Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.1 LAccepted-Finance | 1 | Accepted-Finance L-1 | |
| 2 | 2₹7.1 L+₹3,206 (0.45%)Accepted-Finance | 2 | Accepted-Finance L-2 | |
| 3 | 3₹7.3 L+₹18,680 (2.63%)Accepted-Finance | 3 | Accepted-Finance L-3 |
Tender Value
₹7.2 L
EMD Value
₹7,500
Closing Date
4 Oct 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE
ETC-II, UPPTCL, PAARESHAN BHAWAN, VIBHUTI KHAND, GOMTI NAGAR, LUCKNOW-226010
WORK
2021_UPTCL_622588_1
VERY SHORT TERM E-TENDER NO. ETC-II/L/36/2021-22
Open Tender
Electrical Works
Item Rate
365 days
400 KV S/S UNNAO
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
SE, ETC-II, UPPTCL, LUCKNOW
₹7,500
29 Oct 2021
21 Sept 2021
5 Oct 2021
21 Sept 2021
4 Oct 2021
21 Sept 2021
180 days
Amount
Maintenance of following as per schedule of maintenance & technical specification including its cleaning, tightening etc.
Maintenance of 400/220 KV 315 MVA ICT-I, II & III (Six Monthly) (2X3=06)
Maintenance of 220/132 KV 160 MVA ICT-I, II & III (Six monthly) (2X3=06)
Maintenance of 63 MVAR Bus Reactor, 50 MVAR Line Reactor of 400 KV Unnao-Bareilly Line –I & II and 400 KV Unnao-Agra line (Six monthly) (2X4=08)
Maintenance of 1.5 MVAR Neutral Grounding Reactor of 400 KV Unnao-Bareilly-I & II and 400 KV Unnao-Agra line of 50 MVAR line reactor (Six monthly) (2X3=06)
400 KV Bus Bar of quard moose conductor by tightening of all nut, bolts, clamps, jumpers including minor repairing work (Once in a year) including cleaning of disc insulator strings. (1X3=03)
220 KV Bus Bar of Twin Moose Conductor by tightening of all nut, bolts, clamps, jumpers including minor repairing work (Once in a year) (1X3=03)
132 KV Bus Bar of Twin Moose Conductor by tightening of all nut, bolts, clamps, jumpers including minor repairing work (Once in a year) (1X2=02)
Half yearly maintenance of following three phase isolators including its adjustment of arms, earth switch, oiling and greasing of mechanism for proper operation including replacement of damaged pats (Provided by the UPPTCL)
400 KV Pantograph Isolator without earth switch (2X21=42)
400 KV Pantograph Isolator with one earth switch (2X14=28)
400 KV Standard Isolator with one earth switch (2X4=08)
400 KV Standard Isolator with two earth switch (2X10=20)
220 KV Standard Isolator with two earth switch (2X12=24
220 KV Standard Isolator with one earth switch (2X14=28)
220 KV Tendom Isolator without earth switch (2X26=52)
132 KV Standard Isolator (2X8=16)
132 KV Tendom Isolator (2X3=06)
Maintenance of 400 KV FSC System installed at 400 KV Unnao-Bareilly-I & II including isolators, CBs, Platform, jumper etc. (six monthly) (2X2=04)
Tightening of jumpers clamps etc. of 400 KV Bay of various feeders (Six monthly) (2X12=24)
Tightening of jumpers clamps etc. of 220 KV Bay of various feeders (Six monthly) (2X14=28)
Tightening of jumpers clamps etc. of 132 KV Bay of various feeders (Six monthly) (2X4=08)
Cleaning of inside of control panel, relay panel, 220 Volt and 48 Volt DCDB panel, 220 Volt & 48 Volt Battery Charger by air blower and soft brush (as per required) to remove deposited dust and other foreign material (monthly basis) (12X70=840)
Cleaning of inside of 415 Volt ACDB panel by air blower and soft brush to remove deposited dust and other foreign material (monthly basis) (12X2=24)
M/S AARADHYA AND ADHYATM ASSOCIATES
SHRI RADHEY ASSOCIATES
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .