xen
BDA OFFICE BHARATPUR
Electrification work of Scheme No.13 Block A, Block C and partial Block B BDA bharatpur
2026_UITBR_527744_1
online nit 32(2025-2026)01 bharatpur Development Authorit
Open Tender
Electrical Works
bharatpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,500
Secretary, UIT
₹67.2 L
Yes
BDA office
6 Apr 2026
16 Jan 2026
18 Feb 2026
16 Jan 2026
17 Feb 2026
16 Jan 2026
21 Jan 2026
Electrical Work :- Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit suitable for 11 KV / 33 KV (Earthed) cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streight through joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. Cross linking shall be done out side factory with E- beam/ peroxide technology. Extrusion process shall be in house OEM within same vicinity. including testing etc. as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 11 KV End Termination Kit Outdoor type 3 core 120/150/185 Sq.mm
11 KV Straight Through Joint Kit 3 core 120/150/185 Sq.mm
33 KV End Termination Kit Outdoor type 3 core 240/300/400 Sq.mm
Providing & Laying XLPE insulated three core Armoured Aluminium cable for working voltage 11 K.V.(E) confirming IS :7098 P - 2 with H4- Grade electrolytic aluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 3 core 95.0 Sq.mm
3 core 185.0 Sq.mm
Supply & fixing and fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . ( M.S channel 100X50X6 ,M.S angle 75X75X6 , M.S. flat 50X6 mm )
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. 300.0 Sq. mm 1 core
Supplying and drawing overhead steel core Aluminium conductor (ACSR) ISI marked(IS 398 part II-1996) on existing cross arms through insulator with all necessary T&P required including binding and twisting etc. complete in all respect as required. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. ACSR Panther Aluminium 30/3 MM
100 sqmm of (6/4.72 mm+1/1.57 mm) (Dog)
50 Sqmm of (6+1) 3.35 mm (Insulated Rabbit) for LT
Supply and fixing Substation structure for mounting 11/0.4 Kv Transformer on Double pole as per DISCOM specification complete in all respect as required including nuts and bolts etc (excluding the cost of poles) made of MS channel of 4 nos 100 x 50 x 6mm and 4 nos 75 x 40 x 6mm and MS flat 50 x 6mm etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Supply and fixing of following LT Supporting accessories with nut bolt & Clamps made out as per standard Discom's specifications with two coats of Red oxide and two coats of Aluminium paint etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. LT cross arm 1200 mm long with clamp
Supply and erection of RS joist of 116 x 100 mm, 11 Meter long with the welded/ bolted top hamper 65 x 65 x 6mm (0.7 Mtr long) making necessary arrangement for fixing 11 kV 'V' cross arm, LT bracket and guard wire bracket, grouted in ground 1/6 th of its length and fixed with cement, coarse and grit in 1:3:6 ratio in 1/5th of its length (40cm dia) from the bottom including two coats of aluminium paint over the complete length of joist etc. as required. (Excavation of pit PCC and CC foundation as per Discom specs. to be Paid Extra) All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Supply and installation of spike of M.S. rod 20mm dia 3.0mtr. long for earthing of (tower/pole) drive into earth by mechanical means sturcture connection the spike with cross arm top hamper PCC pole, lattics tower to earth etc. complete as per technical specification of DISCOM.
SITC of 11kV 630 Amps 21KA for 3 Sec. SF6 insulated, outdoor duty (IP54) , Extensible / Non extensible type Ring main unit (RMU) manually operated in combination of VCB modules and Load Break switch consisting of Copper busbar in SF6 insulated 304 (Non-Ferrite Non-Magnetic Grade) stainless steel enclosure of thickness 2.5mm with manometer. The HV switchgear and control gear should be confirming to IEC-62271-100, IEC-62271-200-2003 & IEC-60694-1996. The RMU should be internal arc tested for 21KA for 1Second with IAC-AFL classification for gas tank. Vacum Interrupter of VCB should be RMU Manufacturer’s own make. Each feeder of RMU should have voltage presence indicator. . and compring of followings:- 1 no. microprocessor based Self powered numerical relay with over Current/ earth fault & short circuit protection with each VCB feeder. - 3 Nos. Protection CT shall be of Burden 2.5VA, ratio 50/1A, Class of Accuracy class 5P10 for O/C and E/F protection for each VCB.- 1 No. Manometer for each tank,- 1 nos. Fault Passage indicator,-Right angle boots for all the feeder Modules All the type test certificates as per IEC from Third party NABL / CPRI / ERDA accrediated lab to be submitted. (Cost of RCC Foundation / Steel Structure to be paid Extra) All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR. Extensible 3 way RMU with 1 no. VCB & 2 No. Load Break Switch
Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade direct in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) , with procedure as per following points:- (a) Make a river sand bed of height 125 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth
Add Extra in Item no.11.5 if Excavation done in Hard Rock / CC road / TAR Road and making Good the same
Add Extra for Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade direct in ground in the same trench in one tier horizontal formation including excavation of trench of size additional 20 cm in width, with procedure as per following points :- (a) Make a river sand bed of height 125 mm along the trench, (b) Lay another cable in middle of trench in such manner that spacing between another cable is 20 cm., (c) Provide river sand bed of height 125 mm on top of the cable. (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 /Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth
Add Extra in Item no. 11.7 if Excavation done in Hard Rock / CC road / TAR Road and making Good the same
Add Extra for Laying of one number XLPE power cable of 11/33 KV (Earthed) voltage grade direct in ground including excavation of trench of size 120 cm (Depth) x 35 cm(Width) , with procedure as per following points:- (a) Make a river sand bed of height 125 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 125 mm on top of the cable. (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth
Add Extra in Item no. 13.3 if Excavation done in Hard Rock / CC road / TAR Road and making Good the same
Add Extra in item no. 11.1 to 11.4 for Laying Charges for cable through Vermeer machine by making pit at regular interval and repairing the pit after laying of cable with PCC/ Bitumin as required.
Supplying and making end termination with heavy aluminium lugs ( Pin / ring type ) confirming to IS 8309 -1993 & IS 8337-1976 duly crimped with crimping tool, PVC tape etc of following size.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 16.0 Sq.mm
Supply and fixing of LT Distribution Kiosk confirming to IS:13947/1993/ IEC 60947 Pt.3 amended up-to-date and as per DISCOM specifications made of 2 mm thick powder coated CRCA sheet of 415 volts 3 phase 4 wire triple pole and neutral type, complete in all respect as required. Including Incoming Switch Disconnector Fuse unit, Aluminium Busbar with copper one piece U contacts base, brass studs and nuts, copper busbar for main and interconnection, MS Channel frame of 75 mm x 40 mm grouted with C.C. of M-10 grade to achieve the height of 1.5 feet above the road level suitable for required no. outgoing. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. 400 Amp. LT Distribution Kiosk for 250/315 KVA Transformer
100 Amp. Distribution Kiosk suitable for Underground cable of Size 500mm x 550 mm x 700 mm
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. 16.0 Sq. mm 4 core
150.0 Sq. mm 3.5 core
185.0 Sq. mm 3.5 core
6.0 Sq. mm 2 core
Supply and fixing of 1.6 mm thick MS 11 kV Danger plates as per IS :2551-1982 & specification of Discom on the existing poles complete in all respectas as required. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of Earth & Back filling with compaction is to be Paid Extra)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 160 mm size
Supply of Fabricated 33 KV of 'V' type cross arms as per Discom specifications made of MS channel 100x50 ISMC (9.5Kg. Per Mtr.) on the existing poles complete including all necessary nut and bolt etc with clamps including two coats of Red oxide and two coats of Aluminium paint etc. as Required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Supply and fixing of top hamper as per Discom specifications on the existing pole complete including nut bolts etc as required. Vertical type 33 kV. 0.75mtr. IS 75x75x6mm as per tech specs. Of DISCOM (Steel weight 6.5Kg. Approx. per top hamper). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Supply & Erection of M S lattice structure of height 12.8 mtr as per DISCOMs approved design & details in alignment, including painting of tower of approved make two coat of red oxide paint and one coat of aluminium paint before installation and one coat of Aluminium paint after erection work completed as per technical specifications & drawing of DISCOM. (Excavation of pit PCC and CC foundation as per Discom specs. to be Paid Extra). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. 16.0 Sq. mm 3 core
Supply and fixing of 33kV Disc insulator and Hot dipped galvanized Hardware confirming to IS:731:1971 with latest ammendment and as per latest Discom Specs. on existing bracket including all accessories etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . B & S type hardware 120KN
B & S disc insulator 120KN
Supply and fixing of 11kV Disc insulator and Hot dipped galvanized Hardware confirming to IS:731:1971 with latest ammendment and as per latest Discom Specs. on existing bracket including all accessories etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. B & S type hardware 45 KN
B & S disc insulator 45 KN
Supply and fixing of PG / T clamps on overhead lines/jumpers, made of aluminium alloy 4600 of IS 617-1994 (with latest amendment if any) with steel nut and bolts conforming to IS 1363-1992 & IS 1367/1979-80 (with latest amendments if any) all ferrous metal parts intended for outdoor use except those made of stainless steel shall be protected by hotdip galvanising in accordance with IS 2633-1986 complete in all respect as required. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. PG Clamp for Panther Conductor
T Clamp for Panther Conductor
The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) including testing from CTL of discom before charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor). All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 100 KVA
315 KVA with Off -LTC (+5% to - 10% @ 2.5%)
Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR High Power LED Flood Light Minimum lumen output 14800 lm
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. 3 x 2.5 sq.mm
Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 50mm x 6mm copper strip
Mesh earthing as per IS:3043 with Hot dipped galvanized earth strip of size 25 mm x 6 mm to form a mesh of size 1000 mm x 1000 mm in horizontal formation to create equal sections of 200 mm x 200 mm by means of welding and embodying 1 mtr. Below the ground level, refilling the pit by alternative layers of charcoal & salt up to 500 mm with 20 mm dia. GI 'B' class watering pipe, wire mesh funnel and and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
P & F of Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Providing & Making of Exothermic joint in Tee / Square / Straight through joint in Strip for permanently bonding of copper to copper or copper to GI including required exothermic jointing kit comprising of graphite mould, weld powder, tools etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annex ure "A" attached with this BSR .
Wiring of light point/ fan point/ exhaust fan point/ call bell pointas per PWD specification for electrical Works with ISI marked 1.5sq. mm nominal size FR PVC insulated unsheathed flexible copperconductor 1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FRPVC insulated unsheathed flexible copper earth conductor 1.1 kVgrade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) verginmaterial PVC conduit & it's all accessories( J.B. , Bends etc.) , roundtiles,18 SWG G.I. box with earth terminal, 6 A switch , 3 pin ceilingrose/ Lamp holder / 3 point Connector, 3.0 mm thick ISI markedphenolic laminated sheet (IS : 2036 - 1995), Al. alloy/ cadmiumplated iron screws 20 mm cup washers etc. all as per preapproved by Engineer in charge, making connections, testing etc.complete as required. For specification of copper Conductor,Phenolic Laminated sheet's & Electrical/ Wiring accessories referChapter E - 04, E - 05 & E - 07 . For additional technicalparameters of products/ work , refer Annexure "A" attached withthis BSR Short point (up to 3 mtr.)
Medium point (up to 6 mtr.)
Long point (up to 10 mtr..)
E010300 Wiring of 3/5 pin 6 amp. Light plug point as per PWD specificationfor electrical Works with ISI marked 1.5 sq. mm nominal size FRPVC insulated unsheathed flexible copper conductor 1.1 kV grade(IS:694) and 1.5 sq. mm nominal size FR PVC insulatedunsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI marked MMS ( IS:9537 P - III ) vergin material PVCconduit & it's all accessories( J.B. , Bends etc.) , round tiles,18 SWGG.I. box with earth terminal of required size, 6 A switch, 3/5 pin 6A socket, 3.0 mm thick ISI marked phenolic laminated sheet (IS :2036 - 1995), Al. alloy/ cadmium plated iron screws 20 mm cupwashers etc. all as per pre approved by Engineer in charge,making connections, testing etc. complete as required. Forspecification of copper Conductor, Phenolic Laminated sheet's &Electrical/ Wiring accessories refer On board
Short point (up to 3 mtr.)
S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III )vergin material PVC conduit as per PWD specification for electricalWorks along with its accessories (IS: 3419 ) as required in recessincluding cutting the wall, covering conduit and making good thesame as required. All relative and latest acceptance tests reportsby any NABL accredited lab for the conduit shall be submittedbefore execution & All as per pre approved by Engineer in charge.For additional technical parameters of products/ work , referAnnexure "A" attached with this BSR . 25 mm
Supplying and drawing FR PVC insulated & unsheathedflexible copper conductor as per PWD specification forelectrical Works with ISI marked (IS:694) and as per IS8130 : 2013 of 1.1 kV grade . Wire should be made from99.99% purity copper, class 5 stranding in acc. to IEC60228 for lower watt loss , oxygen free ( <10 ppm) forless chances of oxidization and higher silver content forgives better conductivity , insulation PVC type A ,flameretardant as per IS 10810-53, better amperage rating asper VDE 0298 part 4, , in existing surface or recessedPVC/ MS conduit/casing capping including all as per preapproved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL labsetup for all testing facilities for wires. For additionaltechnical parameters of products/ work , refer Annexure"A" attached with this BSR . 2 x 1.5 sq.mm
2 x 2.5 sq.mm
2 x 4.0 sq.mm
2 x 6.0 sq.mm
Supplying and Laying ISI marked P.V.C. insulatedsubmersible cable as per PWD specification for electricalWorks confirming to IS:694 and as per IS 8130 : 2013 of 1.1 kV grade .Wire should be made from 99.99% puritycopper, class 5 stranding in acc. to IEC 60228 for lowerwatt loss , oxygen free ( <10 ppm) for less chances ofoxidization and higher silver content for gives betterconductivity , insulation PVC type A ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298part 4 including making connection etc. as required. OEMMust have its own in house NABL lab setup for all testingfacilities for wires. All as per pre approved by Engineer incharge, making connections. For additional technicalparameters of products/ work , refer Annexure "A"attached with this BSR . 16.0 Sq.mm 3 core flat / Round
P & F 18 swg M.S. Recessed fan box, hexagonal/ roundof size 130 mm dia, depth 75mm, 12 mm dia rod fanhook with 100 mm length extended on each side . All asper pre approved by Engineer in charge. For additionaltechnical parameters of products/ work , refer Annexure "A" attached with this BSR
Providing & Fixing of 240/415 V AC MCB with positiveisolation of breaking capacity not less than 10 KA (B/ Ctripping characteristic as per type of load and siterequirement) 4KV impulse withstand voltage, as per PWDspecification for electrical Works with ISI marked IS8828 (1996) / conforming to IEC 60898-1 2002, IEC 60947-2,low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC, minimum phase termination capacity of35sq.mm. , conductorline load reversibility, label holdingfacility , IP 20 contact protection and fitted with istingdistribution board/sheets, min. operation 20,000 upto 32 Arating and 10,000 upto 63 A, 5000 for 80 A rating includingmaking connections, testing etc. as required. . OEM shallhave submit NABL / CPRI / ERDA accrediated lab testreports before execution & All as per pre approved byEngineer in charge. For additional technical parameters ofproducts/ work , refer Annexure "A" attached with thisBSR . 6 A to 32 A rating single pole
6 A to 32 A rating double pole
Providing & Fixing of IK09 recessed/surface mountingheavy duty horizontal type sheet steel of 1.6 mm thickDistribution board as per PWD specification for electricalWorks ISI marked conforming to IS-13032 & IS-8623 /conforming to IEC 61439-3. Phosphatised/ powder painted complete with suitable rating insulated copper bus bar,shorting link , neutral link, earth link , connecting wire ofsuitable rating and din bar,masking sheet, including makinginternal DB terminations with copper lugs and withdetachable gland plate, including making connections, testing etc. as required.OEM shall have submit NABL / CPRI/ ERDA accrediated lab test reports before execution & Allas per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure"A" attached with this BSR . E060620 IP-43 Double door (Three phase) E060622 6 Way ( 18 O/G + 8 I/C )
Providing & Fixing of IK 09 rating recessed/surfacemounting heavy duty Vertical type sheet steel 1.6 mm thickDistribution board as per PWD specification for electrical Works ISI marked conforming to IS-13032 & IS-8623 /conforming to IEC 61439-3 with provision of incomersuitable for MCCB and SP / TP MCB as outgoing ,phosphatised ,powder painted complete with insulatedsuitable rating copper bus bar , neutral link, earth link and din bar, masking sheet, including making internal DBterminations with copper lugs and with detachable glandplate, testing etc. as required complete in all respect.OEMshall have submit NABL / CPRI / ERDA accrediated lab testreports before execution & All as per pre approved by Engineer in charge. For additional technical parameters ofproducts/ work , refer Annexure "A" attached with thisBSR . E061220 IP- 43 Double door with Provision of Incomer MCCB 200/250 A Rating
E071200 Providing and fixing of non modular power plug pointaccessories as per PWD specification for electrical Works with18 SWG G I box of size 175 x 100 x 60 mm with earthing terminal/connector on recessed/surface with suitable sizephenolic laminated sheet (IS : 2036 - 1995) cover includingcost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socketoutlet [ as per detailed in respective item in BSR], makingconnection , testing , etc. as required. All as per pre approvedby Engineer in charge. For additional technical parameters ofproducts/ work , refer Annexure "A" attached with this BSR .
Providing & Fixing of ISI marked (IS:1258) 6 amp batten/angle/lamp holder as per PWD specification for electrical Works,made out from industrial grade Polycarbonate or fire resistantABS material, brass terminal & captive screws includingmaking connection testing etc. as required. All as per preapproved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attachedwith this BSR .
Providing & Laying P.V.C. / XLPE insulated & P.V.C.sheathed Un-armoured / Armoured aluminium cableof 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVCpipe/ open duct/cable trench with filling of excavatedearth in trench , on existing cable trays or on surfaceetc. including making necessary connection, testingetc. as required of size and as per points (a), (b), (c), mentioned below:-(a) Material :- H4- Grade aluminium conductor ofpurity >99.6 % & as per IS:1554 P-I / IS :7098 P - I(b) conductor shall have electrolytic aluminiumconfirming to IS 8130, IS 3975-1999 for armouring ofcables in armoured cable items , IS 5831 for sheath, IS10810 (Part 0 to 64 ) for testing procedures .(c) OEM Must have ISO 9001 & 14001 certificationsfor quality assuarance & its own in house NABL labsetup for all testing facilities for cables . Appropriatetype test certificate / OEM test report shall besubmitted . All above as per pre approved byEngineer in charge. For additional technicalparameters of products/ work , refer Annexure "A"attached with this BSR. 25 sq.mm 3.5 core
Pipe Earthing as per PWD specification for electrical Worksas per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. ' B 'class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS :1387 with perforated holes of 12 mm dia ,including allaccessories like nut, bolts, reducer, nipple, wire meshedfunnel, and Heavy duty weather proof poly-propyleneearth pit chamber with lockable Jam free lid suitable forsafe working load 5000 Kg or more of size Top Dia. 225 to260 mm, Bottom Dia 300 to 350 mm. and Height 250 to300 mm. and embodying the pipe complete with alternatelayers salt and coke/ charcoal, testing of earth resistancefor value of 5 ohms or less as required & must record byengineer in charge during site visit and ensure to enter inmeasurment book. All as per pre approved by Engineer incharge. For additional technical parameters of products/work , refer Annexure "A" attached with this BSR .
Supply & Laying following size' B ' class , Medium class G.I.Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessorieslike bend, socket etc. for laying earth conductor/ strip /cable in ground/ surface/ recess as required. All as per preapproved by Engineer in charge. For additional technicalparameters of products/ work , refer Annexure "A"attached with this BSR .
Providing & Fixing of IP20 SMD Mid Power LED batten typeintegrated light fixture made from polycarbonate /extrudedaluminium powder coated housing with in built driver , Power Consumption of 18W/20W ,system lumen efficacy ≥ 120 lm/Wattoutput, internal surge protection of 2.5 KV with Short & Opencircuit protection ,THD < 10% ,p.f.≥0.95, CRI >80 , life time ofminimum 50000 Burning Hours with , 70% of intial Lumenmaintaned till life ends , CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard and trade mark certificate ( T.C.). Manufactures WordMark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testingfacilities for LED fixtures. (LM79/LM80) certificate / Report fromOEM shall be submitted. All as per pre approved by engineer incharge . foe additional technical parameters of product/ work,refer Annexure "A" attacheded with this BSR. 4' LED Tube shape fixture 18/20 W (Extruded Al Base) Each 303.0
Providing & Fixing of energy efficient / energy saving direct fit(Retrofit) composite self ballasted compact fluorscent lamp (CFL)with PF >0.85 in existing holder / fixture as required complete in allrespect. All as per pre approved by Engineer in charge. Foradditional technical parameters of products/ work , referAnnexure "A" attached with this BSR 18/20 Watt
Providing & Fixing of IP40 LED Surfce/ Recessed / suspendedmounting Mid power SMD type LED Light fixture made from CRCAsheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiencywith 2.5 KV internal/external surge protection BIS certified isolateddriver having efficiency > 85% , with Short & Open circuitprotection and in compliance to IEC standards (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % ,p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hourswith , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximumpower consumption should not more than the specified rating andFixture shall be of BIS standard and trade mark certificate ( T.C.).Manufactures Word Mark/ Name Engraved/ Embossing/ Screenprinting on housing. OEM must have its own in house NABL lab setup for all testingfacilities for LED fixtures. (LM79/LM80) certificate / Report fromOEM shall be submitted. All as per pre approved by engineer incharge . foe additional technical parameters of product/ work,refer Annexure "A" attacheded with this BSR.E170912 48W LED light fixture 2'x2' with acrylic / prismatic front cover.
E180500 Supply and erection of M.S. Galvanized Octagonal pole ( as per BSEN40-3-3:2003 /BSEN 10025/IS 2062 IS:875 Part-1 – 2015/ for MS platefor base flange )of following length and dimension as per table P-01with base plate on the cement concrete foundation of M-20 grade (1:1.5:3) as per IS 456/IS 2911. with the help of anchor bolts of grade6.8 (IS: 1367 P III ). The pole shall have a weatherproof flush door andlocking arrangements. complete in all respect. All as per pre approvedby Engineer in charge. For additional technical parameters ofproducts/ work , refer Annexure "A" attached with this BSR . E180510 Octagonal MS Poles made of S-355JO grade steel sheet , foldedlengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally inaccordance with IS 2629. (See Table P -01 for specs.) 8 Mtr
Providing & Fixing of IK07 IP-66 protected high power LED flood lightsystem with Pressure diecast aluminium housing LM6/ ADC12material , toughened glass diffuser with suitable lenses on LED toachieve various beam angles, 240 volt, 50Hz, of high power LED lamps . Integrated driver must be potted & has a unique BIS R number shallbe high efficiency having efficiency more than 85 % and in complianceto BIS certified and T.C. certificate. The System level Luminaire efficacy>=120 lm/ wt with High Power LEDs is to be used . LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC andAuto resetting Safety . Input Frequency 50Hz±3%, Power Factor >0.95,driver Efficiency >85% , THD(I) <10% , driver current <1000mAshown in LM79 report. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector Must be provided, SurgeProtection Min >=4KV internal and 10KV external, System life of 30000Burning hours with 70% of Initial Lumens maintained, color RenderingIndex >70 and CCT 5700K ±355K. Driver current <1000mA shown inLM79 report. Manufactures Word Mark/NameEngraved/Embossing/Screen printing on die cast housing to allowtraceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testingfacilities for LED fixtures. (LM79/LM80) Certificate/ report withliable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additionaltechnical parameters of products/ work , refer Annexure "A"attached with this BSR . E181209 High Power LED Flood Light 200W
Providing & Fixing of Street light bracket made out from following sizeof ' B ' class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004) with heavy duty pole clamp, Saddles suitable fastners etc. asrequired. All as per pre approved by Engineer in charge. Foradditional technical parameters of products/ work , refer Annexure"A" attached with this BSR . E181703 32 mm Dia.
LED street light on existing bracket/pole. Fixture made of powder coated single piecepressure die cast aluminum LM6/ ADC12 material with heatdissipation fins on housing with UV stabilized PC/Toughened Glasscover (UV stablzation report submitted for UV cover ) and secondarylens on each LED & should be SMD type . The System level Luminaireefficacy >=120 lm/ wt with High Power LEDs is to be used and potteddriver must be potted & has a unique BIS R number with InputVoltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor >0.95driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RHWorking Temp -5C to 45C . driver current <1000mA shown in LM79report. The luminaire shall be BIS certified and T.C. certified. LifeExpectancy Equal or more than 50000 burning hrs with Minimum70% lumen maintened ,color Rendering Index >70 and CCT 5700K+355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4Hrs. Manufactures Word Mark/Name Engraved/Embossing on diecast housing to allow traceability/authenticity. Fixture shall be AS PERIS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testingfacilities for LED fixtures. (LM79/LM80) Certificate/ report withliable warranty of product/accessories from OEM shall be submitted.All as per pre approved by Engineer in charge. For additionaltechnical parameters of products/ work , refer Annexure "A"attached with this BSR . LED Street Light fixture 210 Watt
Supply & Fixing of ISI marked (IS : 15683) Fire Extinguisher, Trolley mounted, CO2 (gas pressure) type capacity 22.5 Kg. with gun‐metal cap. And nozzle and complete in all respects including initial fill and wall suspension bracket.Capacity 22.5 Kg.
Supply & Fixing ISI marked (IS : 15683) Portable Fire Extinguisher, ABC type, finished externally with red enamel paint, complete in all respects including initial fill and wall suspension of 6 Kg capacity.
2 kg capacity.
33/11 KV 5 MVA Power transformer ( as per JVVNL Design and drawing )
36 KV Outdoor VCB ( as per JVVNL Design and drawing )
12 KV OUTDoor VCB KIOSKS ( as per JVVNL Design and drawing )
110 V Battery CHARGER 120 AH ( as per JVVNL Design and drawing )
33 KV 800 amp Isolator with Post insulator with EB ( AS per JVVNL Discom Design and drawing)
33 KV 800 amp Isolator with Post insulator without EB ( AS per JVVNL Discom Design and drawing)
33/11 SUB STATION STRUCTURE (URBAN) BAY (33 & 11 KV)( as per JVVNL Design and drawing )
33 KV CURRENT TRANSFORMERS RATIO 240-120-60/5-5 A( as per JVVNL Design and drawing )
33 KV CURRENT TRANSFORMERS RATIO 400-200-100/5-5 A( as per JVVNL Design and drawing )
POTENTIAL TRANSFORMER 33 KV OIL FILLED( as per JVVNL Design and drawing )
33KV C&R PANNEL FOR TRAFO( as per JVVNL Design and drawing )
33KV C&R PANNEL FOR FDR( as per JVVNL Design and drawing )
11KV C&R PANNEL FOR FDR( as per JVVNL Design and drawing )
ACDB( as per JVVNL Design and drawing )
DCDB( as per JVVNL Design and drawing )
CT JUNCTION BOX( as per JVVNL Design and drawing )
PT JUNCTION BOX( as per JVVNL Design and drawing )
33KV LA( as per JVVNL Design and drawing )
11KV LA( as per JVVNL Design and drawing )
33KV DC LATTICE STRUCTURE 42 FT UN GL WITH 3 NOS CHANNEL V CROSS ARM( as per JVVNL Design and drawing )
Civil Work:- Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead as per Technical Specification Clause 301.5. with all lead .
Random rubble dry stone Kharanja under floor.
Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering – All work up to plinth level. 1:4:8 ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size).
Random Rubble stone masonry for foundation& plinth height above 30cm. thick walls in :CM 1:6.
Brick work with F.P.S. bricks of class designation 75 in super structure in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand)
Plaster on new surface on walls in cement sand mortar 1:4 including raking of joints etc. complete fine finish , 20 mm thick.
6 mm thick cement plaster to ceiling of mix 1:3 (1cement : 3-fine sand)
Providing and Fabricating reinforcement for RCC work including strainghtening, cutting bending placing in position and binding (including cost of binding wire) all complete up to floor three level. Thermo-Mechanically Treated bars (Conforming of relevent IS code).
Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc.
Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc.
Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix
Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. :- M20 Grade Nominal Mix (with graded stone aggregrate 20mm nominal size.).
Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering – All work up to plinth level. M20 Grade Nominal Mix (with graded stone aggregrate 20mm nominal size.).
Providing and fixing steel gate, grating and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide Add extra if square,rectangular hollow tubelar sections are used
Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and joined with 2 Nos. of 150mm long brackets of 15x15mm M.S. square tube, the vertical door profiles to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size complete as per manufacturers specification and direction of Engineer-in-Charge.
Providing and fixing to existing door frames 30mm thick factory made polyvinyl chloride (PVC) door shutter made of stiles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2mm +/- 0.2mm with inbuilt decorative moulding edging on one side. The stiles and rails mitred and joined and the corners by means of M.S.galvanized/plastic brackets of size 75x220 mm having wall thickness 1.0mmand stainless steel screws. The stiles of the shutter reinforced by inserting galvanized M.S.tube of size 25x20 mm and 1mm +/- 0.1mm wall thickness. The lock rail made up of ‘H’ section, a uPVC hollow section of size 100x30 mm and 2mm +/- 0.2mm wall thickness fixed to the shutter stiles by means of plastic/galvanized M.S.tube ‘U’ cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 610mm,having overall thickness of 20mm and 1mm+/- 0.1mm wall thickness.The panels filled vertically and tie bar at two places by inserting horizontally 6mm galvanized M.S.rod and fastened with nuts and washers.complete as per manufacturer’s specification and direction of Engineer-in-charge.(For W.C.and bathroom door shutter)
Providing and fixing M.S. sheet 1mm thick single leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint
Grading roof for water proofing treatment with water proffing compound Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :
Finishing with neat cement (punning)
Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance.
Painting with enamel paint of approved brand and manufacture to give and even shade. Two or more coats on new work.
Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete. New Plastered Surface (three or more coats)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:New work (two or more coats) over and including scrapping and priming coat with cement primer.
Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding: New work (Two or more coats applied @ 3.84 kg/10 sqm).
Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4).
Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar).
P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant.110 mm dia
P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall :Size 580 mm x 450 mm
P & F European type white glazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall and floor
P & F water closet Seat Covers with brass hinges complete :Solid PVC (IS 2548 marked) grade-I Black for EWC.
P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball (IS: 1703 mark) complete including cutting and making good the wall: PVC with PVC bend and superior internal fittings as per IS : 7231 .
P & F Grating of approved quality/make:Stainless Steel Sheet size 125mm dia. Heavy Quality of approved make
P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. C.P. Inlet connection 15mm.Brass (IS : 8931 marked)
P & F Stop Cock (IS :8931 Mark), superior quality & of approved make:Brass 400 gm. 15mm nominal bore.
P & F 15 mm. Dia Connection Pipe of approved quality/make :PVC pipe with C.P. Brass nuts upto length, 300mm
P & F Jet spray for water closet with C.P. Copper Tube flange of approved make.
P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make:C.P. Brass bib cock,15mm nominal bore.
Interlocking Concrete Block Pavement with M-30 Grade 0.30 Mtr x 0.30 Mtr x 0.15 Mtr Edge Blocks (measurments shall be made inner to inner side of edge blocks)Providing and laying of interlocking concrete block pavements having thickness 80mm as per drawing and technical specifications.
P & F 1st qualityVitrified Porcelain Polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigment etc complete.size 600 mm X 600 mm
Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.: Size 240 Cm. dia outside & 240 Cm. depth.
Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 grade C.C floor & RCC slab covering with M15 grade c.c. floor, 50 mm thick stone slab partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos stone foot rests of approved design ,two No. 450 mm dia each Ferro cement cover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:- Size 230 x110 x150 cm.(for 20 users) with 115 mm thick RCC (M-20) slab with Tor steel reinforcement 10mm ϕ @15 cm c/c bothways including shuttering complete in all respect.
Providing and fixing Polyethylene - Aluminium -Polyethylene (PE-AL-PE) Composite Pressure Pipes as per 15450 : 2004 U.V. stablised with carbon black having thermal stabillity for hot and cold water supply, capable to withstand temperature upto 80ºC including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers connectors etc.with clamps at 1.00 metre spacing.This include the cost of cutting chases and including testing of joints complete as per direction of Engineer In charge Concealed installation including cutting chases and making good the walls etc. complete.1620 (20mm OD) pipe
2025 (25mm OD) pipe
Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.Above 3601 Cm2 Slabs
Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand)For area of each slab from 2001 to 5000 Sq.Cm
P & F Kitchen & Lab. Sink of approved make with C.I. brackets duly painted, 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up-to floor level complete including cutting and making good the wall & floor :WVC Lab sink (IS:2556 mark) size 500 x 350 x 150 mm
P & F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 500 litres capacity.
Providing & laying Chequered terrazzo tiles of approved make 22mm thick with marble chips of size upto 6mm, in floors, jointed with neat cement slurry mixed wit pigment to match the shade of tiles including rubbing and polishing complete in all respect as per specification, on 28mm thick bed of C.M. 1:4 : Medium shade using approximately 50% white cement and 50% ordinary cement.
Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Short point (up to 3 mtr.)
Medium point (up to 6 mtr.)
Long point (up to 10 mtr.)
Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR On board
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. 2 x 1.5 sq.mm
2 x 4.0 sq.mm
Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification of Wiring accessories refer Chapter E - 07 related item & For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Double pole MCB(With B/C curve tripping Characteristics) 6 A to 32 A rating
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. 25.0 Sq. mm 3.5 core
Providing & Fixing of IP20, 2'x2' LED Surface/ Recessed mounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Surface Moutning Minimum lumen output 4200 lm
Providing and fixing aluminum work for doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285, fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and the directions of Engineer- in – charge .(Glazing and paneling to be paid for separately). For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer)
Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge.Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side.
Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basic item.)With float glass panes of 5.0 mm thickness ( weight not less than 13.50 kg/sqm)
Providing and fixing expanded grill made of aluminum as per design and drawing having members section of size 7.5mm x 6.0mm and opening of size 102mm x 99mm to aluminum window/vent with required screws, Y and H aluminium section (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge. Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer)
Providing and fixing of double leaf steel shutter for cupboard, the frame is made of pressed steel ISI section 80x25 mmx 1.25 mm thick with 1.00 mm MS sheet to spot welded including holdfasts of 15x3mm, MS oxidized fittings such as butt hinges, sliding doors bolts, handles, tower bolts and twin peg etc complete including applying priming coat of approved steel primer of red oxide zinc chromate and spray painting in approved shade with deco paint of approved quality complete as per direction of Engineer In Charge
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.93 MB
bid.pdf
Tender Documents • 12.25 MB
BOQ_941815.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid