Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.7 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹26.0 L+₹2.0 L (8.31%)Rejected-Finance PLOT NO G 36 SECTOR 20 NAVI MUMBAI 400614 | THANE | MAHARASHTRA | 400614 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹27.6 L+₹3.6 L (15.0%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹28.1 L+₹4.1 L (17.1%)Rejected-Finance 15 401 PREM JOT COMPLEX ANIKET CO OP HSG SOC LTD NEAR INDIAN OIL NAGAR GHATKOPAR MANKHURD LINK ROAD GOVANDI CHEMBUR W MUMBAI 400043 | MUMBAI | MUMBAI | MAHARASHTRA | 400043 | L4 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹45,200
Closing Date
9 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MAJ DHANU KUMAR RAI
GARRISON ENGINEER DAMAN TAT RAKSHAK VIHAR DALWADA NANI DAMAN POST DAMAN (UT) PIN 396210
ADDN ALTERATION AND REPAIR TO BASKETBALL COURT AND TENNIS COURT AT ICGAS DAMAN
2021_MES_458899_3
8534/E8
Open Tender
Civil Works
Item Rate
180 days
GARRISON ENGINEER DAMAN TAT RAKSHAK VIHAR DALWADA
CLASS E CATEGORY a (i) and b(i)
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER DAMAN
₹45,200
4 Jun 2022
11 Apr 2022
11 May 2022
11 Apr 2022
9 May 2022
25 Apr 2022
11 Apr 2022 - 21 Apr 2022
60 days
Amount
M&L for removing the existing floor (TENNIS COURT) coal tar treatment by burning the coal tar floor with LPG gas lamp etc. & cleaning the floor etc., complete all as specified and directed.
M&L for cutting / open construction/expansion /dummy / control joints removing existing bitumen /silicon/polysulphide materials etc and applying Epoxy primer and filling with Epoxy resin, hardner & Quartz sand of approved quality , complete, all as specified and directed.
M&L for surface preparation by cleaning the surface from dust, dirt, muck, moisture and all foreign material and cleaned by mechanical means using mechanical scrubber/grinder, chemical treatment for cleaning oil if required followed by application of primer having a volumetric ratio of mixing 2:1 to yeild thickness of 200 micron then providing and applying self-smoothing epoxy screed layer of 1.50mm thickness. The self-smoothing screed shall consist of low viscous epoxy amine cured system and graded aggregate (special silica). The aggregates shall be added in the ratio of 1:2:3. UV resistant, anti skid EPU top coat shall be supplied in pre-weighed packs ready to mix and use which will consist of resin, hardner ,EPI (desired colour concentrate) formulated aggregate+special anti skid silica sand. All these to be mixed in pre-weighed ratio. Agitate the mixture using electrically driven motors and lay the mixture to the thickness of 300 micron then de-aerate by using spike rollers and to allow to cure for a minimum period of 48 hours before trafficking is commenced etc complete all as specified and directed.
Demolition of brick / stone masonry works /concrete work built in cement mortar etc complete all as specified as directed .
Demolition of plain cement concrete unreinforced in any position n.exc 15 cm thick and removal of the same to outside MD land , complete all as specified and directed.
Dismantling of fencing wire mesh, any type complete in position including flat iron and nut bolts etc(erecting on poles) etc omplete all as specified and directed.
M&L for complete removal of existing paint from old steel surfaces by rubbing and preparation of surfaces of any description exc 10cm width or girth by applying one coat of red oxide primer and applying two coats of synthetic enamel paint , complete all as specified and directed.
M&L for complete removal of existing paint from old steel surfaces by rubbing and preparation of surfaces of any description n.exc 10cm width or girth by applying one coat of red oxide primer and applying two coats of synthetic enamel paint etc complete all as specified and directed.
M&L for 100 mm thick cement concrete type B-1 (1:2:4) using 20 mm graded stone aggregage , finished even and smooth without using extra cement etc., complete all as specified and directed.
M&L for burnt brick work using old sized sub class 'B' bricks straight or curved on plan exceeding 6m mean radius and built in CM 1:6 etc complete all as specified and as directed.
Rendering 15 mm thick on brick work or concrete surfaces in cement mortar (1:4 ) finished even and smooth, without using extra cement , complete all as specified and directed.
M&L for newly plastered wall surfaces including chajjahs, parapets and applying two coat of weather proof Acrylic Exterior Emulsion over a coat of primer including making good surfaces complete all as specified and directed.
S&F Galvanized chain link fencing of size 50mm x 50mm x 3mm PVC coated, wt not less then 2.18kg/sqm fixed to posts/strut with bolts and nuts complete all as specified .
M&L for preparation of old plastered surfaces of walls, chajjas, parapets etc by removing the loose materials and filled with crack sealing compound of approved make if necessary and applying one coat of acrylic exterior paint over a coat of exterior grade primer (Brand Apcolite Apex manufactured by Asian Paints or equivalent as approved by GE), as per the manufactures instructions and as directed , etc complete all as specified and as directed.
S&F mild steel grade FE-290 Gde E-165 Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc, wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 etc. , complete all as specified and as directed.
M&L for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 , complete all as specified and as directed.
M&L for preparation of new steel surfaces exc 10cm width or girth and applying two coats of synthetic enamal paint over a coat of red oxide primer , complete all as specified and as directed. .
M&L for preparation of new steel surfaces by applying two coats synthetic enamel paint over a coat of red oxide primer n.exc 10cm in width or girth etc complete all as specified.
Dismantling structural steel work by cutting or suitable means including posts,doors, gates but excluding framed truss etc complete all as specified and directed.
Taking down old unserviceable flood light fitting 70 watt/150watt including FRP looping box, with accessories from poles/walls etc complete all as specified and directed.
Taking down old underviceable cables and accessories from poles/walls etc complete all as specified and directed.
Supply and fix LED flood light luminaire 120 watts with secondary optics made in pressure die cast housing and heat sink in aluminium of IP-66 protection comple with all accessories duly prewired and including fixing arrangement on high mast poles/wall surfaces etc. at any height providing clamps, nuts, bolts and washers etc. including removing old unserviceable items complete all as specified and as directed by Engineer-in-Charge. Make :Halonix Cat P No HLFLD-ML10-120-CWL or equivalent make in SHAKTI/Bajaj/Havells
Supply and fix FRP looping box of size 250x200x105mm with connector and comprising of MCB SP 10 Amps, ISI marked,240V complete with and including providing GI clamps,nuts bolts etc suitable for fixing on PCC pole/ wall etc and including removing old unserviceable item complete all as specified and directed. (FRP Box Make:- National/Sintex,) (MCB Make:- Havells/Standard/ABB/L&T)
Supply,lay and testing LT cable XLPE insulated,galvanised steel strip armoured,1100 volts grade with multistranded aluminium conductor of cross-sectional area 6 sqmm; 2 core laid in trenches/pipes/ducts/walls and connection with necessary cable lugs and glands, nuts, bolts and washers etc and testing including removing old unserviceable item complete all as specified and directed.
Supply, laying in trenches/ducts/along wall/through pipes etc, testing and commissioning LT cable, XLPE insulated, galvanized steel strip armoured, 1100Volts grade with multistranded aluminium conductor of cross sectional area 25 sqmm,3.5 core including making cable connections by providing necessary aluminium lugs duly crimped properly and stainless steel glands, nuts, bolts and washers etc complete in all respects, as specified and directed. Note for Item No 24 & 25 :- (i) Excavation & Earth work, cable protection pipe shall be measured and paid separately. (ii) The cable shall be in one length unless otherwise directed by the GE. (iii) Make for Item No 24 and 25 :- ISI marked in Havells/Polycab/KEI/ Finolex .
Supply, installation, testing and commissioning LT panel board suitable for working on 3 phase, 4 wire, 415 volts, AC, 50Hz Outdoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation, factory fabricated made out of 3.2 mm thick CRCA sheet duly powder coated and shall be CPRI approved and as approved by GE. The Panel shall have front and rear opening, locking arrangement, bus bar chamber and switch gear compartment, hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, aluminium bus bar duly covered with heat shrink sleeves colour coded duly fixed on DMC/SMC insulators, aluminium strip connection from bus bar to outgoing MCCBs and copper conductor cable of adequate size for MCBs, housed in a separate bus bar chamber and control wiring adequate size and length, outgoing MCCBs shall have extended bus bar links and Panel mounted on 50x50x5mm size MS angle iron frame duly painted including PCC 1:2:4 Type B1 (using 20 mm graded stone aggregate) in foundation design subject to approval of GE as per site requirement. The minimum depth, height, width of panel is 450x1800x1500 mm respectively, minimum clearance from ground level is 450mm including removing old unserviceable item complete all as specified and directed and comprising of following :- (a) MCCB 200 Amps, FP, 35 KA, 415 volts, 50Hz-01 No (b) MCCB 100 Amps, FP, 25 KA, 415 volts, 50 Hz-01 No (c) MCCB 63 Amps, FP, 16 KA, 415 volts, 50 Hz-02 Nos (d) MCB 40Amps,DP,10 KA, C series,230 volts,50Hz - 01 No (e) MCB 63 Amps,DP,10 KA, C series,230 volts,50Hz - 01 No (f) MCB 32 Amps,DP,10 KA, C series,230 volts,50Hz - 02 No (g) Digital voltmeter, with VSS-01 set, Digital, Ammeter, with CTs & ASS-01 set (h) LED phase indication lamps RYB-01 set (j) Aluminium bus bar TPN 400 Amps rating-01 set Note :- (i) contractor shall provide CPRI certification of the panel. (ii) All items incorporated in panel is ISI marked . Make for MCCB/MCB :-Havells/Schneider/Standard. Make of LED Lamp:- Teknic,ABB,Legrand/Havells. Make for Amp Meter and Volt Meter :- AE/Kaycee/Havells
Material and labour in repairs for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6.3 mm thick buried directly in ground vertically ( earth pit not less than 2.25 metres deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron strip of size 25 x 4 mm from earth electrode to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate no 3 of SSR Part-I provision of G I Pipe 40mm bore eight grade for protection of GI strip and GI watering pipe of 20 mm bore medium grade,GI funnel with wire mesh,including char-coal, salt packed all around the earth electrode plate in layers,PCC earth pit chamber 1:3:6 type C1,RCC cover 1:2:4 type B1,excavation,earth work in any strata and returning filling, removal of surplus soil and testing for required value, complete all as specified and directed.
Supply,erect and install in true vertical position prestressed concrete pole 9.0 metres long of size 102 x 152 mm at top and 102 x 289 mm at bottom, class10 including painting alternate strips of each 30 cm with black and yellow synthetic enamel paint up to 1.5 meters height from coping and the balance portion of pole shall be painted with two coat of cement based paint. The pole shall be as per approved makes of state electricity board including removing old unserviceable item complete as specified and directed. Note:- Excavation/Earth work, PCC foundation, coping shall be measured and paid separately
Excavation in trenches not exceeding 1.5 metres wide and not exceeding1.5 meters depth for laying of cables, foundation poles, protection pipes etc and getting out in any type of soil all as specified and directed.
Returning filling in soil including spreading leveling watering and well rammimg in layer not exceeding 25 cm thick each layer complete , all as specified and directed
Removing excavated soil not exceeding 50 metres ant depositing where directed at a level not exceeding 1.5 metres above the starting point all as specified and directed
Material and labour for PCC 1:3:6 type C1 using (20 mm graded stone aggregate ) for making good distrubed road surfaces and pole foundation including necessary use and waste of form work complete all as specified and directed
Material and labour for PCC (1:4:8) type D2 using (40mm graded stone aggregate) for making good distrubed road surfaces including necessary use and form work complete all as specified and directed.
Material and labour for PCC 1:2:4 type B1 using (20mm graded stone aggregate) for making good all distrubed surfaces and pole coping including necessary use and waste of form work complete all as specified and directed.
Supply and lay new high density polyethylene DWC pipes of 32 mm dia, 6 kgf/sqcm including all fittings (bends, Tees, Elbows, sockets,'U 'Clip etc) as required on site, complete all as specified and directed. (For cable protection.) Make - Finolex/Reliance/Supreme/Noble or equivalent
Supply and lay new high density polyethylene DWC pipes of 15 mm dia, 6 kgf/sqcm including all fittings (bends, Tees, Elbows, sockets,'U 'Clip etc) as required on site, complete all as specified and directed. (For cable protection.) Make - Finolex/Reliance/Supreme/Noble or equivalent Schedule of credit :- Rs 25,905.00
UBC Engineers Pvt Ltd
Shree Ayyappa Engineering
DARSHAN CONSTRUCTION Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .