| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.7 LAccepted-AOC KG 115 SABIRA MANZIL HBR 2ND STAGE VENKATESH PURAM BANGALORE 560 045 | BENGALURU URBAN | KARNATAKA | 560045 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹19.4 L+₹20,108 (1.05%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹19.5 L+₹32,465 (1.69%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹20.0 L+₹83,545 (4.35%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹21.9 L+₹2.7 L (14.0%)Rejected-Finance 39 SR LAYOUT MAIN ROAD NAL WING TUNNEL ROAD MURUGESH PALYA BANGALORE 560 017 | BENGALURU URBAN | KARNATAKA | 560017 | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
3 Jul 2023, 6:00 pmClosed
GE CENTRAL BANGALORE
ASC CENTRE AND COLLEGE AGRAM POST BANGALORE 560007
REPAIRS MAINTENCE OF INTERNAL WIRING SUBMAIN MCCBS LIGHT FITTING WITH OTHER INTERNAL WIRING AT ORS MD ACCN AT VNC DOMLUR NP LINE GNCLINE RHM LINE MD ACCN WITH OTHER AREA GE CENTRAL BANGLORE
2023_MES_603219_1
8313E
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE CENTRAL BANGALORE
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE CENTRAL BANGALORE
₹64,000
Yes
22 Sept 2023
14 Jun 2023
5 Jul 2023
14 Jun 2023
3 Jul 2023
21 Jun 2023
14 Jun 2023 - 20 Jun 2023
Amount
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators, sockets etc. to be measured separately), removing taken down materials to a place where ordered for crediting including making good disturbed surfaces of walls, floors, etc to match with the existing surface complete all as directed..
M&L for point wiring for one light/ ceilig fan point / bell point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non-metallic rigid PVC concealed conduit (medium duty, ISI marked, not less than 20mm dia) with all fittings such as tee, bends, etc all as per IS, terminated in & including new sunk type pressed steel terminal boxes concealed in wall for mounting fittings like switches, sockets, regulators etc with and including 3mm thick phenolic laminated sheet top cover, complete all as specified and as directed. Note : Cost of cutting/leaving forming chases for conduits, sinking for boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
All as per item No. 2 above but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch socket on independent board -do-
All as per item No. 2 here-in-above, but for 5 Amp (2/ 3 pin), switch socket in same board with earth wire 1.5 Sq.mm PVC insulated multistranded copper conductor cable all as directed.
All as per item No. 2 here-in-above, but size of cable 2.5 Sq.mm for 3 Pin 15 Amp (3 pin) combined, switch socket in independent board with earth wire 2.5 Sq.mm PVC insulated multistranded copper conductor cable all as directed.
All as per item No. 2 here-in-above, but size of cable 4 Sq.mm for 3 pin & 15 Amp switch socket in independent board with earth wire 4 Sq.mm PVC insulated multistranded copper conductor cable all as directed.
M&L for point wiring for one light/ ceilig fan point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor cable 1100 Volt grade (ISI marked) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including 20 mm wide PVC rigid non-metalic condiut (Medium grade) on surface conforming to IS: 9537 with all fittings such as tee, bends, etc all as per IS, terminated in & including new MS terminal boxes fixed in wall for mounting fittings like switches, sockets, regulators etc with and including 3mm thick phenolic laminated sheet top cover, complete all as specified and as directed.
Supply and fix Switch piano, flush button Two way pole, 5 Amps
Supply and fix Switch piano, flush button single pole, 5 Amps one way.
Supply and fix bell push, flush button single pole, 5 Amps one way.
Supply and fix Switch sokcet combination flush type 5 Amp 2/3 pin muliti purpose
Supply and fix Switch socket combination flush type 6/16 Amps 3/3 pin universal multipurpose
Supply and fix Fan regulator electronic, step & socket type 230 volt, suitable for 1200/1400mm sweep ceiling fan.
Supply and fix Ceiling rose surface bakelite 65x50mm three terminals including supply and fix PVC blocks.
Supply and fix switch , flush type 16 amps (socket type with two/four screw holes).
Supply and fix socket, flush type 16 amps (socket type with two/four screw holes.
Supply and fix in repair Door bell electronic, music type, 230 volt AC. Make : Anchor/Havell/Polycab
Supply and fix in repair Fan capacitor 1.85/2.5/3.15 mfd suitable for 1200/1400mm sweep ceiling fan. Make : Anchor/Havell/Polycab
Supply and fix in repair Fan regulator electronic, step & socket type 230 volt, suitable for 1200/1400mm sweep ceiling fan.
Taking down existing light fittings fixed in any description and S&F new 10 Watt , 6000K, 230 Volt, 2ft Batten surface and wall mounted LED batten with polycarbonate housing with PVC housing & integrated electronic driver complete with all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete fixed as per manufacturers instructions and making necessary electrical connections and testing on completion complete all as directed. . Make : Havells/wipro/surya/ Philips
Taking down existing light fittings fixed in any description and S&F new 20 Watt , 6000K, 230 Volt, 4ft Batten surface and wall mounted LED batten with polycarbonate housing with PVC housing & integrated electronic driver complete with all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete fixed as per manufacturers instructions and making necessary electrical connections and testing on completion complete all as directed. . Make : Havells/wipro/surya/ Philips/Shakti
S&F in replacement of LED Luminarire 600mmx600mm 35/36 Watt , 230 volt, with recessed type with high efficiency PMMA diffuser soft glare free light complete with driver holders & LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm ,and old LED/FTL tube light fittings Deposit to store with all as specified and directed by Engr-in-charge. Make : Shakti/Crompton Greaves/Bajaj
S & F Exhaust fans steel body Ac single phase 230 v of size 300mm sweep with blades, frame and louvers with Provn of twin core cable of suitable size for ceiling rose to connector connecting of earth wire as complete all as directed,NOTE: Quoted rate deemed to be included for Core cutting machine hole by opening in any type of walls (Stone/Bricks) in the building including neccessary plastering, grouting of nuts & bolts and washers suitable size and neccessary fixing arrangement for fixing louvre and including making good to disturbed surface area to its original position. including Mouse safty mesh to be close from out side. Make: Bajaj/ Orient,Usha.
Taking down existing light fittings fixed in any description S&F new security light light fittings 1x 35 Watt LED street light with New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08 with all accessories and including connection up with twine core twisted flexible copper conductor cable with 1.5 M long suitable size fixed as per manufacturers instructions and making necessary electrical connections and testing on completion complete all as directed.Make : Havells/wipro/surya/shakti
S&F in repair security light bracket made out of 25 mm bore GI Light grade 1.00 M long to required shape as in bracket for steet light fittings fixed with two pair of MS flate iron clamp of size 50mm X 6 mm thickness of required shape with nuts, bolts and washers suitable for steel tubular pole complete all as specified and directed.
S&F in replacement Sheet metal enclosure (ISI marked) distribution board for 240 volts, SPN 12 way horizontal type, Double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete and with all as directed.
S&F in replacement Sheet metal enclosure (ISI marked) distribution board for 240 volts, SP 8 way horizontal type, Double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete and with all as directed.
S & F in replacement MCB single pole 6-32 Amps 240 volts, 10 kA rupturing capacity providing in DB complete e with all as specified and directed by Engr-in-charge. Make Indoasian
S & Fin replacement MCB single pole & neutral 40 Amps 240 volts, 10 kA rupturing capacity providing in DB complete all as specified. Make Indoasian
S&F in replacement Sheet metal enclosure (ISI marked) distribution board for 415 volts, TPN 04 way Vertical type, double door, Tripal pole and neutral with 200 Amps rated copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete all as directed.
S&F in replacement Sheet metal enclosure (ISI marked) distribution board for 415 volts, TPN 08 way Vertical type, double door, Tripal pole and neutral with 200 Amps rated copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete all as directed.
S&F in replacement Sheet metal enclosure (ISI marked) distribution board for 415 volts, TPN 12 way Vertical type, double door, Tripal pole and neutral with 200 Amps rated copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete all as directed.
S & F in replacement Isolator fore pole 100 Amps 415 volts, 25 kA rupturing capacity providing in DB complete all as specified Make Indoasian
Taking down old existing sub main wiring and provide new submain wiring with 2 runs of 2.5 Sqmm single core PVC insulated, unsheathed, multi stranded copper conductor and one single core 2.5 Sqmm PVC insulated , unsheathed , multi stranded copper cable as earthing lead as per IS : 694 / 1990 drawn through and including non-metallic PVC rigid conduit/casing caping of size as ordered in walls / ceilings etc with all accessories such as Tees, Elbows, junction box, reducers etc and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion complete all as specified and directed. (Note :- 2 runs 2.5 Sqmm cable , one run 2.5 Sqmm cable and one run of PVC Conduit /Casing caping shall be measured as one unit length) .
All as per item No 34 here-in-above but 2 runs with 4 Sqmm single core cable and 4 Sqmm single core as earth contunity wire -do- . (Note :- 2 runs 4 Sqmm cable , one run 4 Sqmm cable and one run of PVC Conduit/Casing caping shall be measured as one unit length)
All as per item No 34 here-in-above but 2 runs with 6 Sqmm single core cable and 6 Sqmm single core as earth contunity wire -do- . (Note :- 2 runs 6 Sqmm cable , one run 6 Sqmm cable and one run of PVC Conduit/Casing caping shall be measured as one unit length)
All as per item No 34 here-in-above but 4 runs with 10 Sqmm single core cable and 10 Sqmm single core as earth contunity wire -do- . (Note :- 4 runs 10 Sqmm cable , one run 10 Sqmm cable and one run of PVC Conduit/Casing caping shall be measured as one unit length)
M&L for taking down and dismantling of ceiling fan 1200mm/1400mm sweep 230 Volt 50 C/S AC of any make or model by opening the cover, separating down rod, rotor and stator assembly, locating the fault and making the fan fully in serviceable condition with & including replacing the bearing with similar type of exisitng one, worn out screws of the cover, split pin, twin core flexible copper wire of size 23/0.0076, locking nuts & machine screws with spring washer for ceiling fan blades, oiling and greasing etc, finally painting the ceiling fan with one coat of spray painting with white DUCO Paint & lettering & Numbering the same as per existing ,reassembling & testing the fan complete all as directed. Note :- (i) Capacitor shall be measured & paid seperately under items as “Supply only”. Rewinding shall also be measured & paid for separately (ii) Quoted rate is deemed to be inclusive of painting .
M&L for rewinding of ceiling fan of size 1200mm/1400mm sweep, 230 volt, 50 C/S, AC by removing of burnt winding from stator and rewinding the same with super enamelled copper winding wire of same gauge, same weight & turns including varnishing of winding & reassembling complete all as directed.
M&L for taking down and dismantling of Exhaust fan 300mm/450mm sweep 230 Volt 50 C/S AC of any make or model by opening the cover, separating rotor and stator assembly, locating the fault and making the exhaust fan fully in serviceable condition with & including replacing the bearing with similar type of exisitng one , worn out screws of the cover, twin core flexible copper wire of size 23/0.0076, rubber pad for legs, oiling and greasing etc, finally paint the exhaust fan with one coat of spray painting with white DUCO Paint & lettering & Numbering the same as per existing, reassembling & testing the fan complete all as directed. Note :- (i) (i) Capacitor shall be measured & paid seperately under items as “Supply only”. Rewinding shall also be measured & paid for separately (ii) Quoted rate is deemed to be inclusive of painting.
M&L for rewinding of exhaust fan of size 300mm sweep, 230 volt, 50 C/S, AC by removing of burnt winding from stator and rewinding the same with super enamelled copper winding wire of same gauge, same weight & turns including varnishing of winding & reassembling complete all as directed.
S & F in repair LED Driver 34 to 42 W, 240 Volt for 2'x2' LED fitting as per existing fitting (any type and make) complete all as directed.
S & F in repair LED Driver 24 to 36 W, 240 Volt for 2'x2' LED fitting as per existing fitting (any type and make) complete all as directed.
S & F in repair LED Driver 15 to 25 W, 240 Volt for 1'x1' and round LED fitting as per existing fitting (any type and make) complete all as directed.
S & F ceiling fans complete with blades, down rods,electronic regulator and accessaries 230v,1200mm sweep, Min air delivery 210 CFM with service Value 6.00 BEE Five star rated with Brushless direct current motor (BLDC) Provn of twin core cable of suitable size for ceiling rose to connector connecting of earth wire as complete all as directed
M&L for Earthing with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized iron earth wire 4 mm dia as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted to earth plate at one end and other end of earth wire connected to Pole / transformer / GOD / Panel / equipment body / test point /Bldg DB , GI earth wire encased in and including 15mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed including taking out old earthing.. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner
kamadhenu Electricals
RAMSON TRADERS
Chandana Enterprises
GKR and CO
TCR CONSTRUCTIONS
SREE VARU ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .