Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹39.7 LAccepted-AOC | L-1 | Accepted-AOC RATES ARE FOUND REASONABLE AND THE FIRM BEING L1 BIDDER | |
| 2 | L-2₹43.7 L+₹1.5 L (3.45%)Rejected-Finance STATION ROAD POST RANGIYA DIST KAMRUP ASSAM PIN 781354 | KAMRUP | ASSAM | 781354 | L-2 | Rejected-Finance BEING L2 BIDDER | |
| 3 | L-3₹43.8 L+₹1.5 L (3.61%)Rejected-Finance RANGIYA DIST KAMRUP ASSAM 781365 | BAKSA | ASSAM | 781365 | L-3 | Rejected-Finance BEING L3 BIDDER | |
| 4 | L-4₹45.9 L+₹3.7 L (8.67%)Rejected-Finance P O RANGIA WARD NO 3 DIST KAMRUP ASSAM | KAMRUP | ASSAM | 781354 | L-4 | Rejected-Finance BEING L4 BIDDER | |
| 5 | L-5₹48.3 L+₹6.1 L (14.4%)Rejected-Finance | L-5 | Rejected-Finance BEING L5 BIDDER |
Tender Value
₹47.9 L
EMD Value
₹95,800
Closing Date
6 Apr 2023, 6:00 pmClosed
GE RANGIA
GE Rangia C/O 99 APO Rangia
SPL REP TO BLDG NO ET-102, ET-103 AND ET-84 AT GE RANGIA UNDER GE RANGIA
2023_MES_585469_1
8655/E8
Open Tender
Civil Works
Item Rate
180 days
RANGIA
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE Rangia
₹95,800
Yes
11 May 2023
11 Mar 2023
8 Apr 2023
11 Mar 2023
6 Apr 2023
25 Mar 2023
11 Mar 2023 - 18 Mar 2023
Amount
M&L for Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and as directed by Engineer-in-charge.
M&L for taking down Chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 sq. m but not exc. 4.0 sq. m each, complete all as specified and as directed by Engineer-in-charge.
M&L for taking down Chowkhats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sq. m each, complete all as specified and as directed by Engineer-in-charge.
M&L for Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed by Engineer-in-charge.
M&L for demolition of Cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and as directed by Engineer-in-charge.
M&L for demolition of reinforced Cement concrete of any description and in any position not otherwise specifically provided for, complete all as specified and as directed by Engineer-in-charge.
M&L for Dismantling boarding, any description, fixed in any position with nails, complete all as specified and as directed by Engineer-in-charge.
M&L for dismantling Asbestos cement (corrugated, semi-corrugated, etc.) sheets in roof coverings, complete all as specified and as directed by Engineer-in-charge.
M&L for demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, complete all as specified and as directed by Engineer-in-charge.
M&L for Dismantling timber scantlings 40 sq. cm and over in section, in any position and in unframed work, complete all as specified and as directed by Engineer-in-charge.
M&L for Hacking out old broken glass (any thickness, size, quality or description) from wooden/steel frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads, complete all as specified and as directed by Engineer-in-charge.
M&L for Dismantling timber fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section and in unframed work, complete all as specified and as directed by Engineer-in-charge.
M&L for Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and as directed by Engineer-in-charge.
M&L for Providing Cement Concrete 1:3:6, type C-1 (20mm graded aggregate) as in Coping, edging, lintels upto 1.5m clear span, cills, steps; hold-fast block, filling in pressed steel frames, seismic and other similar bands etc. and finishing the Concrete surfaces Fair and Even including necessary Formwork required at Site(s), complete all as specified and as directed by Engineer-in-charge.
M&L for Reinforced Cement Concrete, 1:2:4 (Nominal Mix) (20mm graded stone aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item.
M&L for Reinforced Cement Concrete, 1:2:4 (Nominal Mix) (20mm graded stone aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item.
M&L for Reinforced Cement Concrete, 1:2:4 (Nominal Mix) (20mm graded stone aggregate) in Columns, pillars, piers, posts and struts, complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item.
S&F of TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed by Engineer-in-charge.
S&F of TMT bars 6-8mm dia, cut to length, bent to shape required, in stirrups, spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed by Engineer-in-charge.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), rough finished flat surfaces of concrete, complete all as specified and as directed by Engineer-in-charge.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc., rough finished flat surfaces of concrete, complete all as specified and as directed by Engineer-in-charge.
M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions, rough finished flat surfaces of concrete, complete all as specified and as directed by Engineer-in-charge.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built and set in cement mortar 1:4, complete all as per specified and as directed by Engineer-in-charge.
S&F of Pressed steel frames for doors of size 105x60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and as directed by Engineer-in-charge.
S&F of Pressed steel frames for doors of size 125x60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and as directed by Engineer-in-charge.
S&F of 30mm thick factory made second class hard wood Glazed and skeleton shutters, divided into squares and prepared to receive glass, gauze, etc. (without sash bars) with plain, chamfered or rounded, mitred and rebated sash bars, any numbers; complete all as specified and as directed by Engineer-in-charge.
S&F of 30mm thick factory made second class hard wood Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides; complete all as specified and as directed by Engineer-in-charge.
S&F of Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement; complete all as specified and as directed by Engineer-in-charge.
S&F of Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube; complete all as specified and as directed by Engineer-in-charge.
S&F of 125 mm long aluminium handles, cast type, anodised, complete all as specified and as directed by Engineer-in-charge.
S&F of 100 mm long aluminium handles, cast type, anodised, complete all as specified and as directed by Engineer-in-charge.
S&F of 200 mm long Aluminium anodised, barrel tower bolts of extruded section, complete all as specified and as directed by Engineer-in-charge.
S&F of 100 mm long Aluminium anodised, barrel tower bolts of extruded section, complete all as specified and as directed by Engineer-in-charge.
S&F of 250 mm long Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate, complete all as specified and as directed by Engineer-in-charge.
S&F of 125 mm long Butt hinges, medium weight, cold rolled mild steel, complete all as specified and as directed by Engineer-in-charge.
S&F of 75 mm long Butt hinges, medium weight, cold rolled mild steel, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of 140 mm Overall length of cover plate Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring and rubber end, fixed in floor, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Mild steel 300mm long, ordinary rat tail rod pattern springs including roller and roller plate, complete all as specified and as directed by Engineer-in-charge.
S&F of Galvanised mild steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified and as directed by Engineer-in-charge.
S&F of 3mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane, complete all as specified and as directed by Engineer-in-charge.
M&L for Rendering (Externally) 15mm thick in Cement Mortar 1:4 in two layers on Brick Walls/Concrete Surfaces, 5mm thick top layer mixed with WPC as per Manufactures instruction, plastered surfaces finished Even and Smooth without using Extra Cement, complete all as specified and as directed by Engineer-in-charge. NOTE: WPC shall be Measured and Paid as ‘Supply only’ under relevant Item.
M&L for Rendering (Internally) 10mm thick in cement morter 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-in-charge.
Supply only Integral waterproofing compound, complete all as specified and as directed by Engineer-in-charge.
M&L for preparing newly plastered surfaces of wall and applying two coats of distemper oil emulsion of any shade over a coat of chalk whitening and a coat of avg 1.00mm thick wall care putty including rubbing down the putty surfaces to obtained smooth finish, complete all as specified and as directed by Engineer-in-charge.
M&L for preparing newly plastered surfaces of wall and applying two coats of cement base paint of any shade over a coat of primer, complete all as specified and as directed by Engineer-in-charge.
M&L for Complete removal of existing treatment of wall and applying two coats of distemper oil emulsion of any shade over a coat of chalk whitening and a coat of avg 1.00mm thick wall care putty including rubbing down the putty surfaces to obtained smooth finish, complete all as specified and as directed by Engineer-in-charge.
M&L for Complete removal of existing treatment of wall and applying two coats of cement base paint of any shade over a coat of primer, complete all as specified and as directed by Engineer-in-charge.
M&L for Preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with two coats of Creosote oil, complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of new or previously un-treated wooden Surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of Synthetic enamel paint (1st quality) of any tint over a coat of pink primer, complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of new or previously un-treated steel/iron surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of Synthetic enamel paint (1st quality) of any tint over a coat of red oxide primer, complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of new or previously un-treated wooden Surfaces of any description n exc 10cm width or girth when unconnected with other painting or when painted in different tint and applying two coats of Synthetic enamel paint (1st quality) of any tint over a coat of pink primer, complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of old painted steel/ iron surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of Synthetic enamel paint (1st quality) of any tint, complete all as specified and as directed by Engineer-in-charge.
S&F of Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded, complete all as specified and as directed by Engineer-in-charge.
S&F of Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and as directed by Engineer-in-charge.
S&F of Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and as directed by Engineer-in-charge.
S&F of mild steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and as directed by Engineer-in-charge.
S&F of Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. of Fe 410 -W (Gde- E- 250) quality-A, complete all as specified and as directed.
All as per Item No.- 58 here-in-above, but for erection and fixing only, complete all as specified and as directed.
S&F in-repair of exposed GI powder coated snap grid frame work for false ceiling of grid size 600x600mm comprising of wall/cleat angle of size 25x25x0.35mm and cross tee of size 22x35x0.60mm with 1mm dia GI wire as suspender fixed to roof of any type by means of ceiling cleats made out of GI flat of 40x3mm with and including supplying and fixing of 4mm thick pre-painted designer classic E-board (595x595mm) laid/ inserted into snap grid frame work, complete all as per specified and as directed by Engineer-in-charge.
M&L for 2nd class hard wood in scantling wrought timber unframed and fixed, complete all as specified and as directed by Engineer-in-charge.
M&L for 50mm thick second class hardwood Boarding, Planed on both sides, with butt joints and fixed with nails, as in any position and in any situation, complete all as specified and as directed.
M&L for second class hard wood plain fillets in square, rectangular or triangular in section, clean sawn, secured with nails or brads of sectional area exc. 6sqcm but not exc.13sqcm, complete all as specified and as directed by Engineer-in-charge.
S&F in-repairs in patches n exc 5 sq. m each, including taking down old and jointing new to old as required of GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste, complete all as specified and as directed by Engineer-in-charge.
S&F of 0.50mm thick Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed by Engineer-in-charge.
S&F of 0.50mm thick Pre-painted galvalume aluminum zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed by Engineer-in-charge.
S&F of 3mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of 20 mm dia mild steel, chromium plated fancy type curtain rail with fixing brackets, stops, rollers etc., complete all as specified and as directed by Engineer-in-charge.
M&L for providing 75 mm thick Cement concrete type D-2, 1:4:8 (40mm graded stone aggregate) as in sub-base of floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces rough, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing 75 mm thick Cement concrete type C-2, 1:3:6 (40mm graded stone aggregate) as in floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and fair, complete all as per specified and as directed by Engineer-in-charge.
M&L for Forming Construction (Dummy) joint 30mm deep x 10mm wide filled with sealing compound Grade 'A', complete all as per specified and as directed by Engineer-in-charge.
M&L for providing 40 mm thick Cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) as in floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces rough, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing Non-skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc., laid over 20mm thick cement screed 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing Non-skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in vertical surfaces, like skirting, dado, etc., fixed over 10mm thick cement screed 1:3 set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing Non-skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc., laid over 20mm thick cement screed 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing Glazed ceramic coloured tiles in vertical surface (like skirting, dado, etc.) 300x 450x 7 mm thick, over 10mm thick cement screed 1:3 set and jointed in neat cement slurry and pointed in white or colour cement to match, complete all as per specified and as directed by Engineer-in-charge.
M&L for 20mm thick Granite work (of any type, table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in 10mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as per specified and as directed by Engineer-in-charge.
S&F in-repair of 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls, complete all as per specified and as directed by Engineer-in-charge.
S&F in-repair of 75mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls, complete all as per specified and as directed by Engineer-in-charge.
S&F in-repair of 110 mm dia PVC (SWR) bends of any radius, complete all as per specified and as directed by Engineer-in-charge.
S&F in-repair of 110 mm dia PVC (SWR) vent cowl, complete all as per specified and as directed by Engineer-in-charge.
S&F in-repair of 15 mm dia galvanised iron steel tubes, 'medium grade' with all fitting and fixed to walls and ceilings or laid in floors, complete all as per specified and as directed by Engineer-in-charge.
S&F in-repair of 20 mm dia galvanised iron steel tubes, 'medium grade' with all fitting and fixed to walls and ceilings or laid in floors, complete all as per specified and as directed by Engineer-in-charge.
S&F in-repair of High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed to walls, ceilings or in floors etc., complete all as per specified and as directed by Engineer-in-charge.
S&F in-repair of PVC connections 15mm size with PTMT nuts of length 450mm, complete all as per specified and as directed by Engineer-in-charge.
S&F in-repair of Bib taps, cast copper alloy fancy type, chromium plated with crutch or butterfly handle, screwed down, screwed for 15mm dia iron pipe or for brass ferrule and fixed, complete all as per specified and as directed by Engineer-in-charge.
S&F in-repair of Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for 15mm dia iron pipe or for unions and fixed, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair vitreous china wall hung wash hand basin white, flat back, 200 x 550 x 400 mm size (flat back or angle back type) including padestal and cutting for and pinning ends of brackets or erecting stand etc., complete all as per specified and as directed by Engineer-in-charge. MAke- Jaquar Cat Pt No.- SLS-WHT- 0611F
S&F in repair of 15 mm bore brass CP Basin mixer for mixing hot & cold water arrangement screwed down for iron pipe, complete all as per specified and as directed by Engineer-in-charge.
S&F in-repair of Chromium plated shower rose of size 125mm with or without swivel joints, any size, including fixing to steel pipe or union, complete all as per specified and as directed by Engineer-in-charge.
S&F in-repair of Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including seat cover, closed pattern with flat bottom and cover with chromium plated hinging device, complete all as per specified and as directed by Engineer-in-charge.
S&F in-repair of 10 Litre capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair of 15 mm bore brass CP wall mixer (3-in-1) for mixing hot & cold water with telephonic shower arrangement (with CP hand shower and 1.0m long hose) screwed down for iron pipe, complete all as per specified and as directed by Engineer-in-charge.
S&F in-repair of sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm, complete all as per specified and as directed by Engineer-in-charge.
S&F in-repair of 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement, complete all as per specified and as directed by Engineer-in-charge.
Taking down carefully copper/alumunium point wiring for light, fan, bell, socket or power complete including fittings such as switches, ceiling roses pendents regulators, sockets and excluding tube light fittings etc, removing materials from site and making good distrubed surface of wall, floors, etc. complete all as specified and as directed by Engineer-in-charge.
M&L for point wiring with 1.5 sqmm size (nominal area) PVC insulated unsheathed single core multi stranded FRLSH copper conductor cable drawn into and incl PVC casing capping sleeves and caps of adequate width and length with all accessories and fittings like bends . elbow crosses etc with PVC round block and PVC terminal boxes with 3.00mm thick laminated sheet cover for mounting fittings etc like switches sockets and fan regulator incl 1.5 sqmm size PVC insulated multistranded FRLSH copper conductor cable as earth continuity conductor and connected to earth dolly for one light/ fan/ exhaust fan/ bell point controlled by one 1-way switch/ bell push, complete all as per specified and as directed by Engineer-in-Charge.
All as per serial item No. 97 above but for 3 pin socket outlet point controlled by one 5/6 Amp, one way switch on the same board, complete all as specified and as directed by Engineer-in-charge.
All as per serial item No. 97 above but for 3 pin socket outlet point controlled by one 5/6 Amp, one way switch on the independent board, complete all as specified and as directed by Engineer-in-charge.
All as per serial item no. 97 above but with 4 sqmm (nominal area) cable with 4.00 sq mm size copper earth continuity conductor of green colour for 15 A socket on independent boards, complete all as specified and as directed by Engineer-in-charge.
S&F of switch piano flush type, 5/6 Amps 240 volts single pole one way, complete all as specified and as directed by Engineer-in-charge.
S&F of ceiling rose surface backelite three terminals, PVC/ polycarbonate, insulated body, complete all as specified and as directed by Engineer-in-charge.
S&F of socket outlet 3 pin 5/6 Amp flush type complete all as specified and as directed by Engineer-in-charge.
S&F of switch socket combination 5/6 Amp 3 pin flush type, complete all as specified and as directed by Engineer-in-charge.
S&F of switch socket combination 15/16 Amp 3 pin flush type, complete all as specified and as directed by Engineer-in-charge.
S & F of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of LED lights fitting 1x 20W, 240V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm, complete all as specified and as directed by Engineer-in-charge.
S&F of PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 250 x 200 x 50 mm deep, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Sheet Metal Enclosure MCB DB SPN, 8 way 240 volt, with 200 Amps rated Bus-bar, double door type MCB DB suitable for mounting incoming and outgoing MCBs double pole/ single pole complete all as specified and as directed.
S&F in-repair of Sheet Metal Enclosure MCB DB SPN, 12 way 240 volt, with 200 Amps rated Bus-bar, double door type MCB DB suitable for mounting incoming and outgoing MCBs double pole/ single pole complete all as specified and as directed.
S&F of call Bell, ding-dong type, AC, 240 volts, single pole, complete all as specified and as directed.
S&F of Modular Bell push 6A 1 module, complete all as specified and as directed.
S&F in-repair of MCB Single Pole (SP), 'B' Curve, 6-32 Amps, 240 Volt for fixing on MCB DB’s, 10 kA, 50 Hz, conforming to IS/IEC 60898 and connecting up, complete all as specified and as directed.
S&F in-repair of MCB Single Pole & Neutral (SPN), 'C' Curve, 32 Amps, 240 Volt for fixing on MCB DB’s, 10 kA, 50 Hz, conforming to IS/IEC 60898 and connecting up, complete all as specified and as directed.
S&F in-repair of MCB Single Pole & Neutral (SPN), 'C' Curve, 40 Amps, 240 Volt for fixing on MCB DB’s, 10 kA, 50 Hz, conforming to IS/IEC 60898 and connecting up, complete all as specified and as directed.
Supply and fixing of 1100 volts grade heavy duty cable, PVC insulated aluminium stranded condcutor with inner sheathed of PVC tape and over all PVC sheathed for service connection suspended by insulating hangers not more than 01 mtr apart including 4mm dia suspension wire and 16Sqmm twin core cable flat or circular complete including taking down old service connection all as specified and as directed by Engineer-in-charge.
S&F in-repair of LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed.
S&F of Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed.
S&F in-repair of LED Bulb/ Lamp of 7 Watt, B-22 base, complete all as specified and as directed.
M&L for refixing in existing position after proper cleaning including taking down Ceiling fan/ Exhaust fan, complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs), complete all as specified & testing on completion. NOTE:- (i) item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire. (iii) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe,bends,elbow etc shall be deemed included in the unit rate. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ.
M/S KIRAN ENTERPRISE
M/S NARAYAN ENTERPRISE
MUKUL CHOUDHURY
DILIP KUMAR SINGH
Shiva Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .