GE (AF) FARIDABAD
GE (AF) FARIDABAD
PROVISION OF ELECTRIFICATION FROM DATA CENTRE TO MAIN RECEIVING STATION AT MCC BASANT NAGAR UNDER AOR OF GE (AF) FARIDABAD
2026_MES_798423_1
GE (FBD)/AF-T-80/2026-2027
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Delhi
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) FARIDABAD
₹85,100
Yes
12 Nov 2026
12 Nov 2026
5 Dec 2026
12 Nov 2026
3 Dec 2026
26 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches in hard/dense soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth for laying of cables/poles or foundation etc and getting out complete all as specified and directed. | 143.64 | Cum | - | - |
| 2 | Returning, filling, including spreading levelling and well ramming in layers not exceeding 25cm apart complete all as specified and directed. | 99.79 | Cum | - | - |
| 3 | Removing of surplus excavated soil to a distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed. | 43.85 | Cum | - | - |
| 4 | M&L for sand cushoning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable and punned down 100mm to trenches complete all as specified and directed. | 28.73 | Cum | - | - |
| 5 | M&L for reinforced precast concrete cable cover, bricks for cable protection Class HV, Type I, flat, size 300mm x 180mm x 40mm complete all as specified and directed. | 1,773 | Per Nos | - | - |
| 6 | Supply, installation, testing, and commissioning of 11KV Outdoor duty (IP 54 enclosure) SF6 gas insulated 3-way motor operated Ring Main Unit comprising of 1 nos. 630 Amps Load Break Switches and 2 No, 630 Amps Vacuum Circuit Breaker, cable termination from the front, breaking capacity 21KA/3sec (Internal Arc Classification ALF-R 21kA-1sec with for tank and cable box as per IEC 62271-200), enclosed in robotically welded stainless steel tank having IP67 Degree of Protection, leak rate of SF6 gas less than 0.1% and tested as per IEC 60056/60694/60298. PT should be mounted only in rear side (top or bottom of the panel). Protection CTs shall be ring core type, complete all as specified and directed. | 1 | Each Job | - | - |
| 7 | (A) NOTE:- Others details:- System Particulars: (i) Nominal System Voltage : 11kV. (ii) Voltage variation on supply side : ±10 %. (iii) Corresponding Highest System Voltage: 12kV. (iv) Frequency : 50 Hz with ± 3 % tolerance. (v) Transient condition : -20 % or + 10 % combined variation of Voltage and frequency. (vi) Number of Phase : 3 Phases. (vii) Neutral earthling : Solidly earthed. (viii) Fault level (minimum) kA /Sec : 21/3). (ix) Lightning Impulse Withstand Voltage (kVp) : 75 (x) One minute dry/wet power frequency withstand voltage primary (kV rms) : 28KV (xi) Rated Dynamic Withstand Current for 1 second duration (kAp) : 52.5KA. (xii) Earth switch with its own making capacity independent of breaker with won snap action mechanism for fast closing independent of operator action (E2 Class). | - | - | - | - |
| 8 | (B) Applicable Standards for this RMU scope of work. (i) The design, manufacture and performance of the Ring Main Units shall comply with all currently applicable statutes, regulations and safety codes.Nothing in this specification shall be construed to relieve the bidder off his responsibilities. (ii) Unless otherwise specified, the Ring Main Units shall conform to the latest applicable, IEC 62271-100, IEC 62271-200. (iii) All live parts, bus bars, shall preferably be robotically welded non magnetic and non ferrite grade stainless steel tank Grade SS304 of minimum 2.5 mm thickness.The RMU shall be type tested for internal arc test of 21KA/1 sec AFLR as per IEC62271-200. The outer enclosure shall cover the full length of the switch gear, to ensure IP54 protection for full door covering of complete switchgear. The protection relay shall be for 3 O/C + 1E/F (IDMT Type) Self powered numerical protection relay with low and high set of over current and earth fault ,(iv) No additional plate/ accessories to be add to achieve Internal Arc of the Cable of 21kA-1sec, in the cable box chamber. RMUs should be manufactured, inspected and invoiced from the OEM factory only; no licensee partner manufactered RMU is acceptable. (v) The SF6 gas filled 11 kV, 630 Amps, extensible type, Outdoor, SCADA compatible Motorized Ring Main Unit with Vacuum Circuit Breaker to be supplied against this specification shall be suitable for satisfactory continuous operation under the following tropical conditions, design ambient temperature (Degree C) 40 as per IEC.
Note :- Rate of required excavation and PCC foundation as per OEM recommendation should be deemed to be included in quoted rates. | - | - | - | - |
| 9 | Supply, Installation, testing, and commissioning of 11KV Outdoor duty (IP 54 enclosure) SF6 gas insulated 4-way motor operated Ring Main Unit comprising of 2 nos. 630 Amps Load Break Switches and 2 No, 630 Amps Vacuum Circuit Breaker, cable termination from the front, breaking capacity 21KA/3sec (Internal Arc Classification ALF-R 21kA-1sec with for tank and cable box as per IEC 62271-200), enclosed in robotically welded stainless steel tank having IP67 Degree of Protection, leak rate of SF6 gas less than 0.1% and tested as per IEC 60056/60694/60298. PT should be mounted only in rear side (top or bottom of the panel). Protection CTs shall be ring core type, complete all as specified and directed. | 1 | Each Job | - | - |
| 10 | (A) NOTE:- Others details:- System Particulars: (i) Nominal System Voltage : 11kV. (ii) Voltage variation on supply side : ±10 %. (iii) Corresponding Highest System Voltage: 12kV. (iv) Frequency : 50 Hz with ± 3 % tolerance. (v) Transient condition : -20 % or + 10 % combined variation of Voltage and frequency. (vi) Number of Phase : 3 Phases. (vii) Neutral earthling : Solidly earthed. (viii) Fault level (minimum) kA /Sec : 21/3). (ix) Lightning Impulse Withstand Voltage (kVp) : 75 (x) One minute dry/wet power frequency withstand voltage primary (kV rms) : 28KV (xi) Rated Dynamic Withstand Current for 1 second duration (kAp) : 52.5KA. (xii) Earth switch with its own making capacity independent of breaker with won snap action mechanism for fast closing independent of operator action (E2 Class). | - | - | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
Tenderdocu80.pdf
Tender Documents • 1.00 MB
BOQ_895678.xls
BOQ • 0.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .