Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.8 LAccepted-AOC AT WASHERY ROAD KATHARA BOKARO JHARKHAND 829116 | KATHARA | BOKARO | JHARKHAND | 829116 | ₹3.8 L | L1 | Accepted-AOC ACCEPTED AS PER NIT |
| 2 | L2₹3.8 LRejected-Finance AT JHIRKEY PO KATHARA DIST BOKARO JHARKHAND | KATHARA | BOKARO | JHARKHAND | 829116 | ₹3.8 L | L2 | Rejected-Finance REJECTED AS PER NIT |
| 3 | L3₹3.9 LRejected-Finance MAIN ROAD KATHARA BOKARO 829116 | BOKARO | BOKARO | JHARKHAND | 829116 | ₹3.9 L | L3 | Rejected-Finance REJECTED AS PER NIT |
| Sl No | Description | Qty | Unit | M/S P. L. CONSTRUCTION L3 | M S ENTERPRISES L2 | M/S SHYAM ELECTRICALS L1 |
|---|---|---|---|---|---|---|
| 1.01 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C | 81 | point | 1,258.23 ₹1.0 L | 1,318.25 ₹1.1 L | 1,200 ₹97,200 |
| 1.02 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch Each | 42 | each | 85.25 ₹3,580.50 | 91.75 ₹3,853.50 | 40 ₹1,680 |
| 1.03 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
3 pin 5/6 A socket outlet | 36 | each | 119.5 ₹4,302 | 123.25 ₹4,437 | 45 ₹1,620 |
| 1.04 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
15/16 A switch | 2 | each | 167.5 ₹335 | 143.25 ₹286.50 | 80 ₹160 |
| 1.05 | Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
6 pin 15/16 A socket outlet | 2 | each | 215 ₹430 | 183.25 ₹366.50 | 90 ₹180 |
| 1.06 | Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed steel conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
(inner hall: 50m x 3 + outer hall: 30m x 3 + office room: 20m x 3) | 300 | m | 326 ₹97,800 | 300.3 ₹90,090 | 198 ₹59,400 |
| 1.07 | Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed steel conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | 70 | m | 409 ₹28,630 | 340.5 ₹23,835 | 250 ₹17,500 |
| 1.08 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75mmX75mm) | 8 | each | 330 ₹2,640 | 262.2 ₹2,097.60 | 200 ₹1,600 |
| 1.09 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
1 or 2 Module | 8 | each | 190 ₹1,520 | 120.32 ₹962.56 | 200 ₹1,600 |
| 1.10 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
8 Module (125mmX125mm) | 18 | each | 423 ₹7,614 | 409.25 ₹7,366.50 | 3,500 ₹63,000 |
Tender Value
Refer Docs
EMD Value
₹4,400
Closing Date
23 Mar 2026, 4:00 pmClosed
Project Engineer (EnM), Kathara Colliery
P.E. (EnM), Office of the PO, Kathara Colliery
Electrical repairing/re-wiring and changing of electrical items of Kathara OP Thana under Kathara Colliery.
2026_CCL_356563_1
KTC/PE/EnM/25-26/125 Date-13.03.2026
Open Tender
Electrical and Maintenance Works
10 days
P.E. (EnM), Office of the PO, Kathara Colliery
As per NIT
5 documents required · 5 mandatory
₹4,400
Yes
27 Mar 2026
13 Mar 2026
24 Mar 2026
13 Mar 2026
23 Mar 2026
13 Mar 2026
13 Mar 2026 - 19 Mar 2026
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch Each
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed steel conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire (inner hall: 50m x 3 + outer hall: 30m x 3 + office room: 20m x 3)
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed steel conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1 or 2 Module
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 8 Module (125mmX125mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 8 Module
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way double door
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 100A TP&N
Supply and fitting of Wall mounted, high speed fan of blade size 15inch or above
Supply and fitting of Ceiling light of 5W/9W: round panel of required size
Supply and fitting of high speed exhaust fan of size 9 inch
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6mm thick G.I. base plate including holes etc. complete as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Total impact of GST for the purpose of CTC
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.98 MB
BOQ_369415.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid