Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.1 LAccepted-AOC | L1 | Accepted-AOC lowest | |
| 2 | L2₹14.7 L+₹3.5 L (31.7%)Rejected-Finance 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹15.7 L+₹4.6 L (40.9%)Rejected-Finance BOOTH NO 56 MAIN MARKET SECTOR 40 C CHANDIGARH U T 160036 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160036 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹18.8 L+₹7.6 L (68.6%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹19.1 L+₹8.0 L (71.6%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹20.9 L
EMD Value
₹41,900
Closing Date
21 Jun 2024, 6:00 pmClosed
AGE (I) AF STATION AMRITSAR
ASST. GARRISON ENGINEER (I) AIR FORCE STATION AMRITSAR- 143001
PROVN OF WORK SERVICES FOR FIRE SAFETY AND UPGRADATION OF OTM BUILDINGS INCLUDING OTHER SANCTIONED WORKS AT AF STATION AMRITSAR UNDER AGE (I) AF AMRITSAR
2024_MES_655611_1
AGE (I) AF/ASR/T-05/2024-2025
Open Tender
Civil Works
Item Rate
270 days
AGE (I) AF STATION AMRITSAR
Class E and Category a(i)
8 documents required · 8 mandatory
₹500
Yes
AGE (I) AF STATION AMRITSAR
₹41,900
Yes
1 Oct 2024
24 May 2024
28 Jun 2024
24 May 2024
21 Jun 2024
7 Jun 2024
Amount
Dismantling of wall & ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets, complete all as specified and directed.
S&F fire resistant 12-13 mm wall/ceiling/partitions incl frame work complied with BS: 476 part 4, 6 & 7 having fire resistant ranging from 30 to 60 minutes when fixed to walls partitions, false ceilings, shaft walls, beams and columns encasement with minimum essential joints & covering of joints using jointing compound to give clean look and size as per manufacturer instructions. The board shall be gypsum plaster board with glass fibre incl additives. The fire resistant board shall be enti sag installated on and incl GI framing/ grid system / suspensation of make same of the board approved complete all as specified and directed by Engr-in-charge.
M&L for prepartion of old wooden surface of any description not other wise described, over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old steel painted surface of any description not other wise described, over 10cm width or girth and applying two coats of synthetic enamel, complete all as specified and directed.
S & F Curtain rails harrison rails steel chromium plated with fixing brackets stop roller etc, complete all as specified and directed.
S & F Hat and coat hooks Aluminium solid body, 175 mm to 250 mm and fixed, complete all as specified and directed.
S&F 4mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed.
S & F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples , complete all as specified and directed.
M&L and fabrication of mild steel work as in posts, purlins,crane gantires, rafter ,rails,wind tie nut & bolt etc and fasteningsetc and heavy brackets framing (MS tube, beam,tee,angle,channels,flat section etc and other sections) including distance pieces,cleats etc Fe-290 (Gde E165) complete all as specified and directed .
Taking down carefully copper / aluminum point wiring (light, fan, socket or power) complete with fittings such as switches, ceiling roses, pendants, lamp holders, bracket, light fittings, bulk head fittings, tube light fittings etc. and making good disturbed surfaces of walls, floors etc as per existing complete all as specified and directed.
Material and labour for Point wiring for One light / Celing fan/ Exhaust fan point/Bell point, controlled by one switch 5 Amp SP one-way complete with 1.5 Sq mm (nominal area) PVC insulated, unsheathed and multi strand copper conductor FRLS cable (ISI marked) drawn into and including in Stove enamelled steel and conduit fittings including 1.5 Sq mm PVC insulated unsheathed and multi stranded copper conductor FRLS cable as earth wire to common earth and connecting to earth dolly including MS sunken box covered with modular cover with frame and machine made brass screw and washers etc complete all as specified and directed Notes;- (i) For Internal wiring colour to be used as per IE rule for Phase - Red/Yellow/Blue, Neutral - Black and Earth – Green (iv) Making good on disturbed surfaces and quoted rate including M&L for white/colour wash (existing colour) to macth with existing surfaces, complete as directed by Engineer-in-Charge (ii) Switch/socket to be measured and paid separately.
(a) For one light/fan/bell point controlled by one 6 Amp one way switch
(a) All as per item No. 2 hereinbefore but wiring for one 3 pin 6 Ampere socket outlet point on the same board, controlled by other switch complete all as specified and directed.
(c) All as per item No. 2 hereinbefore but wiring for one 3 pin socket outlet 6 amps independent board.
M&L flame proof, Zone I & II , Gas Group II A/ II B, weather proof poit wiring for one light or fan point controlled by one switch using approved colour coding as per IS with zero halogen flame retardent (HFFR) smoke free non toxic non corrosive PVC insulated unsheated flexible copper conductor cable 1.5 sq mm (nominal area) single core 1100 volts grade in and including (ERW) stove enamelled conduit heavy duty ISI marked duly welded, flame proof weather proof junction box , tee, bends, inspection bends etc all as required including PVC insulated unsheated flexible copper conductor cable 1.5 Sq mm (nominal area) single core 1100 volts grade as earth continuity conductor complete all as specified and directed
Material and labour in repair for Point wiring for one 5 pin socket outlet 16 amps independent board, controlled by one switch 15 Amp one-way complete with 2.5 Sq mm (nominal area) PVC insulated, unsheathed and multi strand copper conductor FRLS cable (ISI marked) drawn into and including stove enamelled steel conduit and conduit fittings including 2.5 Sq mm PVC insulated unsheathed and multi stranded copper conductor FRLS cable as earth wire to common earth and connecting to earth dolly including MS sunken box covered with modular cover with frame sheet top cover and machine made brass screw and washers etc complete all as specified and directed by Engr-in-Charge Note : Colour Code shall be maintained as per IE Rules
S & F modular type switch 6 Amps, one way one module complete all as specified.
S & F modular type switch 6/16 Amps, one way one module complete all as specified.
S & F Modular Type Socket outlet, 6 Amps, 2/3 pin combined 2 module complete all as specified.
S & F Modular Type Socket outlet, 6/16 Amps,combined 2 module complete all as specified.
M&L for sub main wiring two single core 6 Sqmm(nominal area) multi-strand copper conductor FRLS PVC insulated and unseathed cable drawn in and including non metalic PVC regid conduit medium grade of suitable size with all standerd fittings, concealed including one run of continous PVC insulated stranded copper conductor FRLS cable 6 Sqmm for earth continuty, including taking out and removal of old sub main wiring, complete all as specified and directed. Note:- Rate quoted shall be deemed to include cutting chases for concealed conduit and making good incement mortar(1:4) or PCC (1:2:4)
Supply and fixing SMD LED panel recess/surface suspended mounting 36 watt 2' x 2' LED ceiling light with extruded aluminium housing and milky diffuser including connecting up with twin core twisted flexible copper conductor cable with suitable size of 170-230 Volts, 50HZ complete all as specified and directed.
Supply and fixing LUMENO LED tube light fitting 1x20 watts with PVC insulated flexible copper cable from ceiling rose to tube light fitting complete all as per specified and directed.
S & F of ceiling rose, surface bakelite, 65 X 50 mm, 3 terminals complete all as specified and directed.
Supply and fix modular fan step regulator,120 Watt - 2 module complete all as specified and directed by Engr-in-chrage.
Supply and fixing sheet metal enclosure, SPN, with a two pin socket and earth plug, with one MCB single pole, 240 Volts, 20 Amps, ‘B’ curve, 10 KA, complete all as specified and directed
S & F sheet metal enclosure for DBs (Double door type) when MCBs to be used single pole and neutral 8 ways including blanking plate as required with 200 Amps rated bus bar, 240 volts fixed sunk/flush to the wall or niche complete all as specified and as directed including necessary brick work and plaster to match with the existing surface complete all as specified.
S & F sheet metal enclosure for DBs (Double door type) when MCBs to be used triple pole and neutral 4 ways including blanking plate as required with 200 Amps rated bus bar, 415 volts fixed sunk/flush to the wall or niche complete all as specified and as directed including necessary brick work and plaster to match with the existing surface complete all as specified.
S & F MCB DP, 240 Volts, AC, B curve, 10 KA, 40 Amps (10 KA 'B' rupturing capacity) complete all as specified and as directed
S & F MCB single pole, 240 Volts, AC, B curve, 10 KA, 6 to 32 Amps (10 KA 'B' rupturing capacity) complete all as specified and as directed
S & F sheet metal enclosure 63 Amp Triple pole and earth encolsure with a three pin and earth plug with socket complete withone triple pole MCB
S & F Change over switch of split type AC 1.5/2 Ton with all fitting and fixture complete all as specified and directed by Engr-in-Charge
Taking down old ceiling fan/wall mounted fan, sealing cable end, dismantling blades and removing fan and blades to store for repair and servicing as specified and directed by Engr-in-Charge(Fan shall be deposited to MES Store after repair)
Painting of ceiling fans/wall mounted fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dusts
Hanging old ceiling fan/wall mounted fans after repair, painting and connecting up including provision of cable from ceiling rose or connector to fan as specified and directed (Fan shall be collected from MES Store yard)
Taking down existing outdoor / indoor unit split type and window type AC of any capacity alongwith change over switch shifting from existing position to other location including civil repair work, copper pipe, PVC pipe and other material requirement at site, complete with making good disturbed surface of wall by providing brickwork, plastering colour so as to match with the colour of existing wall and necessary arrangement for refixing of AC after servicing, complete all as specified and directed by Engr-in-Charge Note: Any damage occurs during shifting and Re-fixing of the item, the cost of repair will be paid by the contractor itself not by the department.
Supply & fixing for fire alarm system consisting of Photoelectric type Smoke detectors, with 2 x 1.5 volt AA battery and wiring, checking complete wiring and smoke detector all as specified and directed by Engr-in-Charge
S&F of flame proof Exaust fan Heavy duty (300mm sweep), 230V, 1440 RPM, 1120CFM wall mounted/window mounted metal body type and including with all fixing arrangement fixed to wall with suitable size opening and mounting ring and louvrecomplete with all accessories pre-wired and including connection, complete all as specified & directed.
Taking down existing Fire alarm control panel and hooter complying with BSEN 54 Single loop panel of capacity from 99 detectors & 99 modules upto 200 detector and modules shifting from existing position to other location including civil repair work and other connected accessories for re-fixing after servicing complete all as specified and directed by Engr-in Charge. Note: Any damage occurs during shifting and Re-fixing of the item, the cost of repair will be paid by the contractor itself not by the department.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanised iron wire 4mm dia as earthing lead by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade ) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 5 of SSR PT 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point complete all as specified & testing on completion as specified & directed by Engr-in-Charge.
Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep for laying of cables and foundation of poles etc. and getting out complete all as spceified and directed.
Returning, filling in trenches (soil) including spreading leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Removal of surplus excavation soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L sand cushioning with a layer of dry river sand 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts complete all as specified and directed Note: Punned down thickness (overall 18cm), shall be considered for measurement and payment.
M&L, locally available , sub class 'B' bricks (old size) laid flat and dry in trenches over the cable for protectionprependicular to the direction of cable adjacent to each other complete all as specified and directed.
Supply , laying,testing and commissioning, LT under gound cables XLPE insulated screened PVC bedded galvanized steel strip armoured electric power cable (heavy duty) with alumininum conductor cross sectional area 35 Sqmm 3.5 core LT, 1100 volts grade , laid in trenches , along poles or passing with through pipe or laid under floor or through/ on walls etc, complete all as specified and directed by Engr-in-charge
M&L, GI pipe light grade 40 mm dia bore for cable protection fixed to pole or under road/ pavement, complete including MS clamps, nuts, bolts etc all as specified and directed by Engr-in-charge
M & L for vertical type sheet steel enclouser distribution boards, double door in replacement factory made 3 phase 415 volts 4 way with 200 amps rating copper bus bar of suitable size and PVC insulated copper jumpers from the MCCB to the out going circuits (one incoming MCCB and 12 outgoing MCBs circuits) comprising of 3 phase 4 wire of suitable rating including MCCB 125 amps, 25 KA, TP, 415 volts, 50 Hz = 01 No. and 12 Nos MCBs 6-32 Amps, complete all as specified and directed.
Supply installation, testing and commissioning, High wall split type AC unit of capacity 1.5 TR, 5 star rating with EER 3.2, electric driven, single phase, indoor and outdoor unit, with cordless remote control and with inbuilt air ionizer and plasma filter for better indoor air quality, necessary suction and discharge copper pipelines from inner units duly insulated including welding brazing to make leak proof, 25 mm bore PVC pipe of superior quality for drainage of condensed water, including suitable stand for mounting outdoor unit as per manufacture instructions and electrical connections and electric cable from inner to outer unit complete all as specified and directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed.
M&L for two single core sub main wiring 4 Sqmm multi-strand PVC insulated copper conductor cable including PVC insulated copper conductor cable of size 4 Sqmm as cotinuous earth wire connecting to common earth in PVC conduit of suitable size including connections of cable with MCBs or bus bars complete all as specified and directed.
Supply and fix sheet metal encloser single pole and meutral , with two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed
Note: The Total amount shall subject to adjustment of credit for old Materials as per Schedule of Credit.
kapoor and co
L-7 Primewave Communications
M/s AKG Engineers & Contractors
B S TRADERS
AAR KAY BEE ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .