| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹31.4 LAccepted-AOC 1170 BENGALI MOHALLA NEAR PRABHAKAR HOSPITAL AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | ₹31.4 L | 1 | Accepted-AOC LOWEST AND REASONABLE |
| 2 | 2₹31.6 L+₹19,321.03 (0.62%)Rejected-Finance H NO 597 SEONA ROAD RANJIT NAGAR PATIALA PB 147001 | PATIALA | PATIALA | PUNJAB | 147001 | ₹31.6 L+₹19,321.03 (0.62%) | 2 | Rejected-Finance NOT LOWEST |
| 3 | 3₹33.7 L+₹2.3 L (7.36%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹33.7 L+₹2.3 L (7.36%) | 3 | Rejected-Finance NOT LOWEST |
| 4 | 4₹38.3 L+₹7.0 L (22.3%)Rejected-Finance | ₹38.3 L+₹7.0 L (22.3%) | 4 | Rejected-Finance NOT LOWEST |
| 5 | 5₹38.8 L+₹7.4 L (23.7%)Rejected-Finance 24 A RAGHBIR MARG NEAR 22 NO PHATAK PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | ₹38.8 L+₹7.4 L (23.7%) | 5 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹96,600
Closing Date
23 Dec 2021, 6:00 pmClosed
MAJOR ANIMESH TRIPATHI
GE NORTH PATIALA MILITARY ENGINEER SERVICES SANGRUR ROAD PATIALA CANTT
REPAIR MAINTENANCE OF LT UNDERGROUND CABLES LT PANELS POLE FEEDER PILLER BOARDS AND ALLIED WORKS AT NEW CANTT UNDER GE N PATIALA
2021_MES_489874_1
GE(N)/PAT-54/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
PATIALA
AS PER NIT
8 documents required · 8 mandatory
₹500
GE NORTH PATIALA
₹96,600
Yes
21 Jan 2022
23 Nov 2021
25 Dec 2021
23 Nov 2021
23 Dec 2021
7 Dec 2021
Amount
Surface excavation not exceeding 30 cm and averaging 15 cm deep and getting out in soft/loose soil including removing green vegetation, roots, bushes,etc from surrounding of LT feeder Boards/Poles/substations etc complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1,5 mtr in depth for laying of cables errecting of pole including getting out in any kind of soil complete all as specified and directed.
All as per item No. 02 here-in-above but exceeding more than 1.5 m in depth complete all as specified and directed.
Returning filling in including spreading, levelling, and well ramming, in layers not exceeding 25 cm each layer of any kind of soil complete all as specified and directed.
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Clean dry sand laid in trenches/ducts for bedding and cushioning to cable, including spreading and leveling complete all as specified and directed. Note:-(i) Consolidated/punned sand shall be considered for purpose of payment.(ii) Sand shall be same as specified for plastering work.
Taking up or down 10 sqmm 2 core worn out/ damaged / partly serviceable/unserviceable PVC insulated underground cable, armoured, heavy duty with aluminium conductors 1100 volt grade from trench including taking out unserviceable bricks,pipes etc testing of cable in the presence of Engr-in-charge to ascertain seviceability,seggregating serviceable and unserviceable cable and keeping in safe custody the serviceable portion for reuse, stocking serviceable bricks for reuse complete all as specified and directed. (Note: Earth work shall be measured and paid separately under relevant item of Sch 'A' ).
All as per item No. 07 here-in before but for cable of size 4 core 10 sqmm.
All as per item No. 07 here-in before but for cable of size 4 core 16 sqmm.
All as per item No. 07 here-in before but for cable of size 4 core 25 sqmm.
All as per item No. 07 here-in before but for cable of size 4 core 35 sqmm.
All as per item No. 07 here-in before but for cable of size 3.5 core 50 sqmm.
All as per item No. 07 here-in before but cable of size 3.5 core 185 sqmm.
Taking up or down worn out/ damaged / partly serviceable/unserviceable PVC insulated underground cable, armoured, heavy duty with aluminium conductors of size 10 sqmm x 2 core,1100 volt grade from duct/pole/wall/roof tops etc, testing of cable in the presence of Engr-in-charge to ascertain seviceability,seggregating serviceable and unserviceable cable, keeping aside serviceable and unserviceable cable complete all as specified and directed .
All as per item No. 14 here-in before but cable of size 4 core 10 sqmm.
All as per item No. 14 here-in before but for cable of size 4 core 16 sqmm.
All as per item No. 14 here-in before but for cable of size 4 core 25 sqmm.
All as per item No. 14 here-in before but for cable of size 4 core 35 sqmm.
All as per item No. 14 here-in before but for cable of size 3.5 core 50 sqmm.
All as per item No. 14 here-in before but cable of size 3.5 core 185 sqmm.
Supply,laying, commissioning and testing or passing through pipe, XLPE insulated, armoured, electric power UG cable (Heavy duty) with aluminium conductor, 1100 volts grade in duct / trenches for small length for extension/replacement of the defective cable of nominal cross sectional area 10 sqmm 2.0 core including brass compression cable gland, terminal aluminium lugs etc making connection and testing complete all as specified and directed. Note :-(i) Pipes and bricks for protection, mild steel clamp nut and bolts sand cushioning shall be measured and paid separately
All as per item No. 21 here-in before but cable of size 4 core 10 sqmm.
All as per item No. 21 here-in before but for cable of size 4 core 16 sqmm.
All as per item No. 21 here-in before but for cable of size 4 core 25 sqmm.
All as per item No. 21 here-in before but for cable of size 4 core 35 sqmm.
All as per item No. 21 here-in before but for cable of size 3.5 core 50 sqmm.
All as per item No. 21 here-in before but cable of size 3.5 core 185 sqmm.
Laying, commissioning and testing or passing through pipe, XLPE insulated, armoured, electric power UG cable (Heavy duty) with aluminium conductor, 1100 volts grade in duct / trenches for small length for extension/replacement of the defective cable of nominal cross sectional area 70 sqmm 3.5 core including brass compression cable gland, terminal aluminium lugs etc making connection and testing complete all as specified and directed. Note :- UG cable will be issued under Sch `B' free for fixing/laying from AGE E/M (N) Patiala (ii) Excavation, Pipes and bricks for protection, mild steel clamp nut and bolts sand cushioning shall be measured and paid separately
All as per item No. 28 here-in before but of size 3.5 core 95 sqmm.
All as per item No. 28 here-in before but of size 3.5 core 120 sqmm.
M & L for precast concrete cable covers type 2 flat, size 250mmx150mmx40mm laid dry in trenches for cable protection complete all as specified and directed.
Taking down carefully galvanized iron steel wire drawn straight horizontal as continuous earth wire on existing LT poles of size 4.0 mm dia from LT over head lines, after unbinding from insulators for replacement incl Restringing/ restretching to dismantled serviceable G I wire complete all as specified and directed. Note:- (i)Replaced G I wire shall be measured and paid under respective item supply only of sch for measurement length of each wire shall be taken separately.
Supply only galvanized iron steel wire drawn straight/ horizontal as continuous earth wire on existing LT poles of size 4.0 mm dia complete all as specified and directed.
M&L for Dismantling insulators any type, any size from LT poles complete all as specified and directed.
M&L for Dismantling cross-arms of M.S. channel or angle sections etc from LT poles complete all as specified and directed.
M&L for Cross arms bracing supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shapes or sizes as indicated or directed and inclusive of one primer coat,one under coat and one finishing coat of paint complete all as specified and directed.
M & L for Stay assembly in replacement complete with accessories as shown in electrical plate No. 1 complete all as specified and directed. Note:- (loop type insulator, stay clamps, excavation and concrete measured separately
Supply and fix in replacement of stay wire galvanized iron stranded of size 7/3.15 mm,length of stay wire not exceeding 11 mtrs with each stay and fixed to stay and pole including tightening complete all as specified and directed.
Supply and fixing in replacement of loop type insulators porclain shackle type vitreous white, brown or green of size 65x90mm overall dimension and 20mm clearence hole all as specified and directed.
M&L for Dismantling of ACSR conductors after unbinding from insulators Note:- (i) Total no of conductors in over head line to be taken down shall comprise a maximum of three phase, one neutral ,one street light/security light for measurement length of each conductor shall be taken separately .All as specified and directed by Engineer in Charge.
Supply and fix in replacement of ACSR conductor weasel (6/1/2.59 mm) to be drawn straight horizontal on over head lines on existing poles including binding with insulators. Weight of conductor shall be measured straight horizontal distance between centre of two adjacent poles and calculating weight of conductor of size and length by adding 3% extra for sag ,jointing jumpers,etc complete all as specified and directed.
M&L for Painting to existing PCC pole of any type with Black and yellow synthetic enamel paint over existing paint up to 1.5 m height from bottom alternatively strips 30 cm each including painting of ,clamps, nut, bolts with aluminum paint including providing pole number with white enamel paint and 100 mm dia (round) background of blue enamel paint at site complete all as directed.
M&L for Paint to existing steel tubular pole of any type complete with two coat of aluminium synthetic enamel paint from bottom to top of the pole inculding black and yellow paint upto 1.5 Mtr height from bottom alernaterely strip 30 cm each including providing pole number with white enamel paint and 100 mm dia (round) background of blue enamel paint at site complete all as directed.
M&L Paint to existing LT panel board of any type complete with two coat of weather proof synthetic enamel spray paint over a coat of red oxide primer after preperation of the surface complete all as directed.
Supply and fix in repair chain link fencing with post and door frame arrangement for LT panel/two pole structure/four pole structure/etc of height 7 feet complete all as specified and directed.
M&L for streching and tightning of existing ACSR conductor any size on LT pole 9 mtr long all as specified (one span consists of 5 ACSR conductors 1 earth wire and cradle guard) includind replacement of J hooks complete all as specified and directed.
M&L for replacement of shackle type porcelain vitreous, white brown or green insulator for working pressure 1.1 kv of size 100mm height and 115 mm dia including galvanized mild steel straps of section 38 x 5 mm size ,20 mm dia bolt nut and washers complete all as specified and directed .
Supply and fix LT spacer 02 way spiral type made out of PVC material and suitable to work on 1100 volts fixed between 02 conductors in any position along the LT line for any size of conductor along the feeder complete all as specified and directed.Make : Denson,Modern,
Supply and fix LT spacer 04 way spiral type made out of PVC material and suitable to work on 1100 volts fixed between 04 conductors in any position along the LT line for any size of conductor along the feeder complete all as specified and directed.Make : Denson,Modern
Supply and fix LT spacer 05 way spiral type made out of PVC material and suitable to work on 1100 volts fixed between 05 conductors in any position along the LT line for any size of conductor along the feeder complete all as specified and directed.Make : Denson,Modern,
Supply and fix cable lugs aluminium any type suitable for cable up to 70 sqmm including necessary crimping with crimping tool complete all as specified and directed .
All as per item 51 here-in-above but of size up to 120 sqmm.
All as per item 51 here-in-above but of size up to 150 sqmm.
All as per item 51 here-in-above but of size up to 240 sqmm.
All as per item 51 here-in-above but of size up to 300 sqmm.
M&L for replacement existing worn out /over heated/ multi-jointed ACSR jumpers of LT over head lines with and incl XLPE/PVC insulated 1100 volts multi stranded aluminium conductor single core cable of size 120 sqmm as per colour code in sequence Red ,yellow ,blue and black for neutral incl winding with ACSR conductors with suitable size aluminium binding wire complete all as specified and directed . (Length of one jumper not exceeding more than 2.0 mtrs).
M&L for replacement existing worn out /over heated/ multi-jointed ACSR jumpers of LT over head lines with and incl XLPE/PVC insulated 1100 volts multi stranded aluminium conductor single core cable of size 240 sqmm as per colour code in sequence Red ,yellow ,blue and black for neutral incl winding with ACSR conductors with suitable size aluminium binding wire complete all as specified and directed .(Length of one jumper not exceeding more than 2.0 mtrs .
S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 63 Amps 3 Pole breaking capacity at 415 volt AC 50 Hz 25 kA complete all as specified and directed.
S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 63 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 25 kA complete all as specified and directed.
S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 100 Amps 3 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed.
S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 160 Amps 3 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed.
S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 160 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed.
S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 200 Amps 3 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed.
S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 200 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed.
S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 250 Amps 3 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed.
S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 250 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed.
S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 400 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed.
S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 630 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed.
Supply and fix danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white ,with letters and conventional skull and bone in postal red color and fixed with flat iron clamps, nuts, bolts , and washers of size 200mmx 150 mm for LT complete all as specified and as directed. (Note:-the printing shall be hand written only stancils embossing shall not be allowed ,and size of letter shall be 50x10 mm (height x width .)
S&F in LT Air Circuit Breaker 4 Pole, 415V, with Thermal Magnetic Release (Manual Draw out type) of capacity 630 Amps complete all as specified and as directed.
S&F in LT Air Circuit Breaker 4 Pole, 415V, with Thermal Magnetic Release (Manual Draw out type) of capacity 800 Amps complete all as specified and as directed.
Demolition of concrete of any description and in any position not otherwise specially provided for complete all as directed.
Earthing complete with Galvanized steel earth plate 600 x 600 x 6.0 mm buried directly in ground (earth pit not less then 2.25 Mtr deep below ground level) with top edge of the plate not less then 1.5 Mtr below normal ground level connected to GI strip of size 32X6 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel incl excavation and earth work, GI pipe light grade 25mm/40 mm bore for protection of GI wire /strip from earth electrode to and incl the supplying and lying charcoal dust, common salt, PCC 1:3:6 type CI (using 20 mm graded crushed stone aggregate) as in chamber and MS angle iron frame 40 x 40 x 3mm and RCC cover 40 mm thick 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) reinforced with 8 mm dia. TMT bars @ 75mm c/c both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No. 3 of SSR Part I of 2009 and connected to earth test point incl testing complete all as specified and directed
M &l for PCC 1:4:8 TYPE D-2 using 40 mm graded broken stone aggregate as in mass concrete in foundations etc . complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded broken stone aggregate as in mass concrete in foundations etc complete all as specified and directed .
Material and labour for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate for coping around the pole strut above ground level, foundation of stay etc. including neccassory form work and finishing the surface fair and even without using extra cement all as directed and specified
Repair to LT panel box/body by repalcing the damaged/rusted MS sheet of existing gauge fabricated cut to size of original length incl providing hinges and other hard ware item like handless etc.
Meterial and labour for making locking provision to the LT panel board of any size/type by providing MS flat iron 25x6 mm up to lengh 15cm duly welded to the both front and back door duly holed for making provision for lock including welding of brocken/unserviceable hinges/mounting arrangements of doors and matching with enamel paint of existing colour on the disturbed surfaces and providing pad lock not less than 75mm with triplicate key complete all as specified and directed. Make of pad lock: Harrison/Navta/Godrej
S&F in replacement of volt meter 100x100 mm squre type digital 0-600 Volts complete all as specified and directed. Make AE/SIEMENS
S&F in replacement of Ampere meter 100x100 mm squasre type digital 0-800 Amp complete all as specified and directed. Make AE/SIEMENS/
Suppling and fixing of LT CTs 60 Amps up to 200 Amps current rasting 415 volts complete all as specified and directed.
All as per item no. 82 here-in-above but for 200 Amps up to 400 Amps current rating 415 volts complete all as specified and directed.
All as per item no. 82 here-in-above but for 400 Amps and up to 800 Amps current rating 415 Volts complete all as specified and directed.
Supply & fixing LED type indicator Red, Yellow, Blue complete with base and connection complete all as specified and directed.
M&L cable jointing kit for 1100 Volt grade cable heat shrink type joint complete with jointing meterial and ascessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to 150 sqmm complete all as specified and directed.
M&L cable jointing kit for 1100 Vgrade cable for indoor type heat shrink type joint complete with jointing meterial and ascessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sqmm to 400sqmm complete all as specified and directed.
Supply,laying,galvanised steel tubing light grade complete ith all fitting of size 40 mm dia for cable protection along with pole across road etc. Complete all as specified and directed.
All as per item Ser No 88 above but size of pipe 80 mm dia
Supply installation, testing and commissioning LT Feeder piller board out door type cubicle panel board suitable for 3 phase,4 wire 415 volt 50 hz factory febricated approved CPRI powder coated made out of 3.15 mm thick CRCA sheet and MS angle iron sectiom 40X40X6mm frame with front and back openable double door system with locking arragement louver and air vent gaket for netural flow of air with conopy, inner compartment made out of 2 mm the CRCA sheet duly compartmentalized for each MCCB of incoming and outgoing with lockable arragement with aluminium bus bar three phase and neutral of capacity of 400 amp marked red, yelllow, black and blue inslulators, made of high strength insulated material suitable 1100 voltage all controll PVC wires shall be with 2.5 sq mm multistrand copper conductor and shall be properly bunched, tied, frerruled for proper indication , fixed on PCC foundation complete. Note:- PCC shall be measured and paid separately
Supply installation, testing and commissioning LT Feeder piller board out door type cubicle panel board suitable for 3 phase,4 wire 415 volt 50 hz factory febricated approved CPRI powder coated made out of 3.15 mm thick CRCA sheet and MS angle iron sectiom 40X40X6mm frame with front and back openable double door system with locking arragement louver and air vent gaket for netural flow of air with conopy, inner compartment made out of 2 mm the CRCA sheet duly compartmentalized for each MCCB of incoming and outgoing with lockable arragement with alluminium bus bar three phase and neutral of capacity of 600 amp marked red, yelllow, black and blue inslulators, made of high strength insulated material suitable 1100 voltage all controll PVC wires shall be with 2.5 sq mm multistrand copper conductor and shall be properly bunched, tied, frerruled for proper indication , fixed on PCC foundation complete. Note:- PCC shall be measured and paid separately
Supply installation, testing and commissioning LT Feeder piller board out door type cubicle panel board suitable for 3 phase,4 wire 415 volt 50 hz factory febricated approved CPRI powder coated made out of 3.15 mm thick CRCA sheet and MS angle iron sectiom 40X40X6mm frame with front and back openable double door system with locking arragement louver and air vent gaket for netural flow of air with conopy, inner compartment made out of 2 mm the CRCA sheet duly compartmentalized for each MCCB of incoming and outgoing with lockable arragement with aluminium bus bar three phase and neutral of capacity of 400 amp marked red, yelllow, black and blue inslulators, made of high strength insulated material suitable 1100 voltage all controll PVC wires shall be with 2.5 sq mm multistrand copper conductor and shall be properly bunched, tied, frerruled for proper indication , fixed on PCC foundation complete. Note:- PCC shall be measured and paid separately
Supply installation, testing and commissioning LT Feeder piller board out door type cubicle panel board suitable for 3 phase,4 wire 415 volt 50 hz factory febricated approved CPRI powder coated made out of 3.15 mm thick CRCA sheet and MS angle iron sectiom 40X40X6mm frame with front and back openable double door system with locking arragement louver and air vent gaket for netural flow of air with conopy, inner compartment made out of 2 mm the CRCA sheet duly compartmentalized for each MCCB of incoming and outgoing with lockable arragement with alluminium bus bar three phase and neutral of capacity of 600 amp marked red, yelllow, black and blue inslulators, made of high strength insulated material suitable 1100 voltage all controll PVC wires shall be with 2.5 sq mm multistrand copper conductor and shall be properly bunched, tied, frerruled for proper indication , fixed on PCC foundation complete. Note:- PCC shall be measured and paid separately
Suppy and fix rigid non-metallic PVC conduit 20 mm dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.
Supply and fixing street light sintex box of size 300 mm x 200 mm x 105 mm, made out of FRP sheet with weather proof hinged door including self locking arrangement, out door type weather and vermin proof complete comprising of insulated / high quality PVC sleeves aluminium bus bar of capacity 63 Amps 04 Nos (three phase RBY and black for neutral) with and including 6 Apms MCB single pole, single phase 230 volts, including 25 x 3 mm flat iron mounted on insulators, having arrangement of connecting incoming and outgoing cables complete and all as specified and directed.
Supply and fixiing PVC insulated round/flat copper cable of size 3 core, 2.5 Sqmm for connection of LED lights from FRP junction box to street light fitting complete all as specified and directed.
Boring of holes under road, pavement, hard standing by trench-less technology using ultrasound technique and necessary machine suitable to pass through 40 to 80 mm bore GI tubing and cable etc complete all as specified and directed.
Jawandha Enterprises
R D Bansal
JASSI TRADERS
MAHESH KUMAR SINGLA CONTRACTOR
m/s s.n. builders
Shivam Engg and fabricators
Arneja Builders
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .