| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.1 LAccepted-AOC 30 SHIVTALLA STREET KOLKATA 700 007 | KOLKATA | KOLKATA | WEST BENGAL | 700007 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹35.1 L+₹86,574 (2.53%)Rejected-Finance 15 1 1F MAYUR BHANJ ROAD POLICE STATION EKBALPORE KOLKATA 700023 | KOLKATA | KOLKATA | WEST BENGAL | 700023 | L2 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 3 | L3₹37.8 L+₹3.6 L (10.6%)Rejected-Finance | L3 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 4 | L4₹44.5 L+₹10.3 L (30.2%)Rejected-Finance 6A BANAMALI GHOSHAL LANE KOLKATA 700034 | KOLKATA | WEST BENGAL | 700034 | L4 | Rejected-Finance HIGHER THEN L1 BIDDER |
| Sl No | Description | Qty | Unit | SUDHA ENTERPRISES L1 | DILIP CONSTRUCTION L3 | DIPAK ENTERPRISE L2 | AUTO ELECTRICALS L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of cement concrete (Un-reinforced) in ground floor and paving nexc 15cm thick above or below GL complete all as specified and directed | 3 | Cum | 1,200 ₹3,600 Lowest | 1,379 ₹4,137 | 1,238 ₹3,714 | 1,400 ₹4,200 |
| 2.00 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in mortar complete all as specified and directed. | 0.8 | X Sqm | 534 ₹427.2 | 600 ₹480 | 530 ₹424 Lowest | 650 ₹520 |
| 3.00 | Dismantling floors hearth or wall tilling including cement mortor bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed | 87 | Sqm | 75 ₹6,525 | 85 ₹7,395 | 70 ₹6,090 Lowest | 90 ₹7,830 |
| 4.00 | Demolition of brick work or stone masonry built in cement mortor including all quoins & jambs etc. complete all as specified and directed | 1 | Cum | 80 ₹80 | 90 ₹90 | 70 ₹70 Lowest | 595 ₹595 |
| 5.00 | Taking down cement plaster of any description on brick work or stone masonry wall including racking ot joints hacking for key scrubbing down with water etc. complete all as specified and directed | 150 | Sqm | 80 ₹12,000 | 90 ₹13,500 | 70 ₹10,500 Lowest | 95 ₹14,250 |
| 6.00 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as directed and directed | 1 | Cum | 1,602 ₹1,602 | 1,800 ₹1,800 | 1,600 ₹1,600 Lowest | 1,890 ₹1,890 |
| 7.00 | Taking down chowkhats or frames with shutters (without taking off shutter from frames) of any sizes nexc 1.5 Sqm complete all as specified and directed. | 30 | Each | 249 ₹7,470 Lowest | 280 ₹8,400 | 256 ₹7,680 | 290 ₹8,700 |
| 8.00 | All as item No. 07 above but exc 1.5 Sqm and nexc 4.0 Sqm each. | 22 | Each | 311 ₹6,842 Lowest | 350 ₹7,700 | 320 ₹7,040 | 360 ₹7,920 |
| 9.00 | Taking down of shutters of any description nexc 1.0 Sqm each complete all as specified and directed | 20 | Per leaf | 79 ₹1,580 Lowest | 89 ₹1,780 | 81 ₹1,620 | 95 ₹1,900 |
| 10.00 | Taking down of shutters of any description exc 1.0 Sqm and nexc 2.0 Sqm each complete all as specified and directed. | 10 | Per leaf | 79 ₹790 Lowest | 89 ₹890 | 81 ₹810 | 95 ₹950 |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
19 Sept 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI RAKESH KUMAR
GARRISON ENGINEER CENTRAL KOLKATA NAPIER ROAD HASTINGS - 700022
WELCOME MAINTENANCE TO OFFR QTRS AT BMC UNDER GE (C) KOLKATA
2025_MES_725979_1
8840/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
Kolkata
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE(CENTRAL) KOLKATA
₹68,000
Yes
27 Nov 2025
21 Aug 2025
20 Sept 2025
21 Aug 2025
19 Sept 2025
5 Sept 2025
21 Aug 2025 - 4 Sept 2025
Amount
Demolition of cement concrete (Un-reinforced) in ground floor and paving nexc 15cm thick above or below GL complete all as specified and directed
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in mortar complete all as specified and directed.
Dismantling floors hearth or wall tilling including cement mortor bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
Demolition of brick work or stone masonry built in cement mortor including all quoins & jambs etc. complete all as specified and directed
Taking down cement plaster of any description on brick work or stone masonry wall including racking ot joints hacking for key scrubbing down with water etc. complete all as specified and directed
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as directed and directed
Taking down chowkhats or frames with shutters (without taking off shutter from frames) of any sizes nexc 1.5 Sqm complete all as specified and directed.
All as item No. 07 above but exc 1.5 Sqm and nexc 4.0 Sqm each.
Taking down of shutters of any description nexc 1.0 Sqm each complete all as specified and directed
Taking down of shutters of any description exc 1.0 Sqm and nexc 2.0 Sqm each complete all as specified and directed.
Taking up or down steel tubing 15mm dia and connection complete all as specified and directed
All as per item No. 11 above but 20mm dia bore.
M&L fly ash bricks pulverizes using class designation 75 (kgf/cm2) bricks straight or curved on plan exc 6m mean radius built in CM (1:6) complete all as specified and directed.
M&L half brick thick brick work with class designation 75 (kgf/cm2) fly ash bricks pulverizes straight or curved on plan exc 6m mean radius built in CM (1:4) complete all as specified and directed
M&L for applying polymer modified cement mortar rendering 20mm thick in CM 1:3 on wall duly mixing polymer modifier "Nitobond SBR of M/s Forsoc Chemical India (Pvt) Ltd" or "Hind Styrene BR of Hindcon Chemical Ltd" or equivalent of M/s Pidilite Industries /Icannano @ 7 Liter per bag of cement complete finished even and smooth without using extra cement complete all as specified and as per manufacturer's specification.
M&L rendering 10mm thick in CM (1:6) on other than fair faces of brick work or concrete surfaces even & fair without using extra cement complete all as specified and directed
M&L rendering 15mm thick in CM (1:4) on fair faces of brick work or concrete surfaces finished the surfaces even and fair without using extra cement and using water proofing compound as per manufacturer instruction complete all as specified and directed
M&L rendering 5mm thick in CM (1:3) as in ceiling surfaces even & smooth without using extra cement complete all as specified and directed
Supply only liquid water proofing compound as required
Cutting chase, pinning in making good to facing where required and pointing in CM 1:3 to end or edges of landing steps, cills, sunshades, shelves, lintels etc. and cutting chase for concealed water pipe etc. and making good cutting not exc 10Cm girth.
S&F for 20mm outer diameter CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
S&F for 25mm outer diameter CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
S&F in repair for 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to wall complete all as specified and directed.
All as per item No. 23 here in before but double socketed complete all as specified and directed.
S&F in repair PVC (SWR) bend any radius 110mm bore complete all as specified and directed
S&F in repair PVC (SWR) junction single (single T) equal or unequal 110mm bore complete all as specified and directed.
M&L for diameter of outlet 75mm UPVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and as directed
S&F in repairs 125mm size PTMT Grating Doom with waste hole(Min weight 40 grms) , complete all as specified and as directed.
M&L mild steel TMT bars 10mm dia and over, cut to length bent to shape required including cranking, bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (anealed) not less than 0.9mm dia or securing with clips quality conforming to fe 410-S.
Formwork to soffits of suspended slabs such as roof slabs,floor,slabs,landings and similar work not exceeding 200mm thick rough finished surfaces without using extra cement(Horizontal or sloping )
M&L 25mm thick PCC (1:2:4) type B-0 (using 12.50mm graded stone aggregate) as in of floor, finish even and fair complete all as specified.
M&L Double charge light shade Vitrified Ceramic Tiles 8mm- 10 mm thick (square/ rectangular) , Polished, area of each tile not exc 0.36 sqm as in Floors, etc. Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Shade of the Tiles over 15mm thick screed bed in cement sand mortar (1:6) complete all as specified and as directed.
M&L Double charge light shade Vitrified Ceramic Tiles 8mm- 10 mm thick (square/ rectangular) , Polished, area of each tile not exc 0.36 sqm on Vertical Surfaces such as Skirting, Dados, Risers to Steps, etc., Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Shade of the Tiles over and including 10mm thick backing layer in cement mortar (1:4) complete all as specified and as directed.
M&L joint free non skid ceramic coloured tiles 8-10mm thick (square/rectangular) area of each tile exc 0.18 Sqm but not exc 0.38 Sqm in floor set and jointed in in neat cement slurry and pointed in cloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed
All as item No. 34 here in before but in skirting with and including 10mm thick rendering on fair faces of brickwork in CM 1:4 complete all as specified and directed.
M&L joint free non skid ceramic coloured tiles 8-10mm thick (square/rectangular) area of each tile exc 0.11 Sqm but not exc 0.18 Sqm in floor set and jointed in in neat cement slurry and pointed in cloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed
All as item No. 36 here in before but in skirting with and including 10mm thick rendering on fair faces of brickwork in CM 1:4 complete all as specified and directed.
M&L joint free non skid ceramic coloured tiles 7-8mm thick (square/rectangular) area of each tile exc 0.06 Sqm but not exc 0.11 Sqm in floor set and jointed in in neat cement slurry and pointed in cloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed
M&L glazed ceramic coloured tiles 200x300x7mm in vertical surfaces set and jointed in in neat cement slurry and pointed in cloured cement to match over and including 10mm thick rendering in CM 1:4 complete all as specified and directed
M&L glazed ceramic coloured tiles 450x300x6-7mm in vertical surfaces set and jointed in in neat cement slurry and pointed in cloured cement to match over and including 10mm thick rendering in CM 1:4 complete all as specified and directed
M&L RCC (Nominal Mix) 1:1.5:3 type A-1 (Using 20mm graded stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like similar works including Form work complete all as specified and directed.
M&L for Pressed steel frames 1.25mm thick for doors with one or more rebates size of frame 125 x 60 mm including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed complete all as specified and directed. Note:- Pressed Steel Frame should be filled with PCC 1:3:6 Type C-0 (Using 12.50mm graded stone aggregate) and cost of PCC shall be deemed included in quoted rate
M&L for Pressed steel frames 1.25mm thickness for doors with one or more rebates size of frame 105 x 60 mm including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed complete all as specified and directed. Note:- Pressed Steel Frame should be filled with PCC 1:3:6 Type C-0 (Using 12.50mm graded stone aggregate) and cost of PCC shall be deemed included in quoted rate
M&L for PCC 1:3:6 type C-1 using 20mm graded stone agg as in bed blocks/hold fast complete all as specified and directed
S&F 35mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides fitted to cowkhats complete all as specified and directed
S&F for 2nd class hardwood 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats as specified in SSR Part-I 2009.
S&F for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening complete all as specified and directed.
S&F for Factory Made Solid PVC Moulded Door Shutter With Wood free EPS, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick 3D wood grain Moulded PVC Sheet Polyurethane painted on the front face & 2mm prelam PVC Sheet on back face, supplying & fixing in frame at site complete all as specified and directed.
Providing and fixing factory made uPVC white colour sliding window (Area of each window not exceeding 2.00 sqm) Three track made of extrueded profiles with wall thickness of 2.3mm (+-0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52 mm), sliding sash (42mm x 67mm). Sliding mesh sash (42mmx57mm) Sliding interlock (one vertical length in each shutters) (45.5mmx28mm), Glazing bead (24.5mmx16mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2 (+-0.2mm) thick galvanised steel fr Frame (30mmx18mm) 2 Nos, sliding sash (30mmx18mm) , sliding mesh sash (36mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mmx 100mm long fasteners, hardware (Touch Lock of Zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40 mm and required accessories (Note:- The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured for payment purpose.)
M&L 1.50mm thick power coated aluminium , three track sliding window with three nos shutters made of aluminium section as per drawing no CWE/KOL/TD-33 of section no 1F-1F including necessary jointing cleats, glazing clips, rubber neoprene packing, roller, locking arrangement, handles 2 Nos , anodised aluminium snap beading screws etc.Complete all as specified and as directed. Note Nos :- (i) All window member including fitting & fixture i.e frame, track, shutter frame, etc shall be deem to included quoted rate. Only measure opening size of window. (ii) Only Glass for window & wire mesh shall be measure and paid separately under relevant items of BOQ .
S&F powder coated aluminium ventilators with louvers and glazing including frame of section over all size of window 600X450mm complete with following specification . (a) Alu frames of size 45x45x1.2mm (b) Rail & Stile 45x45x1.2mm thick (c) 4.80mm thick frosted sheet glass Note :- All ventilators/louvers member including fitting & fixture shall be deem to included quoted rate. Only measure opening size of ventilators/louvers
Supply and fixing of tinted glass with sheet glass 4.80mm thick , pin head type and glazing in squares exc 0.5 sq. M in each pane complete all as specified and as directed.
S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F in repair Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
Hacking out old broken glass any thickness size quality or description from metal frame including punching or drilling out old glazing pins/springs clips complete all as specified.
S&F 4mm thick sheet glass ordinary quality and glazing with oil putty in square nexc 0.5 Sqm each pane.
S&F 4mm thick frosted glass panes and glazing with oil putty in square nexc 0.5 Sqm each pane complete all as specified.
S&F 100mm Butt hinges, extruded brass, with brass hinge pin, bright polished, complete all as specified and directed
S&F Aluminium anodised, barrel tower bolts of extruded section 200mm long complete all as specified and directed
S&F Aluminium anodised, barrel tower bolts of extruded section, 150 mm long and fixed with steel screws complete all as specified and directed.
S&F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy of 300mm long complete all as specified and directed
S&F Extruded aluminium alloy handles, fabricated type, anodised 150mm long complete all as specified and directed
S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, 150mm long complete all as specified and directed
S&F Mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed.
S&F 20mm dia brass chromium plated tubular curtain rod with Chromium plated Bracket both side stops, rollers etc as in repair complete all as specified and as directed.
M&L 18/19 mm thick Medium density fibre board, exterior grade, fixed to timber framework with screws complete all as specified and directed.
S&F (piano) mild steel, bright finish or electro galvanised Width of flaps (When open) 30mm complete all as specified and directed.
S&F 40mm dia, cupboard knobs fixed with nut, screw and washer of brass polished bright finished as in repair complete all as specified and as directed.
S & F in repair for brass chromium plated two in one tap with Wall Flange screwed for 15 mm bore pipe complete all as specified and directed.
S & F work in repair for ABS body chrome plated shower rose 125mm size with shower arm 240mm long round shape with flage including fixing to steel pipe or union including fixing to steel pipe or union complete all as specified and directed
Supply and fix in repair stainless steel kitchen sink without drainage board of overall size 510mm x 430mm x203mm of bowl size 430mm x 380mm x203mm, made of 1mm thick stainless steel sheet with CP waste coupling including ball and chain 300mm long with brass cap rubber plug, 32mm bore PVC waste pipe(heavy duty) 90 Cm long, and bedded in cement mortar and fixed on CP cantilever brackets, complete as directed.
S & F in repair for 15mm bore brass chromium plated Angular Valve with Wall Flange complete all as specified and directed.
S & F in repair for 15mm bore brass chromium plated 2 Way Angular Valve with Wall Flange complete all as specified and directed.
S & F in repair for chromium plated Health faucet with 8mm Dia, 1.2 Meter long flexible tube and wall hook with N.R.V (Back Flow Preventer) complete all as specified and directed.
S & F in repair for Plastic water closet seat, in any coloure as directed closed pattern with flat/recessed bottom, and cover and mild steel chromium plated or aluminised hinging device for pedestal pan complete all as specified and colour as directed.
S & F in repair CP sink cock with swinging spout (wall mounted model) with Wall Flange screwed for CPVC pipe complete all as specified and colour as directed.
S & F in repair for 15mm bore brass chromium plated Wall Mixer with Provision for Overhead Shower with 115mm long Bend Pipe on Upper Side, Connecting Legs & Wall Flanges complete all as specified and directed.
S & F in repair for 15mm bore brass chromium plated Sink Mixer, Connecting Legs & Wall Flanges complete all as specified and directed.
S&F Central hole for Hot and Cold water supply basin mixer, brass chromium plated screwed down for iron pipes, including necessary fittings etc as in repair , complete all as specified and as directed.
Supply and fixing in repair Vitreous China wash down water closet pan including P or S trap (pedestal pattern), white (excluding flushing cistern and flush pipe) including plastic water closet seat, black colour , closed pattern with flat bottom, and cover and mild steel chromium plated or aluminized hinging device and wash down water closet complete all as specified and as directed.
S&F in repair vitreous china wash hand basin white of size 550 x 400mm excluding taps but including 32mm PTMT waste coupling (excluding 32mm waste pipe) complete all as specified and directed.
S&F in repair vitreous china squatting pan Orissa pattern size 580x440mm white with integral foot rest including connection to trap, and flushing pipe, anti-syphonage pipe, etc and including lime concrete bedding complete all as specified.
S&F in repair PVC flushing cistern low level 10 Ltr capacity of approved make including fixing of brackets connection to WC with CI brackets and making good disturbed area complete all as directed.
S&F in repair PVC connection 15mm size with PTMT nut of length 450mm complete all as specified and directed
S&F triple layer PVC water storage tank cylindrical, vertical with closed top hoisted and fixed in position tank capacity 500 Ltr with and including ball valve high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for 25mm outer diameter for CPVC pipe & making connection for inlet and outlet including dismantle of old water tank and removing from site complete all as specified & directed.
S&F triple layer PVC water storage tank cylindrical, vertical with closed top hoisted and fixed in position tank capacity 1000 Ltr with and including ball valve high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for 25mm outer diameter for CPVC pipe & making connection for inlet and outlet including dismantle of old water tank and removing from site complete all as specified & directed.
S&F Towel ring of size 150mm dia decorative type fixed with walls including necessary fittings etc as in repair complete all as specified and as directed.
S&F Brass chromium plated tubular towel rail, 20mm dia, D type, 60,cm long between flanges as in repair complete all as specified and directed.
S&F stainless steel utensil plate rack (size 24'' x 30'' x 10'') using 0.8mm thick sheet with all fittings accessories complete as directed.
S&F PVC bathroom cabinet (white) of size 500 x 400 x 100 mm (approx) with one single shutter and built in mirror in front of shutter, fixed on walls with wooden plugs and chromium plated brass screw and cup washed as in repair complete all as specified & directed.
S&F Glass shelf assembly consisting of 5.5 mm thick sheet glass self 19-12 cm wide, 60 cm long with chromium plated brackets guard and railing fixed in position with necessary fixing arrangement as in repair complete all as specified and directed.
M&L for preparation of new surfaces of wood and wood based materials of any descriptions not otherwise described over 10Cm width or girth & applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified.
M&L for preparation of old surfaces of wood or wood based materials of any description and applying one coat of synthetic enamel paint over 10 Cm width or girth complete all as specified.
M&L for preparation of new surfaces of Steel and Steel based materials of any descriptions not otherwise described over 10Cm width or girth & applying two coat of synthetic enamel paint over a coat of red oxide on steel surfaces complete all as specified.
M&L for preparation of old surfaces of steel or steel based materials of any description and applying one coat of synthetic enamel paint over 10 Cm width or girth complete all as specified.
M&L Preparing old surfaces of internal walls and applying one coats of white wash, complete all specified and directed.
M&L preparing newly plastered surfaces and applying 2 coat of oil bound distemper over a coat of primer including two coat of white cement based putty (approx 2mm thick) including rubbing with emery paper to make wall surface smooth and even complete all as specified and directed.
M&L preparing newly plastered ceiling surfaces and applying 2 coat of oil bound distemper over a coat of primer including two coat of white cement based putty (approx 3mm thick) including rubbing with emery paper to make wall surface smooth and even complete all as specified and directed.
M&L preparing old decorated surfaces and applying one coat of oil bound distemper complete all as specified and directed.
M&L preparing old decorated ceiling surfaces and applying one coat of oil bound distemper complete all as specified and directed.
M&L Complete removal of existing Treatment of old decorated Surfaces of Walls and applying Two Coats of Distemper Oil Emulsion over a coat of primer and applied over 1.5mm thick water proof wall care putty including rubbing with emery paper to make wall surface smooth and even complete all as specified and directed.
M&L preparing newly plastered surfaces and Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified & directed.
M&L preparing old decorated surfaces and Finishing walls with one coat of Acrylic Smooth exterior paint of required shade complete all as specified & directed.
Preparing old decorative Surfaces of walls and applying one Coat of cement base paint complete all as specified and as directed.
S&F for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed
M and L 20mm thick granite of any type tiles machine cut in skirting dado laid over cement screed bed 15mmthick in CM 1:3 beaded and jointed with grey cement slurry and jointed with white cement cement mortor (1:2) using marble dust with admixture to match with shade of granite complete all as Specified and directed
S&F in repair safety lever lock mild steel 4 lever for rolling shutter complete all as specified and directed
S&F in repair ball bearing for rolling shutter of existing type and size complete all as specified and directed
M&L for oiling and greasing of rolling shutter for smooth functioning for size nexc 7 Sqm each complete all as specified and directed
M&L Mirror polishing on marble/ granite/ Kota stone/ stone work where ever required to give high gloss finish complete all as specified & directed.
Taking down point wiring (light, fan, socket and power complete including fixtures and fittings such as switches ceiling roses, pendents , regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody for refixing or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. including cleaning all and specified and directed.
M&L for point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sq mm FRLH/S in and including concealed PVC conduit 20 mm dia medium duty ISI marked with all necessary fittings with sunken cast iron /pressed steel terminal box ,flush to surface of 1.6mm wall thickness and 3 mm thick laminated sheet top cover for mounting switches including 1.5 sq mm FRLH/S PVC insulated unsheathed stranded copper conductor as earth lead and connected to common earth doly for one light / ceiling fan/exhaust fan/bell controlled by one switch complete including cutting, chasing the surface and then making good the same in CM 1:3 to finishing the match surface complete all as specified and directed by Engr- in-charge.
All as per item No112.00 mentioned here-in-before but 3 pin 5 amps socket out let point same board with other switches of cables of 1.5 sqmm
All as per item No.112.00 mentioned here-in-before but for one 5 amp switch socket combination on independent board with cables of 1.5 sqmm size
All as per item No.112.00 mentioned here-in-before but using 2.5 sq mm size stranded copper conductor cable for one 16 amp switch socket outlet on independent board including 2.5 sq mm FRLH/S PVC insulated unsheathed stranded copper conductor as earth lead and connected to common earth doly complete all as specified and directed by engineer incharge.
All as per item No.112.00 mentioned here-in-before but using 4.0 sq mm size stranded copper conductor cable for one AC starter including 4.0 sq mm FRLH/S PVC insulated unsheathed stranded copper conductor as earth lead and connected to common earth doly complete all as specified and directed by engineer incharge.
M&L for point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sq mm FRLH/S in and including concealed PVC conduit 20 mm dia medium duty ISI marked with all necessary fittings for mounting modular switches including 1.5 sq mm FRLH/S PVC insulated unsheathed stranded copper conductor as earth lead and connected to common earth doly for one light / ceiling fan/exhaust fan/bell controlled by one switch complete including cutting, chasing the surface and then making good the same in CM 1:3 to finishing the match surface complete all as specified and directed by Engr- in-charge. Note:- Sunken flush metal GI boxes of 1.6mm wall thickness and modular cover plate with frame for mounting switches shall be measured and paid separately.
All as per item No117.00 mentioned here-in-before but 3 pin 5 amps socket out let point same board with other switches of cables of 1.5 sqmm
All as per item No.117.00 mentioned here-in-before but for one 5 amp switch socket combination on independent board with cables of 1.5 sqmm size
All as per item No.117.00 mentioned here-in-before but using 2.5 sq mm size stranded copper conductor cable for one 16 amp switch socket outlet on independent board including 2.5 sq mm FRLH/S PVC insulated unsheathed stranded copper conductor as earth lead and connected to common earth doly complete all as specified and directed by engineer incharge.
M&L for point wiring with PVC insulated unsheated stranded copper conductor cable FRLH/S of size 1.5 sq mm in and including PVC casing caping of required width with all necessary fittings with sunk cast iron /pressed steel terminal box of1.6mm wall thickness and 3 mm thick laminated sheet top cover for mounting switches including 1.5 sq mm FRLH/S PVC insulated unsheathed stranded copper conductor as earth lead and connected to common earth doly for one light / ceiling fan/exhaust fan / bell controlled by one switch , one way complete all as specified and directed by Engineer incharge.
All as per item No.121.00 mentioned here-in-before but 3 pin 5 amps socket out let point same board with other switches of cables of 1.5 sqmm
All as per item No.121.00 mentioned here-in-before but for one 5 amp switch socket combination on independent board with cables of 1.5 sqmm size
All as per item No.121.00 mentioned here-in-before but using 2.5 sq mm size stranded copper conductor cable for one 16 amp switch socket outlet on independent board including 2.5 sq mm FRLH/S PVC insulated unsheathed stranded copper conductor as earth lead complete all as specified and directed by Engineer-in-Charge.
All as per item No.121.00 mentioned here-in-before but using 4 sq mm size stranded copper conductor cable for one 16 amp switch socket outlet on independent board or for AC Starter including 4 sq mm FRLH/S PVC insulated unsheathed stranded copper conductor as earth lead complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of PVC conduit 20 mm dia medium duty in existing wiring with accessories like MS tee, bend, elbow of high quality material size 12-20mm of 2m length complete all as directed.
S&F in replacement of PVC casing caping in existing wiring alongwith accessories like MS tee, bend, elbow of high quality material size 12-20mm of 2m length complete all as directed.
Supply and fix in repairs accessories like wooden gutka,clip 0.5-2.0 inch screw complete all as specified and directed.
S&F lamp holder insulated body with back plate for batten fittings complete all as directed.
S&F in repair lamp holder insulated body with back plate for batten fittings complete all as directed.
S & F switch piano flush type 5/6 Amps 230V AC one way complete all as specified and directed by Engineer-in-Charge.
S & F in repair switch piano flush type 5/6 Amps 230V AC one way complete all as specified and directed by Engineer-in-Charge.
S&F socket outlet 3 pin 5/6 Amps 230 volts flush type. complete all as specified and directed by Engineer-in-Charge.
S&F in repair socket outlet 3 pin 5/6 Amps 230 volts flush type complete all as specified and directed by Engineer-in-Charge.
S&F bell push flush type 5 Amps 230V complete all as specified and directed by Engineer-in-Charge.
S&F call bell, ding dong AC 230 volt single pole (ding dong type) complete all as specified and directed by Engineer-in-Charge.
S&F in repair call bell, ding dong AC 230 volt single pole (ding dong type) complete all as specified and directed by Engineer-in-Charge.
S&F ceiling rose surface bakelite 65x50mm single phase complete all as specified and directed by Engineer-in-Charge.
S&F in repair ceiling rose surface bakelite 65x50mm single phase complete all as specified and directed by Engineer-in-Charge.
S&F switch socket combination 2in 1 3 pin 6 Amps 230 volts flush type complete all as specified and directed by Engineer-in-Charge.
S&F in repair switch socket combination 2in 1 3 pin 6 Amps 230 volts flush type complete all as specified and directed by Engineer-in-Charge.
S&F switch socket combination multipurpose 3 pin 10 and 20 Amps one switch complete all as specified and directed by Engineer-in-Charge.
S&F in repair switch socket combination multipurpose 3 pin 10 and 20 Amps one switch complete all as specified and directed by Engineer-in-Charge.
S&F ceiling fan regulator electronic Step type, solid state, 240 volts, complete all as specified and as directed
S&F in repair ceiling fan regulator electronic Step type, solid state, 240 volts, complete all as specified and as directed
S&F in repair ceiling fan regulator socket type, solid state, 240 volts, complete all as specified and as directed
S&F switch socket combination with box 3 pin 5/6 Amps 230 volts flush type complete all as specified and directed by Engineer-in-Charge.
S&F switch socket combination with box 2in 1 3 pin 10/20 Amps 230 volts flush type complete all as specified and directed by Engineer-in-Charge.
Fixing only swathes, switch socket combination, ceiling rose, call bell and lamp holder of any capacity complete all as specified. Note:- Serviceable swathes, switch socket combination, ceiling rose, call bell and lamp holder shall be obtained from taking down item mentioned here-in-before.
S & F switch piano modular flush type 5/6 Amps 230V AC one way complete all as specified and directed by Engineer-in-Charge.
S & F in repair switch piano modular flush type 5/6 Amps 230V AC way complete all as specified and directed by Engineer-in-Charge.
S & F in repair switch piano modular flush type 6/10 Amps 230V AC two way complete all as specified and directed by Engineer-in-Charge.
S&F modular socket outlet 3 pin 5/6 Amps 230 volts 1 module flush type. complete all as specified and directed by Engineer-in-Charge.
S&F in repair modular socket outlet 3 pin 5/6 Amps 230 volts 1 module flush type complete all as specified and directed by Engineer-in-Charge.
S & F switch piano modular flush type 16 Amps 230V AC complete one way 1 module complete all as specified and directed by Engineer-in-Charge.
S & F in repair switch piano modular flush type 16 Amps 230V AC complete one way 1 module complete all as specified and directed by Engineer-in-Charge.
S&F modular bell push flush type 5 Amps 1 module complete all as specified and directed by Engineer-in-Charge.
S&F in repair modular bell push flush type 5 Amps 1 module complete all as specified and directed by Engineer-in-Charge.
Fixing only modular one/ two way switches, socket outlet and bell push of 1 module and of any capacity complete all as specified. Note:- Serviceable switches and socket outlet shall be obtained from taking down item mentioned here-in-before.
S&F modular switch socket outlet multipurpose 3 pin 6/16 Amps 2 module complete all as specified and directed by Engineer-in-Charge.
S&F in repair modular switch socket outlet multipurpose 3 pin 6/16 Amps 2 module complete all as specified and directed by Engineer-in-Charge.
S& F modular electronic step type fan regulator by step type 230 volt 2 module complete all as specified and directed by Engineer-in-Charge.
S& F in repair modular electronic step type fan regulator by step type 230 volt 2 module complete all as specified and directed by Engineer-in-Charge.
Fixing only modular switch, socket outlet and fan regulator of 2 module and of any capacity complete all as specified. Note:- Serviceable switch socket outlet and fan regulator shall be obtained from taking down item mentioned here-in-before.
Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge.
S & F LED bulb 9Watts 240V 50Hz 6500K b22 base in bulb holder complete all as specified and directed by Engineer-in-Charge.
S&F building security light pressure die cast housing with individual LEDs with modular secondary optics security light luminaries 35 watt LED with 50mm dia light grade GI pipe bent to shape of 45'' 1.5 mtr long and nuts bolts including fixing arrangement after taking down old unserviceable one complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED 2X2 ceiling light with superior efficacy of 120lm/W, AC 120-300V, 50Hz CRI 80+ CCT 6500 30W to be fixed in ceiling light including fixing arrangement after taking down old unserviceable one complete all as specified and directed by Engineer-in-Charge.
S&F "KLASS" series 9W Recessed mounted adjustable downlight for accent lighting white powder coated recessed mounted fixture Pressure die cast aluminum housing with highly efficient reflector and making hole as per size of light including fixing arrangement after taking down old unserviceable one complete all as specified and directed by Engineer-in-Charge.
Supply and fix plug top 3 pin16A 240V Easy to carry, Non flammable & Durable Heavy duty , nickel plated brass terminals Long lasting polycarbonate plastic material complete all as specified and directed by Engineer-in-Charge.
S&F plug and socket in sheet metal enclosures with two pin and earth plug and socket complete with and including MCB SP 20 Amps 240 volts heavy duty all as including taking down of old unsv one specified and as directed by Engr-in-charge
S&F A C starter unit consisting of one 25 Amp capacity starter, one 240 V 25 Amps 10 KA SPN MCB, one 25 Amps socket and one 25 Amps plug top prewire complete all as specified and directed by Engineer-in-Charge.
S&F in repair A C starter unit consisting of one 25 Amp capacity starter, one 240 V 25 Amps 10 KA SPN MCB, one 25 Amps socket and one 25 Amps plug top prewire complete all as specified and directed by Engineer-in-Charge.
S&F sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls complete for 2 modules including taking down of old unsv one complete all as specified and directed by Engineer-in-Charge.
All as per item No.175.00 mentioned here-in-before but for 3 modules
All as per item No.175.00 mentioned here-in-before but for 4 modules
All as per item No.175.00 mentioned here-in-before but for 6 modules
All as per item No.175.00 mentioned here-in-before but for 8 modules
S&F modular cover plate with frame for fixing of modular switches/sockets complete for 2 modules complete all as specified and directed by Engineer-in-Charge.
All as per item No.180.00 mentioned here-in-before but for 3 modules
All as per item No.180.00 mentioned here-in-before but for 4 modules
All as per item No.180.00 mentioned here-in-before but for 6 modules
All as per item No.180.00 mentioned here-in-before but for 8 modules
Taking down unserviceable rusted / damaged MCB DBs of any type and way along with any type MCB and keeping serviceable MCB in safe custody in re-use in the work and making good to the disturbed surfaces of walls etc. complete all as specified and as directed.
S&F MCB TPN DB made up with sheet metal, phosphoresced, power coated, neutral link, earth bar and din rail, 4 way TPN with 200 amps rated bus bar, 415 volts complete all as specified and as directed.
S&F sheet metal enclosure for DB's when MCBs to be used 8 way single pole and neutral double door with 200 amps rated bus bar complete including connection all as specified.
S&F isolator 63 Amps 415 Volts FP with rapturing capacity 10KA including taking down of old one complete all as specified and directed by Engineer-in-Charge.
S&F MCB 6 to 32 amps 240 volts 10KA single pole complete all as specified.
Fixing only MCB 6 to 32 amps 240 volts 10KA single pole complete all as specified. Note:- Serviceable MCBs shall be obtained from taking down item mentioned here-in-before.
S&F in repair MCB 6 to 32 amps 240 volts 10KA single pole complete all as specified.
S&F MCB DP 40 to 63 amps 240 volts 10KA breaking capacity complete all as specified.
Fixing only MCB DP 40 to 63 amps 240 volts 10KA breaking capacity complete all as specified. Note:- Serviceable MCBs shall be obtained from taking down item mentioned here-in-before.
S&F in repair MCB DP 40 to 63 amps 240 volts 10KA breaking capacity complete all as specified and directed by Engineer-in-Charge.
S&F sub main wiring two run of single core PVC insulated unsheathed stranded copper conductor of size 10 sqmm & one run of PVC insulated unsheathed stranded copper conductor of size 10 sqm as earth lead drawing into rigid non metallic PVC conduit of size 20mm dia including taking down old unsv complete all as specified. Note: Two run of 10 sqmm cable and one run of 10 sqmm cable will be measured as single length.
S&F sub main wiring two run of single core PVC insulated unsheathed stranded copper conductor of size 6 sqmm & one run of PVC insulated unsheathed stranded copper conductor of size 6 sqm as earth lead drawing into rigid non metallic PVC conduit of size 20mm dia including taking down old unsv complete all as specified. Note: Two run of 6 sqmm cable and one run of 6 sqmm cable will be measured as single length.
S&F sub main wiring two run of single core PVC insulated unsheathed stranded copper conductor of size 4 sqmm & one run of PVC insulated unsheathed stranded copper conductor of size 4 sqm as earth lead drawing into rigid non metallic PVC conduit of size 20mm dia including taking down old unsv complete all as specified. Note: Two run of 4 sqmm cable and one run of 4 sqmm cable will be measured as single length.
Taking down and opening out the ceiling fan/wall mounted upto1200/1400 mm sweep for inspection, removing bush / bearing, cleaning of bush / bearing, replacement of unserviceable / worn out bearing / bush, shaft, removing burnt out coils from the slots, cleaning and repairing of slots complete including materials like split pin, rubber reel etc and reassembling and refixing of fan complete with and including minor Spares, if any required complete all as specified and as directed. Note : Spare parts shall be measured & paid separately.
Rewinding of ceiling fan motor with super enameled copper winding wire of suitable size & varnishing including testing of fan after rewinding complete all as specified.
Supply only ball bearing suitable for 1200/1400mm sweep Ceiling fan of any make.
Supply only capacitor of 2.5 mfd for Ceiling Fan
Supply only gun metal bush of suitable size for ceiling fan of sweep 1200mm/1400mm as per existing one complete.
Supply only shafts for ceiling fan suitable for 1200mm sweep
Supply only PVC connector for Ceiling Fan
Supply only fan blades for Ceiling fan suitable for 1200mm sweep/1400mm sweep.
Supply only nuts, bolts, for Ceiling fan
M&L for painting of ceiling fan/wall fan/exhaust fan of any size and sweep complete with synthetic enamel paint by spraying including filling with cavities with filler, after cleaning all dust etc complete all as specified and directed by Engineer-in-Charge.
Taking out the BLDC Ceiling fan/ wireless remote PCBA (controller bd) and repair the same and refixing the same in original position either in fan or remote complete all as specified and directed by Engineer-in-Charge.
Supply only BLDC PCBA (controller Bd)
Supply only BLDC Ceiling Fan Stator Ferrite Magnet Ring 12/14/16 Poles
Supply only BLDC rotor magnetic coil of 12/14/16 poles
Supply only plastic 12 pole stamping ring
Supply only remotes for BLDC ceiling fan. Make as per sample
Taking down unserviceable ceiling fans and supplying and fixing new ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete with all the connection as directed. Note:- Old Unserviceable fan shall be deposited to store.
Taking down unserviceable wall fans and supply and fixing wall fans 400mm sweep power input 60Watts min speed 1350RPM min air delivery 85 CMM 240V 50Hz complete with electrical connection complete all as specified and directed by Engineer-in-Charge. Note:- Old Unserviceable fan shall be deposited to store.
Taking down and opening out the exhaust fan up to 400 mm sweep for inspection, removing bush / bearing, cleaning of bush / bearing, replacement of unserviceable / worn out bearing / bush, shaft, removing burnt out coils from the slots, cleaning and repairing of slots rubber reel etc. reassembling and refixing of fan complete including all as specified and as directed.
Rewinding of fan motor with super enameled copper winding wire of suitable size & varnishing including testing of fan after rewinding complete all as specified.
M&L for painting of exhaust fan of any size and sweep complete, in situ with approved colour synthetic enamel paint by spraying including filling with cavities with filler, one coat after cleaning all dust etc.
Supply only bush suitable for exhaust fan.
Supply only ball bearing suitable for exhaust fan.
Supply only capacitor 2.5 mfd for exhaust fan.
Taking down unserviceable exhaust fans and supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete as directed. Note:- Old Unserviceable fan shall be deposited to store.
Taking down unserviceable exhaust fans and supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm complete as directed. Note:- Old Unserviceable fan shall be deposited to store.
S&F in replacement louvers of exhaust fan up to the size of 400mm sweep up to four storey building complete including arrangement of scaffolding for fixing of louvers with all nuts, bolts and washers and finished properly with cement work as per existing complete all as specified and as directed by engr in charge
Taking down carefully unserviceable geyser of any type and make from site after disconnections of water & electrical connections & carrying out to MES store yard for inspection and thereafter to workshop for repair & replacement of components such as heating element, thermostat, cable, neon lamp, plug top, outer casing, plates & repair work to apparatus plate, copper tank, split plate including de-scaling of water tank etc and carrying back to MES store yard for testing and refixing at site and making water & electrical connection on completion and all as directed.
M&L for painting of geysers 25 ltrs at site/at workshop duly with one coat of synthetic enamel paint (white) including preparation of surfaces with brush, cleaning agents as required of 25 Ltr capacity and its front with best quality paint all as directed and specified by Engr-in-Charge
M&L for brazing/gas welding of inner container copper of 25 ltrs /50 ltrs capacity and any make and making leak proof all as directed.
Supply only following spares for geysers:- Heating element 1.5KW including rubber gasket ISI marked suitable for existing geysers.
Heating element 2.00KW including rubber gasket ISI marked suitable for existing geysers.
Thermostat for suitable existing geyser of 25/50 litrs capacity
Chromium plated copper pipe of length not less than 60cm including washers for incoming & outgoing hot & cold water connections as specified and directed by Engr-in-charge
Apparatus plate assembly complete for geyser of capacity 25/50 litrs capacity.
Outer casing made out of 22 SWG MS sheet suitable for geyser of capacity 25 litrs.
Storage tank fabricated from copper sheet gauge suitable for geyser of capacity 25 ltrs of make as specified and approved.
Split plate bottom cover made out of 22 SWG MS sheet suitable for 25 litrs capacity geyser
Split plate top cover made out of 22 SWG MS sheet suitable for 25 litrs capacity geyser
Insulating material glass wool
Element holding brass stud
Element holding MS clamp
Fusible metal plug
Neon lamp round/square with connection lead
Non return valve for geyser inlet
Brass Pressure Reducing valve suitable for geyser 25 liter as per site requirement.
Supply & fix in repairs 1.5 Sqmm FRLSH Copper conductor coil in existing concealed conduit 1100 volts grade complete all as specified and directed.
Supply & fix in repairs 2.5 Sqmm FRLSH Copper conductor in existing concealed conduit 1100 volts grade all as specified and directed.
M&L for earthling complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.00 mm thick burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strip 4 mm as earthling lead by means of bolts, nuts, check nuts and washers of GI or steel, GI strip projected by 15 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 cm c/c both ways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I complete all as specified and directed.
Supply and fix in repair electronic meters temper proof LCD display with polycarbonate cover 230 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete as directed.
Supply and fixing repair electronic meters temper proof LCD display with polycarbonate cover 230 V, 10- 60Amp, 3 Phase, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete as directed.
Supply and fix in repairs /replacement of self adhesive PVC Electrical Insulation tape of size 1.8cmx6.5mx0.125mm mix colour box in a packet of 12 roll complete all as specified and directed. Note- Insulation tape should be ISI marked.
Taking down unserviceable electric water heater and supply and fix electric water heater, storage type steel body with copper inner tank and heating element up to 2 KW capacity 25 liter, BEE 5 Star rated complete with pressure reducing valve and all accessories such as safety valve, thermostat, NRV, connection piece etc. complete as directed. Note:- Old Geyser shall be deposited to store.
DIPAK ENTERPRISE (BID ID -3429615)
DILIP CONSTRUCTION (BID ID -3424413)
AUTO ELECTRICALS (BID ID -3423048)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .