Loading…
Loading…
Tender Value
₹6.8 Cr
EMD Value
₹13.6 L
Closing Date
10 Aug 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
GEN WORKS
25 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
NOTE: If the tender is not accompanied by the certificate(s) in support of financial eligibility as above, the tender shall be rejected. No post-tender correspondence will be entertained.
The tenderer or his site supervisor should have minimum valid 'A' Grade Electrical Contractor's License issued by State Electrical Licensing Board. The License should have been issued on a date prior to the date of Tender opening. Clear scaned copy is to be submitted along with the tender.
Defination of Similar Work :- Works of wiring / cabling or installation and commissioning of electrical items (other than on coaches) such as lights, fans, pumps, charging arrangements, earthing etc (with or without supply of items / equipments) for 230V, 1 phase or 415V, 3phase system or higher voltages.
17 conditions · 6 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The original Bank Guarantee (in lieu of Bid Security) should be delivered in person to the official nominated (i.e Os/Tenders/Engg/____Division) as indicated in the tender document before closing date for submission of bids. (i.e., excluding the last date of submission of Bids)
All the instructions furnished in the Technical Compliance / Commercial Compliance / Custom / Undertakings / General lnstructions / Undertakings are only indicative and not exhaustive. The tenderer shall read the GCC / Tender documents for complete details.
The tenderer shall thoroughly go through the entire tender documents and strictly adhere to the instructions and directions given therein.
Tender value is including escalation of (-) 20% (minus twenty percent) on CPWD DSR rates. Tenderer should note this before quoting the rates.
Electrical Construction-KZJ-KI Section: Electrical arrangements to newly constructing Road No-07 to Road No-15 and Service buildings in DKJ Yard and 2. SPART & SPAMRV Shed with service buildings as a part Phase-II of Kazipet yard modification. 3. KZJ DLS: Wheel Parking Shed, Toilet Complex at DLS-KZJ.
03-2026-27-E-GS-CN
03-2026-27-E-GS-CN
Open
Works - General
6 Months
Unknown (Unspecified Location)
₹0
₹13.6 L
10 Aug 2026
16 Jul 2026
27 Jul 2026
148 items across 63 schedules · ₹2,62,37,214 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Each | 2.00 | 9,02,400 | 18,04,800 | |
| 2 | Each | 2.00 | 15,000 | 30,000 | |
| Item- 02 | supply, Installation, testing and 1600 amps sectionalised olectrolitic the (incoming only) ACB are ACB & DG set MCCB should be indication lamps. LT panel board to IS-2516. The digital type KWH incoming supply and digital type Including with all other connected similar to Legrand (DX3/L&T (AU Betaguard)/C&S Note: MCCBs: with microprocessor released over 1 X 800 Amps 4 pole on load MCCB (For DG set) 4X 400 Amps 4 pole 36 KA MCCB . Note: All | commissioning copper bus should be provided provided with should confirm meter with KWH meter with accessories series)/ABB ICs=100% ICu" type with over change over 4 pole 36 KA MCCBs shouled | of cubicle bar as with Ammeter, to IS-8263, CTs of CTs of etc.., (S200)/Schneider Incoming: current, switch 1 MCCB be | type 14SWG per specification LT Tri-vector voltmeter, ACB's and suitable capacity suitable capacity as directed by (Acti'9) 2 X 800 Amps short circuit, X 800 Amps 4 4 X 200 Amps 4 microprocessor | LT digital selector MCCB's with for Engineer /GE (E 50 KA Earth Fault pole pole 36 based. |
| Schedule total | ₹18,34,800 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
LEDSPECLATESTINDOOROUTDOOR3.pdf LED spec
ATTACHMENT
GCCCORRECTIONSLIPS.pdf
ATTACHMENT
annexures.pdf
ATTACHMENT
Techanicalcirculars-compressed.pdf
ATTACHMENT
GCC CORRECTIONS 5 to 11
ATTACHMENT
GCC 2022 with correction slip
ATTACHMENT
NEFTform.pdf
ATTACHMENT
BGform.pdf
ATTACHMENT
03-2026-27-E-GS-CNTENDERDOC.pdf
ATTACHMENT
IR-GCC2022Updatedwithcorrectionslip.pdf
ATTACHMENT
GCCCORECTIONSLIPsACS-5-11_compressed.pdf
ATTACHMENT
LEDSPECLATESTINDOOROUTDOOR3.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .