Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.2 LAccepted-AOC | ₹36.2 L Quoted ₹37.0 L | L1 | Accepted-AOC REASONABLE |
| 2 | L2₹41.2 L+₹4.2 L (11.4%)Rejected-Finance | ₹41.2 L+₹4.2 L (11.4%) | L2 | Rejected-Finance HIGH RATE |
| 3 | L3₹41.9 L+₹4.9 L (13.3%)Rejected-Finance | ₹41.9 L+₹4.9 L (13.3%) | L3 | Rejected-Finance HIGH RATE |
| 4 | L4₹43.4 L+₹6.4 L (17.4%)Rejected-Finance 1 NEAR AKBARIYA MASJID WIMBERLYGUNJ SOUTH ANDAMAN ANDAMAN NICOBAR 744206 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744206 | ₹43.4 L+₹6.4 L (17.4%) | L4 | Rejected-Finance HIGH RATE |
| 5 | L5₹44.7 L+₹7.8 L (21.0%)Rejected-Finance FLAT NO B 205 S NO 296 2 DIVINE HOMES PORWAL ROAD LOHEGAON PUNE 411047 | PUNE | MAHARASHTRA | 411047 | ₹44.7 L+₹7.8 L (21.0%) | L5 | Rejected-Finance HIGH RATE |
| Sl No | Description | Qty | Unit | Sneha Aircool L6 | M/S JEELANI ELECTRICALS L2 | BSK Construction L5 | M/s PIONEER CONTRACTORS L7 | Azurite Engineering L3 | SBS Enterprises L4 | M/S VEDHANT ASSOCIATES L8 | Shriyansh sales and services L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and install cubical indoor type double door with front & back opening, weather proof IP-45 AMF Control panel fabricated out of 2.0 mm thick CRCA with RAL 7032 powder coating MS sheet for outer panel and 1.6 mm MS sheet for internal compartments, powder coated incorporating the following items including control wiring mounted on angle iron frame made out of 65 mmx65mm angle iron and grouted on PCC incl necessary excavation all as specified and directed. . AMF DG CONTROL PANEL(62.5 KVA) 415 V /440V,50Hz,3 Phase,4 wire AC system floor mounted (a) Power contactor 4Pole,125 A AC-1 Duty Coil Voltage 240VAC,2NO+2NC aux contacts=2nos (b) HRC Fuse fittings with 125A HRC fuse /links=06 Nos (c) Electronic energy meter 5-60A,2x240V AC 3 phase,4wire=01 No (d) Current Transformer CTR 125/5,ACC-CL-1,5a=03 nos (e) Electronic Hooter 12 V DC 96sqmm flush mounting (to be mounted in on accoustic) (f) Aux relay 12V DC with LED ,free wheeling diode,4 C/O contacts at 5A=02 Nos (g) Aux relay 24V DC with LED ,free wheeling diode,4 C/O contacts at 5A=04Nos (h) Aux relay 12V DC with LED ,free wheeling diode,2 C/O contacts at 5A rating DIN rail mounting and plug in base module type=01Nos (j) Aux contactor 240VAC with suitable no NO and NC contacts=01 No (k) LED indicating lamps 240VAC=02 Nos (l) LED indicating lamps 24VDC=02 Nos (m) Push buttons with Elements=07 nos
(n) Stay put type push buttons with elements=01 No (o) Selector switch 6pole 2 way,10 A =01 No (p ) MCBSP 6A,6/10KA=08 Nos (q) Glass fuse fitting 2A glass fuse links draw out type=6 nos (r) Glass fuse fitting 2A glass fuse links draw out type( to be fitted in panel)=01 nos (s) Neutral link 10 A (disconnectable type) =06 Nos (t) MCCB 125A,4Pole,25KA=02 nos with spreader links and extended rotary handles (u) AMF controller suitable for 62.5 KVA DG set (v) Multi function meter =02 Nos (w) Control contactor =4 Nos (x) Battery Charger =01 No (y) LED RYB phase indicators = 01Set (z) LED ON & OFF indicators =01 Set (aa) MCB 10A 4 Pole =02 Nos (ab) MCB 6A 2 Pole=01 No | 1 | Each | 1,50,000 ₹1,50,000 | 1,31,097 ₹1,31,097 | 2,50,000 ₹2,50,000 | 1,80,000 ₹1,80,000 | 1,44,500 ₹1,44,500 | 1,12,000 ₹1,12,000 | 1,80,000 ₹1,80,000 | 95,000 ₹95,000 Lowest |
| 2.00 | Supply and install cubical outdoor type, double door with front & back opening, weather proof IP-65 AMF Control panel fabricated out of 3.0 mm thick CRCA with RAL 7032 powder coating MS sheet for outer panel and 1.6 mm MS sheet for internal compartments, powder coated incorporating the following items including control wiring . AMF DG CONTROL PANEL(82.5 KVA) 415 V /440V,50Hz,3 Phase,4 wire AC system mounted on angle iron frame and grouted on PCC incl necessary excavation all as specified and directed. (a) Power contactor 4Pole,125 A AC-1 Duty Coil Voltage 240VAC,2NO+2NC aux contacts=2nos (b) HRC Fuse fittings with 125 A HRC fuse /links=06 Nos (c) Electronic energy meter 5-60A,2x240V AC 3 phase,4wire=01 No (d) Current Transformer CTR 125/5,ACC-CL-1,5a=03 nos (e) Electronic Hooter 12 V DC 96sqmm flush mounting (to be mounted in on accoustic) (f) Aux relay 12V DC with LED ,free wheeling diode,4 C/O contacts at 5A=02 Nos(g)Aux relay 24V DC with LED ,free wheeling diode,4 C/O contacts at 5A=04Nos (h) Aux relay 12V DC with LED ,free wheeling diode,2 C/O contacts at 5A rating DIN rail mounting and plug in base module type=01Nos (j) Aux contactor 240VAC with suitable no NO and NC contacts=01 No (k) LED indicating lamps 240VAC=02 Nos (l) LED indicating lamps 24VDC=02 Nos (m) Push buttons with Elements=07 nos
(n) Stay put type push buttons with elements=01 No (o) Selector switch 6pole 2 way,10 A =01 No (p) MCBSP 6A,6/10KA=08 Nos (q) Glass fuse fitting 2A glass fuse links draw out type=6 nos (r) Glass fuse fitting 2A glass fuse links draw out type( to be fitted in panel)=01 nos (s) Neutral link 10 A(disconnectable type)=06 Nos (t) MCCB 125A,4Pole,25 KA=02 nos with spreader links and extended rotary handles (u) AMF controller suitable for 82.5 KVA DG set (v) Multi function meter =02 Nos (w) Control contactor =4 Nos (x) Battery Charger =01 No (y) LED RYB phase indicators = 01Set (z) LED ON & OFF indicators =01 Set (aa) MCB 10A 4 Pole =02 Nos (ab) MCB 6A 2 Pole=01 No complete all as specified and as directed. | 1 | Each | 1,76,000 ₹1,76,000 | 1,58,497 ₹1,58,497 | 3,00,000 ₹3,00,000 | 2,00,070 ₹2,00,070 | 1,87,000 ₹1,87,000 | 1,45,000 ₹1,45,000 | 1,95,000 ₹1,95,000 | 99,000 ₹99,000 Lowest |
| 3.00 | Supply and install cubical outdoor type double door with front & back opening, weather proof IP-65 AMF Control panel fabricated out of 3.0 mm thick CRCA with RAL 7032 powder coatingMS sheet for outer panel and 1.6 mm MS sheet for internal compartments, powder coated incorporating the following items including control wiring . AMF DG CONTROL PANEL 200 KVA) 415 V /440V,50Hz,3 Phase,4 wire AC system mounted on angle iron frame and grouted on PCC incl necessary excavation all as specified and directed.(a) Power contactor 4Pole,300 A AC-1 Duty Coil Voltage 240VAC,2NO+2NC aux contacts=2nos (b) HRC Fuse fittings with 300A HRC fuse /links=06 Nos (c) Electronic energy meter 5-60A,2x240V AC 3 phase,4wire=01 No (d) Current Transformer CTR 300/5,ACC-CL-1,5a=03 nos (e) Electronic Hooter 12 V DC 96sqmm flush mounting (to be mounted in on accoustic) (f) Aux relay 12V DC with LED ,free wheeling diode,4 C/O contacts at 5A=02 Nos (g) Aux relay 24V DC with LED ,free wheeling diode,4 C/O contacts at 5A=04Nos (h) Aux relay 12V DC with LED ,free wheeling diode,2 C/O contacts at 5A rating DIN rail mounting and plug in base module type=01Nos (j) Aux contactor 240VAC with suitable no NO and NC contacts=01 No (k) LED indicating lamps 240VAC=02 Nos (l) LED indicating lamps 24VDC=02 Nos (m) Push buttons with Elements=07 nos (n) Stay put type push buttons with elements=01 No (o) Selector switch 6pole 2 way,10 A =01 No (p) MCBSP 6A,6/10KA=08 Nos (q) Glass fuse fitting 2A glass fuse links draw out type=6 nos (r) Glass fuse fitting 2A glass fuse links draw out type( to be fitted in panel)=01 nos (s) Neutral link 10 A(disconnectable type)=06 Nos (t) MCCB 320A,4Pole,36KA=02 nos with spreader links and extended rotary handles (u) AMF controller suitable for 200 KVA DG set (v) Multi function meter =02 Nos (w) Control contactor =4 Nos (x) Battery Charger =01 No (y) LED RYB phase indicators = 01Set (z) LED ON & OFF indicators =01 Set (aa) MCB 10A 4 Pole =02 Nos (ab) MCB 6A 2 Pole=01 No complete all as specified and as directed. | 1 | Each | 3,04,000 ₹3,04,000 | 2,78,019 ₹2,78,019 | 3,50,000 ₹3,50,000 | 3,78,000 ₹3,78,000 | 3,74,000 ₹3,74,000 | 3,45,000 ₹3,45,000 | 3,75,000 ₹3,75,000 | 1,40,000 ₹1,40,000 Lowest |
| 4.00 | Supply and install cubical outdoor type double door with front & back opening, weather type, weather proof IP-65 AMF Control panel fabricated out of 3.0 mm thick CRCA MS sheet for outer panel and 1.6 mm MS sheet for internal compartments, powder coated incorporating the following items including control wiring . AMF DG CONTROL PANEL 50 KVA) 415 V /440V,50Hz,3 Phase,4 wire AC system mounted on angle iron frame and grouted on PCC incl necessary excavation all as specified and directed.(a) Power contactor 4Pole,125 A AC-1 Duty Coil Voltage 240VAC,2NO+2NC aux contacts=2nos (b) HRC Fuse fittings with 100A HRC fuse /links=06 Nos (c) Electronic energy meter 5-60A,2x240V AC 3 phase,4wire=01 No (d) Current Transformer CTR 100/5,ACC-CL-1,5a=03 nos (e) Electronic Hooter 12 V DC 96sqmm flush mounting (to be mounted in on accoustic) (f) Aux relay 12V DC with LED ,free wheeling diode,4 C/O contacts at 5A=02 Nos (g) Aux relay 24V DC with LED ,free wheeling diode,4 C/O contacts at 5A=04Nos (h) Aux relay 12V DC with LED ,free wheeling diode,2 C/O contacts at 5A rating DIN rail mounting and plug in base module type=01Nos (j) Aux contactor 240VAC with suitable no NO and NC contacts=01 No (k) LED indicating lamps 240VAC=02 Nos (l) LED indicating lamps 24VDC=02 Nos (m)Push buttons with Elements=07 nos (Continued....) | 1 | Each | 1,51,000 ₹1,51,000 | 1,30,000 ₹1,30,000 | 2,00,000 ₹2,00,000 | 1,70,100 ₹1,70,100 | 1,71,000 ₹1,71,000 | 92,000 ₹92,000 Lowest | 1,65,000 ₹1,65,000 | 94,000 ₹94,000 |
| 4.10(Continued from item No.4.....) (n)Stay put type push buttons with elements=01 No (o) Selector switch 6 pole 2 way,10 A =01 No (p) MCBSP 6A,6/10KA=08 Nos (q) Glass fuse fitting 2A glass fuse links draw out type=6 nos (r) Glass fuse fitting 2A glass fuse links draw out type( to be fitted in panel)=01 nos (s) Neutral link 10 A(disconnectable type)=06 Nos (t) MCCB 100A,4Pole,16KA=02 nos with spreader links and extended rotary handles (u) AMF controller suitable for 50 KVA DG set (v) Multi function meter =02 Nos (w) Control contactor =4 Nos (x) Battery Charger =01 No (y) LED RYB phase indicators = 01Set (z) LED ON & OFF indicators =01 Set (aa) MCB 10A 4 Pole =02 Nos (ab) MCB 6A 2 Pole=01 No complete all as specified and as directed. Note for item No 1 to 4 (i) The panel shall be totally enclosed dust & vermin proof confrming to degree of protection, double door type with locking arrangement front & back sides, comprising of gaskets between adjacent units & beneath all covers shall be provided with neoprene rubber gasket & forced ventilation arrangement on panel fan 100mm sweep & its wiring for heat dissipation from both side of panel. (ii) The panel GA drawing incl dimension & length of Bus bar shall be approved by accepting officer | |||||||||||
| 5.00 | Dismantling of old unsv AMF from any location complete all as specified and as directed. | 5 | Each | 1,800 ₹9,000 | 500 ₹2,500 | 150 ₹750 Lowest | 3,600 ₹18,000 | 3,400 ₹17,000 | 1,600 ₹8,000 | 1,500 ₹7,500 | 2,500 ₹12,500 |
| 6.00 | Taking down old unsv cable of any size complete all as specified and as directed. | 1,240 | RM | 20 ₹24,800 | 25 ₹31,000 | 100 ₹1,24,000 | 9 ₹11,160 Lowest | 85 ₹1,05,400 | 16 ₹19,840 | 15 ₹18,600 | 10 ₹12,400 |
| 7.00 | M& L for XLPE insulated, armoured heavy duty electric cable with copper conductor, 1100 volts grade, cross-sectional area 300 sqmm 3.5Core complete with copper thimbles laid in wall floor and trenches complete all as specified and as directed. | 40 | RM | 23,000 ₹9,20,000 | 19,829 ₹7,93,160 | 4,000 ₹1,60,000 | 2,025 ₹81,000 Lowest | 2,040 ₹81,600 | 14,660 ₹5,86,400 | 25,000 ₹10,00,000 | 17,125 ₹6,85,000 |
| 8.00 | M& L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 300sqmm 3.5 core laid in wall floor and trenches complete all as specified and as directed. | 100 | RM | 2,100 ₹2,10,000 | 2,108 ₹2,10,800 | 2,200 ₹2,20,000 | 2,025 ₹2,02,500 | 3,400 ₹3,40,000 | 1,710 ₹1,71,000 | 2,550 ₹2,55,000 | 1,570 ₹1,57,000 Lowest |
| 9.00 | M& L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 150sqmm 3.5 core laid in wall floor and trenches complete all as specified and as directed. | 100 | RM | 1,100 ₹1,10,000 | 1,054 ₹1,05,400 | 1,200 ₹1,20,000 | 1,035 ₹1,03,500 | 1,870 ₹1,87,000 | 940 ₹94,000 | 1,340 ₹1,34,000 | 810 ₹81,000 Lowest |
Tender Value
₹46.7 L
EMD Value
₹94,000
Closing Date
14 Apr 2026, 6:00 pmClosed
GE Khadakwasla
GE Khadakwasla
SPL REPAIRS TO AMF PANELS OF DG SETS UNDER AGE E/M- I AT NDA KHADAKWASLA
2026_MES_757706_1
8039/E8
Open Tender
Civil Works
Item Rate
180 days
GE Khadakwasla
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE Khadakwasla
₹94,000
Yes
14 Aug 2026
25 Mar 2026
16 Apr 2026
25 Mar 2026
14 Apr 2026
8 Apr 2026
25 Mar 2026 - 8 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply and install cubical indoor type, weather proof IP-45 AMF Control panel fabricated out of 2.0 mm thick CRCA with RAL 7032 powder coating MS sheet for outer panel and 1.6 mm MS sheet for internal compartments, powder coated incorporating the following items including control wiring mounted on angle iron frame made out of 65 mmx65mm angle iron and grouted on PCC incl necessary excavation all as specified and directed. . AMF DG CONTROL PANEL(62.5 KVA) 415 V /440V,50Hz,3 Phase,4 wire AC system floor mounted (a) Power contactor 4Pole,125 A AC-1 Duty Coil Voltage 240VAC,2NO+2NC aux contacts=2nos (b) HRC Fuse fittings with 125A HRC fuse /links=06 Nos (c) Electronic energy meter 5-60A,2x240V AC 3 phase,4wire=01 No (d) Current Transformer CTR 125/5,ACC-CL-1,5a=03 nos (e) Electronic Hooter 12 V DC 96sqmm flush mounting (to be mounted in on accoustic) (f) Aux relay 12V DC with LED ,free wheeling diode,4 C/O contacts at 5A=02 Nos (g) Aux relay 24V DC with LED ,free wheeling diode,4 C/O contacts at 5A=04Nos (h) Aux relay 12V DC with LED ,free wheeling diode,2 C/O contacts at 5A rating DIN rail mounting and plug in base module type=01Nos (j) Aux contactor 240VAC with suitable no NO and NC contacts=01 No (k) LED indicating lamps 240VAC=02 Nos (l) LED indicating lamps 24VDC=02 Nos (m) Push buttons with Elements=07 nos (n) Stay put type push buttons with elements=01 No (o) Selector switch 6pole 2 way,10 A =01 No (p ) MCBSP 6A,6/10KA=08 Nos (q) Glass fuse fitting 2A glass fuse links draw out type=6 nos (r) Glass fuse fitting 2A glass fuse links draw out type( to be fitted in panel)=01 nos (s) Neutral link 10 A (disconnectable type) =06 Nos (t) MCCB 125A,4Pole,25KA=02 nos with spreader links and extended rotary handles (u) AMF controller suitable for 62.5 KVA DG set (v) Multi function meter =02 Nos (w) Control contactor =4 Nos (x) Battery Charger =01 No (y) LED RYB phase indicators = 01Set (z) LED ON & OFF indicators =01 Set (aa) MCB 10A 4 Pole =02 Nos (ab) MCB 6A 2 Pole=01 No | |||||
| 2Supply and install cubical outdoor type, , weather proof IP-65 AMF Control panel fabricated out of 3.0 mm thick CRCA with RAL 7032 powder coating MS sheet for outer panel and 1.6 mm MS sheet for internal compartments, powder coated incorporating the following items including control wiring . AMF DG CONTROL PANEL(82.5 KVA) 415 V /440V,50Hz,3 Phase,4 wire AC system mounted on angle iron frame and grouted on PCC incl necessary excavation all as specified and directed. (a) Power contactor 4Pole,125 A AC-1 Duty Coil Voltage 240VAC,2NO+2NC aux contacts=2nos (b) HRC Fuse fittings with 125 A HRC fuse /links=06 Nos (c) Electronic energy meter 5-60A,2x240V AC 3 phase,4wire=01 No (d) Current Transformer CTR 125/5,ACC-CL-1,5a=03 nos (e) Electronic Hooter 12 V DC 96sqmm flush mounting (to be mounted in on accoustic) (f) Aux relay 12V DC with LED ,free wheeling diode,4 C/O contacts at 5A=02 Nos(g)Aux relay 24V DC with LED ,free wheeling diode,4 C/O contacts at 5A=04Nos (h) Aux relay 12V DC with LED ,free wheeling diode,2 C/O contacts at 5A rating DIN rail mounting and plug in base module type=01Nos (j) Aux contactor 240VAC with suitable no NO and NC contacts=01 No (k) LED indicating lamps 240VAC=02 Nos (l) LED indicating lamps 24VDC=02 Nos (m) Push buttons with Elements=07 nos (n) Stay put type push buttons with elements=01 No (o) Selector switch 6pole 2 way,10 A =01 No (p) MCBSP 6A,6/10KA=08 Nos (q) Glass fuse fitting 2A glass fuse links draw out type=6 nos (r) Glass fuse fitting 2A glass fuse links draw out type( to be fitted in panel)=01 nos (s) Neutral link 10 A(disconnectable type)=06 Nos (t) MCCB 125A,4Pole,25 KA=02 nos with spreader links and extended rotary handles (u) AMF controller suitable for 82.5 KVA DG set (v) Multi function meter =02 Nos (w) Control contactor =4 Nos (x) Battery Charger =01 No (y) LED RYB phase indicators = 01Set (z) LED ON & OFF indicators =01 Set (aa) MCB 10A 4 Pole =02 Nos (ab) MCB 6A 2 Pole=01 No complete all as specified and as directed. | |||||
| 3Supply and install cubical outdoor type, weather proof IP-65 AMF Control panel fabricated out of 3.0 mm thick CRCA with RAL 7032 powder coatingMS sheet for outer panel and 1.6 mm MS sheet for internal compartments, powder coated incorporating the following items including control wiring . AMF DG CONTROL PANEL 200 KVA) 415 V /440V,50Hz,3 Phase,4 wire AC system mounted on angle iron frame and grouted on PCC incl necessary excavation all as specified and directed.(a) Power contactor 4Pole,300 A AC-1 Duty Coil Voltage 240VAC,2NO+2NC aux contacts=2nos (b) HRC Fuse fittings with 300A HRC fuse /links=06 Nos (c) Electronic energy meter 5-60A,2x240V AC 3 phase,4wire=01 No (d) Current Transformer CTR 300/5,ACC-CL-1,5a=03 nos (e) Electronic Hooter 12 V DC 96sqmm flush mounting (to be mounted in on accoustic) (f) Aux relay 12V DC with LED ,free wheeling diode,4 C/O contacts at 5A=02 Nos (g) Aux relay 24V DC with LED ,free wheeling diode,4 C/O contacts at 5A=04Nos (h) Aux relay 12V DC with LED ,free wheeling diode,2 C/O contacts at 5A rating DIN rail mounting and plug in base module type=01Nos (j) Aux contactor 240VAC with suitable no NO and NC contacts=01 No (k) LED indicating lamps 240VAC=02 Nos (l) LED indicating lamps 24VDC=02 Nos (m) Push buttons with Elements=07 nos (n) Stay put type push buttons with elements=01 No (o) Selector switch 6pole 2 way,10 A =01 No (p) MCBSP 6A,6/10KA=08 Nos (q) Glass fuse fitting 2A glass fuse links draw out type=6 nos (r) Glass fuse fitting 2A glass fuse links draw out type( to be fitted in panel)=01 nos (s) Neutral link 10 A(disconnectable type)=06 Nos (t) MCCB 320A,4Pole,36KA=02 nos with spreader links and extended rotary handles (u) AMF controller suitable for 200 KVA DG set (v) Multi function meter =02 Nos (w) Control contactor =4 Nos (x) Battery Charger =01 No (y) LED RYB phase indicators = 01Set (z) LED ON & OFF indicators =01 Set (aa) MCB 10A 4 Pole =02 Nos (ab) MCB 6A 2 Pole=01 No complete all as specified and as directed. | |||||
| 4Supply and install cubical outdoor type, weather type, weather proof IP-65 AMF Control panel fabricated out of 3.0 mm thick CRCA MS sheet for outer panel and 1.6 mm MS sheet for internal compartments, powder coated incorporating the following items including control wiring . AMF DG CONTROL PANEL 50 KVA) 415 V /440V,50Hz,3 Phase,4 wire AC system mounted on angle iron frame and grouted on PCC incl necessary excavation all as specified and directed.(a) Power contactor 4Pole,125 A AC-1 Duty Coil Voltage 240VAC,2NO+2NC aux contacts=2nos (b) HRC Fuse fittings with 100A HRC fuse /links=06 Nos (c) Electronic energy meter 5-60A,2x240V AC 3 phase,4wire=01 No (d) Current Transformer CTR 100/5,ACC-CL-1,5a=03 nos (e) Electronic Hooter 12 V DC 96sqmm flush mounting (to be mounted in on accoustic) (f) Aux relay 12V DC with LED ,free wheeling diode,4 C/O contacts at 5A=02 Nos (g) Aux relay 24V DC with LED ,free wheeling diode,4 C/O contacts at 5A=04Nos (h) Aux relay 12V DC with LED ,free wheeling diode,2 C/O contacts at 5A rating DIN rail mounting and plug in base module type=01Nos (j) Aux contactor 240VAC with suitable no NO and NC contacts=01 No (k) LED indicating lamps 240VAC=02 Nos (l) LED indicating lamps 24VDC=02 Nos (m)Push buttons with Elements=07 nos (n)Stay put type push buttons with elements=01 No (o) Selector switch 6 pole 2 way,10 A =01 No (p) MCBSP 6A,6/10KA=08 Nos (q) Glass fuse fitting 2A glass fuse links draw out type=6 nos (r) Glass fuse fitting 2A glass fuse links draw out type( to be fitted in panel)=01 nos (s) Neutral link 10 A(disconnectable type)=06 Nos (t) MCCB 100A,4Pole,16KA=02 nos with spreader links and extended rotary handles (u) AMF controller suitable for 50 KVA DG set (v) Multi function meter =02 Nos (w) Control contactor =4 Nos (x) Battery Charger =01 No (y) LED RYB phase indicators = 01Set (z) LED ON & OFF indicators =01 Set (aa) MCB 10A 4 Pole =02 Nos (ab) MCB 6A 2 Pole=01 No complete all as specified and as directed. | |||||
| 5Dismantling of old unsv AMF from any location complete all as specified and as directed. | |||||
| 6Taking down old unsv cable of any size complete all as specified and as directed. | |||||
| 7M& L for XLPE insulated, armoured heavy duty electric cable with copper conductor, 1100 volts grade, cross-sectional area 300 sqmm 3.5Core complete with copper thimbles laid in wall floor and trenches complete all as specified and as directed. | |||||
| 8M& L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 300sqmm 3.5 core laid in wall floor and trenches complete all as specified and as directed. | |||||
| 9M& L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 150sqmm 3.5 core laid in wall floor and trenches complete all as specified and as directed. | |||||
| 10M& L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sqmm 3.5Core laid in wall floor and trenches complete all as specified and as directed. | |||||
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.51 MB
8039.pdf
Tender Documents • 1.02 MB
BOQ_848738.xls
BOQ • 3.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .