Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.9 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹14.2 L+₹1.8 L (14.5%)Rejected-Finance M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L2 | Rejected-Finance Not L1 Bidder | |
| 3 | L3₹14.8 L+₹2.4 L (19.5%)Rejected-Finance | L3 | Rejected-Finance Not L1 Bidder | |
| 4 | L4₹16.9 L+₹4.5 L (36.3%)Rejected-Finance | L4 | Rejected-Finance Not L1 Bidder | |
| 5 | L5₹19.1 L+₹6.7 L (54.0%)Rejected-Finance | L5 | Rejected-Finance Not L1 Bidder |
Tender Value
Refer Docs
EMD Value
₹32,000
Closing Date
16 Jun 2021, 6:00 pmClosed
GARRISON ENGINEER CENTRAL BANGALORE
MILITARY ENGINEER SERVICES GARRISON ENGINEER CENTRAL AGRAM POST BANGALORE 560007
REPAIR MAINTENANCE OF INTERNAL WIRING, LIGHT FITTINGS AT ASC R 531 ORs AND ASC CENTRE AND COLLEGE UNDER GE CENTRAL BANGALORE
2021_MES_444121_1
8128E
Open Tender
Civil Works
Item Rate
180 days
BANGALORE
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER CENTRAL BANGALORE
₹32,000
Yes
16 Aug 2021
19 May 2021
18 Jun 2021
19 May 2021
16 Jun 2021
2 Jun 2021
19 May 2021 - 1 Jun 2021
Amount
Taking down copper/ aluminium point wiring(light, fan, socket or power) complete, including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperately) and making good distrubed surfaces of wall, floors, etc complete.
Point wiring with PVC insulated and unsheathed FRLS cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS-694 1990 drawn in and including PVC rigid non metalic conduit (Medium Grade) on surface conforming to IS-9537 with all accessories including fabricated MS terminal boxes fixed flush with wall surface with 3mm thick laminated sheet top cover fixed with brass screw for mounting switches, sockets, regulator etc including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for :- One light point controlled by one 5 Amps switch one way
All as per item No 2 above but for one fan point controlled by one 5 Amps switch one way
All as per item No 2 above but for one bell point controlled by one switch
All as per item No 2 above but for one 3 pin socket point 5 Amp on independent board
All as per item No 2 above but for one 3 pin socket point 5 Amp on same board with other switches.
All as per item No. 2 above but using 4 sqmm ( Nominal area ) cable with 4 Sqmm size copper earth continuity conductor for 3 pin 15 A socket outlet on independent board complete all as specified and directed.
Point Wiring with 1.5 Sqmm (Nominal Area) PVC insulated unsheathed 1100 Volts Grade Stranded Copper Conductor Cable (Red Colour Cable for Phase and Black Colour Cable for Neutral), laid in and including PVC Casing and Capping with Accessories (size of Casing and Capping as required at Site) including 1.50 Sqmm PVC ins-ulated Stranded Copper Conductor Cable (Green Colour) as Earth Continuity Conductor and connected to Common Earth Dolly or as directed and MS terminal boxes fixed flush with wall surface including providing 3mm thick masonite laminated sheet top cover for one light and fan point controlled by one switch complete all as specified and as directed are as follows :- One light point controlled by one 5 Amps switch one way
All as per item No 8 above/here-in-before but one fan point controlled by one 5 Amps switch one way
All as per item No 8 above/here-in-before but one 3 pin socket point 5 Amp on independent board
All as per item No 8 above/here-in-before but one 3 pin socket point 5 Amp on same board with other switches.
All as per item No. 8 above but using 4 sqmm ( Nominal area ) cable with 4 Sqmm size copper earth continuity conductor for 3 pin 15 A socket outlet on independent board complete all as specified and directed.
Supply and fix Switch piano, flush button single pole, 5 Amps one way. Make : Anchor/Leader/Legrand/Crabtree
Supply and fix bell push, flush button single pole, 5 Amps one way. Make : Anchor/Leader/Legrand/Crabtree
Supply and fix Switch sokcet combination flush type 5 Amp 2/3 pin muliti purpose Make : Anchor/Leader/Legrand/Crabtree
Supply and fix Switch socket combination flush type 5/15 Amps 3/3 pin universal multipurpose Make : Anchor/Leader/Legrand/Crabtree
Supply and fix Fan regulator electronic, step & socket type 230 volt, suitable for 1200/1400mm sweep ceiling fan. Make : Anchor/Leader/Legrand/Crabtree
Supply and fix Ceiling rose surface bakelite 65x50mm three terminals including supply and fix PVC blocks. Make : Anchor/Leader/Legrand/Crabtree
Supply and fix in repair Switch piano, flush button single pole, 5 Amps one way. Make : Anchor/Leader/Legrand/Crabtree
Supply and fix in repair Switch sokcet combination flush type 5 Amp 2/3 pin muliti purpose Make : Anchor/Leader/Legrand/Crabtree
Supply and fix in repair Switch socket combination flush type 5/15 Amps 3/3 pin universal multipurpose Make : Anchor/Leader/Legrand/Crabtree
Supply and fix in repairs modular switch 1 way 6A,1 module Make : Anchor/Leader/Legrand/Crabtree
Supply and fix in repairs modular switch 1 way 16A,1 module Make : Anchor/Leader/Legrand/Crabtree
Supply and fix in repairs socket, 6A-2/3 pin combined 2 modules Make : Anchor/Leader/Legrand/Crabtree
Supply and fix in repairs socket, 6A/16A-2/3 pin combined 2 modules Make : Anchor/Leader/Legrand/Crabtree
Supply and fix in repairs moduler fan Requlator, 120 W-2 modules
Supply and fix in repair Door bell electronic, music type, 230 volt AC. Make : Anchor/Leader/Legrand/Crabtree
Supply and fix in repair Fan capacitor 2.5/3.15 mfd suitable for 1200/1400mm sweep ceiling fan. Make : Anchor/Leader/Legrand/Crabtree
Supply and fix in repair Fan regulator electronic, step & socket type 230 volt, suitable for 1200/1400mm sweep ceiling fan. Make : Anchor/Leader/Legrand/Crabtree
Taking down old un serviceable/serviceable light fittings of any type from wall all as directed by Engr in Charge
S&F in replacement LED tube light fitting of 10 watts 6000K , 230 volt, with aluminium extruded channel powder coated with diffuser for glare free light complete with all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge. Make : Shakti/Crompton Greaves/Bajaj/Wipro/Philips
S&F in replacement LED tube light fitting of 20 watts 6000K , 230 volt, with aluminium extruded channel powder coated with diffuser for glare free light complete with all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge. Make : Havells/Crompton Greaves/Bajaj/C&S/Philips
S&F inrepair bldg security light light fittings 1x 20 Watt LED street light with cast aluminium housing, toughened flass diffuser, IP65/66 and wired with all accessories and including connection up with twine core twisted flexible copper conductor cable with 1.5 M long suitable size all as specified and directed. Make : Shakti/Crompton Greaves/Bajaj/Wipro/Philips
S&F in replacement security light bracket made out of 25 mm bore GI Light grade 1.00 M long to required shape as in bracket for steet light fittings fixed with two pair of MS flate iron clamp of size 50mm X 6 mm thickness of required shape with nuts, bolts and washers suitable for steel tubular pole including painting of mild steel flate iron surface with two coates of synthetic enamel paint over a coat of red oxide primer complete including taking down unserviceable one all as specified and directed.
Supply and fix in repair 30 watt LED Light 2' x 2' LED luminare with polymer diffuser complete with accessories suitable for armstrong/Grid ceiling with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. Make : Shakti/Crompton Greaves/Bajaj/Wipro/Philips
Supply and fix in replacement Sheet metal enclosure (ISI marked) distribution board TPN, 415 volts, 4 way horizontal type double door type, 200 Amps rated neutral copper bus bar for housing MCB and fixed and tested on completion complete all as specified.
Supply and fix in replacement Sheet metal enclosure (ISI marked) distribution board for 240 volts, SPN 4 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete all as directed.
All as per item No 37 here-in before but SPN 8 ways DB.
Supply and fix in replacement MCB single pole 6 to 32 Amps 240 volts, C series, 10 kA rupturing capacity
Supply and fix in replacement MCB single pole & neutral 40 Amps 240 volts, C series,10 kA rupturing capacity
Supply and fix in replacement MCB Tripple pole & neutral 32 to 63 Amps 240 volts, C series,10 kA rupturing capacity providing in DB complete all as specified.
Supply and fix in replacement Isolator TPN 100A, 415volts
Supply and fix in replacement Sub main wiring with 2 runs of 4.0 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in existing non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. NOTE:- Two run of wiring cable, one run of earth wire and one run of PVC conduit shall be measured as one unit RM.
Supply and fix in replacement Sub main wiring with 2 runs of 6.0 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in existing non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. NOTE:- Two run of wiring cable, one run of earth wire and one run of PVC conduit shall be measured as one unit RM.
S & F in repair Supply only ballast electronic type for 1x28 Watt FTL/CFL complete all as directed. Make Havells/Bajaj/Crompton
S & F in repair Supply only ballast electronic type for 1x36 Watt FTL/CFL complete all as directed. Make Havells/Bajaj/Crompton
S & F in repair florecsent tube rod 1x28 Watt, 6000K, high efficiency /high out put complete all as directed. Make Havells/Bajaj/Crompton
S & F in repair florecsent tube rod 1x36 Watt, 6000K, high efficiency /high out put complete all as directed. Make Havells/Bajaj/Crompton
Taking down ceiling/exhaust fan dismantling and painting of ceiling/exhaust fan complete at site with synthetic enamel paint by spraying incl (fittings with filler) one coat after cleaning all dust etc incl connecting up. Provn of twin core cable of suitable size for ceiling rose to connector connecting of earth wire incl replacement of fan capacitor 2.5/3.15 MFD,canopy, bearing/bush, rubber bushes minor nuts bolts screws washers greassing in fan bearing & refix same complete all as directed
Rewinding of Exhaust fan with appropriate size of copper enamelled wire including varnishing ,heating with proper insulation complete and testing all as specified and directed .
Rewinding of ceiling fan with appropriate size of copper enamelled wire including varnishing ,heating with proper insulation complete and testing all as specified and directed .
Taking down of storage water heater (Geyser) of any capacity from existing position by disconnecting from water supply pipe line and electric connection main to carryout necessary repair or to deposit to E/M store yard as directed including refixing after repair in same location/position and making electric & water connections complete all as directed by the Eng-in-charge.
M & L for opening of storage water heater (Geyser) any size/capacity & make and taking out inner tank from geyser body, brazing inner tank with suitable welding rod, testing of inner tank for leakage under water pressure after brazing, re-assembling geyser including repair/replacement of worn out rubber gaske,t nuts, bolts etc refixing in the same/other location and testing on completion all as directed by the Eng-in-charge.
Supply & fix in replacement thermostat suitable for any type of 25 - 50 ltr capacities geyser bearing ISI Marked complete all as directed.
Supply & fix in replacement 2.5 KW capacity of heating element of geyser with thermostat slot of any size bearing ISI marked complete all as directed. MAKE :- VENUS model No 025VLM of equivelant of make as approved by GE.
Supply & fix in replacement indicator lamp red/green square/round/rectangular shape suitable for any type/capacity of geyser complete all as directed.or geyser.
Supply & fix in replacement of stud bolt with nuts and washers set of three by brazing on inner tank of geyser complete all as directed.or geyser.
Supply & fix in replacement PVC connection pipes 15mm dia for hot / cold water supply with brass adopters 600 mm long complete all as directed.
Supply & fix in replacement Plug top 3 pin 15A bearing ISI marked. Make: Anchor/Kinjal/Plaza
Supply and fix in replacement of hanger bolt 100mm long and 12 mm dia for mounting of geysers
M&L, Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.0mm thick buried directly in ground (earth pit depth not less than 2.25m deep below the ground level) with top edge of earth plate at a depth not less than 1.5m below ground level connected to earth using GI earth wire of 6mm dia by means of of nuts, bolts and washer and check nuts of GI or steel as shown in electrical plate No.3 of MES SSR-2009 (Part-I) and connected to earth test point all as specified or indicated including testing on completion with and including 15mm bore light grade GI protection pipe 7.5 metre long for earth including PCC (1:2:4) pit with RCC (1:2:4) type B-1 cover, 40mm thick reinforced with 6mm dia MS bars @ 100mm both ways with lifting hooks made out of 6mm dia MS bars, watering arrangement with 20mm dia light grade pipe, funnel, wire mesh, common salt chorcoal, necessary excavation and earth work in any type of soil complete all as specified.
RRK PROJECTS
kamadhenu Electricals
Chandana Enterprises
RAINBOW ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .