Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC 31 TILAK NAGAR SRI GANGANAGAR 335001 RAJ | GANGANAGAR | RAJASTHAN | 335001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹9.4 L+₹1,259 (0.13%)Rejected-Finance | L2 | Rejected-Finance Highest bid quoted other then L1 | |
| 3 | L3₹9.9 L+₹44,455 (4.71%)Rejected-Finance | L3 | Rejected-Finance Highest bid quoted other then L1 | |
| 4 | L4₹10.0 L+₹53,288 (5.65%)Rejected-Finance | L4 | Rejected-Finance Highest bid quoted other then L1 |
Tender Value
Refer Docs
EMD Value
₹29,720
Closing Date
14 Nov 2022, 6:00 pmClosed
GE Sri Ganganagar
Garrison Engineer Sri Ganganagar, Military Engineer services , Sri Ganganagar Cantt Rajasthan-335001
REPAIR/MAINTENANCE OF STREET LIGHTS AT MILITARY STATION SRI GANGANAGAR
2022_MES_558301_1
GE SGNR/TOK-47 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Sri Ganganagar(Raj)
E Class b(i) and for un-enlisted, refer NIT para 8.
6 documents required · 6 mandatory
₹500
GE Sri Ganganagar
₹29,720
Yes
11 Jan 2023
18 Oct 2022
16 Nov 2022
18 Oct 2022
14 Nov 2022
25 Oct 2022
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out or for laying underground cable etc. in soft/loose soil, including getting out bricks complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in soft/loose soil complete all as specified and directed by Engineer-in-Charge
Removal of excavated surplus soil to a distance n.exc 50m and depositing where directed at level n.exc 1.5 m above the starting point complete all as specified & directed by Engineer-in-charge .
M & L for sand cushioning with dry coarse canal sand to under ground cable 23 cm thick, 8 cm thick below the cable and 15 cm thick after laying the cable complete all as specified and directed by Engineer-in-Charge. Note : Thickness after punning shall be considered for payment.
M & L for brick protection with old size sub class 'B' bricks laid flat , length of bricks across the route of underground cable complete all as specified and directed by Engineer-in-Charge.
Taking down existing unserviceable security/street light, high mast lights, globe lights, guarden lights of any capacity/size from existing pole, bldg, wall for replacement of unsv fitting complete including checking of electric circuit for security/street light, high mast lights, globe lights, guarden lights complete all as specified & directed by Engineer-in Charge. Note: Contractor supervisor will receive complant each working day from JE E/M and will rectify the total no of complaints given to him the same day and feedback to JE E/M daily evening, failing which a recovery of Rs 20 per day/ light will be made, contractor will deploy etectrication/ helper will be made on the account, contractor will ensure all safety accesseries,T&P will be provide to the labour employed
S&F in replacement, new generation energy saving & environmental friendly long life versatile pressure die cast aluminium IP67 roadway luminaire 45 watt with high power LEDs as light source and electric driver including PVC insulated two core 1.5 Sqmm FRLS multistranded Al conductor cable for connection complete all as specified & directed by Engineer-in Charge. Make : Havells Cat No. : LHETAXU7PN6W045/Bajaj Cat No. BRTFG45W LEDI / Crompton cat part no- LSTO2G-45/CDL
S&F in replacement Endura Highbrite Energy saving, environmental friendly. Long life exclusive innovative die-cast aluminium IP67 flood light with high power LEDs as light source, suitable for highlighting archtectural features 150 W LED complete all as specified & directed by Engineer-in Charge. Make : Bajaj Cat Part No.BALFEG-150W LED / Havells cat part No LHEPCZU7P46J150
S&F in replacement, new generation energy saving & environmental friendly long life versatile pressure die cast aluminium IP67 roadway luminaire 70 or 72 watts with high power LEDs as light source and electric driver including testing complete all as specified & directed by Engineer-in Charge.
S&F in replacement, globe light with retrofit 5/6 walls LED lamp complete all as specified & directed by Engineer-in Charge.
M & L in replacement of PVC insulated, armoured heavy duty electric cable with multi-stranded aluminium conductor 1100 volts grade cross sectional area 10sqmm 2 core complete all as specified and directed by Engineer-in-Charge.
M & L in replacement of PVC insulated, armoured heavy duty electric cable with multi-stranded aluminium conductor 1100 volts grade cross sectional area 10sqmm 4 core complete all as specified and directed by Engineer-in-Charge.
M & L in replacement of PVC insulated, armoured heavy duty electric cable with multi-stranded aluminium conductor 1100 volts grade cross sectional area 16sqmm 4 core complete all as specified and directed by Engineer-in-Charge.
M & L in replacement of PVC insulated, armoured heavy duty electric cable with multi-stranded aluminium conductor 1100 volts grade cross sectional area 25sqmm 4 core complete all as specified and directed by Engineer-in-Charge.
S&F in replacement street light time, single phase for 5 KW light load comprising of nature switch, contractor and MCB housed in a pole mountable enclosure complete all as specified and directed by Engineer-in-Charge. (Make : Swadeep 0EC 5KW1P/ or equivalent in /indo Asian/Bajaj/L&T/C&S.
M & L in replacement of PVC insulated, PVC sheated Aluminium conductor electric cable 2.5sq mm 3 Core 11 volts grade for existeing street light fitting on pole all as specified and directed by Engineer-in-charge
Supply and fix in replacement of GI pipe 50 mm bore light grade for protection of cable including provision of clampsm nut, bolts etc required for fixing pipe along pole / wall / laid under the road / laid under the floor or in trenchees complete all as specified and directded by Engineer-in-Charge
M&L for preparation of old surfaces of PCC poles and applying two coats of synthetic enamel paint with black & white or yellow colour strips 30cm each up to 1.5 mtr height from top of PCC foundation block and numbering of poles with synthetic enamel paint white in 80 mm high letters 150 mm ablve the top strip complete all as specified and directded by Engineer-in-Charge
M&L for preparation for old surface of steel tubular pole any size and type of poles and appluiong two coat aluminium paint over red oxide primer and applying two coats of synthetic enamel paint with black & white or yellow colour strips 30cm each up to 1.5 mtr height from top of PCC foundation block and numbering of poles with synthetic enamel paint white in 80 mm high letters 150 mm above the top strip complete all as specified and directded by Engineer-in-Charge
M/L for GI clamp, GI nutl bolt, fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts, in any shape or size all as specified and directded by Engineer-in-Charge
S&F in replacement, pole mounting box of size 240x160x110 mm, shockproof, dustproof, wheatherproof, including pole mounting arrangement such as clamp made of MS flat 3x25 mm size & nut bolts and washer, two way connector suitable for single phase supply, MCB SP 2.5 A 'B' curve, as per IS 10192 complete all as specified and directed by Engineer-in-Charge.
S&F in replacement, pole mounting box of size 300x200x105 mm, shockproof, dustproof, wheatherproof, including pole mounting arrangement such as clamp made of MS flat 3x25 mm size & nut bolts and washer, two way connector suitable for single phase supply, MCB SP 2.5 A 'B' curve, as per IS 10192 complete all as specified and directed by Engineer-in-Charge.
S&F in replacement street light timer, Three phasw for 5 KW light load comprising of nature switch, contractor and MCB housed in a pole mountable enclosure complete all as specified and directed by Engineer-in-Charge. Make : Swadeep 02 EC 8KW3P/ or equivalent in / Indo Asain / Bajaj / L&T/C&S
M&L for preparation for old surface of steel tubular poles any length and applying two coat of aluminum paint complete, including scrappin of old painted surface and one coat of red oxide paint all as specified and directded by Engineer-in-Charge
Supply and fixing on existing pole from street light fitting/LED bollard light/LED garden light with replacement of New LED street light driver capacity up to 35 watt and support to existing light ie Haveels, crompton, Philips, Bajaj etc and existing light make to serviceable with 01 years replaement warranty.
Supply and fixing on existing pole from street light fitting with replacement of New LED street light driver capacity up to 40 to 50 watt and support to existing light ie Haveels, crompton, Philips, Bajaj etc and existing light make to serviceable with 01 years replaement warranty. complete all as specified and directed by Engineer-in-Charge.
Supply and fixing on existing pole from street light fitting with replacement of New LED street light driver capacity up to 60 to 75 watt and support to existing light ie Haveels, crompton, Philips, Bajaj etc and existing light make to serviceable with 01 complete all as specified and directed by Engineer-in-Charge.
Supply and fixing on existing pole from street light fitting / High Mast light fitting with replacement of New LED street light driver capacity up to 120 to 180 watt and support to existing light ie Haveels, crompton, Philips, Bajaj etc and existing light make to serviceable with 01 complete all as specified and directed by Engineer-in-Charge.
M&L for in replacement Earthing complete with galvanized earth plate electrode 600 x 600 x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of earth plate at a depth of not less than 1.5 meter deep below normal ground level connected to and including galvanised Earth lead wire 4 mm dia by7 means of nuts, bolts & washers of GI or steel and adequate quantity of salt and charcoal. complete all as specified and directed by Engineer-in-Charge. Notes: - (i) GI strip up to earth test point/equipment is included in this item. (ii) Outer edge of earth pit chamber shall be 1.5 meter away from the outer edge of PCC chamber.
S&F in replacement motor for high mast light of suitable cap in HP including repair to which to lift and lower the high mast light including arrangement for replacement of pinion/gear box, chain, wire etc to make the high mast light servicable complete all as specified and directed by Engineer-in-Charge.
Cutting/ trimming of tree branches not exc 10cm girth touching/ approaching the LT/HT overhead lines with hack saw/axe to clear the LT/HT line upto 3 metre on each side (Horizontal and / or vertical) including disposal of trimmed branches 2 KM away inside the Military station area & clearing site complete all as specified and directed by Engineer-in-Charge. Note :- 3 metre width on each side of LT/HT line shall be cleared and each span having not less than 3/5 conductors and min30-40 m pole to pole distance shall be measured as each span
Notes : (i) Amount of credit for retrieved materials is mentioned in Sch 'A' Section-II of tender documents in pdf form which will be deducted while acceptance of tender offline. (ii) All light and driver make to servicable with 01 year replacement warranty. The contracotr will liable for penalty of Rs 500/day if he fail to interain the complaint given to him on next day.
SILEWAL CONTRACTOR & SUPPLIER
Ganganagar Enterprises
DASHMESH ENTERPRISES
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .