Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-Finance | L1 | Accepted-Finance 1st Lowest | |
| 2 | L2₹11.3 L+₹2.5 L (28.2%)Accepted-Finance | L2 | Accepted-Finance 2nd Lowest |
Tender Value
₹17.6 L
EMD Value
₹35,242
Closing Date
24 Feb 2026, 3:00 pmClosed
EE,CD,APWD,CAR NICOBAR
Office of the Executive Engineer Construction Division APWD Car Nicobar
Renovation of IEI,EEI including installation of Motor control Panel and Busbar Chamber at Headquarter pump house, Perka Car Nicobar.
2026_APWD_21851_1
e-tender-DB/CD/CN/2025-26/278
Open Tender
Electrical Works
Percentage
90 days
At HQ Pump house perka CN
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹35,242
Yes
26 Feb 2026
10 Feb 2026
24 Feb 2026
10 Feb 2026
24 Feb 2026
11 Feb 2026
11 Feb 2026 - 12 Feb 2026
Supplying and Fixing Integrated All-in-one Solar Street Light 45 watts , efficacy more than 175 lumens/watt , Equiped IN sensor with Lithium ferro Phosphate battery, solar panel and charger built into the luminarie, Pressure die cast aluminium fitting Make Philips, Model Sunstay, BRP710LED45 CW MR S1 12 V LFP AIO Solar Equip IN-with sensor or equivalent Make- Bajaj, Crompton, Havells on the existing pole
Supplying of LED Batten Luminaire 20 watts comprises of extruded aluminium housing,polycarbonate diffuser Make Philips Model BN170CLED20S-6500 PSUL120 or Equivalent Make- Crompton, Bajaj, Havells
Supplying of BEE- 5 star energy efficient BLDC Ceiling fan (1200mm sweep) without Remote for operation of 230v, i/c wiring down rod standard length (upto 30Cm) with all accessories etc as required. Make:- Crompton, Energion Riviera (w/o Remote) or Equivalent Make Havells, Usha, Bajaj
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring with the down rods of standard length (up to 30 cm) with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc, directly on ceiling / wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface / recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way, Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 KA "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying, Installation, testing and commissioning of ASHLOK make SEE brand safe earthing electro type-19, 50mm dia,length 2 mtrs and inner space to be filled with crystaline conductive mixture including filling up with electrodite (Back fill compound) as required for safe earth electrode and providing masonary enclosure with cover plate having locking arrangement etc. as required.
Providing and laying earth connection from earth electrode with 4.00mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and refilling as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Supplying of following size ISI marked PVC insulated and PVC sheathed/ XLPE (heavy duty) 1.1 KV grade ArmouredAluminium conductor cable conforming to IS:7098 (Part - I ).
150 sqmm x 3.5 core
25 sqmm x 3.5 core
Laying of one number PVC sheathed /XLPE power cable of 1.1 KV grade of following size in the existing DWC/Hume/Metal pipe as required.
a) Upto 35 sq.mm
b)Above 95 sq. mm and upto 185 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
a)Upto 35 sq. mm (clamped with 1mm thick saddle)
Supplying and laying of one number double walled corrugated high density polyethlene pipe having corrugation on the outer wall and plain surface inner wall confirming to IS: 16205 ( PART-24-2018) Complete with necessary HDPE fittigs for protection of 1.1 KV grade under ground cable directly in ground at a depth of 50 cm i/c excavation and refilling the trench.
40mm outer dia and 32mm inner dia
63mm outer dia and 50mm inner dia
Supplying and laying of one number double walled corrugated high density polyethlene pipe having corrugation on the outer wall and plain surface inner wall confirming to IS: 16205 (PART-24-2018) Complete with necessary HDPE fittigs for protection of 1.1 KV grade under ground cable directly of following size on wall surface as required
40mm outer dia and 32mm inner dia
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR LS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch,modular plate, suitable size G.I/PVC box and earthing the point with 1.5 sq.mm. FR LS PVC insulated copper conductor single core cable etc as required- Group C
Wiring for light/power plug with 2x4 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit alongwith 1 No 4 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/sub main wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required.
2x 2.5 sq.mm + 1x 2.5 sq.mm earth wire.
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and Fixing 4-Way Current Rating 400 Amps Busbar Chamber Make Havells Item Code IHBC040004 or any equivalent make as per the above specification
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.14 MB
TenderDocument30HP.pdf
Tender Documents • 1.40 MB
BOQ_23129.xls
BOQ • 0.33 MB
Instructions-to-bidders.pdf
Additional Documents • 0.33 MB
Corrigendum.pdf
PDF • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .