Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC OLD DAILY MARKET DIMAPUR 797 112 NAGALAND | PEREN | NAGALAND | 797112 | L1 | Accepted-AOC Reasonable rate | |
| 2 | L2₹16.0 L+₹60,418.75 (3.92%)Rejected-Finance | L2 | Rejected-Finance Quoted amount higher than L1 | |
| 3 | L3₹16.1 L+₹69,308.12 (4.50%)Rejected-Finance | L3 | Rejected-Finance Quoted amount higher than L1 | |
| 4 | L4₹16.2 L+₹81,698 (5.30%)Rejected-Finance | L4 | Rejected-Finance Quoted amount higher than L1 | |
| 5 | L5₹16.5 L+₹1.1 L (7.07%)Rejected-Finance | L5 | Rejected-Finance Quoted amount higher than L1 |
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
1 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col N K Chaudhary
HQ 137 WKS ENGR PIN 914137 CO 99 APO
SPL REPAIR TO BLDG NO T 218 AT ZAKHAMA MIL STN
2023_MES_589234_2
8762/E8
Open Tender
Civil Works
Item Rate
180 days
Zakhama
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
AGE (I) Zakhama
₹29,000
Yes
14 Aug 2023
10 Jun 2023
8 Jul 2023
10 Jun 2023
1 Jul 2023
17 Jun 2023
Amount
Demolition of Concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
Material and labour for hardcore of broken stone or boulder of gauge n.exc 63mm, deposited, spread and leveled in layers n.exc 15cm thick, watered and rammed to a true surface complete all as specified and as directed.
Material & Labour for 75mm thick, PCC 1:4:8, Type D-2, using 40mm graded aggregate as in sub base etc. surface finished even and fair without using extra cement complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding, (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Material & Labour for joint free non skid ceramic coloured tiles 7 to 8mm thick (square /rectangular) of premium quality, area of each tile exceeding 0.18 sqm but not exc 0.38sqm in floors etc. set & jointed in neat cement slurry & pointed in white or coloured cement to match including screed bed of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by AGE(I).
Material & Labour for joint free non skid ceramic coloured tiles 7 to 8mm thick (square /rectangular) of premium quality, area of each tile exceeding 0.18 sqm but not exc 0.38sqm as in skirting/dado, set & jointed in neat cement slurry & pointed with white/coloured to match over and including rendering of 10mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by AGE(I).
Taking down cement plaster of any description built in cement mortar on brick or stone walls etc including raking out joints, hacking for Key, scrubbing down with water etc. complete all as specified and as directed.
Material and labour for 15mm thick rendering in CM (1:4) on brick work or concrete surface as on wall mixed with integral water proofing compound @ 2% by wt of cement, finished the surface even and fair complete all as specified and directed. (Note:Water proofing compound shall be measured & paid separately)
Supply only integral water proofing compound (WPC) of best quality (ISI marked) complete all as specified and as directed.
Materials and labour for 15 mm thick rendering on other than fair faces of brick work or concrete surface as on wall in cement mortar (1:6) and finished the surfaces even and smooth without using extra cement complete all as specified and as directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including similar pattern roof covering complete all as specified and as directed.
Dismantling of Mild Steel or Wrought Iron Work of any description not otherwise provided for complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards / slabs / blankets any thickness including cover fillets complete all as specified and as directed.
Material and labour for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Material and labour for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as complete all as specified and as directed.
Supply and fixing in repairs suspended false ceiling using E-grid 2430 180 GSM (exposed ceiling suspension system) of grid size 600mm x 600mm with main runner 38mm x 24 mm and wall angle 24mm x 24 mm using 4 mm thick High Pressure Non asbestos Fibre Cement pre painted decorative board (E-board Classic) in a grid of GI system duly suspended with 4 mm dia GI bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing position for light fixtures, air conditioning diffusers and ducts, sprinkler, smoke detectors etc. The main runner to be secured to structural soffit by hangers @ 1220 mm maximum c/c. The last hanger at the end of each main runner should not be placed at more than 450 mm from the adjascent wall, Flush fitting 1220 mm cross Tee to be interlocked between main runners @ 610 mm c/c so as to form 600mm x 600mm grid complete all as specified and as directed.
Supply and fixing plain galvanised mild steel sheeting of 0.63mm thick in stepped flashings (measured as the minimum rectangle from which the pieces can be cut) and fixed with nails complete all as specified and as directed.
Supply and fixing in repairs 4 mm thick,Plywood, grade BWR, type BB, fixed with nails to timber frame work complete all as specified and as directed.
Dismantling timber scantling 40 Sqcm and over in section, unframed work in any position complete all as specified and as directed.
Material and labour for Timber framed and fixed clean sawn 2nd class hard-wood in scantling fixed complete all as specified and as directed.
Material & Labour for two coats of Synthetic Enamel paint over one coat of Red Oxide Primer on new steel surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed.
Material and labour for preparation of new wooden surface exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Material and labour for preparation of old decorated wooden surfaces over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Material and labour for preparation of old decorated steel surfaces over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Material and labour for preparation of newly plastered surface of ceiling and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed.
Material and labour for preparation of newly plastered wall surfaces and applying two coats of Cement Based paint over a coat of Alkali Resistant Primer complete all as specified and as directed.
Supply and fixing Rolled mild steel joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming to Fe 410-W (Gde-E- 250) quality- A etc complete all as specified and as directed .
Fixing only Rolled mild steel joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming to Fe 410-W (Gde-E- 250) quality- A etc complete all as specified and as directed .
Taking down shutters of any description not exc 1.00 Sqm each complete all as specified and as directed.
Taking down shutters of any description exc 1.00 Sqm but n. exc. 2.00 Sqm each complete all as specified and as directed.
Supply & Fixing 30mm thick, Second Class Hard Wood, Glazed and Skeleton Shutters, open rebated and prepared to receive glass, gauze, etc., divided into squares, with plain, chamfered or rounded, mitred and rebated Sash Bars, any numbers, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part – I, Section 8, Clause 8.24 [b] and fitted to Chowkats complete all as specified and as directed.
Supply and fixing 100 mm size, medium weight Butt Hinges, cold rolled, mild steel including fixtures complete all as specified and as directed.
Supply and fixing 75 mm size, medium weight Butt Hinges, cold rolled, mild steel including fixtures complete all as specified and as directed.
Supply and fixing 250mm long Aluminium alloy, anodised, sliding door bolt with hasp staple (Bolt type) and fixing clips of sheet, cast or extruded section or cast aluminium alloy and fixed complete all as specified and as directed.
Supply and fixing in repair Floor Door Stopper of size 140 mm of aluminium alloy body and tongue, anodised, with hard drawn steel spring complete all as specified and as directed.
Supply and fixing Aluminium anodised barrel tower bolt of extruded section and fixed 150 mm long complete all as specified and as directed.
Supply and fixing Aluminium anodised barrel tower bolt of extruded section and fixed 100 mm long complete all as specified and as directed.
Supply and fixing extruded aluminium alloy handles, fabricated type, anodised 150mm size complete all as specified and as directed.
Supply and fixing extruded aluminium alloy handles,fabricated type, anodised 100mm size complete all as specified and as directed.
Supply and fixing 3 mm thick sheet glass ordinary quality & glazing with oil putty, glazing pin etc in squares n. exe 0.5 sqm in each pane complete all as specified and as directed.
Supply & fixing Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed.
Material & Labour for 75mm thick, PCC 1:3:6, Type C-1, using 20mm graded aggregate as in Plinth protection etc surface finished even and smooth without using extra cement and providing necessary joints 12mm wide to the full depth of PCC at every 3 meters and every change of directions and the joints duly filled with mastic filling comprising of 01 Part of heated bitumen blown grade any penetration and 3 parts of sand [all by weight] complete all as specified and as directed.
M & L for PCC 1:4:8, Type D-2, using 40mm graded stone aggregate as in Foundation, Fillings, Mass concrete, Footings etc complete all as specified and as directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quions, arches, pillers etc complete all as specified and as directed.
Material and labour for brick work with sub class `B` bricks, old size, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and as directed.
Material & labour for walling of random rubble masonry, uncoursed, well bonded, bedded and solidly hearted for retaining wall, abutments and similar work, built in Cement Mortar 1:6 complete all as specified and directed.
All as per serial item No. 46 but except stone complete all as specified and directed.
Material & labour for providing precast cement concrete 1:2:4, Type B1, using 20mm graded stone aggregate as in window or door Cills, lintels, bressummers, steps, quoin blocks [for use with masonry], string courses, copings. kneelers, apex stones, pier caps, columns, posts,bond stone boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders [for stone walling], corbels, brackets, etc. [of any section indicated], with plain fair faces, including chamfers, weatherings, throating etc. and setting in mortar 1:4 complete with joints to match complete all as specified and as directed.
Material & labour for Plain cement concrete Type B0 [Nominal Mix] 1:2:4 using 12.5mm graded stone aggregate cast in situ in lintels up to 1.5m span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates including weathering, slightly rounded or chamfered angles and throating as directed including use and waste of form work, complete all as specified and as directed.
Material & labour for Extra over sand or lime stone walling for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling,uncoursed or brought face from straight edge held against the dressed surface not exceeding 20mm complete all as specified and directed.
Material & labour for Raised Pointing in Cement Mortar 1:3 to random rubble uncoursed or brought up to coursed masonry complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.etc complete all as specified and directed.
Material and labour for point wiring (surface type) for one light/fan/call bell point with 1.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC casing caping of suitable size with all accessories and PVC rectangular boxes for mounting switch, socket and fan regulator etc complete all as specified and as directed. Note: (i) Wiring shall be done in proper colour coding using red , yellow, blue for phase, black for neutral and green for earth. (ii) The cost of making good the disturbed surfaces is deemed to be included in the quoted rate.
All as per item no 53 here in before but for one 3 pin 15 Amps switch socket combination on independent board with 2.5 sqmm PVC (FR-LSH) insulated un-sheathed copper conductor cable multistranded conductor 1100 volts grade and 2.5 Sqmm PVC (FR-LSH) copper conductor cable as earth continuity conductor.
All as per item No 53 above but for 3 pin, 5 Amp Socket outlet on the same board complete all as specified and directed.
All as per item No 53 above but for 3 pin,5 Amp switch Socket combination on independent board complete all as specified and directed.
Supply & fixing Socket outlet 2 in 1, 3 pin, 5A flush type universal complete all as specified & as directed.
Supply & fixing Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified & as directed.
Supply & fixing Switch socket combination 2 in 1, 3 pin, 5 Amp flush type universal complete all as specified & as directed.
Supply & fixing switch piano flush type, single pole, one way 5 Amp, 240 Volts complete all as specified & directed.
Supply and fixing ceiling rose, PVC/polycarbonate, isolated body surface bakelite, 62.5mm x 50mm, ISI marked three terminals complete all as specified & directed.
Supply and fixing in repairs Surface & wall mounted Energy efficient LED Tube Light Fitting, of 20 W, 6500 K of cool white, with extruded aluminium / CRCA housing and robust construction with necessary acrylic diffuser & integrated electronic driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
Supply and fixing PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 200 mm x 150 mm and 50 mm deep complete all as specified and as directed.
Supply & Fixing MCB DB, SPN, 8 Way, 240 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs flush mounted with wall including taking down of existing unserviceable DB with MCBs including making good disturbed surfaces complete all as specified and as directed.
Supply & Fixing MCB SPN having braking capacity 10 KA, 32 Amp, 240 Volt 'B' Curve complete all as specified and directed.
Supply and fixing MCB, single pole having braking capacity 10 KA, 6 to 32 Amp, 240 volts, 'B' Curve complete all as specified & directed. Note for serial Item No. 64 to 66: MCB and MCB DB shall be of same make as approved by AGE (I).
Material & Labour for sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 6.0 sqmm (Nominal area) drawn through in and including PVC Casing/ Caping with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 6.0 sqmm as earth lead and connected to earth dolly and including taking down old unserviceable sub main wiring of any description, making good to disturbed surfaces complete all as specified as directed. Note : (i) 3 Runs of 6.0 Sqmm cable and one run of PVC Casing/ Caping shall be measured as one unit length.
Supply and fixing 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor of size 16 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular including taking down old unserviceable cable complete all as specified and as directed.
Material and Labour for House service bracket (hook type complete with 3.0m long G.I. pipe 40mm dia Medium grade, two nos. 90 degree bends, M.S. hook and stay or guy including dismantling of existing old unserviceable house service brackets, any type complete all as specified and as directed.
Supply & fixing in repairs of RCBO-A type (SPN-2M) of rating 32 Amps, short circuit breaking capacity of 10 KA and sensitivity of 30mA, IP-20 protection, conforming to IEC 61009-2, IS 12640-2 complete all as specified and as directed.
Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised wire of 4mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking down old unserviciable earthing set all as specified and as directed. Notes:- (i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department.
M/S SANGITA TRADERS
commercial enterprises
Rameshwar Prasad
M/S VIKASH TRADERS
Shri B K Ukil
Kalim sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .