Assistant Engineer(Electrical)
FTR HQ BSF North Bengal Kadamtala
CO STORE ROOM FOR BSF PRIMARY SCHOOL AT BSF CAMPUS KADAMTALA UNDER FTR HQ NB. (SH EI and FANS)
2025_BSF_889043_2
5093-5105 dtd 08 Dec 2025
Open Tender
Electrical Works
Works
120 days
FTR North Bengal Kadamtala
As per tender documents
2 documents required · 2 mandatory
₹0
₹3,349
29 Dec 2025
9 Dec 2025
22 Dec 2025
9 Dec 2025
18 Dec 2025
9 Dec 2025
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group B
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed steel conduit as required. (a) 2 X 1.5 Sq.mm + 1 X 1.5 Sq.mm earth wire
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed steel conduit as required. (b) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in existing surface / recessed steel / PVC conduit as required. (b) 3 X 2.5 Sq.mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in existing surface / recessed steel / PVC conduit as required. (c) 3 X 4 Sq.mm
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 12 way, Double door
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.(a) 63 mm dia (OD-63 mm & ID-51 mm nominal)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.(a) Upto 35 sq. mm
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 each blades, 30 cm long down rod, 2 each canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise-75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Providing fixing of of 36 watt 2 x 2 feet Square surface/ recessed mounted LED professional fitting, MIN 100 lm/w for operation on 240 Volt 50 Hz AC supply complete with electronic driver & all accessories etc as required. (Make Crompton/ Havells / Philps /Bajaj Compitable to Crompton make Model no. LCTLSNE-36-FO-CDL)
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
2.pdf
Tender Documents • 1.28 MB
BOQ_934456.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .