Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAdmitted-Finance 561 K L KYDGANJ ALLAHABAD UTTAR PRADESH 211003 | ALLAHABAD | ALLAHABAD | UTTAR PRADESH | 211003 | L1 | Admitted-Finance | |
| 2 | L2₹1.2 Cr+₹14.5 L (13.8%)Admitted-Finance 107 265 BRAHAMA NAGAR KANPUR UP 208012 | KANPUR NAGAR | UTTAR PRADESH | 208012 | L2 | Admitted-Finance | |
| 3 | L3₹1.2 Cr+₹18.2 L (17.2%)Admitted-Finance B 18 SECTOR 6 NEAR HUDCO COLONY HANUMANGARH RAJASTHAN | HANUMANGARH | RAJASTHAN | 335062 | L3 | Admitted-Finance | |
| 4 | L4₹1.3 Cr+₹26.8 L (25.4%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | L5₹1.5 Cr+₹40.7 L (38.6%)Admitted-Finance 1 B 4A 3A 3RD FLOOR ADHCINI SOUTH DELHI ADCINI SOUTH DELHI DELHI 110017 | SOUTH DELHI | DELHI | 110017 | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | TARUN ELECTRICALS L3 | Instapower Ltd L5 | Awasthi Electric Works L2 | M/S B. PRASAD & COMPANY L4 | B L ENTERPRISES L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply of 36 W(+/-10%) linear type LED luminaire (4 ft) suitable for mounting on false ceiling, made of extruded aluminum housing complying construction requirements as per IS:10322 with Driver efficiency>85%,internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, IK02, CRI ≥80, UGR(Unified Glare Rating)<19, Flicker free, (flicker should be below 5 %),life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K /5700°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching)<3,Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing (Stickers shall not be acceptable) complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted with technical datasheets for approval from EIC. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management:heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Quote should include preparation & submission of lighting design , illumination calculations using industry-standard lighting design software, preparation of photometric layouts, lux-level calculations, uniformity calculations, glare assessment, lighting power density (LPD) calculations, reflected ceiling plans (RCP) complete as per instructions of Engineer-In-Charge. | 720 | Each | 3,500 ₹25,20,000 | 3,321 ₹23,91,120 Lowest | 4,000 ₹28,80,000 | 6,900 ₹49,68,000 | 5,500 ₹39,60,000 |
| 2.00 | Supply of 45 W(+/-10%) linear type LED luminaire(8 ft) suitable for mounting on false ceiling, made of extruded aluminum housing complying construction requirements as per IS:10322 with Driver efficiency >85%, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, IK02, CRI ≥80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching)<3,Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing(Stickers shall not be acceptable). complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted with technical datasheets for approval from EIC. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Quote should include preparation & submission of lighting design , illumination calculations using industry-standard lighting design software, preparation of photometric layouts, lux-level calculations, uniformity calculations, glare assessment, lighting power density (LPD) calculations, reflected ceiling plans (RCP) complete as per instructions of Engineer-In-Charge. | 200 | Each | 4,000 ₹8,00,000 Lowest | 6,765 ₹13,53,000 | 7,200 ₹14,40,000 | 8,400 ₹16,80,000 | 7,600 ₹15,20,000 |
| 3.00 | Supply 600mm x 600 mm 36 W(+/-10%) LED recessed mounted panel suitable for mounting on false ceiling, made of extruded aluminum housing complying construction requirements as per IS:10322 with Driver efficiency >85%,internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, IK02, CRI ≥80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching)<3,Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/Screen printing on housing(Stickers shall not be acceptable) complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy≥135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted with technical datasheets for approval from EIC. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Quote should include preparation & submission of lighting design , illumination calculations using industry-standard lighting design software, preparation of photometric layouts, lux-level calculations, uniformity calculations, glare assessment, lighting power density (LPD) calculations, reflected ceiling plans (RCP) complete as per instructions of Engineer-In-Charge. | 250 | Each | 4,000 ₹10,00,000 | 3,321 ₹8,30,250 | 2,450 ₹6,12,500 | 3,400 ₹8,50,000 | 1,900 ₹4,75,000 Lowest |
| 4.00 | Supply of 24 W(+/-10%) deep recessed LED Downlighter fittings suitable for mounting on false ceiling with housing complying construction requirements as per IS:10322 with Driver efficiency >85%, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, IK02, CRI ≥80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching)<3,Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/Screen printing on housing(Stickers shall not be acceptable) complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy≥120 lm/Watt output.LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted with technical datasheets for approval from EIC. Shape size, CCT and Beam Angle shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Quote should include preparation & submission of lighting design , illumination calculations using industry-standard lighting design software, preparation of photometric layouts, lux-level calculations, uniformity calculations, glare assessment, lighting power density (LPD) calculations, reflected ceiling plans (RCP) complete as per instructions of Engineer-In-Charge. | 200 | Each | 3,500 ₹7,00,000 | 1,168.5 ₹2,33,700 Lowest | 1,500 ₹3,00,000 | 1,800 ₹3,60,000 | 1,500 ₹3,00,000 |
| 5.00 | Supply of 80 W(+/-10%) LED Surface mounted LED High Bay Light fittings powder coated pressure die cast aluminium body with separate driver as per the requirement with Driver efficiency>85%,internal surge protection of 5 KV L,N,E as per IEC 61000-4-5,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120 deg, suitable tiltable fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR,PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size,beam angle and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Quote should include preparation & submission of lighting design , illumination calculations using industry-standard lighting design software, preparation of photometric layouts, lux-level calculations, uniformity calculations, glare assessment, lighting power density (LPD) calculations, reflected ceiling plans (RCP) complete as per instructions of Engineer-In-Charge. | 60 | Each | 3,000 ₹1,80,000 | 2,706 ₹1,62,360 Lowest | 3,700 ₹2,22,000 | 12,000 ₹7,20,000 | 4,200 ₹2,52,000 |
| 6.00 | Supply of 120 W (+/-10%) LED Streetlight fitting powder coated pressure die cast aluminium body with separate driver as per the requirement with Driver efficiency>85%,internal surge protection of 5 KV L,N,E as per IEC 61000-4-5,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120 deg, suitable tiltable fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR,PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy≥135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size,beam angle and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Quote should include preparation & submission of lighting design , illumination calculations using industry-standard lighting design software, preparation of photometric layouts, lux-level calculations, uniformity calculations, glare assessment, lighting power density (LPD) calculations, complete as per instructions of Engineer-In-Charge. | 50 | Each | 3,500 ₹1,75,000 Lowest | 3,936 ₹1,96,800 | 3,750 ₹1,87,500 | 11,500 ₹5,75,000 | 4,600 ₹2,30,000 |
| 7.00Suppy of following size PVC insulated and PVC Sheathed XLPE armoured Aluminium conductor cable of 1.1KV grade confirming to IS:7098(Part-1),1988 with up to date amendments complete as required. | ||||||||
| 7.10 | 4C x 4 Sq.mm | 1,000 | Metre | 180 ₹1,80,000 | 252.15 ₹2,52,150 | 125 ₹1,25,000 Lowest | 145 ₹1,45,000 | 190 ₹1,90,000 |
| 7.20 | 4C x 10 Sq.mm | 750 | Metre | 300 ₹2,25,000 | 399.75 ₹2,99,812.5 | 170 ₹1,27,500 Lowest | 170 ₹1,27,500 Lowest | 300 ₹2,25,000 |
| 7.30 | 4C x 25 Sq.mm | 500 | Metre | 400 ₹2,00,000 | 543.66 ₹2,71,830 | 250 ₹1,25,000 Lowest | 300 ₹1,50,000 | 400 ₹2,00,000 |
Tender Value
₹1.7 Cr
EMD Value
₹3.4 L
Closing Date
11 Sept 2026, 3:00 pmClosed
SM (E-E), Gaya Airport, Gaya
SM (E-E), Gaya Airport, Gaya
Modification of existing Terminal Building and replacement of false ceiling at Gaya Airport. SH Internal Electrical Works
2026_AAI_288204_1
AAI/GY/SM(E-E)/e-NIT-07/26-27
Open Tender
Electrical Works
Works
180 days
Gaya Airport
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
₹3.4 L
23 Sept 2026
20 Aug 2026
12 Sept 2026
21 Aug 2026
11 Sept 2026
21 Aug 2026
21 Aug 2026 - 28 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply of 36 W(+/-10%) linear type LED luminaire (4 ft) suitable for mounting on false ceiling, made of extruded aluminum housing complying construction requirements as per IS:10322 with Driver efficiency>85%,internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, IK02, CRI ≥80, UGR(Unified Glare Rating)<19, Flicker free, (flicker should be below 5 %),life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K /5700°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching)<3,Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing (Stickers shall not be acceptable) complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted with technical datasheets for approval from EIC. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management:heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Quote should include preparation & submission of lighting design , illumination calculations using industry-standard lighting design software, preparation of photometric layouts, lux-level calculations, uniformity calculations, glare assessment, lighting power density (LPD) calculations, reflected ceiling plans (RCP) complete as per instructions of Engineer-In-Charge. | 720 | Each | 263 | ₹1,89,360 |
| 2 | Supply of 45 W(+/-10%) linear type LED luminaire(8 ft) suitable for mounting on false ceiling, made of extruded aluminum housing complying construction requirements as per IS:10322 with Driver efficiency >85%, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, IK02, CRI ≥80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching)<3,Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing(Stickers shall not be acceptable). complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted with technical datasheets for approval from EIC. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Quote should include preparation & submission of lighting design , illumination calculations using industry-standard lighting design software, preparation of photometric layouts, lux-level calculations, uniformity calculations, glare assessment, lighting power density (LPD) calculations, reflected ceiling plans (RCP) complete as per instructions of Engineer-In-Charge. | 200 | Each | 263 | ₹52,600 |
| 3 | Supply 600mm x 600 mm 36 W(+/-10%) LED recessed mounted panel suitable for mounting on false ceiling, made of extruded aluminum housing complying construction requirements as per IS:10322 with Driver efficiency >85%,internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, IK02, CRI ≥80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching)<3,Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/Screen printing on housing(Stickers shall not be acceptable) complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy≥135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted with technical datasheets for approval from EIC. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Quote should include preparation & submission of lighting design , illumination calculations using industry-standard lighting design software, preparation of photometric layouts, lux-level calculations, uniformity calculations, glare assessment, lighting power density (LPD) calculations, reflected ceiling plans (RCP) complete as per instructions of Engineer-In-Charge. | 250 | Each | 263 | ₹65,750 |
| 4 | Supply of 24 W(+/-10%) deep recessed LED Downlighter fittings suitable for mounting on false ceiling with housing complying construction requirements as per IS:10322 with Driver efficiency >85%, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, IK02, CRI ≥80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching)<3,Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/Screen printing on housing(Stickers shall not be acceptable) complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy≥120 lm/Watt output.LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted with technical datasheets for approval from EIC. Shape size, CCT and Beam Angle shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Quote should include preparation & submission of lighting design , illumination calculations using industry-standard lighting design software, preparation of photometric layouts, lux-level calculations, uniformity calculations, glare assessment, lighting power density (LPD) calculations, reflected ceiling plans (RCP) complete as per instructions of Engineer-In-Charge. | 200 | Each | 263 | ₹52,600 |
| 5 | Supply of 80 W(+/-10%) LED Surface mounted LED High Bay Light fittings powder coated pressure die cast aluminium body with separate driver as per the requirement with Driver efficiency>85%,internal surge protection of 5 KV L,N,E as per IEC 61000-4-5,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120 deg, suitable tiltable fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR,PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size,beam angle and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Quote should include preparation & submission of lighting design , illumination calculations using industry-standard lighting design software, preparation of photometric layouts, lux-level calculations, uniformity calculations, glare assessment, lighting power density (LPD) calculations, reflected ceiling plans (RCP) complete as per instructions of Engineer-In-Charge. | 60 | Each | 263 | ₹15,780 |
| 6 | Supply of 120 W (+/-10%) LED Streetlight fitting powder coated pressure die cast aluminium body with separate driver as per the requirement with Driver efficiency>85%,internal surge protection of 5 KV L,N,E as per IEC 61000-4-5,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120 deg, suitable tiltable fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR,PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy≥135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size,beam angle and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Quote should include preparation & submission of lighting design , illumination calculations using industry-standard lighting design software, preparation of photometric layouts, lux-level calculations, uniformity calculations, glare assessment, lighting power density (LPD) calculations, complete as per instructions of Engineer-In-Charge. | 50 | Each | 263 | ₹13,150 |
| 7Suppy of following size PVC insulated and PVC Sheathed XLPE armoured Aluminium conductor cable of 1.1KV grade confirming to IS:7098(Part-1),1988 with up to date amendments complete as required. | |||||
| 7.1 | 4C x 4 Sq.mm | 1,000 | Metre | 263 | ₹2,63,000 |
| 7.2 | 4C x 10 Sq.mm | 750 | Metre | 263 | ₹1,97,250 |
| 7.3 | 4C x 25 Sq.mm | 500 | Metre | 263 | ₹1,31,500 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.47 MB
TENDERDOCLIGHTS.pdf
Tender Documents • 8.54 MB
BOQ_336260.xls
BOQ • 0.58 MB
CORRIGENDUM-2.pdf
PDF • 0.14 MB
CORRIGENDUM1.pdf
PDF • 0.08 MB
CORRIGENDUM1.pdf
PDF • 0.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .