Chief Engineer Bhopal Zone
HQ Chief Engineer Bhopal Zone MES Bhopal
COMPLETION OF INCOMPLETE WORKS FOR PROVN OF SEWAGE LINE NETWORK INCLUDING WATER SUPPLY, ELECTRIC SUPPLY AND B/R SERVICES FOR CENTRAL SEWAGE SCHEME AT MRC SAUGOR
2022_MES_557525_1
CA NO. CEBZ/SAG/TOKEN/ 16 OF 2022-23
Open Tender
Civil Works
Lump-sum
300 days
SAUGOR
As per NIT
5 documents required · 5 mandatory
₹2,000
GARRISON ENGINEER SAGAR
₹2.9 L
Bhopal
17 Feb 2023
13 Oct 2022
5 Dec 2022
13 Oct 2022
2 Dec 2022
18 Nov 2022
27 Oct 2022
Amount
Note:-(i) Please refer schedule 'A' notes before quoting the tender. (ii) Amount of Schedule of credit shall be deducted off line by the department.
GENERAL SUMMARY
SCHEDULE 'A' PART - I (BUILDING WORKS)
Construction of RCC drop man hole (break Pressure Tank) 1.50 mtr dia and 1.80 mtr depth complete all as specified and shown on drawings.
Completion of incomplete works of Construction of sludge drying bed for STP complete all as specified & shown on drawings. NOTE: The details of completed percentage of work by the previous contractor w.r.t. approved yardstick along with brief list of balanced work is given in Appx 'X'.
Completion of incomplete works and rectification of defects of Construction of lift well No. 2 complete all as specified and shown on drawings. (All pipes & fittings, pump, chain & pulley shall be meaured and paid under relevant schedules) NOTE: 1. The details of completed percentage of work by the previous contractor w.r.t. approved yardstick along with brief list of balanced work is given in Appx 'Y'. 2. The list of defects is as per Para 1 of Appx 'Z'.
Rectification of defects in Pump House building as listed in Para 2 of Appx 'Z'.
Rectification of defects in Underground Sump as listed in Para 3 of Appx 'Z'.
Rectification of defects in Lift well No.1 and additional lift well at B ground as listed in Para 4 of Appx 'Z'.
Rectification of defects in Lab Room as listed in Para 5 of Appx 'Z'.
Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part- II (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part- III (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part- IV (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part- V (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for ROAD, PATH, CULVERT AND HARD STANDING as listed in Schedule ‘A’ Part- VI (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part- VII (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Schedule ‘A’ Part-VIII (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for COMPOUND WALL, FENCING & GATE as listed in Schedule ‘A’ Part- IX (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for RETAINING WALL as listed in Schedule ‘A’ Part- X (Ref prepriced schedule attached seperately)
Lump sum price worked out by the contractor for SITE CLEARANCE, EXCAVATION AND EARTH WORK as listed in Schedule ‘A’ Part- XI (Ref prepriced schedule attached separately)
SCH 'A' Pt - XII (MISCELLANEOUS ITEMS) (Contains Ser item No 4.00 to Ser item No 7.31)
INTERNAL ELECTRIFICATION NOTE:- For items of internal Electrifications notes given at the beginning of Sch ‘A’ Part-III shall also be applicable.
Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked with valid CML No. in and including medium grade, PVC concealed conduit dia not less than 20mm and conduit accessories concealed in wall/roof/floor etc, ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories), with mild steel/pressed steel sunken box not less than 1.6mm thick( with earth dolly) duly painted with two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally, and two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets and fan regulators etc, including PVC insulated multi-stranded copper conductor 1.5 Sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for the following:- (NOTE: Switch and socket to be measured and paid for separately)
(a) One light point controlled by one 5/6 amps one way switch.
Supplying and fixing TV coaxial socket outlet for TV signals complete with connections, Make- MK cat No W26451 or equivalent in Anchor, Finolex.
Supplying and fixing of telephone socket outlet, two pin , piano, flush type , with MS mounting box, hilum sheet, ISI maked with valid CML No compete all as specified Make- Cat No Z-1131 of plaza or equivalent in Anchor/ Finolex/cona.
MCB SPN 240V single pole and neutral breaking capacity 10 KA with 'B' characterstics complete all as specified. (a) SPN 10 Amp
Supplying and fixing fluorescent tube light fitting, box type, single tube 1X36 Watt complete with copper polyester ballast, capacitor, spring loaded type lamp holder, starter holder, starter, connector block etc prewired including aconite sheet direct to wall/ ceiling including fluorescent type with 23/0.0076 twin core PVC flexible cable etc and connection complete all as directed. Make: Philips. Bajaj, Crompton Greaves or equivalent.
Supply and fixing batten holder with built in choke CFL 20 watt including lamp complete with valid ISI marked and CML NO. complete all as specified, Make-for holder:- Anchor, Plaza, Cona, Crabtree & Makes for Lamp:- Philips, Osram, Surya, Crompton Greaves.
Sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of nominal cross section area as under and drawing into and including PVC non metallic rigid conduit medium grade not less than 25mm dia concealed including PVC insulated stranded copper conductor nominal cross section area as under of continuous earth wire complete all as specified:-
(a) Two runs of 4 Sq mm as current carrying conductor and one run of 2.5 Sq mm as earth conductor. Note: - Two runs of 4 sqmm cable and one run of 2.5 sqmm cable of earth continuity conductor and one run of PVC conduit shall be measured as one unit length.
S & F wall/ ceiling mounted luminaries suitable for and including 1x 11 Watt compact fluorescent lamp comprising of low loss O. C. Copper ballast impregnated, end caps to match the profile of lamp and luminaries housing made of ABS, UV stabilised prismatic diffuser for protection and elimination of lamp, glare, white reflector base for higher density, pre-phosphate and powder coated CRCA steel channel complete with all accessories like copper ballast, lamp holder all pre wired up to a terminal block complete all as specified. Make: Philips cat No. FMC 200/111 utilite or equivalent of Bajaj, Crompton Greaves, Wipro.
Supply and fixing CFL Roadway lighting Luminaries Epoxy black powder coated sheet steel housing with epoxy white powder coated CRCA Sheet steel gear tray, clear acrylic cover, aluminium reflector and accessories complete with two nos pin type CFL of 36 watts including provision of weather proof PVC insulated copper conductor cable 1.5 Sqmm, 2 core as required and 40 mm bore light grade G. I. tube mounting bracket of 1.5 Mtr in length, bend to shape at 140 degree in ‘L’ shape and fixed to wall /pole by means of 02 nos. of 40 x 6 mm flat iron clamps, 150mm 8mm dia bolts, nuts, and washers etc all as specified and directed. Make: Bajaj cat No. BJSLF 336 CFL MS or equivalent in Philips, Wipro & Crompton greaves
EXTERNAL WATER SUPPLY
Supply, fixing, testing and commissioning Double flanged non-rising stem type cast iron sluice valve with hand wheel and suitable for pressure rating of PN : 1.0 duly drilled holes for fixing of nuts and bolts, stem made of high tensile brass ISI marked including rubber gasket, nuts, bolts and washers complete all as specified of the following sizes :- Note:- Spindle of sluice valve to be painted in violet colour and must be detachable so that after operation these are kept in safe custody.
(a) 100mm NB
Supply, fix on the supply mains, and testing of cast iron single small orifice Air Release valve with two air outlets, suitable for working pressure of 10 Kgf/cm2 with 50mm dia high pressure ball and 1.56mm ( 1/16 inches) orifice complete including flanged joint all as specified and directed.
Construction of brick masonry valve pit of size 1050mm x 750mm x 1000 mm complete with Mild steel sheet cover 6mm thick and angle iron frame of size 40 x 40 x6 mm duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and incl locking arrangement and lifting handle all as specified and directed. All inner surface of pit shall be plastered in cement mortar (1:4) 15 mm thick complete, for sluice valve of size 100 to 200 mm dia incl excavation and earth work in any type of soil complete all as directed by Engineer in charge.
Construction of brick masonry valve pit of size 450mm x 450mm x 600 mm complete with Mild steel sheet cover 6mm thick and angle iron frame of size 40 x 40 x6 mm duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and incl locking arrangement and lifting handle all as specified and directed. All inner surface of pit shall be plastered in cement mortar (1:4) 15 mm thick complete, for gate valve 50/25 mm dia, incl excavation and earth work in any type of soil complete all as directed by Engineer in charge.
Supplying, installation, testing and commissioning of hand operated chain pulley block with hook and pulling chain complete ISI marked make INDEF/ HERCULES/ SWIFT complete of capacity 1 ton mounted on and including ISMB at height not less than 5 mtrs all as specified and directed.
Supplying fixing and tesing commissioning Double flanged cast iron swing check type reflux (Non return) valve single door pattern confirming to IS 5312 (part-I) - 1969 duly driled holes for fixing nuts and bolts including rubber gasket nuts bolts and washers complete all as specified and directed and of following size:-.
(a) 150 mm NB
SEWAGE DISPOSAL (E/M)
Supplying, fixing, testing and commissioning Double flanged cast iron swing check type reflux ( Non Return ) valve single door pattern conforming to IS : 5312 ( part – I ) – 1969, duly drilled holes for fixing nuts and bolts including rubber gasket, nuts, bolts and washers complete all as specified and directed and of following size :-
(a) 100 mm NB
Supply, lay, connecting and testing DI pressure pipes ”ISI” marked to IS 8329/2000(Reaffirmed-2005) Edition 4.1 of following sizes with socket spigot ends suitable for “Push –on joint” in standard working lengths supplied with a rubber gasket duly “ISI” marked for water supply class K-9 with socket and with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe without polyethylene sleeve but including “Push-on joint” supplied with “ISI” marked EPDM Rubber gasket conforming to IS-5382/1985(Reaffirmed 2003) with dual hardness of Type-2(bulb) and Type-5(Heel) quality-
(a) 100 mm dia ( for pressure pipe at SPS-1)
Supply, install, testing and commissioning Non clog submersible sewage pump electric driven capable of pumping out sewage effluent containing solid up to 40 mm size having of discharge 30 LPS and 20 Mtr head complete with suitable electric motor closed complete construction with suitable starter fully automatic star delta including provision for single phase preventer and automatic control for switching ON/OFF with sewage effluent level indicator arrangements including suitable duct foot bend automatic coupling device provision for its installation and suitable submersible PVC copper multi stranded cable from starter to motor including panel board up to motor including its fixing cum lowering/ raising arrangements with grade wise and MS galvanised chain as required complete all as directed by GE. Make : Pump set :- Kirlosker/ KSB/ Calama/Jyoti/ MDH, Starter and Single preventer :- L&T/ Crompton Greaves/ Jyoti/ Siemens/ Bentex. Note :- Rate quoted shall include for RCC/PCC work required for installation of pumping set including duck foot bend and clamps -2 sets etc required for smooth and efficient running and provision of MS galvanised chain/ wire rope and guide wire of suitable size as recommended by the manufacturer for arranging lowering and flushing out the pump for its installation/ repair/ maintenance etc as required.
All as per item Nos 6.05 here in before but 5 LPS and 30 mtr head complete.
EXTERNAL ELECTRIC SUPPLY
M&L Non linear resistor type surge arrestor (lightening arrestor) confirming to IS 3070 (Pt-I) having voltage rating 12 KV, Rated frequency-50 Hz, Nominal Discharge current 10 KA (Heavy duty) complete with all fittings suitable for 11 KV, 3 phase earthed distribution system complete all as specified.
Supply, erecting, testing and commissioning complete of manufacturer or OEM manufactured, static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 160 KVA (128 kw), water cooled, 415 Volts (AC three phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardised by manufacturer, fuel tank with mounting arrangements and inlet, outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Saugor (Capacity of Engine, alternators shall be worked out taking all derating factors into consideration) including PCC foundation (of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height), anti-vibration pads, including all features to comply with latest CPCB guidelines and comprising of following:-
Continued Sr Item no. 7.02 (v) ACCOUSTIC ENCLOSURE:- Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75% load under field condition and ox, 70DB at 3 M from Gen set when DG set is working at full load along with testing conformance, labelling certification etc as laid down in GSR No 371(E) dt 17 May 2002. (vi) FOUNDATION/PLINTH/BASE:-Shall be provided as per manufacturer’s recommendations, however minimum 0.5m Space should be available all around the Set and height of plinth shall not be less than 0.5 M. (vii) MISC: Tool kit, Operation and Maintenance catalogue, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. Make: Bajaj Cat no. BJSLF 336 CFL MS or equivalent in Phillips, Wipro & Crompton Greaves.
Supply, erecting, testing and commissioning complete of manufacturer or OEM manufactured, static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 5 KVA (4 kw), water cooled, 415 Volts (AC three phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardised by manufacturer, fuel tank with mounting arrangements and inlet, outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Saugor (Capacity of Engine, alternators shall be worked out taking all derating factors into consideration) including PCC foundation (of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height), anti-vibration pads, including all features to comply with latest CPCB guidelines and comprising of following:-
Continued Sr Item no. 7.05 (i) ENGINE(Prime Mover): Diesel Engine 1500 RPM, direct injection, 6 cylinders, four stroke, confirming to ISO3046/BS 5514, water cooled, naturally turbo charged, capable of giving adequate BHP to drive Alternator capable of delivering 5 KVA (4 kw) at outdoor atmospheric conditions at Saugor, (Taking all derating factor into consideration), 12/24 Volt (as per manufacturer recommendations) electric battery start, complete with fly wheel all standard fittings/fixtures as per manufacturer and including suitable panel with tachometer, lub oil temperature, pressure gauge and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and Engine protection system (Shut down, High water temperature, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other consumables etc . (ii)ALTERNATOR:- Brushless AC alternator, 3 Phase, 415 Volt, 4 wire, confirming to IS-13364, rated for output of 5 KVA, Minimum power factor 0.8, 1500 RPM, IP-23 Protection class enclosure, insulation Class "H", salient pole, revolving field, single bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine. (iii) BASE PLATE: - Made out of structural steel as per manufacturer’s recommended design/specifications. (iv) CONTROL PANEL:- Factory made cubical type floor mounted LT panel board, indoor type made out of MS angle not less than 25x25x5 mm and 1.6 mm thick MS CRCA sheet , front opening type, protection class IP-54 duly powder coated after seven tank process, with electrolytic grade copper bus bar of suitable capacity for four poles, with all standard switchgear and protection, measuring instrument suitable capacity of MCCBs for incoming and outgoing connection incl internal wiring of adequate size PVC insulated multi stranded copper conductor cable etc. (v) FOUNDATION/PLINTH/BASE:-Shall be provided as per manufacturer’s recommendations, however minimum 0.5m Space should be available all around the Set and height of plinth shall not be less than 0.5 M. (vi) MISC: Tool kit, Operation and Maintenance catalogue, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. “Make: Bajaj cat No. BJSLF 336 CFL MS or equivalent in Philips, Wipro & Crompton greaves”
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts indoor type, factory made free standing, floor mounting, dust and vermin proof cubical type, LT panel fabricated from 3.0mm thick ( minimum) CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), fully compartmentalized design with 4 Nos of bus bars made of copper suitable for 630 amps pre-wired with suitable size of copper strip, short circuit rating 36 KA (rms) for one second including suitable aluminium earth strips conforming to IS and all as specified with supply and fixing the following:-
Suppy , install testing and commissioning of factory made and tested outdoor type floor mounted LT panel board cubicle type suitable for 415 volts 3 phase 4 wire 50 Hz, AC supply system having bus bar chamber with air insulated PVC sleeved on copper bus bar of rating 400 Amps for phase and neutral installed on porcelain insulators. The panel made out of 3.0 mm thickness CRCA sheet and 25x25x6 mm thick MS angle iron frame work front opening type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm and comprising of followings:-
Continued Sr Item no. 7.09 (A) Incoming- (a) MCCB 400 amps 4 pole ultimate breaking capacity 25 KA with Thermal magnetic releases suitable for 415V and conforming to IEC-60947-2 and IS :13947-2 complete all as specified ( 01 No.) (b) Three Nos Phase indication lamps: backup with HRC fuse/MCB (c) Digital Voltmeter, digital Ammeter with required CTs. (d) ON LOAD Change over switch FRONT OPERATED, 400 Amps, 415 V, 50 Hz, suitable for stand by power supply- 01 No. (B) Out goings (a) MCCB 160 amps 4 pole ultimate breaking capacity 25 KA with fixed Thermal magnetic releases and conforming to IEC-60947-2 and IS :13947-3 complete all as specified (04 Nos.) (b) MCB DP 63 amps- 02 Nos (c) Internal wiring with single core copper conductor cables/PVC insulated copper strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1 Job. (d) Cable chamber of suitable size for outgoing cables (e) Fine wiring with single core copper conductor cable for instrument/indicating lamp- 01 Job. (f) Platform for LT panel board with PCC 1:2:4 type B1 using 20mm graded stone aggregate 15cm thick in foundation complete all as directed by Engr in charge. Note:- LT panel board/switch gear shall be fabricated as per clause No. 19.100 as per SSR Pt-I
Suppy , install testing and commissioning of factory made and tested outdoor type floor mounted LT panel board cubicle type suitable for 415 volts 3 phase 4 wire 50 Hz, AC supply system having bus bar chamber with air insulated PVC sleeved on copper bus bar of rating 200 Amps for phase and neutral installed on porcelain insulators. The panel made out of 3.0 mm thickness CRCA sheet and 25x25x6 mm thick MS angle iron frame work front opening type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm and comprising of followings:-
Continued Sr Item no. 7.11 (A) Incoming- (a) MCCB 160 amps 4 pole ultimate breaking capacity 25 KA with fixed Thermal magnetic releases and conforming to IEC-60947-2 and IS :13947-3 complete all as specified (01 No.) (b) Three Nos Phase indication lamps: backup with HRC fuse/MCB (c) Digital Voltmeter, digital Ammeter with required CTs. (B) Out goings - (a) MCCB 100 amps 4 pole ultimate breaking capacity 25 KA with fixed Thermal magnetic releases and conforming to IEC-60947-2 and IS :13947-3 complete all as specified (02 Nos.) (b) MCB DP 63 amps- 01 No. (c) Provn of Star Delta starter suitable for 20 HP pumping set, 3 phase, complete with under voltage and overload protection, single phase preventer and mounting in main electric panel ( Electric panel to be paid for separately) and also incl necessary wiring with PVC insulated and unsheathed copper conductor cable multi stranded of suitable size, concealed in light grade GI or flexible pipe all as specified and directed- 02 Nos (d) Internal wiring with single core copper conductor cables/PVC insulated copper strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1 Job. (e) Cable chamber of suitable size for outgoing cables (f) Fine wiring with single core copper conductor cable for instrument/indicating lamp- 01 Job. (g) Platform for LT panel board with PCC 1:2:4 type B1 using 20mm graded stone aggregate 15cm thick in foundation complete all as directed by Engineer in charge. Note:- LT panel board/switch gear shall be fabricated as per clause No. 19.100 as per SSR Pt-I
SEWAGE DISPOSAL (B/R)
Emptying of septic tank of capacity 100 users and above in foul conditon, taking out sludge disposing of sludge not less than 5 KM lead and refilling with local earth in layers not exceeding 25 cm , including ramming and compaction , cleaning of site all as specified and directed.
Emptying of soakage well of capacity 100 users and above in foul conditon, taking out sludge disposing of sludge not less than 5 KM lead and refilling with local earth in layers not exceeding 25 cm , including ramming and compaction , cleaning of site all as specified and directed.
DROP MH
Supply, laying, connecting, jointing and testing ductile iron K9 Pipe including bend, Tee, socket etc for drop manhole, ISI marked, IS 8329/2000 (3rd revision) with approved quality rubber rings (tyton joints) EPDM/SBR quality confirming to IS 5382-1985, stacking in position, lowering in approved trenches under dry, wet or foul conditon, laying in proper aligment and grade complete all as specified and directed of following dia:-
(a) 150 mm dia
(b) 200 mm dia
(c) 300 mm dia
(d) 400 mm dia
M&L for CI vent 90cm long on top including mild steel 10 mm square bar 100 mm x100 mm mesh size fixed with PCC 1:2:4 type B-1 of size 60x60x20 cm all round complete all as specified and directed of following bores:-
(a) 150 mm dia
(b) 200 mm dia
(c) 300 mm dia
(d) 400 mm dia
M&L for transfering sewage flow from existing MH chamber to new MH chamber on new sewer with connecting branches with RCC pipe class NP2 of following size including providing pipes, lowering , laying in position in proper grade and alignment, jointing, testing, including disconnectng flow further to MH chamber or bypassing existing septic tank permanenetly & including excavation to depth required in any type of soil in dry, wet or foul condition , dewatering , 15 cm PCC 1:4:8 type D2 in bedding including packing under an haunching against sides of pipe after they are laid and tested, refilling with sand boxing for min 50 cm above crown of pipe and moorum on top complete all as specified and directed.
(a) 150 mm dia
(b) 200 mm dia
RCC MH
S&F 200 mm wide PVC water bar all as specified and shown on drawing.
ROAD / PATH / CULVERT
M&L for sand stone pattie edging of rough squared stone of 50 to 60mm thick and 300 mm deep, 50 to 60 cm length jointed struck flush all as directed.
M&L for painting Road line 100mm wide with golden yellow/white thermostatic compound with reflective glass beeds on bitumen road providing and laying hot applied thermostatic compound 2.5 mm thick incl reflectorised glass beeds @ 250 gms per sqm area thickness of 2.5 mm is exclusive of surface applied glass beeds as per IRC -35 incl cleaning of peeled of road marking paint, the finished surfaces to be uniform level and free from streaks and holes filled additon where arrow of letter to be provided thermostatic compound may be hand/machine spread all as specified and directed. The colour of compound shall be as directed.
S&F by-directional reflective type road studs illuminated yellow both side of rectangular/square shape made up of thermoplastic body fixed on road with bitumen adhesive and nails as per manuacturer's instructions having abrasion resistance ceramer coating and reflective surface complete all as specified and directed make 3M or equivalent.
Raja enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .