Tender Value
₹57 L
EMD Value
₹1.3 L
Closing Date
31 Aug 2019, 3:00 pmClosed
DHO ZP Nandurbar
DHO ZP Nandurbar
Supply of Medical Equipments for Zilla Paishad Nandurbar
2019_NANDU_479605_1
ETN-5/2019-20
Open Tender
Medical Equipments/Waste
Item Rate
45 days
Nandurbar
Please refer Tender Document
2 documents required · 2 mandatory
₹13,000
Yes
Online Payment
₹1.3 L
Yes
Nandurbar
18 Jun 2020
21 Aug 2019
3 Sept 2019
21 Aug 2019
31 Aug 2019
21 Aug 2019
26 Aug 2019
Amount
Portable Autoclave with 2 drum 1.Horizontal Cylindrical High Pressure Steam manufactured as per BIS specification No. IS: 3829 (Part-1) – 1978, with the latest amendments and bearing BIS Mark IS: 3829(Part-1). 2.SHAPR &DIMENSION: CYLINDRICAL 400 MM X 600 MM approx. 3.MODE OF EATING:Electrically heated be immersion heaters of 6 kw electric load wired for operation on 1phase 3-wire 230 volts 50 Hz A.C.Supply. 4.WORKING PRESSURE:20Lbs/Sq.Inch. 1.26kgf/cm2. 5.Operatingpressure: 1.05+015Kgfcm2.Approx.(20psi). 6.Operating Temperature: About 121◦c. 7.Hydrostatic Test: The shell should be subject to hydrostatic test to twice the working pressure. 8.Meterial of Construction: a) chamber & Back Plate:SS Sheet of grade (04Cr18Ni10)304 non-magnetic 10SWG. b) Jacket & Boiler:SS Sheet of grade (04Cr18Ni10)304 non-magnetic 10SWG. c) End Ring :SS 304L non-magnetic. d) Piping & Connections:Made of Stainless steel having mirror finish. e) Dished Door: Stainless Steel 304 quality 14mm thick. 9.Dished Door: Fitted with one Dished Door SS-304 and brass Hinges,with SS-304 radial arms to manipulate smoothly by well insulated handles, and shall have gumetal Door Locking assembly & automatic pressure locking device to provide complete safety to the operating personnel against any explosive opening of the door under high pressure. Provision is made to tighten the dished door while in locked position. A moulded steam and heat resisting silicone joint less gasket shall be fitted to the door. 10.OPERATING VALVE: To control the cycle of sterilization as per BIS standards. 11. SAFETY VALVE:As a pressure switch for controlling pressure is provided on the jacket, spring- loaded safety valve should be provided to the jacket as a safe guard against excess pressure in the jacket. 12.EJECTOR:- A powerful ejector system to create partial vacuum (help in quick drying). 13.DRYING SYSTEM:-Allows filtered air into the chamber during drying cycles. 14.VACCUM BREAKER:Prevents formation of accidental vacuum in jacket due to steam condensation. 15. PLUG SCREEN : Fitted in Chamber, prevents Chamber from clogging with lint and sediment. 16.DIAL THERMOMETER: Indicates the working temperature in the Chamber accurately. 17. PRESSURE GUAGE: Indicates the actual pressure of steam in the jacket. 18. COMPOUND GUAGE:Indicates the vacuum and pressure in the chamber. 19. A POCKET( FOR THERMOGRAPH):Provision to fit the bulb of temperature recorder. 20. STEAM (Float) TRAP AND CHECK VALVE: Fitted into the discharge line for automatic removal of residual air and condensate to give optimum sterilization temperature. 21. BOILER (STEAM GENERATOR): Cylindrical type and fitted to underside of jacket. It should be fitted with: 22.Immersion type heating elements (Total 6kwLoad). 23.A Low Water protection Float Level Switch for heaters to cut off electricity supply to heaters through a float switch and Contactor if the water level runs below heater level. 24. Water Level gauge glass tube top indicate the level of water in boiler which is capable of self- locking in case of it breakage. 25. Water inlet valve with Non return Valve and drain valve etc. 26. Pressure control switche to control and keep pressure constant in the Jacket. 27. Heater mounting plate (10mm thick) and nut bolts are made of Stainless Steel 304. 28. Pressure gauge provided to the boiler for indicating pressure in the boiler. 29. In addition,equipped with magnetic air break contactor, Toggle switch & RED & GREEN indicators. 30. It should be CE or US FDA Approved. 31. TRAY (STAINLESS STEEL): Provided in the Chamber of suitable size. 32. Whole unit should be mounted on a tubular pipe stand with leveling flanges and duly painted with best heat resisting epoxy paint.
Radient Warmer - 1. It should be microcontroller based radiant warmer with manual and servo options. It should have facility to display skin set, skin observed temperature in degree C and heat power separately. Should have user friendly touch panel control. It should have ceramic or quartz infrared or calrod heater. It should have audiovisual alarm facility for overheating beyond set temperature range. It should have alarm facility for patient temperature less than or greater than the required temperature i-e above or below the set range. Machine should sense the skin probe failure and cut off the heater. Warmer head should be rotatable in different direction, so as to allow taking X-ray. It should have alarm for probe failure, power failure, system failure and heater failure. Observation light of 90 to 100 foot candles or 1000 Lux (color temoerature range 3700k to 5100k) Should be provided for inspection 10.. Battery backup for power failure indication during power fail 11. The desired temperature range from 25 to 40 degree C and settable temperature can be from 32 to 38 degree C. 12 .The resolution should be 0.1 degree C and accuracy should be0.2°C. 13. Should have a facility to lock the keyboard to avoid unwanted user modification of the set parameters. 14. The height of the warmer should be adjustable for different types of bed. 15. It should have separate bassinet trolley; bed should be tilt able and have provision for X-Ray cassette holder, Mattress foam density. should be minimum 25Kg/cm³, transparent collapsible side walls easily detachable for cleaning. Mattress size should be minimum 20” × 30”. Should have a feather touch operation with large digital display and 16. comprehensive alarms. Control Panel should be liquid proof and allow easy and hygienic disinfection.Manual mode can adjust Heater output 10-100% with 10% 17. increment, an auditory and visual alarm shall be given at least every 15 min.In manual mode, heater cut off / Switch off , if the maximum 18. irradiance at any point of the mattress area exceeds a total irradiance level of 10 mW/cm² (between 10 to 30 minutes). 19.Bed should be about 80-100 cms from the floor and 80-90 cms from the heat source. 20.Should have lockable castor wheels. 21.Green indicator light shall be provided to indicate that warmer is ready for normal use. 22.Markings on the bassinet and X-Ray cassette holder are mandatory to enable proper positioning of the baby while doing the X-Ray.The size of the drop down sides should be such that it is 5” above 23. the mattress surface and should be at least 6mm thick, clear and transparent. 24.If there is more than 60% heater output for 10 minutes it should cutoff with alarm. 25.For the purpose of cable management there should be at least two number of tubing ports (edges covered by silicon rings) on the side walls. The height of the side walls should be minimum 110mm over the mattress. 26.X-Ray cassette tray should be at least 750×350mm and should adopt up to 20mm thick X-Ray cassette. 27.The baby bed should be crevice free for ease of cleaning, infection control. 28.The mattress used should be of biocompatible material. 29.Thermistor based skin temperature probe should be small in size not more than 10mm diameter and 3-4mm thick to fix the probe firmly on the infant. Baby contact material should be biocompatible as per ISO 10993 standard requirement. It should be insulated on one side and have well conducting non-rusting, non-reacting metallic surfaceon the other side. Probe wire should be pliable, thin and soft. The attachment site of the probe with the wire should also be pliable andnon-stiff. 30.Settings: 1) Should have Manual mode and Baby (Servo) mode settings. 2) Mode of operation should be clearly displayed. 3) In servo mode baby set temperature should be 32 to 38 deg C. 31.User’sInterface:Manual and servo controlled temperature regulation. 32.Software and/or standard of communication: LED Display and inbuilt software; Interruption and resolution of the power supply does not change the preset values. 33.Others: 1) Device shall not overbalance when placed in any transport position of normal use on a 10° inclined plane from the horizontal plane.2) Transformers of device shall be protected against overheating in the event of short circuit or overload of any output winding.3) Patient leakage current should be less than 100µA in normal condition. 4) Temperature on the baby mattress should not exceed 43 deg C when the warmer is operating under steady temperature condition. 5) Temperature of HEATER GUARDS should not exceed 85°C in normal use. 6) The Temperature differences on the mattress shall not exceed 2°C. Physical Characteristics. 34.Dimensions (Metric) : Specifications upto :2000mm (Height) ×900mm (Width) × 1100mm (Length). 35.Weight (lbs., kg) : maximum specs : 150Kg. 36.Configuration: At least 60 degree angle adjustment must be possible. in the heat source and it should provide shielding to the infant in case of breakage of tubes/ bulbs, All surfaces to be made of corrosion resistant material. 37.Noise (in dBA) :Auditory alarm shall have a sound level of at least 65 dBA at a distance of 3 m from the front of the infant radiant warmer, and the sound level of the alarm shall not exceed 80dBAon the mattress 38.Heat Dissipation : Shuld maintain up to36.5 deg.Temperature and the heat disbursed through a exhaust fan,so that effect of UV light is not disturbed. 39.Mobilty,portability: Yes,on castors (2 of the castors should have breaks;castor size can be at least 4 inch ) 40.Power Requirements : 220 to 240v,50 Hz 41.Battery Operated: Power failure indication during power fail. 42.Tp;erance ( to variations, shutdowns ):+ 10% of input. 43.Protection :OVP,earth leakage protection. 44.Power consumption : maximum 800 Waitt. 45.Other energy supplies: Solar Heating-desirable;not essential. ACCESSORIES SPARE PARTS ,CONSUMABLES. 46.Accessories ( mandatory,standard,optional ): Should have standard IV pole ( sturdy;on rusting; medical grade stainless steel ; sdjustable to a max height of 6 feet from the ground level ),monitor tray (12 x10 inches, 270 deg swivel;fixed at level of warmer display and storage trays. 47.Spare parts (main ones ): skin temperature pribes,Quantity? 48.Consumables / reagents ( open ,closed system ): Thermal reflector to fix the sking probe on baby. ENVIRONMENTAL AND DEPARTMENTAL CONSIDERATONS 49.Atmosphere / Ambiance (air conditioning, humidity, dust .) Operating condition: –Capable of operating continuously in ambient temperature of 0 to50 deg C and relative humidity of 15 to 90% in ideal circumstances.– an ambient air velocity is less than 0.3 m/s. 50.User's care, Cleaning,Disinfection & Sterility issues :Complete unit to be easily washable and serializable using both alcohol and chlorine agents. STANDARDS AND SAFETY. Performance and safety standards (specific to the device type); Certificates (pre-market, sanitary, ..); Local and/or international : Should be FDA / CE (from Notified Body) of class IIb approved product. Shall meet IEC-60601-1-2:2007 Medical electrical equipment -- Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic compatibility - Requirements and tests (Or Equivalent BIS). Shall meet IEC 60601-2-21: 2009 Medical Electrical Equipment – Part 2-21: Particular Requirement for the basic safety and essential performance of infant radiant warmers . should meet IEC 60601-1:2005 standard requirements.Baby contact material should be biocompatible as per ISO 10993 standard requirement.Manufacturer should be ISO 13485 certified 52.Training of staff (medical, paramedical, technicians) : user training manual required. WARRANTY AND MAINTENANCE. 53.Comprehensive warranty 2 years. 54.The spare list of all spares and accessories (including minor) required for maintenance and repairs in future after guarantee /warranty period should be attached. Documentation. 55.User or Technical or Maintenance manuals (In English) to be supplied.
Instrument Trolly SS - SS Instrument Trollev Overall size W-1350 mm (+50mm) D-750 mm ( + 25 mm) H-900 mm ( + 50 mm) Welded stainless steel tubular work. Vertical of approx 32 mm X 18 G tubes or 32 mm X32 mm 18 G rectangular, horizontal stays at top and bottom of 25 mm X 18 G tube or 25 mm X 25 mm X 18 G over with 10 mm diameter stainless steel railings shall be provided on all three sides. 125 mm diameter. Non – rusting swivel castors wheels tow with brakes tow without brakes.Trolley shall be fitted with S.S pushing handle
Delivery Table - 1. Labour And Delivery Table Overall size : L-1850 mm (+ 50 mm ) when extended W-850 mm ((+ 50 mm)800 mm (+ 25 mm) • Costruction – Table tubular Base should be made of minimum 31.75 mm dia.X 16 G.S.S. tubes with horizontal lengthwise support stay of mimimum 25 mm X 16 G SS tubes. • The frontal stay should join these lengthwise stay in such a way so as to facilate the obstetrician to stand or sit a close to the table • Top shall be made in three sections fabricated out of 18 G SS sheets. • Back rest section sizes 750 mm X 625 mm approx. shall be welded on 25 mm diameter S.S tube 16 G highest 16 G hinged, • Buffers : Four Nos. corner buffers of adequate diameter shall be fitted to the four corners to absorb shock. • Railing : detachable and/or collapsible 2/4 of langth railings made of minimum 19 mm diameter X 18 G SS tubes telescoping in 25.4 mm dia.X18 G MS ERW tubes housed in MS square tube frame work of 25.4 mm X 18 G tube. • Facililty shall be provided for flush I.V. rod at four lacations . provision shall have to hold mosquito curtain poles. • 100 mm thic PU foam 40 density suitable mattress.and must be coverd with the rexine which shall be conformed to type A grade 1 class A of IS 8698 of 1984 or latest.
Hospital Plane Bed without castors (Indcluding Mattress) - 1.Overall size (without Matterss) 2000 L (+50mm) W900 mm ( + 50 mm) H 600 mm ( + 25 mm ) 2.The Bed frame shall be made up of minimum .60mm X 30mm Rectangular CRCA minimum 16G tube 3.Fix panel shall be made form minimum 18G CRCA sheet double press bend on four sides and shall have at equal pitch. 4.Panel shall be supported with rectangular tube Stiffener duly welded. Detachable bows shall be made of minimum 31.75 mm OD X 18G ERW tube with both head bow and foot bow of Height of 800 mm +25mm. 5.Both head and the foot bows shall have one tubular horizontal support minimum 25 mm dia .X 18 G ERW tube and three vertical supports of minimum 16 mm dia .X 18 G ERW tubes. 6.Bows should be provided with PVC shoes with nylon reinforcement. The bows should be bolted to the frame on brackets welded to the bows in such a way that bolt or nut shall not appear on top surface of the bed frame Facility shall be provided for flush I.V Rod at four locations. 7.Provision shall have to hold Mosquito curtain poles. 8.A mattress suitable for the bed made of 25mm thick soft foam top layer and 75mm thick firm grade of density 70 to 79 g/dm3 , indentation hardness 9 to 11.9 as per IS 8391 of 1989 or latest bottom coir layer for the patient comfort and better pressure care. 9.And must covered with the Rexene which shall be conformed to Type A grade 1 Class A of IS 8698 of 1984
Foetal Doppler - Should be Compact, Pocket Type and Light Weight not more than 500 g. • Large LCD Display for Display of Fetal Heart Rate. • Back Light for Better Visibility • Display Signal Quality, Low Battery, etc., • High sensitivity Doppler probe of frequency 2.0 MHz • Ultra sound Intensity ‹10mw/cm2. • Auto Shut Off Facility to save Battery Power • Built-in Speaker with Output not less than 1.0W • Should work on Rechargeable Batteries with Minimum Battery Time of 300Minutes. • Battery Charger and Spare set of Batteries AA type to be supplied. . • Volume Control Facility and Audio Output for Ear Phone should be available. • Heart Rate Range should be from 50 to 240 bpm with accuracy of + /-2% • Should be Water Proof Body. • Should have Facility for FHR Data transfer to PC. • Doppler Probe should be Light Weight with Holder Facility when not in use. • Should be supplied with Carrying Case. • Should have FDA Certification for International Quality Standard.
VISHAL ENTERPRISE
RAJNEEL DISTRIBUTOR
Maxsurgicals
Chandak Medical Stores
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .