Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.4 LAccepted-AOC 42 11 DIPKA PALI ROAD DIPKA DIPKA KORBA CHHATTISGARH 495452 | KORBA | CHHATTISGARH | 495452 | ₹1.4 L Quoted ₹1.2 L | L-1 | Accepted-AOC Accepted as the bidder attains L-1 status |
| 2 | L-2₹1.2 L+₹6,760 (5.83%)Rejected-Finance 1ST FLOOR FLAT NO A 104 ANANT EMEGINE SOCIETY PURANA BUS STAND KORBA DISTT KORBA C G 495678 | 495678 | ₹1.2 L+₹6,760 (5.83%) | L-2 | Rejected-Finance Rejected as the bidder attains L-2 status |
| 3 | Rejected-Technical | - | - | Rejected-Technical Rejected due to non-compliance of confirmatory documents |
| Sl No | Description | Qty | Unit | SHASHI BHUSHAN SINGH L1 | AARNA Constructions L2 |
|---|---|---|---|---|---|
| 1.00 | Transportation of poles loading onto departmental truck from stock yard, unloading from truck and shifting from road side to pole pit | 4 | No. | 600 ₹2,400 | 500 ₹2,000 Lowest |
| 2.00 | Shifting of materials other than poles from stockyard to pole pit | 4 | No. | 200 ₹800 Lowest | 400 ₹1,600 |
| 3.00 | Supply and erection of PCC poles 200 Kg, 9 Mtr Long including excavation of pole pit as per site conditions and grouting with OB stone boulder with cement, sand and stone aggregate etc., as required. | 4 | No. | 12,000 ₹48,000 | 11,000 ₹44,000 Lowest |
| 4.00 | Erection/Rectification of stay set complete : Supply of GI stay set, 5/8" X 5 feet, along with all accessories and fixing of stay set with stay insulator including excavation for stay pit and grouting by OB, Boulder and cement | 4 | No. | 6,000 ₹24,000 Lowest | 9,000 ₹36,000 |
| 5.00 | Supplying and erection of disc insulators of 11 KV grade for overhead lines, as required. | 3 | No. | 900 ₹2,700 Lowest | 1,000 ₹3,000 |
| 6.00 | Supplying and erection of pin insulators of 11 KV grade for overhead lines, as required. | 12 | No. | 300 ₹3,600 Lowest | 980 ₹11,760 |
| 7.00 | Dismantling of overhead line comprising of ACSR Rabbit conductor, GI Wire, cross arms, insulators etc as required. | 0.3 | Km | 16,000 ₹4,800 | 7,000 ₹2,100 Lowest |
| 8.00 | Stringing of Rabbit conductor, including un-coiling from drum, transporting to site, laying of conductor along route, stringing and binding on insulators and jumpering and Re-tightening of jumpers and Re-tensioning of conductors as per requirement. (all Three Conductors) | 0.5 | Km | 22,000 ₹11,000 | 9,500 ₹4,750 Lowest |
| 9.00 | Dismantling of 9/11/13 m pole with bracket etc. | 4 | No. | 4,050 ₹16,200 | 3,000 ₹12,000 Lowest |
| 10.00 | Supplying and fixing of MS nut bolt of different size as required. | 5 | Kg | 90 ₹450 Lowest | 100 ₹500 |
Tender Value
₹1.7 L
EMD Value
₹2,200
Closing Date
7 Feb 2026, 5:00 pmClosed
Staff Officer (EnM)
Office of the General Manager, Dipka Area, Ph. No. 9424141353
Temporary diversion of four span of 11KV HT overhead line Renki Feeder of M/s. CSPDCL beside Renki Road, Suwabhodi near mine boundary of Dipka Expansion Project.
2026_SECL_351855_1
SECL/GM/DA/SO(EnM)/ e-tender/25-26/110 dtd-24/01/26
Open Tender
Electrical and Maintenance Works
Item Rate
7 days
Dipka Expansion Project, Dipka Area
Please refer to tender documents
5 documents required · 5 mandatory
₹2,200
18 Apr 2026
27 Jan 2026
9 Feb 2026
27 Jan 2026
7 Feb 2026
28 Jan 2026
27 Jan 2026 - 3 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Transportation of poles loading onto departmental truck from stock yard, unloading from truck and shifting from road side to pole pit | 4 | No. | - | - |
| 2 | Shifting of materials other than poles from stockyard to pole pit | 4 | No. | - | - |
| 3 | Supply and erection of PCC poles 200 Kg, 9 Mtr Long including excavation of pole pit as per site conditions and grouting with OB stone boulder with cement, sand and stone aggregate etc., as required. | 4 | No. | - | - |
| 4 | Erection/Rectification of stay set complete : Supply of GI stay set, 5/8" X 5 feet, along with all accessories and fixing of stay set with stay insulator including excavation for stay pit and grouting by OB, Boulder and cement | 4 | No. | - | - |
| 5 | Supplying and erection of disc insulators of 11 KV grade for overhead lines, as required. | 3 | No. | - | - |
| 6 | Supplying and erection of pin insulators of 11 KV grade for overhead lines, as required. | 12 | No. | - | - |
| 7 | Dismantling of overhead line comprising of ACSR Rabbit conductor, GI Wire, cross arms, insulators etc as required. | 0.3 | Km | - | - |
| 8 | Stringing of Rabbit conductor, including un-coiling from drum, transporting to site, laying of conductor along route, stringing and binding on insulators and jumpering and Re-tightening of jumpers and Re-tensioning of conductors as per requirement. (all Three Conductors) | 0.5 | Km | - | - |
| 9 | Dismantling of 9/11/13 m pole with bracket etc. | 4 | No. | - | - |
| 10 | Supplying and fixing of MS nut bolt of different size as required. | 5 | Kg | - | - |
stage.html
html • 0.04 MB
techsummary_364650.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.62 MB
Tendernotice_2.pdf
PDF • 1.29 MB
Tendernotice_3.pdf
PDF • 0.11 MB
BOQ_364650.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .