Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.9 LAccepted-AOC DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹48.9 L+₹2.0 L (4.29%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹49.7 L+₹2.8 L (6.05%)Rejected-Finance | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹50.3 L+₹3.4 L (7.27%)Rejected-Finance | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹50.9 L+₹4.0 L (8.61%)Rejected-Finance 2 FLAT NO 2 B GEETHANJALI CLASSIK APARTMENT 9TH CROSS KAGGADASAPURA CV RAMAN NAGAR BANGALORE 560 093 | BENGALURU URBAN | KARNATAKA | 560093 | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
8 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
CERTAIN SANCTIONED WROK AT DOMESTIC AND TECHNICAL AREA AT AFS SULUR
2020_MES_345693_1
8317/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE AF SULUR
₹97,000
Yes
15 Jun 2020
18 May 2020
9 Jun 2020
18 May 2020
8 Jun 2020
1 Jun 2020
18 May 2020 - 30 May 2020
60 days
Amount
SCHEDULE A BOQ
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M deep in hard soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing of soils to a distance exceeding 1.5 KM but not exceeding 5KM and depositing where directed complete all as specified and directed.
Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded granite stone aggregate) in foundation, filling and mass concrete complete all as specified and directed
Moorum/ red bajri filling in floors or paving’s, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed
Hard core of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed
Plain cement concrete (1:3:6) type C-2 (40mm graded stone aggregate) 150 mm thick as in path/hardstanding to recive tiles all as specified and directed.
Brick work with fly ash' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 complete all as specified and directed.
Rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement complete all as specified and directed.
Rendering 15 mm thick in two layers on brick or stone or concrete surfaces, first coat 10mm thick in cement mortar 1:6 and 2nd coat 5mm thick in cement mortar 1:4 mixed with water proofing compound as per manufacturer instructions finished even and smooth without using extra cement complete all as specified and directed. Note: Water proofing compound shall be measured and paid seperately.
Supply only Integral liquid water proofing compound
Reinforced Cement Concrete Type B1 1:2:4 (using 20 mm graded granite stone aggregate) cast in situ in lintels up to 1.5 M span, cills and other similar bands, plinth courses, parapets, copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating as directed including use and waste of form work complete all as specified and directed.
Reinforced Cement Concrete Type B1 1:2:4 (using 20 mm graded granite stone aggregate) cast in situ in lintels above 1.5 M span, cills and other similar bands, plinth courses, parapets, copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating as directed including use and waste of form work complete all as specified and directed.
Deformed TMTsteel bar of grade Fe-500/500D , 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed.
All as per item No. 15 but 5mm dia and over up to and including 10 mm dia in stirrups, spacers and binders.
Rolled sections confirming to Fe-41 W Gde – E250 as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates all as directed by the Engineer-in Charge
Applying two coats of cement based paint over and including a coat of primer including preparation of new plastered wall surfaces of any description, complete all as specified.
12mm thick toughened glass for doors including polished by machine on edges including stainless steel clips/hinges, stainless handles (02 Nos), floor spring double action complete all as specified and as directed by Engr-in-Charge (Make : Saint Gobin/ESG/Modi)
Pressed steel frames 165x60mm for doors with one or more rebates including necessary fixing lugs hinges, lock strike plate etc, complete, as specified
Pre painted Coloured Galvalume roofing system corrugated sheet 0.50 mm thick having Zinc aluminum alloy coating AZ150 shall be as per IS:277/ASTM 1379 150 gsm/ sqm double ribbed trapezoidal profile steel sheet any colour having tensile strength of 550 Mpa as in Roof covering /cladding to wall fixed with self tapping screws complete all as directed.
Pre painted Coloured Galvalume roofing system corrugated sheet 0.50 mm thick having Zinc aluminum alloy coating AZ150 shall be as per IS:277/ASTM 1379 150 gsm/ sqm double ribbed trapezoidal profile steel sheet any colour having tensile strength of 550 Mpa as in Roof covering /cladding to wall fixed with self tapping screws including taking down existing sheet complete all as directed.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified
Note for Pre-painted coloured Galvalume roofing :-
(i) The manufacturer's test certificate and individual test certificate for the chemical and mechanical properties of sheet must be submitted for approval by the concerned authority prior to installation.
(ii) The contractor shall ensured that no leakages take place from the roof. The roofing shall be Coloured Galvalume roofing system (olive green colour or as approved by GE) with feed material manufactured from 0.50 mm Total coated thickness (TCT), minimum 550 MPa yield strength and shall conform to the physical specifications of IS: 2062 of 2011, coated with hot dip metallic Aluminium / Zinc alloy coating AZ150 as 150 gm/sq.mt total on both sides.
(iii) The painting shall be coloured baked enamel polyester with silicon coating of film thickness 25 microns nominal on the exposed face/exterior side and on the reverse side ( interior face) shall be white with 15 microns film thickness, over a coat of 5 micron nominal thickness Primer.
(iv) The contractor shall produce purchase vouchers for each lot for verification of Engineer-in-Charge.
(v) The unit rate is deemed to be including for Crimp curves for parking shed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Steel 1.00mm thick rolling shutters, with gear operated type with bevel gear box and crank handle as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type, fixed including taking down existing one all as specified
Aluminium powder coated of three track sliding window outer frame top & sides (section no-20831) of size 92.0x31.75x1.5mm weighing 1.06 Kg/m, frame bottom (Section No 20832) of size 92.0x31.75x1.5mm weighing 1.248Kg/m , shutter to plain vertical (Section No 21093) of size 39x18x1.5mm weighing 0.634 Kg/m, shutter interlock vertical frame (section 21094) of size 39x18x1.55 weighing 0.734 Kg/m, shutter bottom horizontal frame (Section No 20551) size 40x20x1.5mm weighing 0.484 Kg/m, with powder coating of min thickness 50 micron , sliding type with out sash bars, 4mm thickness colour glass, rubber packing, snap beading screws with stainless steel wire mesh. etc completet all as specified
Framed work such as grills, gratings, angles etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of static water tanks and similar work con- forming to Fe.290.Gde-E-165 including dismantling wrough iron or mild steel work of any description complete all as specified
Virified Ceramic tiles 10 mm thick,dark shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer ,15 mm thick in Cement Mortar 1:6 complete all as specified and as directed.
Note :- (i) Vitrified tiles are classified under group B1a of the international Standard for ceramic tiles ISO: 13006. Tiles shall be hard, dense, impervious and frost resistant. Water absorption of tiles shall be less than 0.5% and flexural strength (Modulus of Rupture) shall be more than 35 N/Sqmm. (ii) The manufacturer's test certificate and individual test certificate of Tiles must be submitted for approval by the concerned authority prior to installation.
Preparing newly plastered surfaces and applying two coats of weather proof coat paint (APEX) over a coat of primer on external surfaces complete as per manufacturers instructions all as specified and directed.
Mild steel plain black sheet 1.25mm thick in wall cladding steel gates and similar work.all as specified and directed.
Rendering 15 mm thick on fair face of stone surface in cement mortar 1:6 and 5mm thick floating coat in cement mortar (1:4) mixed with water proofing compound, finished even and smooth with out using extra cement, including taking down existing plastering complete all as specified and as directed. Note: Supply only water proofing compound measured and paid separately.
Preparing newly plastered surfaces of walls and application of putty to cover the complete surfaces any number of coats, sand papering to obtain smooth surface, priming the surfaces and applying two coats of distemper oil emulsion including priming plastered and other surfaces with alkali resistant priming paint on surfaces of walls complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc., complete all as specified and directed.
Demolition of un reinforced concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level)
Demolition of reinforced concrete of any description and in any position not otherwise specially provided for (reinforcement cut as required to facilitate demolition)
Taking down Chowkats or frames with shutters(Without taking off shutters from the frames) not exceeding 1.5 Sq. M each complete all as specified and directed.
Taking down Chowkats or frames with shutters(Without taking off shutters from the frames) exceeding 1.5 Sq. M each but n exc 4 sq.m each complete all as specified and directed.
Dismantling wall and ceiling boards/ cubicals/partition (fibre, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness, including cover fillets.
Virified Ceramic tiles 10 mm thick, dark shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in vertical surfaces etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer ,10 mm thick in Cement Mortar 1:4 complete all as specified and as directed.
Note :- (i) Vitrified tiles are classified under group B1a of the international Standard for ceramic tiles ISO: 13006. Tiles shall be hard, dense, impervious and frost resistant. Water absorption of tiles shall be less than 0.5% and flexural strength (Modulus of Rupture) shall be more than 35 N/Sqmm. (ii) The manufacturer's test certificate and individual test certificate of Tiles must be submitted for approval by the concerned authority prior to installation.
Virified Ceramic tiles 10 mm thick, light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in vertical surfaces etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer ,10 mm thick in Cement Mortar 1:4 complete all as specified and as directed.
Note :- (i) Vitrified tiles are classified under group B1a of the international Standard for ceramic tiles ISO: 13006. Tiles shall be hard, dense, impervious and frost resistant. Water absorption of tiles shall be less than 0.5% and flexural strength (Modulus of Rupture) shall be more than 35 N/Sqmm. (ii) The manufacturer's test certificate and individual test certificate of Tiles must be submitted for approval by the concerned authority prior to installation.
12mm thick toughened glasss frameless partition, with option of swing and sliding doors with all necessary to patch fittings and bottom insert like corner connection and side connector and bottom insert to the floor about 15 to 30mm or done with aluminium profile 12mm depth complete all as specified and as directed by Engr-in-Charge . Make : Saint Gobin/ESG/Modi)
False ceiling using GI snap grid size 60x60cm with main runner 38x24,wall angle & cross tee 29x24mm wall angle 24x24mm suspended with 4mm dia GI Wire fixed with steel dash fasteners carrying max load upto 8.1 Kg/Sqcm with 4mm thick designer ceiling board (Lake & Hill) all as per Everest regular T-2430 or equivalent (Make-Ramco/Charminar/ Armstrong).
Black Granite slab 18 to 20 mm thick machine cut, pre-polished , bedded in cement mortar 1:4 and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite in steps, jambs, pillars, window-cills, cooking platforms and like including Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations completet all as specified. Note : In case for cooking platform , including cutting a hole in the granite slab for gas pipe etc to any shape and polishing of exposed edges in cooking platform complete all as required site (Overall size of the slab shall be measured) complete.
Prepration of new or previously untreated steel surface of any description over 10 cm width or girth, not otherwise describedand applying two coat of synthetic enamel paint over a coat of red oxide zinc chrome primer complete allas specified and directed
Note :- (a) All synthetic enamel paint, plastic emulsion paint shall be of 1st quality manufactured by the standard firms of make as specified.
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint, will be approved by the GE.
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)
(e ) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
(h) No hair marks from the brush or clogging of paint buddles shall be left on the work. Surface shall ordinarily not be painted until it has dried up completely. Trial patches of paint shall be laid at intervals to check if drying is satisfactory.
Plates (plain or chequered) confirming to Fe 410-W (Gde E-250 quality A) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment
Brick work with fly ash `B' bricks, straight or curved on plan exceeding 6 M mean radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed.
Steel work in tubular trusses/post including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade-240) including dismantling existing steel complete allas specified and directed by Engineer in charge
Waste fittings 32mm brass chromium plated for glazed ware sinks, basins etc with long screwed shanks and fly-nuts flange and bedded in red lead cement and other and fixed complete all as specified and directed.
PVC SWR pipes 110 mm dia double socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
Cast iron floor trap 75 mm wwith grating including jointing to waste pipe fixed in cement concre type B1 1:2:4 complete all as specified and directed.
PVC (SWR) gully trap 125/110 mm setting and jointing with solvent cement complete all as specified and directed.
Cast iron soil waste and vent pipes 75 mm in any length with or without ears with cement joints fixed to wall complete all as specified and directed.
Vitreous china wash down water closet pan (Pedastel pattern) of size 580mm, white (excluding fixing bolts flushing cistern and flush pipe) complete all as specified and directed.
Mild steel works as in hold fast ,holding down bolts ,Gusset plates and similar items conforming to Fe-290,Gde 165 complete all as specified and directed.
Aluminium Composite panel cladding for wall clading and Mild steel column post casing, Wall cladding with 4mm thick aluminium composite panel (colour as approved by GE) fixed with aluminium frame using extruded aluminium section of size 50mm x 25mm x 2mm thick fixed with cleats,fasteners etc , gap will be sealed with silicon sealant appropriate grade complete all as specified and as directed
Note :- a) Providing and fixing Aluminium Composite panel cladding including framing as per the elevation, section and the plan fabricated out of heavy duty Aluminium extruded profiles conforming to alloy 643900 WP with chemical composition and mechanical properties as per IS-733 and as per specifications.
b) The contractor must design the cladding as per the prevalent site conditions and building elevations profiles. No extra claims shall be entertained at any stage for aluminium profile/ wall thickness and size dimensions. The Contractor must quote rates accordingly.
c) The anchoring / bracing of the wall cladding to the RCC beams/ columns shall be done with non-corrosive galvanized brackets of approved design, (Galvanizing to be done conforming to IS 4759-1996 up to 610 gms. Per Sq. M. (80- 90 micron thickness).
d) The framework shall be aligned for the entire height of each Mullion and of the entire width of each Transform by laser beam equipment to ensure 100 percent „X‟ axis and „Y‟ axis alignment.
e) The system should also provide for pressure equalization. The details for pressure equalization to be submitted by the contractor and got approved by the Engineer-in-Charge.
f) EPDM Gaskets of suitable profiles (to accommodate shall be provided including the labour element for fixing in appropriate locations is to be included in the rate).
g) The Periphery of the framework shall be sealed both from inside and outside with silicon weather sealant to make the cladding watertight.
h) Cost of Aluminium composite panel consisting of a core of polyethylene sandwiched between two aluminium skins of 0.5mm thickness with a mild edge. 4 mm total thickness with surface finish of PVDF coating as approved by the Engineer-in-Charge, as shown in the elevation, plan and cross section drawings along with labour element for cutting stacking, carrying to heights and fixing to appropriate locations is included in the rates.
j) All the vertical and horizontal section grooves are to be sealed non staining silicon sealant of make as specified in the list of approved make to make the entire system synchronies with the basic structural glazing/curtain wall structure and also make the system air tight and watertight. The fixing details should be got approved by the Engineer- in-charge. The peel off foil should be removed at the time of handing over as may be required by the Engineer-in-charge.
i) ACP shall be as approved with high fiber filled sandwiched panel 4mm install on Aluminium framing and Galvanised brackets. Aluminium cladding panel to be PVDF fluorocarbon coated factory applied colours. Reverse side to be in mill finish. All the joints shall be sealed with silicon sealant of approved make. The colour of sealant to be decided by Engineer-in-Charge.
ii) A sample of panels and installation methods to be submitted to the Engineer in-Charge for approval.
Virified Ceramic tiles 10 mm thick, light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer ,15 mm thick in Cement Mortar 1:6 complete all as specified and as directed.
Note :- (i) Vitrified tiles are classified under group B1a of the international Standard for ceramic tiles ISO: 13006. Tiles shall be hard, dense, impervious and frost resistant. Water absorption of tiles shall be less than 0.5% and flexural strength (Modulus of Rupture) shall be more than 35 N/Sqmm. (ii) The manufacturer's test certificate and individual test certificate of Tiles must be submitted for approval by the concerned authority prior to installation.
25 mm outer dia of pipes 3-layer PP-R (Polypropylene random copolymer) pipes concealed pipes SDR 7.4 (PN-16 @ 20°C) UV stablised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings, including taking down existing pipe of any description complete to walls, ceilings or in floors etc. all as specified and directed. Make : SFMC, Reliance Industries, KPT
Note :- (a) The unit rate shall be include the cost of short lengths, with all pipe fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc and fixing accssories such as pipe hooks, screws clamps etc
(b) Wall thickness of pipes shall be all as per IS : 15801
Galvanized steel water tubing medium grade of 32 mm bore with & including all fittings complete, laid in trenches, complete all as specified and directed. Note :- Excavation & earthwork shall be measured & paid for separately under relevant items of this Schedule.
Rotational moulded polyethylene water storage tanks 1000 Ltr (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I and all as directed
Fancy type chromium plated 25 mm bore Stop valves, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed.
Fancy type chromium plated 15 mm bore Stop valves, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed.
15mm bore chromium plated bib taps, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
Plain cement concrete (1:4:8) type D1 (20 mm graded stone aggregate), 100mm thick, as in hard standing , top surface of concrete finished even and smooth with out using extra cement, including expansion joint 10mm thick filled with mastic filling comprising of 01 part of heated blown beitumen and 3 parts of sand incuding dismaintling of exsting concrete all as specified and directed.
Galvanized steel water tubing medium grade of 25 mm bore with & including all fittings complete, laid in trenches, complete all as specified and directed. Note :- Excavation & earthwork shall be measured & paid for separately under relevant items of this Schedule.
Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') complete all as specified and directed.
Granite (of any type) tiles 20mm thick machine cut,bedded and jointed with grey cement slurry and pointed with white cement incl 15mm thick screed bed in CM 1:4 complete all as specified and directed.
Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
Anodised aluminium window and ventilator shutters with powder coated fixed type without sash bars , aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified
Providing and fixing 10 mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface over GI frame work pf seamless ceiling comprisiong of GI perimeter channel 0.55 mm thick wotj two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section(not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.50 mm fixed to the intermediate channel with connection clips across the intermediate channel 457 mm centre to centre including hangers of 6 mm dia GI (upto 1200 length )adjusting level fixed to roof slab by means of ceiling cleat made out of GI flat 40x3 mm size 60 mm long complete all as spd and directed.
Sliding Sheet glass 5.5 mm thick ordinary quality and glazing with oil putty in square exc 0.5 sqm in each pane inclding solar control film 25 micron reflective type sicked to glass panes as per instructions of manufactures complete all as specified and directed.
18mm thick both side prelaminated particle interior grade , prelaminated one side with decorative choice lamination & other side balancing white lamination , fixed with screwes to aluminium frame work complete all as directed
Taking down shutters of any description n.exc 1 Sq.M work complete all as specified and directed.
Excavating in post holes (or similar holes) each not exceeding 0.5cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance not exceeding 50m and making good surface as in hard / dense soil complete all as specified and as directed.
Plain cement concrete type B2, 1:2:4 using mm graded stone aggregate foundation, filling and mass concrete complete all as specified and as directed.
75 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed.
50 mm long medium weight cold rolled mild steel Butt hinges complete all as specified and directed.
Taking down carefully copper/Alu point wiring (light, fan. socket or power) complete including fixtures and fitings such as switches, ceiling roses, padents, regulators, sockets , light fitting etc and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separetely) and making good distrubed surfaces of walls, floors etc.complete all as specified and directed.
Point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade ISI 694 marked cable for phase & neutral drawn through concealed PVC Conduit, heavy duty 19/20 mm dia, ISI marked including cutting of chases for laying conduit making good the surfaces as per existing surfaces or as directed with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed. Make of Conduit : Avon Plast/ Supreme/ Diplast Make of Wire : Plaza/ Polycab/ Havells Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b) Connection of wire with switch, socket shall be through copper thumble (lugs) only.
(a) One light point/fan/bell point controlled by one switch
(b) All as per item No. 109 here in before but for One 3 pin socket out 5 amp on the same board
(c). All as per item No. 109 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 109 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Modular switch 6 Amps 240 volts single pole one way, 1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Modular switch 16 Amps 240 volts single pole one way, 1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Modular socket outlet multipurpose 2/3 pin 6 amps, 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Mdular socket outlet multipurpose 2/3 pin 6/16 amps, 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
White cover plate with frame, 3 Module.
White cover plate with frame, 6 Module.
White cover plate with frame, 8 Module.
Metal flush box 3 module.
Metal flush box 6 module.
Metal flush box 8 module.
Electronic modular fan regulator 230 volts, step type socket type, hum free 120 watt 2 Module. Make :- Havells, Erabtree, Legrand
Ceiling rose, surface type Bakelite 65x55mm 3 terminal
4 feet surface mounted battern type luminaire with a power consumption not more than 16 W, luminaire lumen output of 2000 lumens, luminaire efficacy > 120 lm/W with an operanting voltage range from 140V-270V. The luminaire shall have a white CRCA housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than. The luminaire shall have a CCT of 6500 K, CRI>80, power factor>0.95, SDCM<5, THD<10% and 50,000 burning hours as per L70B50 criteria. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature. The luminaire shall be EMI/ EMC complaint and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability (The driver can be replaced at site level). The luminaire shall not weight more than 7 Kg and the luminaire and driver shall be BIS approved with "R" number mentioned. Make : Philips Cat No BN308 LED20S 6500 L120 PSU WH or equivalent in Bajaj or Wipro.
Note :- (a) LED Chip make shall be Nichia, Osram, Cree, Lumilid. (b) The contractor shall submit to Engineer-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED Chip used and luminaise respectively while getting sample and material approved. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract. (d) The contractor shall submit warranty certificate from manufacturer for minimum 02 years.
36 W LED recessed 2x2 luminaire with classic design & glare free soft illumination. Housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens. CRI >80, Color temperature5700±300K, THD <10% and PF >0.95, IP20, IK02.Life class of 50,000 hrs @ L70, Operating Temperature: -10 TO +45 DEG.C; Input Supply Voltage Range:150-277 V, Frequency :50-60 HZ. Driver Safety requirement stds: IS 15885-2-13, Test Report to be submitted; Test Certificate to be submitted; Certification : LM 79 for luminaire & LM 80 for LED source. Make : Bajaj Cat Part No Skylux - BZRSQL 30W GZi WH / Philips cat No RC 355 BLED 33-6500 PSU OD WH or equivalent in Wipro including taking down existing one
Note :- (a) The contractor shall submit to Engineer-in-Charge photo Biological safety Norms as per IS 16108. (b) LED Chip make shall be Nichia, Osram, Cree, Lumilid. (c) The contractor shall submit to Engineer-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED Chip used and luminaise respectively while getting sample and material approved. (d) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract. (e) The contractor shall submit warranty certificate from manufacturer for minimum 02 years.
High power LED street light fittings energy saving luminaire with lens , capacity 20 watt with system efficacy (lm/w) not less than 90 lumens per watt, total system lumen not less than 2000 lumens, PF not less than 0.95, CRI not less than 70, colour temp. 5000K TO 6500 K, surge protection not less than 5 KV, high pressure die cast aluminium alloy LM6 housing IP-65/66 class 1 protection, toughened glass cover, driver efficiency > 85% with constant output of current and voltage against input voltage variation 120 to 270 volt at 50 Hz ( + 5%), THD< 10% complete all as specified.. Make : Philips Cat No BRP022 LED 20 CW MR S1 PSU GR or equivalent in Bajaj/Wipro.
Note :- (a) The contractor shall submit to Engineer-in-Charge photo Biological safety Norms as per IS 16108. (b) LED Chip make shall be Nichia, Osram, Cree, Lumilid. (c) The contractor shall submit to Engineer-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED Chip used and luminaise respectively while getting sample and material approved. (d) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract. (e) The contractor shall submit warranty certificate from manufacturer for minimum 02 years.
Energy efficeint Ceiling fan 1200mm sweep, energy efficient ISI mark with 5 star rating 230 Volts AC 50 Hz, single phase including provision of fixing arrangement, nut and bolt and flexible 3 core of size 1.5 sqmm not less than 0.5 m long complete all as specified and as directed. Make : Havells cat Part No.ES-50 Premium 5 star or equivalent in Bajaj/Crompton Greaves.
Factory made powder coated distribution board TPN 4 way, double door including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and directed
Factory made powder coated distribution board TPN 4 way, double door including bus bar, Neutral bar, standard DIN rail, earth bar including taking down existing one complete all as specified and directed
Factory made powder coated distribution board SPN 8 way, double door including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and directed
Factory made powder coated distribution board SPN 8 way, double door including bus bar, Neutral bar, standard DIN rail, earth bar including taking down existing one complete all as specified and directed
Triple pole Neutral MCB 63 Amp , 415 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity including taking down existing one complete conforming to IS 8828 of 1996 all as specified (Make/Model : Legrand Cat Part No 408683 or equivalent. of Schnieder (Multi -9) Siemens/L&T (Hegar).
MCB SPN 32 Amp , 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity including taking down existing one complete conforming to IS 8828 of 1996 all as specified (Make/Model : Legrand Cat Part No 408617 or equivalent. of Schniede, Siemens/L&T.
Single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 including taking down existing one all as specified Make/Model : Legrand Cat No : 408587 to408595 or equivalent. of Schnieder, Siemens/L&T.
Sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC rigid conduit including cutting of chases for lying conduit making good the surfaces as per existing surfaces or as directed for concealed and all accessories fixed to wall/floors along with one run of 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing one complete all as specified and directed. Note: (a) 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor, PVC rigid conduit shall be measured as one length including taking down UNSV old wiring. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
XLPE insulated,screened ,PVC Bedded,galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 25 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc all as specified and directed. Make :- Havells/ Polycab/ KEI
Supply and spread Riddling Sand for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming. Note :- The rate is deemed to be included, in case sufficient sand not obtained from excavation, the required additional qty obtain from out side land as directed by the Engineer-in-Charge.
Fly ash bricks sub class B brick for cable protection size 23x11.5 x7.5cm. complete all as specified and directed.
AC single phase static energy meter of accuracy class 1.0, 240 V, 50 Hz with Backlit LCD display of rating 5 - 30 A, (measures and displays KWH, V, Current I, KW, pf last month history of KWH, MD in KW) with special features like TOD, temper logging, optical communication port display in absence of power with transparent hinge type box complete all as specified and directed. Make :- BENTEC/ L&T/ ABB
Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 32x6mm by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion complete all as per specified and as directed.
Note :- (a) All Joints should be joined by Exothermic Welding or Brazing. (b) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned. (c) Earth resistance tester will be provided by the contractor. It should be caliberated from authorised Company/ Lab. (d) After testing if desired earth resistance of less than 5 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained.
Exhaust fan 250 mm sweep 230 volt square type with louvers of PVC body including necessary cutting, making holes on stone/brick walls, fixing arrangement with wooden frame of 20 mm thickness including necessary nut, bolts / screws all specified and directed. Make-Havells Cat No Ventil DX-White or equivalent in bajaj, Crompton Greaves etc complete all as specified and directed.
Glazed ceramic coloured tiles 450 x 300 mm x 7/8 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles on vertical surface such as dado including 10mm thick 1:3 backing coat including taking down existing tile and removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. Note : The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation.
Joint free Non Skid Ceramic Tiles 7 to 8 mm thick [Square or Rectangular] Coloured, area of each tile exceeding 0.06 Sq.m and not exceeding 0.18 Sq.m, as in Floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer,15 mm thick in Cement Mortar 1:4 including taking down existing tile and removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. Note : The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation.
Cement Concrete 1:5:10, type E-1 (20 mm graded aggregate) in foundations, filling and mass concrete complete all as specified and directed.
Cement Concrete 50mm thick 1:4:8, type D-1 (20 mm graded aggregate) as in sub base complete all as specified and directed.
Ball Brass valve 32 mm high pressure with polythene float and fly nut complete screwed for iron pipe etc. complete all as specified and directed.
Cutting openings, through brick walls for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc. to store and rubbish not exc. 50m complete all as specified and directed.
Forming Jambs etc to opening(to foregoing item),including cutting toothing and properly bonding into old work,also facing,jointing and pointing to match existing work complete in cement mortor 1:4 all as specified and directed.
Making good under cills or over arches,lintel and bressummers, including all pinning when necessary in cement Mortor 1:4 all as specified and directed.
5.5 mm thick coloured tinted float glass and glazing with beads complete all as specified and as directed
25 mm thick Cement concrete type B0 1:2:4 (12.5 mm graded aggregate) as in flooring complete all as specified and directed.
Vitreous china wash basin white flat back size 630 x 450 mm excluding taps waste chain and pug and procelain stoper but including brackets complete all as specified and directed.
Pillar tap 15mm cast copper alloy with capstain heads chrom,ium plated screwed down high ressure with or without lettered Hot or cold with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and directed.
PVC valveless syphonic action type flushing cistern (10 litres) low level white with inlet ball valve float and handle including brackets complete all as specified and directed.
Preparation of old plastered surfaces of any desciription and applying two coat of plastic emulsion all as spd and directed
devan enterprises
M/S Sneha Enterprises
NAVEEN ENTERPRISES
Sreyas Enterprises
Neptune Engineers and Builders
Radikan
A.GOVINDARAJ
T C KARUNANITHI
jk construction
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .