Loading…
Loading…
Tender Value
₹80.5 Cr
EMD Value
₹1.6 Cr
Closing Date
1 Sept 2026, 3:00 pm
Yes (up to 4 members)
Two Packet System
Normal Tender
Yes
07/08/2026 11:30
Lowest to Highest
90 days
Expenditure
Capital (Works)
PROJECT
17 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N OR 'V' Whichever is less; where. V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information , along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Bid Capacity: The tender/technical bid will be evaluated based on bid capacity formula detailed as Annexure-VI of GCC april 2022. As the advertised value is more than 10 Crore, the eligibility criteria is applicable.
4 conditions
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
GCC-2022, All correction slip of GCC, SOR-2025 Drawing & Annexures, other Drawing, Policies & Circulars are attached with the tender.
Composite work of Survey, Design, Supply, Installation, Testing & Commissioning of Automatic Signalling work using Multi Section Digital Axle counter for continuous track circuiting along with Electronic Interlocking in Auto huts and alteration in existing Electronic/Relay Interlocking at adjoining stations with associated works including Construction & Electrification of mid-section auto block hut (S&T Service Building) between Madha - Tikekarwadi section of Solapur Division of Central Railway
SUR-SNT-PROJ-02-ABS-2026
SUR-SNT-PROJ-02-ABS-2026
Open
Works - General
24 Months
Mumbai, Maharashtra
₹0
₹1.6 Cr
27 Jul 2026
27 Jul 2026
18 Aug 2026
7 Aug 2026
364 items across 42 schedules · ₹71,54,35,889.73 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Supply of tool kit- required for Trouble Shooting and repair of hardware and software for EI system should be supplied for stations as per schedule item 1 above. (This includes tools required for EI maintenance sorts of crimping, insertion, removal, general purpose tools like screw drivers, spanners, PCB extractor, temp. controlled soldering iron, wire cutter, nose plier etc. & measuring instruments with carrying case/ holders/cabinet for technicians/ J.E. or testing, Maintenance and repair at site). Each set comprises of the following :- (a) Crimping tools for all types of special cable assembly used in EI system. (b) Insertion tool for all types of special cable assembly used in EI system. (c ) Removal tools for all types of special cable assembly used in EI (d) Digital multimeter (Tektronics/Fluke/MEGGER/RISHAV or better) system. (e) Steel cabinet / Almira (Godrej/Durian/Transteel) of good quality to store tool, spare cards and documents. (f) Clamp Earth Tester. (Fluke 287/MEGGER/RISHAV or better) (g) Clamp Current Meter. (Fluke 287/MEGGER/RISHAV or better) (h) 6 nos. Electrostatic Discharge Wrist Band for cards modules protection. ( Inspection Agency Consignee ) | Set | 2.00 | 1,06,064 | 2,12,128 |
| 2 | Modification in existing EI system as per latest TAN, it includes:- Design and modification in existing interface and interlocking circuit of EI system, including modification in VDU,CCIP, MT, Data logger, EI, Relay rack complete wiring conforming to RDSO specification, as per technical requirement & tentative approved signaling plan/diagrams. Required hardware will be provided by railways except the wiring, material (i.e. connectors, interconnecting cable/wires, fuses etc.) The work includes supply of modified ST/LT, interface and logic circuit, CCIP/VDU diagram etc. to suit the approved interlocking plan. It also includes modification in data logger/MT, carrying out FAT, SAT jointly with railways and satisfactory commissioning of the modified EI with full complements as per approved IP and central railway practices. All plans and wiring diagrams shall be prepared on AUTOCAD and supplied in both soft copy and hard copies (6 sets.)Alteration involving modification in more than 11 and up to 20 routes NOTE : If the alteration involves modification of routes up to 10, fixed cost as per the Rate mentioned in (i) above shall be paid. If the alteration involves modification of routes are more than 10 up to 20 routes, then, fixed cost as per the Rate mentioned in (ii) above shall be paid. | Per Alteration | 5.00 | 22,23,143 | 1,11,15,715 |
| 3 | Supply of Relay rack assembly complete with scaffolding, fixtures and accessories including MS Bars for fixing of relay plug board, string rods, fuse strips with bracket, 11 way Bus bars with cover and mounting brackets, runway for cable/wires, frame, base assembly etc. Siemens type & as per extant practice on C.Rly. Typical part list as per Annexure-II and Rack arrangement as per sketch no SK-727 and Rack plan as approved by Engineer in charge. ( Inspection Agency RITES ) | Set | 30.00 | 30,325 | 9,09,750 |
| 4 | Supply of Tag blocks 200/160/120 way with polycarbonate cover as per IRS S 77-2006. (Rev.1) RDSO DRG. No.SA 24751, SA 24752 & SA 24753. Requirement of each type shall be specified by Engineer-in-charge. ( Inspection Agency RDSO ) | Numbers | 64.00 | 1,217 | 77,888 |
| 5 | Supply of tag blocks 96/100 way with polycarbonate cover as per IRS S 77-2006. (Rev.1) Requirement of each type shall be specified by Engineer-in-charge. ( @40@Inspection Agency RDSO ) | Numbers | 24.00 | 1,391 | 33,384 |
| 6 | Supply of Main cable Termination rack complete with scaffolding, fixtures & accessories including square bars for mounting 8-way terminal blocks, ladder, string rods, frame, base assembly, insulators, J bolt , nut/bolts & fasteners, backelite sheet, etc. Siemens type and as per extant practice of Central Railway. Typical part list as per Annexure-III and rack arrangement shall be as per sketch No.SK-727 with latest alterations. ( Inspection Agency RITES ) | Set | 33.00 | 26,006 | 8,58,198 |
| 7 | Supply of Data logger for monitoring status of important relays, complete with processor Module to monitor following inputs as per spec. RDSO/SPN/99/2006 Spec. No: IRS:S-99/2006 (Amdt-3) with latest amendments including power supply of adequate capacity, battery and fault diagnostic software for failure analysis. Complete data logger & Processor Module (computer) as per Annexure-IV shall be placed in President rack of suitable size to be supplied. This also includes supply of one no. composite computer & printer table (work station table- Godrej/Durian/Transteel) for keeping processor module and one no. Godrej/Durian/Transteel make operator chair. i)1024 digital and 32 analog inputs. ( Inspection Agency RDSO ) | Set | 12.00 | 5,72,233 | 68,66,796 |
| 8 | Supply of PVC Indoor cable 1x60x0.6mm dia color coding of insulation of inner core shall be in six color viz Blue, Red, Grey, Green,Brown & Black conforming to IRS 76/89 (Amd.3) or latest. ( Inspection Agency RDSO ) | Kilometre | 4.40 | 2,60,430 | 11,45,892 |
| 9 | Supply of PVC Indoor cable 1x40x0.6mm dia color coding of insulation of inner core shall be in eight color viz Blue, Red, Grey, Green, Brown, Black, Yellow & White conforming to IRS 76/89 (Amd.3) or latest. ( Inspection Agency RDSO ) | Kilometre | 4.40 | 1,70,848 | 7,51,731.2 |
| 10 | Supply of PVC indoor cable 1x24x1 mm dia. Color coding of insulation of Inner conductor shall be in eight colour viz, Blue, Red, Grey, Green, Brown, Black, Yellow & white confirming to IRS 76/89 (Amd. 3) or latest. ( Inspection Agency RDSO ) | Kilometre | 2.10 | 2,46,408 | 5,17,456.8 |
| 11 | Supply of Indoor Jumper wire of various colour as per Railways standard practice of type ATC 1x0.6 mm dia. Conforming to IRS/76/89 (Amd.3) of latest. ( Inspection Agency RDSO ) | Kilometre | 12.00 | 7,770 | 93,240 |
| 12 | Supply of Indoor Jumper wire ATC 1x1 mm dia. Conforming to IRS/76/89 (Amd.3) of latest. ( Inspection Agency RDSO ) | Kilometre | 2.70 | 11,585 | 31,279.5 |
| 13 | Supply of PVC flexible copper cable single core, multistrand 1x6 Sq.mm (84 conductor each diameter 0.30 +/- 0.01) as per IS 694/2010. with latest amendment if any with insulation thickness of 0.80 mm nominal conductor resistance 3.30 ohms/km and test parameters are as per IRS (S) 76/89 (Amd.3)or latest. ( Inspection Agency RDSO ) | Kilometre | 8.40 | 76,141 | 6,39,584.4 |
| 14 | Supply of PVC flexible copper cable single core, multistrand 1x10 Sq.mm (80 conductor each diameter 0.40 +/- 0.01) as per IS 694/2010. with latest amendment if any with insulation thickness of 1.0 mm nominal conductor resistance 1.91 ohms/km and test parameters are as per IRS (S) 76/89 (Amd.3)or latest. ( Inspection Agency RDSO ) | Kilometre | 4.20 | 1,19,222 | 5,00,732.4 |
| 15 | Supply of PVC flexible copper cable single core, multistrand 1x16 Sq.mm (126 conductor each diameter 0.40 +/- 0.01) as per IS 2465/1984 & IS: 694/2010. with latest amendment if any with insulation thickness of 1.0mm nominal conductor resistance 1.121 ohms/km and test parameters are as per IRS (S) 76/89 (Amd.3)or latest. ( Inspection Agency RDSO ) | Kilometre | 2.10 | 1,77,112 | 3,71,935.2 |
| 16 | Supply of wire 16/0.2 (Blue, Red, Grey, yellow, Brown, Black, White as per site engineer instruction) finolex/polycab/delton make. IRS:S- 76/89 (Amd.3), BS: 4808 Part-2. Wire to be procured from RDSO approved vender. ( Inspection Agency RDSO ) | Kilometre | 21.00 | 5,605 | 1,17,705 |
| 17 | Supply of Rubber Mat 5mm thick for use in signaling installation. ( Inspection Agency Consignee ) | Kg | 180.00 | 112 | 20,160 |
| 18 | Supply, installation, wiring, testing & commissioning of Microcontroller based Power Supply Autochangeover device complete along with accessories using Contractor's own wiring & fixing material as per following configuration- (i) Power Supply - AC/DC. (ii) Voltage 24V to 150V. (iii) Current Up to - 45Amp. Note: The work shall be done as per instructions of Railway's Engineer in-charge ( Inspection Agency RITES ) | Numbers | 84.00 | 31,274 | 26,27,016 |
| 19 | Relay base plate complete with amphanol's, code pins, fixing screws etc. suitable for Metal to Metal K-50 mini groups/ECRs of Siemens Make or functional equivalent of other makes.Note : Relay Base plates, are to be procured from Relay manufacturer (OEM). Manufacturer's Certificate for procurement and guarantee in this regard should be furnished. The payment to be released only after Manufacturer's Certificate is submitted. ( Inspection Agency Consignee ) | Numbers | 308.00 | 654 | 2,01,432 |
| 20 | Major Relay Group Base Plates, complete with fedlisters (20 No per base plate), guide rails and other accessories suitable for major group of Siemens make or functional equivalent of other makes.Note : Relay Base plates, are to be procured from Relay manufacturer (OEM). Manufacturer's Certificate for procurement and guarantee in this regard should be furnished. The payment to be released only after Manufacturer's Certificate is submitted. ( Inspection Agency RITES ) | Numbers | 64.00 | 11,864 | 7,59,296 |
| 21 | Supply of signal group 3 aspect without base plate Siemens make (No.A-RT-RG-A067) or functional equivalent and should be suitable for working with LED based signal lighting unit. ( Inspection Agency RDSO ) | Numbers | 24.00 | 49,131 | 11,79,144 |
| 22 | Supply of Time Element Relay (Clock work type) AG timer Siemens make (No.RSSK 30/0052) or GIC make or functional equivalent. ( Inspection Agency RDSO ) | Numbers | 8.00 | 6,780 | 54,240 |
| 23 | Supply of Plug In type Relay Metal to Metal type neutral relay mini groups (Non AC Immunized) Siemens make (No.RSSK 30/0011) (Ref.IRS:S46/74 with Amd.1 & firms specification). or functional equivalent without base plates. Contact configuration 5F/3B or 6F/2B or 4F/4B to be specified by Engineer incharge. ( Inspection Agency RDSO ) | Numbers | 160.00 | 6,915 | 11,06,400 |
| 24 | Supply of Plug In type Relay Metal to Metal type neutral relay mini groups ( AC Immunised-1) Siemens make (No.RSSK 30/0078-1) (Ref.IRS:S46/74 with Amd.1 & firms specification). or functional equivalent without base plates. Contact configuration 5F/3B or 6F/2B or 4F/4B to be specified by Engineer incharge. ( Inspection Agency RDSO ) | Numbers | 80.00 | 7,355 | 5,88,400 |
| 25 | Supply of Plug In type Relay Interlocked Siemens make (No. RSSK 30/0012) or functional equivalent (Ref. IRS:S46/74 with Amd. 1 & firms specification). Contact configuration 4F/4B. ( Inspection Agency RDSO ) | Numbers | 48.00 | 6,822 | 3,27,456 |
| 26 | Supply of Metal - To - Metal universal LED type ECR Siemens make (type A-RT-RG-A064) or functional equivalent without base plates, should be suitable for working with LED based signal lighting unit. IRS:S 46/74 with Amd. 1 & STS/E/RELAYS/AC LIT LED SIGNAL/09-2002 Amd.1 ( Inspection Agency RDSO ) | Numbers | 40.00 | 5,859 | 2,34,360 |
| 27 | Fail safe Electronic Time delay unit (Plug In type) to operate 24VDC with only one fixed time setting of 30@47<47@120 seconds as per RDSO Specification No.IRS-S-61/2000 with Amendment No.3 or Latest. ( Inspection Agency RDSO ) | Numbers | 12.00 | 3,409 | 40,908 |
| 28 | Supply of QNA1 AC immunized relay, 8F-8B, 24 VDC along with plug, board, retaining clip and connectors conforming to BRS:931A,IRS:S60/78 with Amendment no.1 , IRS:S34/68 with Amendment no.6 & IRS:S23/88 with Amendment no.1 ( Inspection Agency RDSO ) | Numbers | 810.00 | 3,359 | 27,20,790 |
| 29 | Supply of QN1 Non AC immunized neutral relay, 8F-8B, 24 VDC along with plug, board, retaining clip and connectors conforming to BRS:930, IRS:S60/78 with Amendment no.1 , IRS:S34/68 with Amendment no.6 & IRS:S23/88 with Amendment no.1 ( Inspection Agency RDSO ) | Numbers | 570.00 | 3,507 | 19,98,990 |
| 30 | Supply of QN1 Non AC immunized neutral relay, 12F-4B, 24 VDC along with plug, board, retaining clip and connectors conforming to BRS:930,IRS:S60/78 with Amendment no.1 , IRS:S34/68 with Amendment no.6 & IRS:S23/88 with Amendment no.1 ( Inspection Agency RDSO ) | Numbers | 90.00 | 3,876 | 3,48,840 |
| 31 | Supply of QNA1K relay 1000 ohm, 6F/6B 24V DC as per BRS :931A, IRS:S60, IRSS354 & IRS:S23 and RDSO Spec. STS/E/Relays/UEA (PI) dtd.30.05.1997 Annexure II (IRS:S60/78 with Amendment no.1 , IRS:S34/68 with Amendment no.6 & IRS:S23/88 with Amendment no.1) ( Inspection Agency RDSO ) | Numbers | 210.00 | 3,415 | 7,17,150 |
| 32 | Supply of Relay & plug board QN1 / 50V/ 8F-8B Metal to carbon DC neutral-BRS:930,IRS:S60/78 with Amendment no.1 , IRS:S34/68 with Amendment no.6 & IRS:S23/88 with Amendment no.1 ( Inspection Agency RDSO ) | Numbers | 10.00 | 4,504 | 45,040 |
| 33 | Supply of Domino units with cover plate as per approved panel diagram, each of size 54 x 34mm completely wired up similar to siemens make. Each domino units should have all the 15 contact terminals wired up. ( Inspection Agency Consignee ) | Numbers | 216.00 | 1,440 | 3,11,040 |
| 34 | Panel Indication bulbs (Double LED type) working voltage 24V - Colour - Red/Yellow/Green. ( Inspection Agency Consignee ) | Numbers | 160.00 | 38 | 6,080 |
| 35 | Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92 With holder 1.6 A (System, Rapid or Malnad Make). ( Inspection Agency Consignee ) | Numbers | 240.00 | 70 | 16,800 |
| 36 | Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92 With holder 0.6 A (System, Rapid or Malnad Make). ( Inspection Agency Consignee ) | Numbers | 240.00 | 68 | 16,320 |
| 37 | Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92 With holder 6 A/10A (D-Type Bharat Linder, L&T or HEVELLS Make). ( Inspection Agency Consignee ) | Numbers | 25.00 | 230 | 5,750 |
| 38 | Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92 Without holder 1.6 A (System, Rapid or Malnad Make). ( Inspection Agency Consignee ) | Numbers | 240.00 | 20 | 4,800 |
| 39 | Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92 Without holder 0.6 A (System, Rapid or Malnad Make). ( Inspection Agency Consignee ) | Numbers | 240.00 | 20 | 4,800 |
| 40 | Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92 Without holder 6 A/10A (D-Type Bharat Linder, L&T or HEVELLS Make). ( Inspection Agency Consignee ) | Numbers | 10.00 | 82 | 820 |
| 41 | Resin cored wire as per specification No.IS:1921-1975 with Alloying element percentage as 63% SN (Tin) nd / 37% Pb (Lead) with percentage of various impurities not exceeding the values Sb (Antimony 0.2% maximum, Cu (Copper) 0.1% maximum, As (Arsenic) 0.05% maximum, Fe (Iron) 0.02% maximum & other impurities mainly AI, Zn & Cd shall be limited. The flux shall be free from corrosive action as per clause 5.2 & flux percentage may be used as per requirement. ( Inspection Agency RITES ) | Kg | 12.00 | 1,078 | 12,936 |
| 42 | Lacing thread rolls, black, wax coated (100 mtrs) ( Inspection Agency Consignee ) | Numbers | 100.00 | 57 | 5,700 |
| 43 | Fabrication and supply of Boar made of White sunmica sheet over 12 mm thick particle/Laminated/wooden board covered with 5mm thick perspex transparent sheet in aluminium/ steel frame and painting of SWR / Track insulation plan etc. ( Inspection Agency Consignee ) | Sqm | 60.00 | 6,084 | 3,65,040 |
| 44 | Design, fabrication and supply of fuse Auto changeover system for 32 Nos external non detorating type fuses or 'G' type fuses from 0.6A Amp to 4A Amp capacities used in signaling circuits. System shall have 8 cards with monitoring arrangement of 4 fuses in one card. As per RDSO spec. RDSO/SPN/209/2012 Ver.2.0 or latest amendment if any. ( Inspection Agency RDSO ) | Each Module | 66.00 | 23,147 | 15,27,702 |
| 45 | Supply of Main signal post 140 mm outer dia 4.6 Mtr Length as per spec No.IRS S 6/81 with latest amendments. ( Inspection Agency RITES ) | Numbers | 136.00 | 5,979 | 8,13,144 |
| 46 | Supply of Main signal post 140 mm outer dia 5.6 Mtr Length as per spec No.IRS S 6/81 with latest amendments. ( Inspection Agency RITES ) | Numbers | 10.00 | 8,119 | 81,190 |
| 47 | Supply of Cast Iron Main signal surface base 140mm as per spec No IRS: S-10 and Drg No 2011/M with latest amendments, with CLS Ladder assembly complete for CLS signal 5.5/4.5/3.5 mtrs long as per RDSO Drg no. SA 23156 (Adv), SA 23153 (Adv) & SA 23150 (Adv) Alt.1 respectively with Latest Amendment as the case may be for CLS unit & signal back staging as per extent C.Rly practice. ( Inspection Agency RITES ) | Numbers | 136.00 | 7,944 | 10,80,384 |
| 48 | Supply of Signal No.Plates as per Drg No RST- 11393/ SK-842 ( Inspection Agency Consignee ) | Numbers | 136.00 | 447 | 60,792 |
| 49 | OFF set bracket 5-1/2" to suit 140 mm dia CLS Post with two no. of "U" Bolts with nut & washer complete as per RDSO Drg No SA-23080 for signals & Routes. ( Inspection Agency Consignee ) | Numbers | 10.00 | 821 | 8,210 |
| 50 | Supply of A/AG/C/P/G/IB Board as per Drg. RST- 11444/1(A), RDSO Drg No SA-23460(AG), SA- 23461(C) , RST-11445, SA 23456(P), SA 23477(G) & SA 23476-77 (IB) as applicable respectively with Latest Amendment. ( Inspection Agency Consignee ) | Numbers | 120.00 | 476 | 57,120 |
| 51 | Supply of different warning Board as per Goods warning Board (SK-784) RDSO Drg No. SA 2380 (Adv), SA 2370/M-, Block section limit Board RDSO Drg No. SA 2373 - Paint and retroreflective arrangement as per Railways drawing. ( Inspection Agency Consignee ) | Numbers | 6.00 | 2,795 | 16,770 |
| 52 | Supply of Hand Cuff Locks / Godrej Navtal lock with Three common keys. ( Inspection Agency Consignee ) | Numbers | 408.00 | 245 | 99,960 |
| 53 | Supply of "4 aspect" Signal Unit in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev.2.0 or latest complete and to suit LED signal Lamps and suitable for 140 mm dia post saves pigment finish on the back side of the and inside. white pigment finish inside the 4 aspect unit to avoid any extra paint cost ( Inspection Agency RITES ) | Numbers | 146.00 | 34,638 | 50,57,148 |
| 54 | Supply of 1 way junction Route Indicator in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev. 2.0 or latest complete and to suit LED signal Lamps ( Inspection Agency RITES ) | Numbers | 8.00 | 29,381 | 2,35,048 |
| 55 | Supply of 2 way junction Route Indicator in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev. 2.0 or latest complete and to suit LED signal Lamps ( Inspection Agency RITES ) | Numbers | 2.00 | 36,469 | 72,938 |
| 56 | Supply of 3 way junction Route Indicator in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev. 2.0 or latest complete and to suit LED signal Lamps ( Inspection Agency RITES ) | Numbers | 6.00 | 38,672 | 2,32,032 |
| 57 | Supply of "Calling On" Signal Unit in FRP body without lenses and transformers as per RDSO Specification RDSO/SPN/194/2006/Rev. 2.0 or latest complete and to suit LED signal Lamps ( Inspection Agency RITES ) | Numbers | 90.00 | 7,154 | 6,43,860 |
| 58 | Supply and Fixing of RE Protective Screens of expanded metal 12 SWG of size 1200 x 1500 mm on signals as per extent practice & as per instruction of Rly engineer at site DRG - No.SK- 844 ( Inspection Agency Consignee ) | Numbers | 8.00 | 4,381 | 35,048 |
| 59 | Supply of Phenolic 10mm thick sheet, grade P3 in standard size of 1.22x1.22 Mtr as per spec. No. IS 2036 of 1995. ( Inspection Agency RITES ) | Numbers | 349.00 | 4,649 | 16,22,501 |
| 60 | Supply of ARA Terminal blocks with links made of PBT Specn No.IRS/75/2006 (Rev - 2) with latest amendments and RDSO Drg.No.SA- 23741A Alt.4., SA-23745 Alt.5, SA-23746, SA- 23748 Alt.4, & SA-23756 Alt.3. ( Inspection Agency RDSO ) | Numbers | 51000.00 | 65 | 33,15,000 |
| 61 | Supply of cartridge fuse block made of PBT as per RDSO Drg No SA-23748 Alt 4, SA-23749 & Spec No.IRS S 75/2006 Rev.02 with latest amendment. Fuse block shall be suitable for round head type voltage fuses. ( Inspection Agency RDSO ) | Numbers | 816.00 | 144 | 1,17,504 |
| 62 | Supply of round head type non detoriating type low voltage cartridge fuse as per specn No. IRS/S/78/92 with latest amendments - 2A/4A/6A capacity ( Inspection Agency RDSO ) | Numbers | 408.00 | 62 | 25,296 |
| 63 | Supply of Tik-tak, piano type switches, 5 A (as per IS Specification). ( Inspection Agency Consignee ) | Numbers | 408.00 | 30 | 12,240 |
| 64 | Supply of three pole plug and socket 5 Amp (as per IS Specification). ( Inspection Agency Consignee ) | Numbers | 408.00 | 205 | 83,640 |
| 65 | Supply of Lamp 110V / 24W, 2 pin for Loc. ( Inspection Agency Consignee ) | Numbers | 408.00 | 20 | 8,160 |
| 66 | Supply of Apparatus case with godown locks with detachable handle on both the doors.a) Single Case as per Drg No SK 783-1 & 2. with latest alteration. ( Inspection Agency RITES ) | Numbers | 272.00 | 14,252 | 38,76,544 |
| 67 | Supply of Apparatus case with godown locks with detachable handle on both the doors. b)Half Case as per Drg No SK 783-1 & 2. with latest alteration. ( Inspection Agency RITES ) | Numbers | 136.00 | 11,287 | 15,35,032 |
| 68 | Supply of earth electrode assembly as per Drg.No.CR/S&T/SK-815 ( Inspection Agency RITES ) | Numbers | 544.00 | 951 | 5,17,344 |
| 69 | Supply of Lightning strike recorder LSC 6 digit shall be weather proof type. It should have 6 digit event count & the capacity to count smallest strike (3KA). It should be voltage sensing type counter. So that it will register nearby strikes & static discharge due to induction effect. as per IS 2309:1989. ( Inspection Agency Consignee ) | Numbers | 12.00 | 12,067 | 1,44,804 |
| 70 | Maintenance Free Earth as per RDSO/SPN/197/2008 or latest consisting of : 1) Copper bond steel electrode 3 Mtr long 17mm dia with copper bonding thickness of min. 250micron & UL listed & marked-01 No. (2) Earth enhancement compound RDSO Approved in sealed bag of 10 kgs - 03 No. (3) Copper strip 150 x 25 x 6mm - 02 No (4) Copper Strip 300 x 25 x 6mm- 01 No (5) 35 Sqmm Copper Cable to connect earth electrode to MEEB - 15Mtr Approx. ( Inspection Agency RDSO ) | Set | 472.00 | 15,671 | 73,96,712 |
| 71 | Supply of 35 Sq. mm. multistrand single core PVC insulated copper for connecting earth bus bar to earth electrode. ( Inspection Agency RDSO ) | Metre | 315.00 | 365 | 1,14,975 |
| 72 | Supply of Microprocessor based universal earth resistance sensing unit 12 channel AC/DC. As per RDSO/SPN/256/2002 with latest amendments. ( Inspection Agency RDSO ) | Numbers | 24.00 | 1,18,645 | 28,47,480 |
| 73 | Supply of 8 SWG GI wire (4mm dia) suitable for track circuit rail bonding. As per IRS Specification S:13-62 ( Inspection Agency Consignee ) | Kg | 100.00 | 75 | 7,500 |
| 74 | SUPPLY of Electronic timers for DAC reset arrangement 3 sec to 30 sec with 2NO/2NC contact working voltage 24V/60V DC. Siemens/ABB/L&T or SELEC(642X A programmable electronic timer switch) make. ( Inspection Agency RITES ) | Numbers | 250.00 | 2,387 | 5,96,750 |
| 75 | Supply of Multi strand twin twisted core shielded cable of 28 - 30/0.2 mm for Axle counter as per IRS spec. 76/89 with Amendment No.03 or latest amendments, if any. Unit(1 Set= Per 100 meters) ( Inspection Agency RDSO ) | Set | 42.00 | 12,606 | 5,29,452 |
| 76 | Supply of GI pipe, inner dia. 100mm dia. B-class as per spec. No.IS 1239 PT. 1/2004 or latest with sockets and fittings. TATA/JINDAL/ZENITH BIRLA make. ( Inspection Agency RITES ) | Metre | 5000.00 | 908 | 45,40,000 |
| 77 | Supply of DWC HDPE pipe with one snap fit coupler and 'O' ring fire resistant, anti rodent, in 6 meter length of size 120 mm outer dia as per RDSO/SPN/204/2011 Ver 1.1 with Amd.1 or latest. ( Inspection Agency RITES ) | Metre | 5000.00 | 288 | 14,40,000 |
| 78 | Supply of RCC pipes half round of size 150mm dia outer and 100 mm dia internal 1 mtr long matching to IS No.458/2003 amendment-1 with Rev.4. ( Inspection Agency RITES ) | Numbers | 6000.00 | 189 | 11,34,000 |
| 79 | Supply of RCC pipes half round of size 300 mm dia outer and 250 mm dia internal 1 mtr long matching to IS No.458/2003 amendment-1 with Rev.4. ( Inspection Agency RITES ) | Numbers | 66000.00 | 365 | 2,40,90,000 |
| 80 | SUPPLY OF "C" CHANNEL CLAMPS with nut bolts, washers and all type fixures for 6 inch dia pipe to be fixed on GIRDERS, on rock cuttings etc. as per DRG No.-SK-900 ( Inspection Agency Consignee ) | Numbers | 250.00 | 1,867 | 4,66,750 |
| 81 | Supply of modular terminal block of 2.5 sq. mm 2 IN 2 OUT type disconnect type terminal along with as per RDSO SPN/189/2004 Rev 3.0. The current capacity of 16 Amps and more. The terminal should have marking at centre to view description from front. Material to be procured from RDSO approved firms only. ( Inspection Agency RDSO ) | Numbers | 21000.00 | 100 | 21,00,000 |
| 82 | Supply of DIN Channel for the terminals 1 Mtrs each ( Inspection Agency Consignee ) | Numbers | 420.00 | 187 | 78,540 |
| 83 | Supply of End plates for modular terminal block ( Inspection Agency Consignee ) | Numbers | 3570.00 | 20 | 71,400 |
| 84 | Supply of End Clamp for modular terminal block ( Inspection Agency Consignee ) | Numbers | 1050.00 | 15 | 15,750 |
| 85 | Supply of Marker Card as per customer spec (10x10) ( Inspection Agency Consignee ) | Numbers | 2100.00 | 71 | 1,49,100 |
| 86 | Operating tool (operating tool, screw driver & stripper) as per Annexure-VII. ( Inspection Agency Consignee ) | Numbers | 6.00 | 7,266 | 43,596 |
| 87 | Tool bag complete with Megger as per Annexure- VIII. ADD AC / DC clamp meter, with Hand Held Tool Bag. ( Inspection Agency Consignee ) | Set | 6.00 | 42,990 | 2,57,940 |
| 88 | Supply of Digital measuring wheel for measuring cable trench/route make: Stanley or Freemens make or similar reputed make. ( Inspection Agency Consignee ) | Numbers | 2.00 | 3,856 | 7,712 |
| 89 | Supply of Adhesive Tapes rolls, PVC (18mm x 25 Mtr) Steel Grip/SCOTCH/ANCHOR. ( Inspection Agency Consignee ) | Numbers | 250.00 | 28 | 7,000 |
| 90 | Supply of Thermo-Shrink cable joining kit (Reinforced) TSF-2 type generally confirming to RDSO specification RDSO/SPN/TC/57/2015 Rev 1 with modified kit contents as per CSTE's Specification No.:CR/SPN/TC/57 (A)/2015 Dt: 06.01.2015 (Table-A) to be suitable for jointing both 10/20/50 pair PIJF and 4/6 Quad cables alongwith sub-kit (Table-B) for armour continuity. ( Inspection Agency RDSO ) | Numbers | 30.00 | 2,710 | 81,300 |
| 91 | Supply of Paints as per relevant IS specification preferably Asian / Apcolite/ Dulux make in different colour in one kg/2 kg pack ( Inspection Agency Consignee ) | Kg | 200.00 | 306 | 61,200 |
| 92 | Supply of Trans-receiver handheld 5 watt Analog VHF set along with two sets of OEM approved rechargeable battery including one as spare, quick Battery Charger, Helical Antenna and Belt Clip conforming to RDSO specification no.RDSO/SPN/TC/107/2018 Ver 2.1 or later. ( Inspection Agency Consignee ) | Set | 12.00 | 11,449 | 1,37,388 |
| 93 | Supply of 4.5 kg CPO2 type fire extinguisher along with all accesories, extinguisher testing certificate has to be supplied along with - Supply of ISI marked Carbon Dioxide type (BC) fire extinguisher of 4.5 Kg capacity confirming to IS 2878: 2004 from seamless cylinder, with IS marked control value, high pressure mtr., Long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting bracket etc. as required by site Engineer. ( Inspection Agency RITES ) | Numbers | 60.00 | 4,321 | 2,59,260 |
| 94 | Supply, Installation, Testing & Commissioning of Microprocessor based intelligent, addressable, Fire Alarm control Panel with LCD display complying to RDSO/SPN/217/2025 Ver 3.1 or latest modular, 1 loop (minimum 125 detector/devices per loop-expandable to 2 loops) with 320 Character with soft keys for displaying alarm, events and operating functions, Day/Night operation function, Remote maintenance service feature etc. The panel should be multi-protocol i.e. able to support at least 2 different makes of addressable detectors. The panel should have minimum two relay outputs & 1 Monitored Sounder Output. It should have provision to be connected to repeater panels in future. The panel shall capable to operate on 230 volts AC power supply, automatic battery charger, 24 volts, sealed lead acid maintenance free batteries sufficient for 24 hours normal working and then be capable of operating the system for 30 minutes during emergency condition. Panel should be Vds Certified. ( Inspection Agency RDSO ) | Numbers | 12.00 | 55,467 | 6,65,604 |
| 95 | Suply, Installation, Testing & Commissioning of Analogue Addressable Multisensor Detector complying to RDSO/SPN/217/2025 Ver 3.1 or latest. As per latest VDS approved/Listed. ( Inspection Agency RDSO ) | Numbers | 180.00 | 2,748 | 4,94,640 |
| 96 | Suply, Installation, Testing & Commissioning of Manual call points, complying to RDSO/SPN/217/2025 Ver 3.1 or latest. As per latest VDS approved/Listed. ( Inspection Agency RDSO ) | Numbers | 12.00 | 4,313 | 51,756 |
| 97 | Suply, Installation, Testing & Commissioning of Resettable, Analogue Type Liner Heat Sensing (LHS) Cable complying to RDSO/SPN/217/2025 Ver 3.1 or latest. As per latest VDS approved/Listed. ( Inspection Agency RDSO ) | Metre | 840.00 | 1,167 | 9,80,280 |
| 98 | Suply, Installation, Testing & Commissioning of LHS Interface Module with all accessories for single stretch, c o m p l y i n g to RDSO/SPN/217/2025 Ver 3.1 or latest. As per latest VDS approved/Listed. ( Inspection Agency RDSO ) | Numbers | 12.00 | 1,10,725 | 13,28,700 |
| 99 | Suply, Installation, Testing & Commissioning of Aspiration (Air Sampling Type) Detection unit complying to RDSO/SPN/217/2025 Ver 3.1 or latest. As per latest VDS approved/Listed. ( Inspection Agency RDSO ) | Numbers | 12.00 | 2,22,716 | 26,72,592 |
| 100 | Suply, Installation, Testing & Commissioning of CPVC pipe for Aspiration Detection system complying toRDSO/SPN/217/2025 Ver 3.1 or latest. As per latest VDS approved/Listed /approved by UL or FM or VDS or LPCB or tested with appropriate equivalent standard. ( Inspection Agency RDSO ) | Metre | 840.00 | 1,320 | 11,08,800 |
| 101 | Suply, Installation, Testing & Commissioning of Analogue Addressable loop powered Monitor Module with inbuilt isolator complying to RDSO/SPN/217/2025 Ver 3.1 or latest. As per latest VDS approved/Listed. ( Inspection Agency RDSO ) | Numbers | 12.00 | 7,151 | 85,812 |
| 102 | Suply, Installation, Testing & Commissioning of Analogue Addressable loop powered Control Module complying to RDSO/SPN/217/2025 Ver 3.1 or latest. ( Inspection Agency RDSO ) | Numbers | 12.00 | 7,151 | 85,812 |
| 103 | Suply, Testing & Commissioning of Hooter cum strobe complying to RDSO/SPN/217/2025 Ver 3.1 or latest. ( Inspection Agency RDSO ) | Numbers | 12.00 | 6,394 | 76,728 |
| 104 | Suply, Testing & Commissioning of 2C 1.5 sq mm twisted shielded armoured copper cable (Per Meter) with accessories complying to the RDSO/SPN/217/2025 Ver 3.1 or latest. ( Inspection Agency RDSO ) | Metre | 840.00 | 94 | 78,960 |
| 105 | S u p l y , Testing & Commissioning of Isolator Device to isolate the circuit in case of short circuit, complying to the RDSO/SPN/217/2025 Ver 3.1 or latest. ( Inspection Agency RDSO ) | Numbers | 12.00 | 3,071 | 36,852 |
| 106 | Supply of Permanently Lubricated HDPE Telecom duct of size 50/42 mm and accessories as per latest Specification TEC GR No. GR/TX/CDS-008/03March 11 with latest amendment" for OFC cable of size 24 fibre armoured in length of 1000 mtr/roll. Duct to be supplied from TEC approved sources. ( Inspection Agency RITES ) | Kilometre | 77.00 | 63,534 | 48,92,118 |
| Schedule total | ₹11,82,34,993.5 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderDocumentMATKWDABSWork_1.pdf
ATTACHMENT
1MADHASIP.pdf
ATTACHMENT
2VAKAVSIP_1.pdf
ATTACHMENT
3ANGARSIP_1.pdf
ATTACHMENT
4MALIKPETHSIP_1.pdf
ATTACHMENT
5MOHOLSIP_1.pdf
ATTACHMENT
6MUNDHEWADISIP_1.pdf
ATTACHMENT
7PAKNISIP_1.pdf
ATTACHMENT
8BALESIP_1.pdf
ATTACHMENT
9SolapurSIP_1.pdf
ATTACHMENT
10TIKEKARWADISIP_1.pdf
ATTACHMENT
11MADHAVAKAVROLLPLAN.pdf
ATTACHMENT
12VAKAVANGARROLLPLAN_1.pdf
ATTACHMENT
13ANGARMALIKPETHROLLPLAN_1.pdf
ATTACHMENT
14MALIKPETHMOHOLROLLPLAN_1.pdf
ATTACHMENT
15MOHOLMUNDHEWADIROLLPLAN_1.pdf
ATTACHMENT
16MUNDHEWADIPAKNIROLLPLAN_1.pdf
ATTACHMENT
17PAKNIBALEROLLPLAN_1.pdf
ATTACHMENT
18BALESURROLLPLAN_1.pdf
ATTACHMENT
19SURTKWDROLLPLAN_1.pdf
ATTACHMENT
20CRLYDRAWINGANNEXURESSORSnTOCT2025135_1.pdf
ATTACHMENT
21CRLYDRAWINGANNEXURESSORSnTOCT20253675_1.pdf
ATTACHMENT
22CRLYDRAWINGANNEXURESSORSnTOCT202576110_1.pdf
ATTACHMENT
23AutoHutDrawing_1.pdf
ATTACHMENT
24ABSpolicyRailwayBoarddated23042024_1.pdf
ATTACHMENT
25CRpolicySMSgenerationforEIfailure_1.pdf
ATTACHMENT
26CRpolicySystemImprovementforEInewworks_1.pdf
ATTACHMENT
27Procedureofundertakingofdiggingworkofcable_1.pdf
ATTACHMENT
28Civilcirculars_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].