Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.9 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹36.0 L+₹1.1 L (3.16%)Rejected-AOC | L2 | Rejected-AOC Rejected due to not being L1 | |
| 3 | L3₹41.6 L+₹6.7 L (19.1%)Rejected-AOC HOUSE NO 93 WARD NO 8 NEAR ISKON TEMPLE UDHAMPUR J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-AOC Rejected due to not being L1 | |
| 4 | L4₹43.2 L+₹8.3 L (23.8%)Rejected-AOC 21 JHAMRI 151 JHAMRI JHAMRI ROHTAK HARYANA 124142 UDYAM HR 07 0030314 | JHAJJAR | HARYANA | 124142 | L4 | Rejected-AOC Rejected due to not being L1 |
Tender Value
Refer Docs
EMD Value
₹93,800
Closing Date
29 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NORTH UDHAMPUR
GE NORTH UDHAMPUR
GE U(N) 29 2023 24 REPAIR MAINT CLEANING OF SEWAGE LINE SEPTIC TANK AND CONNECTED ITEMS FOR OTM MD ACCN AT HQ SUB AREA TRANSIT CAMP AND ADJOINING AREA UNDER AGE BR 1 OF GE (N ) UDHAMPUR
2023_MES_600911_1
GE/U(N)-29 2023-24
Open Tender
Civil Works
Item Rate
330 days
GE NORTH UDHAMPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NORTH UDHAMPUR
₹93,800
Yes
4 Aug 2023
3 Jun 2023
1 Jul 2023
3 Jun 2023
29 Jun 2023
16 Jun 2023
Amount
M&L for systematically cleaning of the water closer including nahani trap, floor trap and gully traps by bamboo/wire/kandi rotary cleaner up to first mainhole any type of dia complete all as specified and directed by Engr in charge Note : The contractor or his authorised rep shall collect the complaint of all blockage of sewage from complaint cell /Engr-in-charge daily and all complaint will be rectified by the contractor with in same day than the returned the complaint slip after completion of complaint and get recipt from concered JE/Enge-in-charge .If he fails to complete the work with in same day then recovery will be made @150.00 per complaint per day .
M&L for systematically cleaning of the sewage lines including gully traps by passing ropes, Knots, bamboo/wire/kandi rotary cleaner etc for any type of dia of sewage pipe, complete all as specified and directed by Engr in charge
M&L for cleaning and desludging of manholes of any size, shape and any depth including pumping out liquid waste if any, removing all solid waste materials such as stones, bricks, pipes, plastic etc, pluggings/ diverting of flow if required and removing the debries outside MOD land as aothorized by the local municipal corporation with proper goverment reciept etc including all precautionary and safty measures all as directed.
M&L for cleaning and desludging of existing mini septic tank of capacity n exc 10 Users and including inlet and outlet chambers and soakage well, taking out sludge in any form alongwith all other foreign materials by mechanical equipment or by way of other suitable means , and removing waste material/sludge ( desludging n exc 0.5 cum and dewatering n exc 0.5 cum from each septic tank) outside MOD land as aothorized by the local municipal corporation with proper goverment reciept Complete all as specified.and as directed, Note :-(i) Work shall be done in foul conditions , necessary precautionary measures/equipments to be adopted by the contractor . (ii) The solid or semi solid sludge shall remove outside MOD land as aothorized by the local municipal corporation with proper goverment reciept (iii) Rates quoted by the contractor shall be deemed to have considered all such contingencies including removal and refixing man hole covers. (iv) Any damage caused during cleaning shall be made good by the contractor to the entire satisfaction of Engr-in-Charge without any extra cost to Govt.
Same as item No. 4 above but 100 users capacity ( desludging n exc 12.0 cum and dewatering n exc 12 cum from each septic tank) complete all as specified and directed by Engr in charge
Same as item No. 4 above but 50 users capacity ( desludging n exc 6.0 cum and dewatering n exc 6 cum from each septic tank) complete all as specified.
Same as item No. 4 above but 25 users capacity ( desludging n exc 4.0 cum and dewatering n exc 4 cum from each septic tank) complete all as specified.
M&L for excavation in trenches in hard/dense soil not exceeding 1.50m wide and not exceeding 1.50m in depth for foundation etc or for shafts, manholes, pier holes etc n.exc 10 sqm on plan and not exc 1.50m in depth and getting out in any type of soil, complete all as specified and directed by Engr in charge
Ditto all as above item but as in soft/ disintegrated rock complete all as specified and directed by Engr in charge
S & F HDPE DWC (Double wall corrugated) pipes confirming to IS-16098, of 170mm internal dia, presure rating SN-8 fixed with rubber seal and coupler required with and including suitable bends 90/60/45 degree etc single Y junction, complete as required fixed as per manufacturer instruction laid in trenches for sewage lines including dismantling all as specified and as directed. Note :- (i)Rates included for pipe, bends any size and type, Y Jn coupler /adaptor etc required and net total length of pipe with fittings shall be measured for payment purpose.(ii) Contractor shall submit the test certificate and purchase vouchers before applying for payement .
M&L for 150 mm Reinforced concrete pipes, class NP2, laid and jointed including dismantling including dismantling complete with collars complete all as specified and directed by Engr in charge
M&L for 200 mm dia Reinforced concrete pipes class NP2, laid and jointed including dismantling completed with collar complete all as specified and directed by Engr in charge
M&L for 300 mm dia Reinforced concrete pipes class NP2, laid and jointed including dismantling completed with collar complete all as specified and directed by Engr in charge
M&L for cement concrete in 1:4:8 type D-2 (using 40 mm graded stone aggregate) in foundation bed for laying of sewage lines or mass concrete, complete all as specified and directed by Engr in charge
M&L for returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed by Engr in charge
M&L for removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting pointcomplete all as specified and directed by Engr in charge
M&L for dismantling/ taking out of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches/wall upto & incl of internal dia of pipe 100/75 mm, all as specified and directed by the Engr-in-charge.
S&F 100 mm dia Cast iron Sand soil pipes, waste and vent pipes in any length with or without ears with cement joints, laid in trenches or in floors all specified and directed by the Engr-in-charge.
S&F 100 mm dia Cast iron Sand pipes, waste and vent pipes, in any length with or without ears with cement joints, fixed to wall with MS clamps all specified and directed by the Engr-in-charge.
All as per Sl. item No. above but refixing only (except pipe) with stack clamp, etc, complete all as specified and directed by Engr in charge
S&F 75 mm dia iron sand cast pipes, waste and vent pipes, in any length with or without ears with cement joints, fixed to wall with MS clamps all specified and directed by the Engr-in-charge.
All as per Sl. item No.21 above but refixing only (except pipe) with stack clamp, etc, complete all as specified and directed by Engr in charge
S&F in repairs CI sand cast 100mm bore bends/reducer/Tee (any radius) with access door diminishing pieces or tapers (larger bore measured) all as specified all specified and directed by the Engr-in-charge.
All as per srl item No. 23 above but 75mm bore, complete all as specified and directed by Engr in charge
S&F in repairs CI sand cast 100mm bore Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches all as specified all specified and directed by the Engr-in-charge.
All as per srl item No.25 above but 75mm bore, complete all as specified and directed by Engr in charge
S&F 100 mm bore CI vent cowl including taking down old CI vent cowl of any type complete all as specified and directed by Engr in charge
Ditto all as Item No.27 above but 75mm.
Cast iron eye plate with rubber washer suitabble for 75/100mm bore bends/tee, etc where required, complete all as specified and directed by Engr in charge
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends swan necks, etc, including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fitting and accessories). complete all as specified and directed by Engr in charge
S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with MS clamps, all as specified and directed by the Engr-in-charge.
All as per Srl item No.31 above but as in refixing only with stack clamp to wall complete all as specified and directed by Engr in charge
S&F110 mm bore PVC (SWR) bends with access door any radius, all as specified and directed by the Engr-in-charge.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water complete, all as specified and directed by the Engr-in-charge.
M&L for 15 mm thick cement plaster on the fair face of brick or concrete surface in cement mortar 1:4 finished even and smooth without using extra cement,all as specified and directed by the Engr-in-charge.
Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillar etc but excluding ashlar facing , dressed stone work and precast concrete articles, complete all as specified and as directed. .
M&L for brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 metre mean radius, using old size bricks, built in cement mortar 1:6 , complete all as specified and directed by Engr in charge
All as per item No. 37 herein before, but except bricks. Note-Old bricks obtained against dismantling shall be used.
M&L for Walling of random rubble, uncursed, well bonded, bedded and solidly hearted, built in cement mortar 1:4complete all as specified and directed by Engr in charge
All as per Srl item.39 above here n before but except stone.
M&L for Flush pointing to random rubble, uncoursed on brought upto course on masonry or concrete block walling in cement mortar 1:4complete all as specified and directed by Engr in charge
M&L for 50 mm thick, PCC 1:3:6 type C1 (using 20mm graded stone aggregate) in plinth protection finished even & smooth with out using extra cement including making joints 10mm wide and 30mm deep at spacing not more than 2.5m and at corners as mandatory and filled with sealing compound grade A complete all as specified and directed by Engr in charge
M&L for Providing cement concrete 1:3:6 type C-1 ( Using 20 mm graded crushed stone aggregate ) as in coping, Gola etc including necessary formwork as requiredcomplete all as specified and directed by Engr in charge
M&L for Cement concrete 1:2:4 type B-0 ( Using 12.5 mm graded crushed stone aggregate ) as in surface channel or drain including necessary form work etc,complete all as specified and directed by Engr in charge
M & L pre-cast RCC 1 : 2 : 4, type B-1 (using 20 mm graded stone aggregate) in cover slabs for man holes with plain faces finished fair and smooth etc, set in CM I : 6 and including necessary formwork if required incl. demolition of old slabs complete all as specified and directed by Engr in charge
M&L for MS TMT bars 8 mm dia and over as in reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engr in charge
Demolition of cement concrete (un reinforced) in ground floor and paving n/exe 15 cm thickness (below or above ground level) complete all as specified and directed by Engr in charge
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engr in charge
Demolition of stone slabs and tiles laid bedded and jointed and pointe inn any mortor of any description or thickness in floors,aprons etc. complete all as specified and directed by Engr in charge
M&L for chequered Reflective vitrified tiles 30cmx30cmx10mm thick coloured with grey cement & admixtures laid over 15mm thick cement mortar 1:4 set, jointed and pointed in neat cement slurry in floors, complete all as specified and directed by Engr in charge
M&L for machine pressed rubber moulded manufactured/compacted by vibrating table method pre-cast concrete interlocking paver block Laquor finish any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and pigment and joints filled with sand complete all as specified and directed by Engr in charge
M&L for machine pressed rubber moulded manufactured/compacted by vibrating table method pre-cast concrete interlocking paver block Laquor finish any shape and size confirming to IS 15658-2006 of 80mm thickness, M-40 grade with grey cement and pigment and joints filled with sand complete all as specified and directed by Engr in charge
M&L for refixing of interlocking tiles of 50/60mm thick laid dry in position over sand cushioning including dismantling of existing tiles, complete all as specified and directed by Engr in charge
Refixing of interlocking tiles of 80mm thick laid dry in position over sand cushioning including dismantling of existing tiles, complete all as specified and directed by Engr in charge
M & L for Sand filling under floors or in foundations including watering and consolidation, complete all as specified and directed by Engr in charge
M&L for 75mm thick PCC 1:4:8 type D1 (using 20mm graded stone aggregate) as in Sub base complete all as specified and directed by Engr in charge
M&L for providing and laying water proofing treatment to sunken portion of WCs, bathrooms, etc by applying first layer of slurry of cement @ 0.488kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @ 0.253kg/sqm this layer allowed to air cure for 4 hrs then applying slurry of cement @ 0.242 kg/sqm mixed with acrylic based polymer modified cementitious composite compound @0.126kg/sqm and allowed to aircure for 4 hrs and joints seal with sealing compound as approved by GE. Note: (i) Before laying of lime concrete joints of trap/WC/Soil pipes shall be properly sealed with sealing compound of Roofex/Forre/FOSROC and provn of P or S trap & Nahani /Floor traps with long arm.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in Cement mortot as in CM 1:3 finishing even & smooth w/o using extra cement, complete all as specified and directed by Engr in charge
M&L for lean concrete using 40mm graded stone aggregate as in 1:5:10 as in sunken portion treatment, complete all as specified and directed by Engr in charge
M&L for vitreous china squalting pan, orissa pattern size 580 x 440 mm white with integral foot rest, P or S trap long body with integral foot rest and fixed with cement concrete bedding complete all as per specified. (Fixed in Repair). Make-CERA, Cat part No. 2071, Jaquar –CNS-WHT-OP01 or equivalent of any approved make as approved by GE.
M & L for PVC 'Q' trap 110mm bore, ISI marked including proper jointing to existing sewage lines, complete all as specified and directed by Engr in charge
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (sqare/ rectanglear) area of each tile exc 0.11sqm but n exc 0.18 sqm in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 10mm thick screed bed in Cement mortar (1:4) complete all as specified and directed by Engr in charge
M&L for glazed ceramic coloured digital tiles in vertical surfaces of wall of size 450mm x 300mm x 7 mm thick as approved pattern approved by GE, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm thick rendering in Cement mortar 1:3 as in skirting, dado, etc, complete all as specified and directed by Engr in charge
M&L for 25mm thick PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in floor base of tiles complete all as specified and directed by Engr in charge
M&L for dismantling of floor hearth or wall tiling incl CM, bedding (but not backing) and rubbish off the premises complete all as specified and directed by Engr in charge
M&L for prepration of new plaster surfaces of wall and applying two coats of cement based paint over a coat of alkali resistant cement base primer on wall surfaces complete all as specified and directed by Engr in charge
M&L for cutting into existing manhole for connecting new drain pipes of 150 mm internal dia, making good to pipes and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished, and reforming benching all as specified and as directed.
M&L for dismantling of structural steel work in any description complete all as specified and directed by Engr in charge
M&L for mild steel framed work for grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed by Engr in charge
sohtra and co
khajuria builders
KUMAR CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .