Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.3 LAccepted-AOC | ₹38.3 L Quoted ₹40.7 L | L1 | Accepted-AOC Being L1 bidder |
| 2 | L2₹52.5 L+₹11.8 L (29.0%)Rejected-Finance DHOBI MOHALLA BATMALOO SRINAGAR 190010 J K | SRINAGAR | SRINAGAR | J K | 190010 | ₹52.5 L+₹11.8 L (29.0%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹56.9 L+₹16.2 L (39.8%)Rejected-Finance R O IQBAL MARKET AALI MAJID EIDGAH SRINAGAR KASHMIR | SRINAGAR | JAMMU AND KASHMIR | 190001 | ₹56.9 L+₹16.2 L (39.8%) | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹57.4 L+₹16.6 L (40.9%)Rejected-Finance | ₹57.4 L+₹16.6 L (40.9%) | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹61.9 L+₹21.2 L (52.1%)Rejected-Finance | ₹61.9 L+₹21.2 L (52.1%) | L5 | Rejected-Finance Not being L1 |
Tender Value
Refer Docs
EMD Value
₹94,000
Closing Date
4 Jun 2021, 6:00 pmClosed
CWE, HQ 133 WORKS ENGRS
HQ 133 WORKS ENGRS PIN-914133 C/O 56 APO
REPAIR MAINT OF STANDBY DG SETS AND CONNECTED ACCESSORIES AT ZANGLI DURGMULLA TANGDHAR CHOWKIBAL NIYARI TREHGAM PATAHIRI PANZGAM BANDIPUR AND DAWAR UNDER GE 874 EWS
2021_MES_440749_1
CWEK-16/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 874 EWS
Class D Category b i
7 documents required · 7 mandatory
₹500
GE 874 EWS
₹94,000
Yes
HQ 133 WORKS ENGRS
20 Aug 2021
6 May 2021
7 Jun 2021
6 May 2021
4 Jun 2021
21 May 2021
6 May 2021 - 13 May 2021
15 May 2021
Amount
Material and Labour for Disconnecting, taking out and opening of DG set 250/200 KVA by unscrewing nuts, bolts and servicing of DG set with checking of lubricating oil, coolant, V belt, greasing and oiling of parts and topping up necessary oils, cleaning the inner body, tank and radiator by removing sludge etc and reassembling the DG set after repair/replacement of unserviceable parts of DG set and testing complete all as specified and directed. installed at different location of AOR. (Note :- Cost of spares/parts mentioned below will be measured and paid seprately as supply only under respective items mentioned here-in-below. However other minor consumables and spares are included).
Supply Only of Fuel filter of DG set 250/200 KVA complete all as specified and directed.
Supply Only of Lube oil filter of DG set 250/200 KVA complete all as specified and directed.
Supply Only of Air filter of DG set 250/200 KVA complete all as specified and directed.
Supply Only of Cooper washer of DG set 250/200 KVA complete all as specified and directed.
Supply Only of Banjo bolt of DG set 250/200 KVA complete all as specified and directed.
Supply Only of Fuel pipe of DG set 250/200 KVA complete all as specified and directed.
Supply Only of Hose water pipe for radiator of DG set 250/200 KVA complete all as specified and directed.
Supply Only of Warm drive H/clip of DG set 250/200 KVA complete all as specified and directed.
Supply Only of V-belt of DG set 250/200 KVA complete all as specified and directed.
Material and Labour for Disconnecting, taking out and opening of DG set 125/ 100 KVA by unscrewing nuts, bolts and servicing of DG set with checking of lubricating oil, coolant, V belt, greasing and oiling of parts and topping up necessary oils, cleaning the inner body, tank and radiator by removing sludge etc and reassembling the DG set after repair/replacement of unserviceable parts of DG set and testing complete all as specified and directed. installed at different location of AOR. (Note :- Cost of spares/parts mentioned below will be measured and paid seprately as supply only under respective items mentioned here-in-below. However other minor consumables and spares are included).
Supply Only of Fuel filter of DG set 125/ 100 kVA complete all as specified and directed.
Supply Only of Lube oil filter of DG set 125/ 100 kVA complete all as specified and directed.
Supply Only of Air filter of DG set 125/ 100 kVA complete all as specified and directed.
Supply Only of Cooper washer of DG set 125/ 100 kVA complete all as specified and directed.
Supply Only of Banjo bolt of DG set 125/ 100 kVA complete all as specified and directed.
Supply Only of Fuel pipe of DG set 125/ 100 kVA complete all as specified and directed.
Supply Only of Hose water pipe for radiator of DG set 125/ 100 kVA complete all as specified and directed.
Supply Only of Warm drive H/clip of DG set 125/ 100 kVA complete all as specified and directed.
Supply Only of V-belt of DG set 125/ 100 kVA complete all as specified and directed.
Material and Labour for Disconnecting, taking out and opening of DG set 82.5 KVA by unscrewing nuts, bolts and servicing of DG set with checking of lubricating oil, coolant, V belt, greasing and oiling of parts and topping up necessary oils, cleaning the inner body, tank and radiator by removing sludge etc and reassembling the DG set after repair/replacement of unserviceable parts of DG set and testing complete all as specified and directed. installed at different location of AOR. (Note :- Cost of spares/parts mentioned below will be measured and paid seprately as supply only under respective items mentioned here-in-below. However other minor consumables and spares are included).
Supply Only of Fuel filter of DG set 82.5 kVA complete all as specified and directed.
Supply Only of Lube oil filter of DG set 82.5 kVA complete all as specified and directed.
Supply Only of Air filter of DG set 82.5 kVA complete all as specified and directed.
Supply Only of Cooper washer of DG set 82.5 kVA complete all as specified and directed.
Supply Only of Banjo bolt of DG set 82.5 kVA complete all as specified and directed.
Supply Only of Fuel pipe of DG set 82.5 kVA complete all as specified and directed.
Supply Only of Hose water pipe for radiator of DG set 82.5 kVA complete all as specified and directed.
Supply Only of Warm drive H/clip of DG set 82.5 kVA complete all as specified and directed.
Supply Only of V-belt of DG set 82.5 kVA complete all as specified and directed.
Material and Labour for Overhaul of DG Set to include disconnecting, taking out and opening of DG set, head job of 125 KVA gen set etc and reassembling the DG set after repair/replacement of unserviceable parts of DG set, any machining works (such as grinding, milling, Lathe and other jobs), any other job to make the DG Set operational and testing complete all as specified and directed. (The DG Set should be provided with an all inclusive warranty period of 365 days (of running time) from the date of making the DG set operational. Any off road period during this warranty time will sufficiently enhance the warranty duration) (Note :- Cost of spares/ parts/ jobs mentioned below will be measured and paid seprately as supply only under respective items mentioned here-in-below. However other minor consumables, spares and jobs are included).
Head facing/Grinding Job
Supply Only of Inlet/Exhaust Valve
Supply Only of Oil Valve Seal
Supply Only of Valve Spring
Supply Only of Valve Guide
Supply Only of Valve seat Inlet/Exhaust
F.I.P Calbiration, cleaning and repair Job (125 kVA DG Set)
Injector Nozzel
Supply Only of Began
Supply Only of Linear
Supply Only of Piston
Supply Only of Ring Set
Supply Only of Main Began Bearing
Supply Only of Connecting Rod Bush
Supply Only of Cylinder Rubber Kit
Supply Only of Hose Kit
Supply Only of Benjo
Supply Only of Non Return Valve (NRV)
Supply Only of Fevibond/ epoxy/ cyanoacrylate, as required for complete overhaul of the DG Set
Supply Only of Battery Charger (smart, fast charging type, with both DC and AC inputs)
Supply Only of Battery Terminals
Supply Only of Head Guide
Supply Only of Water Pump
Dynamo Repair Job
Self Starter Repair Job
Supply Only of Starter Switch 24v
Supply Only of Feed Pump
Supply Only of AVR
Supply Only of Head Gasket
Supply Only of Belt Small
Supply Only of Belt Large
Supply Only of Rocker Set/ assembly
Supply Only of Turbo Drain Pipe
Supply Only of Packing Kit, complete for the overhaul
Supply Only of Fuel Pipe
Supply Only of House Connection
Supply Only of Copper Washers
Connecting Rod alignment Job, including any stores required for replacement
Supply Only of Connecting Rod
Transportation required to work site and back/ for shifting of DG Set from one location to another
Taking down the radiator complete of 82.5 to 200 KVA DG set from its mounting and descaling the same including cleaning from top and bottom of the tank and brazing re-soldering complete tank and re-installing the same to its original position all as directed by Engr-in-Charge.
Disconnecting the engine from alternator of DG set of any capacity after disconnecting all electrical connections, disassembling the alternator to carry out the rewinding of armature and rewinding of field coils and armature, including transportation of alternator to workshop and bringing back to site for re-assembling after repairs, re-installation at site and reconnecting alternator with engine including testing on load complete all as directed and specified by Engineer-in-charge including replacement of the following worn out spare parts:- (i) Carbon bushing and brush holder (set of 04) - 01 Set (ii) Field excitation coils - 04 Nos (iii) Rewinding of armature and current transformer - 01 No Note : The measurement is for kgs of copper used for winding only. The copper shall be suitably insulated and baked in an oven
Repair/ Complete Overhaul to self starter assembly of DG set of capacity of 100 to 125 KVA by cutting of old burnt winding with new copper winding wire as per existing size/ guage including insulation materials, varnishing and heating/ drying up jobs etc complete all as specified and directed. (for capacities of 200 kVA to 250 kVA, two quantities of same item schedule will be paid against one quantity overhauled)
Supply and fixing in repair off load changeover switch AC 23 side handle 4 pole, 415 volt 200 AMP complete all as specified and directed
Supply and fix in repair off load changeover switch AC 23 side handle 4 pole, 415 volt 320 AMP complete all as specified and directed
Supply and fix aluminium lugs of size 50 mm sqmm complete all as specfied and directed.
Supply and fix aluminium lugs of size 70 mm sqmm complete all as specfied and directed.
Supply and fix aluminium lugs of size 120 mm sqmm complete all as specfied and directed.
Supply and fix aluminium lugs of size 185 mm sqmm complete all as specfied and directed.
Supply and fix aluminium lugs of size 240 mm sqmm complete all as specfied and directed.
S&F battery lead wire as per existing size and length, flexible copper conductor single core including taking out old unserviceable battery lead wire complete all as specified and directed.
S&F battery terminal brass complete with GI nuts & bolts including taking out old unserviceable battery terminal brass complete all as specified and directed.
Overhauling, repairing and replacement of worn out parts of FIP, calibration and testing of fuel pump of 100 to 250 KVA DG set and testing on test bench and replacement of pump element, delivery valve, ball bearing and adjustment of injectors and setting of fuel pressure as per manufacturer instructions complete all as directed by the Engr-in-charge.
Overhauling, repairing and replacement of worn out parts of FIP, calibration and testing of fuel pump of 50 KVA to 100KVA DG set and testing on test bench and replacement of pump element, delivery valve, ball bearing and adjustment of injectors and setting of fuel pressure as per manufacturer instructions complete all as directed by the Engr-in-charge.
Supply only distilled water, for battery top up, in one/ five litre packaging, complete all as specified and directed by engineer in charge
Supply only of Smart Battery Charger, with dual battery charging feature and DC and AV input features, 150 to 290V AC input, 12V 12 Ampere DC output, with trickle charging and battery repair features, reverse polarity, overcurrent and over voltage safeguards, digital multicolour LCD display, with necessary adapters including crodile pin adapters, all as specified, directed, clarified and approved by engineer in charge
Supply only of Smart Battery Charger, 150 to 290V AC input, 12V 6 Ampere DC output, with trickle charging and battery repair features, reverse polarity, overcurrent and over voltage safeguards, digital display, with necessary adapters including crodile pin adapters, all as specified, directed, clarified and approved by engineer in charge
Supply Only Long Tubular Type lead acid battery 12 volt 150 AH with suitable 'C' Rating for use in DG set of capacity upto 250 kVA (or other equipment such as VCBs, etc), with minimum warranty of 36 months (of all inclusive replacement warranty - any pro rata warranty should be over and above this 36 months warranty), all as specified and defined by Engineer in Charge, of Make: Exide / Amaron/ Luminous
Supply Only electric fuel pump, 0.5 HP, self priming, for lifing of fuel from barrel to DG set tank with PVC hose pipe of size of 20 mm dia suppreior quality of length ten meters complete all as specified and directed by engineer in charge
Supply Only rotary hand pump for lifing of fuel from barrel to DG set tank with PVC hose pipe of size of 20 mm dia suppreior quality of length ten meters complete all as specified and directed by engineer in charge
Supply Only engine oil of recommended grade 15W40, in sealed containers (containers are to be left in MES) complete all as specified and directed by engineer in charge.
Supply Only Engine Coolent in sealed containers (containers are to be left in MES) complete all as specified and directed by Engineer-in-charge.
Supply Only Engine Oil Filter Suitable for 200 KVA DG Set complete all as directed by Engr-in-charge
Supply Only Engine Oil Filter Suitable for 125 KVA DG Set complete all as directed by Engr-in-charge
Supply Only Engine Oil Filter Suitable for 82.5/100 KVA DG Set complete all as directed by Engr-in-charge
Supply Only fuel Filter Suitable for 200 KVA DG Set complete all as directed by Engr-in-charge
Supply Only fuel Filter Suitable for 125 KVA DG Set complete all as directed by Engr-in-charge
Supply Only Fule Filter Suitable for 82.5/100 KVA DG Set complete all as directed by Engr-in-charge
Material and Labour for Disconnecting, taking out and opening of DG set 75/63/62.5/50 KVA by unscrewing nuts, bolts and servicing of DG set with checking of lubricating oil, coolant, V belt, greasing and oiling of parts and topping up, cleaning the inner body, tank and radiator by removing sludge etc and reassembling the DG set after repair/replacement of unserviceable parts of DG set and testing complete all as specified and directed. installed at different location of AOR. (Note :- Cost of spares/parts mentioned below will be measured and paid seprately as supply only under respective items mentioned here-in-below. However other minor consumables and spares are included).
Supply Only of Fuel filter of DG set 75/63/50 KVA complete all as specified and directed.
Supply Only of Lube oil filter of DG set 75/63/50 KVA complete all as specified and directed.
Supply Only of Air filter of DG set 75/63/50 KVA complete all as specified and directed.
Supply Only of Cooper washer of DG set 75/63/50 KVA complete all as specified and directed.
Supply Only of Banjo bolt of DG set 75/63/50 KVA complete all as specified and directed.
Supply Only of Fuel pipe of DG set 75/63 KVA complete all as specified and directed.
Supply Only of Hose water pipe for radiator of DG set 75/63/50 KVA complete all as specified and directed.
Supply Only of Warm drive H/clip of DG set 75/63/50 KVA complete all as specified and directed.
Supply Only of V-belt of DG set 75/63/50 KVA complete all as specified and directed.
Material and Labour for Disconnecting, taking out and opening of DG set of capacity from 30 to 50 kVA by unscrewing nuts, bolts and servicing of DG set with checking of lubricating oil, coolant, V belt, greasing and oiling of parts and topping up, cleaning the inner body, tank and radiator by removing sludge etc and reassembling the DG set after repair/replacement of unserviceable parts of DG set and testing complete all as specified and directed. installed at different location of AOR. (Note :- Cost of spares/parts mentioned below will be measured and paid seprately as supply only under respective items mentioned here-in-below. However other minor consumables and spares are included).
Supply Only of Fuel filter of DG set 50 KVA complete all as specified and directed.
Supply Only of Lube oil filter of DG set 50 KVA complete all as specified and directed.
Supply Only of Air filter of DG set 50 KVA complete all as specified and directed.
Supply Only of Cooper washer of DG set 50 KVA complete all as specified and directed.
Supply Only of Banjo bolt of DG set 50 KVA complete all as specified and directed.
Supply Only of Fuel pipe of DG set 50 KVA complete all as specified and directed.
Supply Only of Hose water pipe for radiator of DG set 50 KVA complete all as specified and directed.
Supply Only of Warm drive H/clip of DG set 50 KVA complete all as specified and directed.
Supply Only of V-belt of DG set 50 KVA complete all as specified and directed.
Material and Labour for Disconnecting, taking out and opening of DG set 25/ 15 KVA by unscrewing nuts, bolts and servicing of DG set with checking of lubricating oil, coolant, V belt, greasing and oiling of parts and topping up, cleaning the inner body, tank and radiator by removing sludge etc and reassembling the DG set after repair/replacement of unserviceable parts of DG set and testing complete all as specified and directed. installed at different location of AOR. (Note :- Cost of spares/parts mentioned below will be measured and paid seprately as supply only under respective items mentioned here-in-below. However other minor consumables and spares are included).
Supply Only of Fuel filter of DG set 25/ 15 KVA complete all as specified and directed.
Supply Only of Lube oil filter of DG set 25/ 15 KVA complete all as specified and directed.
Supply Only of Air filter of DG set 25/ 15 KVA complete all as specified and directed.
Supply Only of Cooper washer of DG set 25/ 15 KVA complete all as specified and directed.
Supply Only of Banjo bolt of DG set 25/ 15 KVA complete all as specified and directed.
Supply Only of Fuel pipe of DG set 25/ 15 KVA complete all as specified and directed.
Supply Only of Hose water pipe for radiator of DG set 25/ 15 KVA complete all as specified and directed.
Supply Only of Warm drive H/clip of DG set 25/ 15 KVA complete all as specified and directed.
Supply Only of V-belt of DG set 25/ 15 KVA complete all as specified and directed.
Material and Labour for Overhaul of DG Set to include disconnecting, taking out and opening of DG set, head job of 125 KVA gen set etc and reassembling the DG set after repair/replacement of unserviceable parts of DG set, any machining works (such as grinding, milling, Lathe and other jobs), any other job to make the DG Set operational and testing complete all as specified and directed. (The DG Set should be provided with an all inclusive warranty period of 365 days (of running time) from the date of making the DG set operational. Any off road period during this warranty time will sufficiently enhance the warranty duration) (Note :- Cost of spares/ parts/ jobs mentioned below will be measured and paid seprately as supply only under respective items mentioned here-in-below. However other minor consumables, spares and jobs are included).
Head facing/Grinding Job
Supply Only of Inlet/Exhaust Valve
Supply Only of Oil Valve Seal
Supply Only of Valve Spring
Supply Only of Valve Guide
Supply Only of Valve seat Inlet/Exhaust
F.I.P Calbiration, cleaning and repair Job (125 kVA DG Set)
Injector Nozzel
Supply Only of Began
Supply Only of Linear
Supply Only of Piston
Supply Only of Ring Set
Supply Only of Main Began Bearing
Supply Only of Connecting Rod Bush
Supply Only of Cylinder Rubber Kit
Supply Only of Hose Kit
Supply Only of Benjo
Supply Only of Non Return Valve (NRV)
Supply Only of Fevibond/ epoxy/ cyanoacrylate, as required for complete overhaul of the DG Set
Supply Only of Battery Charger (smart, fast charging type, with both DC and AC inputs)
Supply Only of Battery Terminals
Supply Only of Head Guide
Supply Only of Water Pump
Dynamo Repair Job
Self Starter Repair Job
Supply Only of Starter Switch 24v
Supply Only of Feed Pump
Supply Only of AVR
Supply Only of Head Gasket
Supply Only of Belt Small
Supply Only of Belt Large
Supply Only of Rocker Set/ assembly
Supply Only of Turbo Drain Pipe
Supply Only of Packing Kit, complete for the overhaul
Supply Only of Fuel Pipe
Supply Only of House Connection
Supply Only of Copper Washers
Connecting Rod alignment Job, including any stores required for replacement
Supply Only of Connecting Rod
Transportation required to work site and back/ for shifting of DG Set from one location to another
Material and Labour for Overhaul of DG Set to include disconnecting, taking out and opening of DG set, head job of 15 KVA gen set etc and reassembling the DG set after repair/replacement of unserviceable parts of DG set, any machining works (such as grinding, milling, Lathe and other jobs), any other job to make the DG Set operational and testing complete all as specified and directed. (The DG Set should be provided with an all inclusive warranty period of 365 days (of running time) from the date of making the DG set operational. Any off road period during this warranty time will sufficiently enhance the warranty duration) (Note :- Cost of spares/ parts/ jobs mentioned below will be measured and paid seprately as supply only under respective items mentioned here-in-below. However other minor consumables, spares and jobs are included).
Head facing/Grinding Job
Supply Only of Inlet/Exhaust Valve
Supply Only of Oil Valve Seal
Supply Only of Valve Spring
Supply Only of Valve Guide
Supply Only of Valve seat Inlet/Exhaust
F.I.P Calbiration, cleaning and repair Job (15 kVA DG Set)
Injector Nozzel
Supply Only of Began
Supply Only of Linear
Supply Only of Piston
Supply Only of Ring Set
Supply Only of Main Began Bearing
Supply Only of Connecting Rod Bush
Supply Only of Cylinder Rubber Kit
Supply Only of Hose Kit
Supply Only of Benjo
Supply Only of Non Return Valve (NRV)
Supply Only of Fevibond/ epoxy/ cyanoacrylate, as required for complete overhaul of the DG Set
Supply Only of Battery Charger (smart, fast charging type, with both DC and AC inputs)
Supply Only of Battery Terminals
Supply Only of Head Guide
Supply Only of Water Pump
Dynamo Repair Job
Self Starter Repair Job
Supply Only of Starter Switch 24v
Supply Only of Feed Pump
Supply Only of AVR
Supply Only of Head Gasket
Supply Only of Belt Small
Supply Only of Belt Large
Supply Only of Rocker Set/ assembly
Supply Only of Turbo Drain Pipe
Supply Only of Packing Kit, complete for the overhaul
Supply Only of Fuel Pipe
Supply Only of House Connection
Supply Only of Copper Washers
Connecting Rod alignment Job, including any stores required for replacement
Supply Only of Connecting Rod
Transportation required to work site and back/ for shifting of DG Set from one location to another
Taking down the radiator complete of DG set of capacity from 62.5 kVA to 200 kVA from its mounting and descaling the same including cleaning from top to bottom of the tank and brazing/ re-soldering complete tank and re-installing the same to its original position all as directed by Engr-in-Charge.
Taking down the radiator complete of DG set of capacity from 15 to 50 kVA from its mounting and descaling the same including cleaning from top to bottom of the tank and brazing/ re-soldering complete tank and re-installing the same to its original position all as directed by Engr-in-Charge.
Repair/ Complete Overhaul to self starter assembly of DG set of capacity of 62.5 to 125 KVA by cutting of old burnt winding with new copper winding wire as per existing size/ guage including insulation materials, varnishing and heating/ drying up jobs etc complete all as specified and directed.
Repair/ Complete Overhaul to self starter assembly of DG set of capacity of 15 to 50 KVA by cutting of old burnt winding with new copper winding wire as per existing size/ guage including insulation materials, varnishing and heating/ drying up jobs etc complete all as specified and directed.
Supply and fixing in repair off load changeover switch AC 23 side handle 4 pole, 415 volt 200 AMP complete all as specified and directed
Supply and Fixing in repair off load changeover switch AC 23 side handle 4 pole, 415 volt 320 AMP complete all as specified and directed
Supply and Fixing aluminium lugs of size 50 mm sqmm complete all as specfied and directed.
Supply and Fixing aluminium lugs of size 70 mm sqmm complete all as specfied and directed.
Supply and Fixing aluminium lugs of size 120 mm sqmm complete all as specfied and directed.
Supply and Fixing aluminium lugs of size 185 mm sqmm complete all as specfied and directed.
Supply and Fixing aluminium lugs of size 240 mm sqmm complete all as specfied and directed.
Supply and fixing battery lead wire as per existing size and length, flexible copper conductor single core including taking out old unserviceable battery lead wire complete all as specified and directed.
Supply and fixing battery terminal brass complete with GI nuts & bolts including taking out old unserviceable battery terminal brass complete all as specified and directed.
Overhauling, repairing and replacement of worn out parts of FIP, calibration and testing of fuel pump of 15 KVA to 50KVA DG set and testing on test bench and replacement of pump element, delivery valve, ball bearing and adjustment of injectors and setting of fuel pressure as per manufacturer instructions complete all as directed by the Engr-in-charge.
Overhauling, repairing and replacement of worn out parts of FIP, calibration and testing of fuel pump of 125 KVA to 200 KVA DG set and testing on test bench and replacement of pump element, delivery valve, ball bearing and adjustment of injectors and setting of fuel pressure as per manufacturer instructions complete all as directed by the Engr-in-charge.
Overhauling, repairing and replacement of worn out parts of FIP, calibration and testing of fuel pump of 50 KVA to 100 KVA DG set and testing on test bench and replacement of pump element, delivery valve, ball bearing and adjustment of injectors and setting of fuel pressure as per manufacturer instructions complete all as directed by the Engr-in-charge.
Supply only distilled water, for battery top up, in one/ five litre packaging, complete all as specified and directed by engineer in charge
Supply and Fixing (in Replacement) TurboCharger complete for DG Set of Capacity of 62.5 kVA to 125 kVA, including removal of old Turbo Charger, along with all connected Jobs and accessories, complete all as specified, clarified and directed by engineer in charge
Supply and Fixing (in replacement), Fuel Injection Pump complete for DG Set of capacity of 100 to 125 kVA Capacity (including replacement of old FIP), complete all as specified and directed by engineer in charge, complete all as specified, clarified and directed by engineer in charge
Supply and Fixing (in Replacement) Water Jacket/ Water Body complete for DG Set of Capacity of 62.5 kVA to 125 kVA (including removal of old Water Jacket/ Waterbody), along with all connected Jobs and accessories, complete all as specified, clarified and directed by engineer in charge
Supply and Fixing (in Replacement) Crank Shaft (with cranks) for DG Set of Capacity of 62.5 kVA to 125 kVA (including removal of old crank shaft), along with all connected Jobs and accessories, complete all as specified, clarified and directed by engineer in charge
Supply and Fixing (in Replacement) Self Starter complete for DG Set of Capacity of 62.5 kVA to 125 kVA (including removal of old self starter), along with all connected Jobs and accessories, complete all as specified, clarified and directed by engineer in charge
Supply and Fixing (in Replacement) Radiator Set for DG Set of Capacity of 62.5 kVA to 125 kVA (including removal of old radiator set), along with all connected Jobs and accessories, complete all as specified, clarified and directed by engineer in charge
Supply Only Long Tubular Type lead acid battery 12 volt 150 AH with suitable 'C' Rating for use in DG set of capacity upto 250 kVA (or other equipment such as VCBs, etc), with minimum warranty of 36 months (of all inclusive replacement warranty - any pro rata warranty should be over and above this 36 months warranty), all as specified and defined by Engineer in Charge, of Make: Exide / Amaron/ Luminous
Supply Only Long Tubular Type lead acid battery 12 volt 180 AH with suitable 'C' Rating for use in DG set of capacity upto 250 kVA (or other equipment such as VCBs, etc), with minimum warranty of 36 months (of all inclusive replacement warranty - any pro rata warranty should be over and above this 36 months warranty), all as specified and defined by Engineer in Charge, of Make: Exide / Amaron/ Luminous
Supply Only Long Tubular Type lead acid battery 12 volt 120 AH with suitable 'C' Rating for use in DG set of capacity upto 63 kVA (or other equipment such as VCBs, etc), with minimum warranty of 36 months (total warranty period), all as specified and defined by Engineer in Charge, of Make: Exide / Amaron/ Luminous
Supply Only Long Tubular Type lead acid battery 12 volt 80 AH with suitable 'C' Rating for use in DG set of capacity upto 35 kVA (or other equipment such as VCBs, etc), with minimum warranty of 36 months (total warranty period), all as specified and defined by Engineer in Charge, of Make: Exide Amaron/ Luminous as required and approved by Engineer in Charge
Supply Only Long Tubular Type lead acid battery 12 volt 40/ 42 AH (as required) with suitable 'C' Rating for use in DG set of capacity upto 25 kVA (or other equipment such as VCBs, etc), with minimum warranty of 36 months (total warranty period), all as specified and defined by Engineer in Charge, of Make: Exide/ Amaron/ Luminous as approved by Engineer in Charge
Supply Only Long Tubular Type lead acid battery 12 volt 20/ 26 AH (as required) with suitable 'C' Rating for use in DG set of capacity upto 15 kVA (or other equipment such as VCBs, etc), with minimum warranty of 36 months (total warranty period), all as specified and defined by Engineer in Charge, of Make: Exide/ Amaron/ Luminousas approved by Engineer in Charge
Supply only of Smart Battery Charger, with dual battery charging feature and DC and AV input features, 150 to 290V AC input, 12V 12 Ampere DC output, with trickle charging and battery repair features, reverse polarity, overcurrent and over voltage safeguards, digital multicolour LCD display, with necessary adapters including crodile pin adapters, all as specified, directed, clarified and approved by engineer in charge. Note : This item may be increased in quantity upto 6 Nos without further concurrence of the contractor
Supply only of Smart Battery Charger, 150 to 290V AC input, 12V 6 Ampere DC output, with trickle charging and battery repair features, reverse polarity, overcurrent and over voltage safeguards, digital display, with necessary adapters including crodile pin adapters, all as specified, directed, clarified and approved by engineer in charge
Supply Only electric fuel pump, 0.5 HP, self priming, for lifing of fuel from barrel to DG set tank with PVC hose pipe of size of 20 mm dia suppreior quality of length ten meters complete all as specified and directed by engineer in charge
Supply and fixing in repair rotary hand pump for lifing of fuel from barrel to DG set tank with PVC pipe of size 20 mm dia suppreior quality of length ten mtr complete all as specified and directed.
Supply Only engine oil of recommended grade 15W40, in sealed pack of 20 Liters complete all as specified and directed.
Supply Only Engine Coolent in sealed pack of 25 Liters complete all as directed by Engr-in-charge.
Supply Only Engine Oil Filter Suitable for 200/ 250 KVA DG Set complete all as directed by Engr-in-charge
Supply Only Engine Oil Filter Suitable for 125/ 100 KVA DG Set complete all as directed by Engr-in-charge
Supply Only Engine Oil Filter Suitable for 62.5 to 82.5 KVA DG Set complete all as directed by Engr-in-charge
Supply Only Engine Oil Filter Suitable for 15 to 50 KVA DG Set complete all as directed by Engr-in-charge
Taking down the radiator complete of 62.5/ 63 /75 /82.5 KVA DG set from its mounting and descaling the same including cleaning from top to bottom of the tank and brazing/ re-soldering complete tank and re-installing the same to its original position all as directed by Engr-in-Charge.
Taking down the radiator complete of 15 to 50 KVA DG set from its mounting and descaling the same including cleaning from top and bottom of the tank and brazing/ re-soldering complete tank and re-installing the same to its original position all as directed by Engr-in-Charge.
Repair/ Complete Overhaul to self starter assembly of DG set of capacity of 63/ 62.5/ 82.5 KVA by cutting of old burnt winding with new copper winding wire as per existing size/ guage including insulation materials, varnishing and heating/ drying up jobs etc complete all as specified and directed.
Repair/ Complete Overhaul to self starter assembly of DG set of capacity of 15 to 50 KVA by cutting of old burnt winding with new copper winding wire as per existing size/ guage including insulation materials, varnishing and heating/ drying up jobs etc complete all as specified and directed.
Supply and fixing off load changeover switch AC 23 side handle 4 pole, 415 volt 200 AMP complete all as specified and directed
Supply and Fixing aluminium lugs of size 50 mm sqmm complete all as specfied and directed.
Supply and Fixing aluminium lugs of size 70 mm sqmm complete all as specfied and directed.
Supply and Fixing aluminium lugs of size 120 mm sqmm complete all as specfied and directed.
Supply and Fixing aluminium lugs of size 185 mm sqmm complete all as specfied and directed.
Supply and Fixing aluminium lugs of size 240 mm sqmm complete all as specfied and directed.
Supply and Fixing battery lead wire as per existing size and length, flexible copper conductor single core including taking out old unserviceable battery lead wire complete all as specified and directed.
Supply and Fixing battery terminal brass complete with GI nuts & bolts including taking out old unserviceable battery terminal brass complete all as specified and directed.
Overhauling, repairing and replacement of worn out parts of FIP, calibration and testing of fuel pump of 15 KVA to 50KVADG set and testing on test bench and replacement of pump element, delivery valve, ball bearing and adjustment of injectors and setting of fuel pressure as per manufacturer instructions complete all as directed by the Engr-in-charge.
Overhauling, repairing and replacement of worn out parts of FIP, calibration and testing of fuel pump of 50 KVA to 100KVA DG set and testing on test bench and replacement of pump element, delivery valve, ball bearing and adjustment of injectors and setting of fuel pressure as per manufacturer instructions complete all as directed by the Engr-in-charge.
Supply only distilled water, for battery top up, in one/ five litre packaging, complete all as specified and directed by engineer in charge
Supply Only Long Tubular Type lead acid battery 12 volt 150 AH with suitable 'C' Rating for use in DG set of capacity upto 250 kVA (or other equipment such as VCBs, etc), with minimum warranty of 36 months (of all inclusive replacement warranty - any pro rata warranty should be over and above this 36 months warranty), all as specified and defined by Engineer in Charge, of Make: Exide / Amaron/ Luminous
Supply Only rotary hand pump for lifing of fuel from barrel to DG set tank with PVC hose pipe of size of 20 mm dia suppreior quality of length ten meters complete all as specified and directed by engineer in charge
Supply Only engine oil of recommended grade 15W40, in sealed containers (containers are to be left in MES) complete all as specified and directed by engineer in charge.
Supply Only Engine Coolent in sealed sealed containers (containers are to be left in MES) complete all as specified and directed by engineer in charge
Supply Only Engine Oil Filter Suitable for up to100 KVA DG Set complete all as directed by Engr-in-charge
Supply Only Fuel Filter Suitable for up to 100 KVA DG Set complete all as directed by Engineer-in-charge
Material and Labour for Overhaul of DG Set to include disconnecting, taking out and opening of DG set, head job of 82.5/ 75 KVA gen set etc and reassembling the DG set after repair/replacement of unserviceable parts of DG set, any machining works (such as grinding, milling, Lathe and other jobs), any other job to make the DG Set operational and testing complete all as specified and directed. (The DG Set should be provided with an all inclusive warranty period of 365 days (of running time) from the date of making the DG set operational. Any off road period during this warranty time will sufficiently enhance the warranty duration)(Note :- Cost of spares/ parts/ jobs mentioned below will be measured and paid seprately as supply only under respective items mentioned here-in-below. However other minor consumables, spares and jobs are included).
Head facing/Grinding Job
Supply Only of Inlet/Exhaust Valve
Supply Only of Oil Valve Seal
Supply Only of Valve Spring
Supply Only of Valve Guide
Supply Only of Valve seat Inlet/Exhaust
F.I.P Calbiration, cleaning and repair Job (82.5/ 75 kVA DG Set)
Injector Nozzel
Supply Only of Began
Supply Only of Linear
Supply Only of Piston
Supply Only of Ring Set
Supply Only of Main Began Bearing
Supply Only of Connecting Rod Bush
Supply Only of Cylinder Rubber Kit
Supply Only of Hose Kit
Supply Only of Benjo
Supply Only of Non Return Valve (NRV)
Supply Only of Fevibond/ epoxy/ cyanoacrylate, as required for complete overhaul of the DG Set
Supply Only of Battery Charger (smart, fast charging type, with both DC and AC inputs)
Supply Only of Battery Terminals
Supply Only of Head Guide
Supply Only of Water Pump
Dynamo Repair Job
Self Starter Repair Job
Supply Only of Starter Switch 24v
Supply Only of Feed Pump
Supply Only of AVR
Supply Only of Head Gasket
Supply Only of Belt Small
Supply Only of Belt Large
Supply Only of Rocker Set/ assembly
Supply Only of Turbo Drain Pipe
Supply Only of Packing Kit, complete for the overhaul
Supply Only of Fuel Pipe
Supply Only of House Connection
Supply Only of Copper Washers
Connecting Rod alignment Job, including any stores required for replacement
Supply Only of Connecting Rod
Transportation required to work site and back/ for shifting of DG Set from one location to another
Material and Labour for Overhaul of DG Set to include disconnecting, taking out and opening of DG set, head job of 63/ 62.5/ 50 KVA gen set etc and reassembling the DG set after repair/replacement of unserviceable parts of DG set, any machining works (such as grinding, milling, Lathe and other jobs), any other job to make the DG Set operational and testing complete all as specified and directed. (The DG Set should be provided with an all inclusive warranty period of 365 days (of running time) from the date of making the DG set operational. Any off road period during this warranty time will sufficiently enhance the warranty duration) (Note :- Cost of spares/ parts/ jobs mentioned below will be measured and paid seprately as supply only under respective items mentioned here-in-below. However other minor consumables, spares and jobs are included).
Head facing/Grinding Job
Supply Only of Inlet/Exhaust Valve
Supply Only of Oil Valve Seal
Supply Only of Valve Spring
Supply Only of Valve Guide
Supply Only of Valve seat Inlet/Exhaust
F.I.P Calbiration, cleaning and repair Job (62.5/ 50 kVA DG Set)
Injector Nozzel
Supply Only of Began
Supply Only of Linear
Supply Only of Piston
Supply Only of Ring Set
Supply Only of Main Began Bearing
Supply Only of Connecting Rod Bush
Supply Only of Cylinder Rubber Kit
Supply Only of Hose Kit
Supply Only of Benjo
Supply Only of Non Return Valve (NRV)
Supply Only of Fevibond/ epoxy/ cyanoacrylate, as required for complete overhaul of the DG Set
Supply Only of Battery Charger (smart, fast charging type, with both DC and AC inputs)
Supply Only of Battery Terminals
Supply Only of Head Guide
Supply Only of Water Pump
Dynamo Repair Job
Self Starter Repair Job
Supply Only of Starter Switch 24v
Supply Only of Feed Pump
Supply Only of AVR
Supply Only of Head Gasket
Supply Only of Belt Small
Supply Only of Belt Large
Supply Only of Rocker Set/ assembly
Supply Only of Turbo Drain Pipe
Supply Only of Packing Kit, complete for the overhaul
Supply Only of Fuel Pipe
Supply Only of House Connection
Supply Only of Copper Washers
Connecting Rod alignment Job, including any stores required for replacement
Supply Only of Connecting Rod
Transportation required to work site and back/ for shifting of DG Set from one location to another
Taking down the radiator complete of 62.5/ 63 /75 /82.5 KVA DG set from its mounting and descaling the same including cleaning from top to bottom of the tank and brazing/ re-soldering complete tank and re-installing the same to its original position all as directed by Engr-in-Charge.
Taking down the radiator complete of 15 to 50 KVA DG set from its mounting and descaling the same including cleaning from top and bottom of the tank and brazing/ re-soldering complete tank and re-installing the same to its original position all as directed by Engr-in-Charge.
Repair/ Complete Overhaul to self starter assembly of DG set of capacity of 62.5/ 63/ 82.5 KVA by cutting of old burnt winding with new copper winding wire as per existing size/ guage including insulation materials, varnishing and heating/ drying up jobs etc complete all as specified and directed.
Repair/ Complete Overhaul to self starter assembly of DG set of capacity of 15 to 50 KVA by cutting of old burnt winding with new copper winding wire as per existing size/ guage including insulation materials, varnishing and heating/ drying up jobs etc complete all as specified and directed.
Supply and fixing off load changeover switch AC 23 side handle 4 pole, 415 volt 200 AMP complete all as specified and directed
Supply and Fixing aluminium lugs of size 50 mm sqmm complete all as specfied and directed.
Supply and Fixing aluminium lugs of size 70 mm sqmm complete all as specfied and directed.
Supply and Fixing aluminium lugs of size 120 mm sqmm complete all as specfied and directed.
Supply and Fixing aluminium lugs of size 185 mm sqmm complete all as specfied and directed.
Supply and Fixing aluminium lugs of size 240 mm sqmm complete all as specfied and directed.
Supply and Fixing battery lead wire as per existing size and length, flexible copper conductor single core including taking out old unserviceable battery lead wire complete all as specified and directed.
Supply and Fixing battery terminal brass complete with GI nuts & bolts including taking out old unserviceable battery terminal brass complete all as specified and directed.
Overhauling, repairing and replacement of worn out parts of FIP, calibration and testing of fuel pump of 15 KVA to 50KVA DG set and testing on test bench and replacement of pump element, delivery valve, ball bearing and adjustment of injectors and setting of fuel pressure as per manufacturer instructions complete all as directed by the Engr-in-charge.
Overhauling, repairing and replacement of worn out parts of FIP, calibration and testing of fuel pump of 50 KVA to 100KVA DG set and testing on test bench and replacement of pump element, delivery valve, ball bearing and adjustment of injectors and setting of fuel pressure as per manufacturer instructions complete all as directed by the Engr-in-charge.
Supply only distilled water, for battery top up, in one/ five litre packaging, complete all as specified and directed by engineer in charge
Supply Only engine oil of recommended grade 15W40, in sealed containers (containers are to be left in MES) complete all as specified and directed by engineer in charge.
Supply Only Engine Coolent in sealed containers (containers are to be left in MES) complete all as specified and directed by Engineer-in-charge.
Supply Only Engine Oil Filter Suitable for up to100 KVA DG Set complete all as directed by Engineer-in-charge
Supply Only Fuel Filter Suitable for up to 100 KVA DG Set complete all as directed by Engineer-in-charge
Supply Only Long Tubular Type lead acid battery 12 volt 150 AH with suitable 'C' Rating for use in DG set of capacity upto 250 kVA (or other equipment such as VCBs, etc), with minimum warranty of 36 months (of all inclusive replacement warranty - any pro rata warranty should be over and above this 36 months warranty), all as specified and defined by Engineer in Charge, of Make: Exide / Amaron/ Luminous
Supply Only electric fuel pump, 1 HP, self priming, for lifing of fuel from barrel to DG set tank with PVC hose pipe of size of 20 mm dia suppreior quality of length ten meters complete all as specified and directed by engineer in charge
Supply and Fixing (in replacement), Fuel Injection Pump complete for DG Set of capacity of 50 to 82.5 kVA Capacity, complete all as specified and directed by engineer in charge (for capacities of 100 kVA to 250 kVA, two quantities of same item schedule will be paid against one quantity fixed)
Supply Only rotary hand pump for lifing of fuel from barrel to DG set tank with PVC hose pipe of size of 20 mm dia suppreior quality of length ten meters complete all as specified and directed by engineer in charge
Repair/ complete Overhaul to self starter assembly of DG Set of capacity of from 50 to 125 KVA by cutting to old burnt winding with new copper winding wire as per existing size/ guage including insulation materials, varnishing and heating/ dring up jobs etc complete all as specified and directed. (Note : for 2501 KVA Capacity self starter assembly, 02 Nos (Each Job) of this item will be considered)
Supply and fix alumimium lugs of size 50 mm sqmm complete all as specified and directed.
Supply and fix alumimium lugs of size 70 mm sqmm complete all as specified and directed.
Supply and fix alumimium lugs of size 120 mm sqmm complete all as specified and directed.
Supply and fix alumimium lugs of size185 mm sqmm complete all as specified and directed.
Supply and fix alumimium lugs of size240 mm sqmm complete all as specified and directed.
Supply & Fixing battery lead wireas per existing size and length, flexible copper conductor 50 sqm single core including taking out old unserviceable battery lead wire complete all as specified and directed.
Supply and fixing battery teminal brass complete with brass nuts & bolts including taking out old unserviceable battery teminal brass complete all as speficied and directed.
Material and Labour for replacement of Old Unserviceable water Body of 63/ 62.5KVA DG Set with new water body, including all related jobs such as machining work (Lathe, milling, cutting, grinding,etc), etc and accessories such as nuts bolts, sealents, etc,
Supply only distilled water, for battery top up, in one/ five litre packaging, complete all as specified and directed by engineer in charge
Supply Only Long Tubular Type lead acid battery 12 volt 15 AH with suitable 'C' Rating for use in DG set of capacity upto 250KVA (Or other equipment such VCBs, etc), with minimum warranty), all as specified and defined by Engineer-in-Charge, of Make : Exide/ Amaron/ Luminous
Supply Only Engine Coolent in sealed containers (containers are to be left in MES) complete all as specified and directed by Engineer-in-charge.
Supply Only engine oil of recommended grade 15W40, in sealed containers (Containers are to be left in MES) complete all as specified and directed by engineer in Charge
Supply only of Smart Battery Charger, with dual battery charging feature and DC and AV input features, 150 to 290V AC input, 12V 12 Ampere DC output, with trickle charging and battery repair features, reverse polarity, overcurrent and over voltage safeguards, digital multicolour LCD display, with necessary adapters including crodile pin adapters, all as specified, directed, clarified and approved by engineer-in- Charge
Supply only of Smart Battery charger, 150 to 290V AC input, 12V 6 Ampere DC output, with trickle charging and battery repair features, reverse polarity, overcurrent and over voltage safeguards, digital display, with necessary adapers including cordile pin adapters, all as specified, directed, clarified and approved by Engineer-in-Charge.
Supply Only Engine Oil Filter Suitable for up to 125KVA DG Set complete all as specifed and directed by Engineer-in-Charge
Supply Only Engine Oil Filter Suitable for up to 250/200KVA DG Set complete all as specifed and directed by Engineer-in-Charge
M/S ASHRAF CONSTRUCTIONS
M/S SHIMAR STAR GLACIER
M/S Noor Mohammad Shalla
M/s Lal Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .