nd year after expiry of DLP { Phase - VI refer Sch "A" note no.2.1(f) } complete.
All as srl item no.58 above but Comprehensive Maintenance (of capacity 75 KLD, 50KLD & 25 KLD as per srl item No 1 to 9 of this BOQ) for 3rd year after expiry of DLP { Phase - VIII refer Sch "A" note no.2.1(h) } complete.
M/s R. K. Bhambri (BID ID -3457138)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.98 MB
Tender.pdf
Tender Documents • 5.18 MB
Drgs1.rar
Additional Documents • 20.64 MB
Drgs2.rar
Additional Documents • 21.52 MB
Drgs3.rar
Additional Documents • 22.40 MB
Drgs4.rar
Additional Documents • 36.11 MB
Drgs5.rar
Additional Documents • 31.65 MB
BOQ_817722.xls
BOQ • 0.38 MB
Corrigendum2.pdf
PDF • 1.51 MB
Corrigendum1.pdf
PDF • 0.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .