Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹3.8 LAccepted-AOC MOHALI PUNJAB 140308 | S A S NAGAR | PUNJAB | 140308 | ₹3.8 L | L-1 | Accepted-AOC Lowest |
| 2 | L-2₹4.2 L+₹40,600 (10.8%)Rejected-Finance | ₹4.2 L+₹40,600 (10.8%) | L-2 | Rejected-Finance Not Lowest |
| 3 | L-3₹4.3 L+₹55,660 (14.8%)Rejected-Finance B 30 JEEVAN VIHAR SHASTRI NAGAR GHAZIABAD UTTAR PRADESH 201001 | GHAZIABAD | UTTAR PRADESH | 201001 | ₹4.3 L+₹55,660 (14.8%) | L-3 | Rejected-Finance Not Lowest |
| 4 | L-4₹4.8 L+₹1.0 L (26.6%)Rejected-Finance | ₹4.8 L+₹1.0 L (26.6%) | L-4 | Rejected-Finance Not Lowest |
| 5 | Rejected-Technical H 27 UPPER GROUND FLOOR MOHAN GARDEN UTTAM NAGAR NEW DELHI DELHI 110059 | WEST | DELHI | 110059 | - | - | Rejected-Technical Experience certificates are not as per NIT requirement |
Tender Value
₹4.5 L
EMD Value
₹9,000
Closing Date
9 Jun 2023, 5:00 pmClosed
Director
CSIR CSIO Sector 30 Chandigarh
Retrieval and shifting of electrical installations and Other miscellaneous
2023_CSIR_155646_1
CSIO/84/2022-23/Elect.
Open Tender
Electrical Works
Item Rate
90 days
CSIR CSIO Sector 30 Chandigarh
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹9,000
18 Aug 2023
29 May 2023
13 Jun 2023
29 May 2023
9 Jun 2023
29 May 2023
Amount
Disconnection of end termination with compression gland up to 3.5 core 400 Sq.mm Aluminium conductor power cable as directed by Engineer-In-Charge.
Dismantling of power cable aluminium conductor up to 3.5 core 400 Sq.mm from the existing cable tray/surface/duct and shifting of the same from site to store as directed by Engineer-In-Charge.
Digging of ground up to 1 meter depth and removal of power cable aluminium conductor up to 3.5 core 400 Sq.mm from existing cable trench as directed by Engineer-In-Charge.
Dismantling of metallic cable trey up to size of 600mm Width from existing wall/roof and shifting the same from site store as directed by Engineer-In-Charge.
Disconnection of out going cables with end termination & cable glands from electrical switchgears, earthing in the control panels, dismantling and shifting electrical control panel of size 2.15M X1.60M X0.30M from site to store including making arrangement of crane/lifter/vehicle as directed by Engineer-In-Charge.
Disconnection of out going cables with end termination & cable glands from electrical switchgears, earthing in the control panels, dismantling and shifting electrical control panel of size 2.5M X1.95M X0.30M from site to store including making arrangement of crane/lifter/vehicle as directed by Engineer-In-Charge.
Disconnection of out going cables with end termination & cable glands from electrical switchgears, earthing in the control panels, dismantling and shifting electrical control panel of size 1.50M X1.64M X0.25M from site to store including making arrangement of crane/lifter/vehicle as directed by Engineer-In-Charge.
Disconnection of out going cables with end termination & cable glands from electrical switchgears, earthing in the control panels, dismantling and shifting electrical control panel of size 1.36M X1.20M X0.30M from site to store including making arrangement of crane/lifter/vehicle as directed by Engineer-In-Charge.
Disconnection of out going cables with end termination & cable glands from electrical switchgears, earthing in the control panels, dismantling and shifting electrical control panel of size 1.50M X1.60M X0.25M from site to store including making arrangement of crane/lifter/vehicle as directed by Engineer-In-Charge.
Disconnection, dismantling & shifting of bulkhead industrial fitting from the ceiling of the building up the height of 20 to 24 feet as requited at site and directed by Engineer-In-Charge.
Supply, installation, testing & commissioning of Switch Fuse Unit Box with aluminium bus bar chanber of TPN 250Amp. made of 1.6mm thick sheet steel enclosure duly painted with powder coating (Apx. size : 450mm x 950mm x 275mm) fully PVC insulated 4 Nos aluminium bus bars in convenient sections and suitable for 415 volts, 3 phase, 4 wire, 50 Hz, A.C. supply and earthing with 2 runs of galvanised iron strips etc. as required
Supply, installation, testing & commissioning ofmetalic enclosure sutable FOR TPN 250Amp. MCCB made of 1.6mm thick sheet steel enclosure duly painted with powder coating (Apx. size : 300mm x 225mm x 100mm) as required .
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required : 250 Amp, 25 KA, TPMCCB
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required: Above 120 sq. mm and upto 400 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required : 3½ X 70 sq. mm (38mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required : 3½ X 185 sq. mm (57mm)
Disconnection of 3 phase cable connection of machines up to 5HP, 3 phase motor connections including earthings, cutting the Kota stone/marble floor, supply and fixing of the PVC conduit pipe of size up to 100mm dia. up to 1.5 meter length making good the same and relaying the power cable in same PVC pipe, making connections of power supply cable to machine, connection of earthing including minor civil work including material as required at site
VIKAS ENTERPRISES
B S ELECTRICALS
SSPL Enngineers & Contractors
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .