Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹7.9 L
EMD Value
₹15,880
Closing Date
28 Aug 2023, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer TLMD-II Pampore
Executive Engineer TLMD-II Pampore
Preventive, Routine and Breakdown Maintenance 132/33 Kv Grid Stations under the Jurisdiction of TLMD-II Pampore
2023_PDD_226852_1
TLMD-II/01 of 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
TLMD-II Pampore
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
Yes
Executive Engineer TLMD-II Pmapore
₹15,880
Yes
29 Aug 2023
19 Aug 2023
29 Aug 2023
19 Aug 2023
28 Aug 2023
19 Aug 2023
Amount
Power Transformer with OLTC:- Inspection and testing of Transformer including drying/replacement of silicagel,checking of Buchholz relay ,surge relay,conservator oil level indicator,Temperature sensors,topping of oil,cooling system ,measurement of IR value,Dielctric strength of oil,cleaning of Transformers etc.
10MVA to 20MVA
20MVA to 50MVA
Dehydration of Transformer Oil
10MVA to 20MVA
20MVA to 50MVA
Replacement of damaged bishing, Bushing Gasket,etc. of Power Transformer including draining of oil, opening of connectors, dismantling of old damaged components and replacement by new ones, providing of connections etc. filling of filtered oil
Bushing rated upto and including 66 kV
Bushing rated above 66 kV upto 132 kV
SF6 Breaker (132KV) :- Inspection and testing of breakers including inspection of operating mechanism,inspection of contacts and adjustment of various clearances including checking/topping of SF6 gas.
VCB (33KV):- Inspection and testing of breakers (VCB)including inspection of operating mechanism,inspection of contacts and adjustment of various clearances .
Current Transformer:- Checking/cleanning and tightning of all electrical connections ,CT secondary terminal, healthiness of secondary terminal bushing, checking/topping of oil , measurement of IR value and tightning of jumpers, arressting of leakages etc.
C.V.T/PTs:- Checking of earthing, healthiness of all gaskets and oil level, measurement of IR value and tightning of all connections and droppers, filling of oil etc.
Surge /Lightening Arrestor:- Checking of leakage cuurent after cleaning of procelain surface, measurement of IR value and tightning of droppers.
Islotaors:-Checking of moving/fixed contacts ,cleaning/greasing of contacts,cleaning of post insulators and auxillary switches,contacts and tightening of clamps etc.
Bus bar:- Replacement of BUS Bars with size up to 0.5 sq.inch. Including replacement of disc insulators if requirred ,tightening of clamps/jumpers.droppers etc.
Replacement of damaged /burnt out droppers/jumpers
Replacement of damaged disc insulators
Replacement of damaged/burnt out clamps of sorts
Column and Beams:- Tightening of all nuts/bolts and providing of missing nuts/bolts and damaged members
Drilling Holes of isolator pad clamps
Illumination System:- Checking of healthiness of fittings in Station buildings, outdoor switch yard, repairing and replacement if required, lighting of pannels, tightening of terminals, maintenance/repairs of hi-mast lights etc.
Battery Bank:- Checking and cleaning of battery cell terminals and accessories , application of petroleum jelly if required, tightening of cell to cell terminals and checking of indiviual cell voltages and terminal voltage including checking of cables.
Battery Charger:- Checking of control cards, measurement of test point voltage values, testing of D.C earth fault and U/V relays , IR measurement of charger transformer checking of earthing etc. checking of charger pannel/D.C.D.B for electrical connections, cleanliness etc.
Protection System:- Checking of relays and application of CCL4 for cleaning, carrying out relay testing replacement of worn out defunct relays, testing of event logger/disturbance recorded if any, checking and replacement of control wiring if required, checking of semaphore and indication lamps etc.
Earthing mat:- Measurement of earth resistivity, checking of electrical continuity of equipment earthings, tightening of earthing connectors, removal of rust from bolted earth connectors and tightening (132/33KV (composite yard).
Cutting /clearing of grass and bushes including uprooting of rank vegetation grass and trees and saplings of girth up to 30cm in the switch yard, store yard.
Replacement of damaged 132KV CT /PT by new one including dismantling of the damaged including making of cabe connections
Replacement of damaged 33KV CT by new one including dismantling of the damaged including making of cabe connections
Replacement of damaged 132KV LA by new one including dismantling of the damaged including making of cabe connections
Replacement of damaged 33KV LA by new one including dismantling of the damaged including making of cabe connections
Replacement of damaged 132 kV SF6 circuit breaker by new one including dismantling of the damaged including making of cabe connections
Replacement of damaged 33 kV Vaccum circuit breaker by new one including dismantling of the damaged including making of cabe connections
Replacement of damaged 132 kV Isolator by new one including dismantlling of the damaged including making of cabe connections
Replacement of damaged 33 kV Isolator by new one including dismantling of the damaged including making of cabe connections
Replacing of 33kV , 400 sqmm, 1-core cable terminination including dismantling of old one
Inatallation of 33kV , 400 sqmm, 1-core cable jointing kit including removing of damaged part
Auxiliary Transformer (33/0.4KV):- Checking & inspection of transformer including drying/replacement of Silica Gel, conservator oil level , topping of oil, Measurement of IR values , dielectric strength of oil & BDV of oil, checking of OLTC, etc. external cleaning of radiators, bushings including arressting of leakages etc.
Replacement of damaged post Insulators or providing additional post insulators.
DG Sets:- maintenance of DG Sets including cleaning of oil and air filters chceking of exhauste system of DG sets, tightening of all mechanical equipments and all electrical connections etc.
Maintenance of ATS Switches, Fire Alaram Systems etc.
Maintenance of deawtering motor punps including replacement of burn out coils etc.
Maintenance /repair of High Masts lights, Air conditioners installed at varoius Grid Sub Stations
Surface dressing of ground(Switch yards) including removing of vegetation and inequalities not exceeding 15cm deep and disposal of rubbish,lead up to 50meters.(All kinds of soil)
Weed/shingle clearance from the cable trenches of switch yards .
M/S IRFAN AHMAD DAR
M/S ALJAN ENGINEERS AND CO
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .