| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.9 LAccepted-AOC 578 AVAS VIKAS JANAKPURI B IZATNAGAR BAREILLY 243122 UP | BAREILLY | UTTAR PRADESH | 243122 | L1 | Accepted-AOC AOC | |
| 2 | L2₹46.8 L+₹22,723 (0.49%)Rejected-Finance | L2 | Rejected-Finance Being Higher bid | |
| 3 | L3₹58.6 L+₹12.0 L (25.7%)Rejected-Finance C 247 1 RAJINDRA NAGAR BAREILLY 243122 UP | BAREILLY | UTTAR PRADESH | 243122 | L3 | Rejected-Finance Being Higher bid |
Tender Value
₹76.2 L
EMD Value
₹1.4 L
Closing Date
12 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Bareilly
HQ, CWE, MES, Station Road, Bareilly
CWE BLY/GE (E) /56 OF 2023- 2024 SPECIAL REPAIRS OF OTM ACCN BLDG NO T-145 AND T-147 INF BN-II AT SHAHJAHANPUR CANTT UNDER GE (EAST) BAREILLY
2024_MES_635585_1
8200/B/774/E8
Open Tender
Civil Works
Item Rate
270 days
Shahjahanpur
As per NIT
6 documents required · 6 mandatory
₹1,000
GE (EAST) Bareilly
₹1.4 L
Yes
15 Mar 2024
3 Jan 2024
14 Feb 2024
3 Jan 2024
12 Feb 2024
25 Jan 2024
Amount
Taking down chowkhats or frames n.exc 1.5 Sqm each (without taking off shutters from frames) complete all as specified and directed.
Taking down of chowkhats or frame exc 1.5 Sqm but n.exc 4.0Sqm (without taking off shutters from the frames) complete all as specified and directed.
S&F 30mm flush shutters,solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S & F framed work as in chowkats or frame of door or gates of angle or other section with gusset plate, rail braces etc complete drilled for fixing of steel sheeting or other covering, doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fiting complete all as specified and directed.
S&F 0.63 mm thick mild steel plain black sheet in hearths, covering to door chowkhats (frames) chullah hoods, water tanks, water troughs, ducts,urinal trough and funnels etc, cut to size,edge beaded if directed, holes punched , including round headed screw, clout nails or rivets and fixed to wood or steel members, etc, with plain 40 mm lap joints or welded / riveted seams including bending, turning up, mitred angle, stopped ends, outlet, etc, complete all as specified and directed.
S&F steel window with pressed steel frame of size 95mmx45mm(thickness of PBI sheet 1.25mm thick) side hung shutter including box type hinges with steel handle and steel peg stay complete with glazed openable shutter with glazing bar (open out side) and wire gauged openable shutter without glazing bar (open inside), devetailed or welded complete all as specified and directed and as per Drg no TD/088 Dated 07 Jan 2002.. Note -(i) Two shutter i.e. wire gauged and glazed shall be fixed in one composite frame and both shutter shall be measured as one unit. (ii) rate for filling of PCC 1:3:6 Type C0 (using 12.50 mm gradedstone aggregate) for frame deemed to be included in quoted rate. (iii) MS grill,wire gauge and glass shall be measured and paid seperately.
S&F steel ventilator with top hung shutter including hinges steel peg stay complete all as specified and directed
M&L framed work such as grills grating etc with end of bars shoulderd and/or riveted welded or forged into spikes.framed guard bars iron doors.ladders framed balusters, walk ways. Railings, frame work of water tanks and similar work conforming to Fe 290.Gde-E-165 complete all as specified and directed.
S&F 3mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 Sqm in each pane complete all as specified and directed.
S& F galvanised mild steel wire clothes 0.56 mm nominal dia of wire and average width of aperture 1.18 mm complete all as specified and as directed.
S&F for 100mm long butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and directed.
S&F mild steel spring for doors 300mm long, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S&F 300mm long mild steel sliding door bolts, bolt or clip type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specifieed and directed.
M&L for 150mm long mild steel pressed handles, oval type, stove enamelled black complete all as specified and directed.
S&F solid PVC door frames of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S. square tube, suppling & fixing in opening complete all as specifed and directed.
S&F factory made solid panel PVC door shutter 30 mm thick (Style) consisiting of frame made out of MS tubes for top & bottom rails M.S. frame shall be covered with heat moulded plain coloured PVC 'C' channel having a PVC sheet strip of 20 mm which stuck inside with solvent cements for stiles and plain colour pvc sheets for top rails, lock rails & bottom rails on either side & as gap insert for top rails & bottom rails panelling of plain colour PVC sheet to be fitted in the MS frame welded /sealed to the stiles & rails with suitable PVC sheets beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing all as specified and directed.
S&F, 200 mm long aluminium anodised barrel barrel tower bolts of extruded section and fixed as specified and as directed.
S&F 100 mm long butt hinges, extruded alminium alloy with galavanised mild steel hinge pin, anodised and fixed , type C-21 complete all as specified and directed.
S&F 125 mm aluminium handles cast type, anodised complete all as specified and as directed.
M&L applying two coats of synthetic enamel paints on new steel surfaces over a coat of red oxide primer including preparation of new surface over 10 cm width or girth complete all as specified and directed.
M&L preparing wood or wood based surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills, sunshade , shelves, lintels, etc and cutting chases for concealed conduit wiring , etc and making good, cutting not exc 10 cm girth complete all as specified and as directed.
S&F 140 mm floor door stopper of aluminium alloy body and tongue , anodised, with hard drawn steel spring, fixed in floor complete all as specified and as directed.
S&F in replacement fancy type curtain rails 25mm dia , mild steel, chormium plated coated with fixing bracket, stops,rollers etc for hangging curtain rod complete all as specified and directed.
Dismantling floor hearth or wall tilling including cement mortar bedding (but not backing ) removing rubbish off the premises etc complete all as specified and directed.
M & L Glazed ceramic coloured tiles in vertical surface 450x300x7mm thick set and jointed in neat cement slurry and pointed in white cement or colour cement over and including 10 mm thick in CM 1:4 complete all as specified and as directed.
M&L providing non- skid glazed ceramic tiles coloured7-8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but n. exc 0.11 sqm as in floor etc set and joited with neat cement slurry and pointed in coloured cement to match coloured tiles over and including 15 mm thick cement screed bed in CM 1:6 complete all as specified and as directed.
M&L for vitrified ceramic tiles light shade 10 mm thick (square/rectanglar) polished area of each tiles not less than 0.36 sqm as in floor etc set and jointed in neat cement slurry over and over and including 15 mm thick screed bed of cement mortar in 1:6 and pointed in white or coloured cement to match coloured tiles complete all as specified
M&L providing vitrified ceramic tiles light shade 10 mm thick (square/rectanglar) polished area of each tiles not less than 0.36 sqm as in dado/skirting etc. set and jointed in neat cement slurry over and including 10 mm thick cement mortar rendering in 1:4 and pointed in white or coloured cement to match coloured tiles complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc and complete all as specified and as directed.
M&L applying by brushing neat cement slurry with 3.0 Kg of cement per sqm and complete all as specified and as directed.
M&L for machine cut mirror polish kota stone slab flooring 20-25mm thick over and including 20mm thick screed bed in CM 1:6 laid and jointed with grey cement slurry mixed with pigmen to match the shad of the slab including rubbing and polishing complete all as specified and directed.
M&L for machine cut mirror polish kota stone slab 20-25mm thick as in risers of steps, skirting, dado etc including rubbing and polishing complete all as specified and directed.
M&L for 20mm(+ 2mm) thick factory polished granite stone slab machine cut , bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone complete all as specified and as directed.
Taking down cement plaster including racking out joints hacking for key and scrubbing down with water etc all as specified and directed.
M&L rendering 12mm thick in cement plaster 1:6 on surfaces fair faces of brick work and surface finished even and smooth without using extra cement all as specified and directed.
M&L rendering 15mm thick in cement plaster 1:4 on surfaces other than fair faces of brick work and surface finished even and smooth without using extra cement complete all as specified and directed.
M&L rendering 5mm thick in cement plaster 1:4 on concrete surfaces as in ceilling all as specified and directed.
M&L for 1 mm thick Wall putty on wall complete all as specified and directed
M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper using Airless spray technology with max working pressure of 3300 PPSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface to achieve excellent application using limited manpower complete all as specified and directed. (Note : - Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer).
M&L for preparation of old plastered surfaces of walls and applying two coats of oil bound distemper using Airless spray technology with max working pressure of 3300 PPSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface to achieve excellent application using limited manpower complete all as specified and directed. (Note : - Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer).
M&L for preparing newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specfied and directed.
M&L for preparing old plastered surfaces of walls and applying two coats of cement base paint complete all as specfied and directed.
M&L for preparing newly plastered surfaces and applying of two coats OBD on ceiling with airless electric sprayers over and including 2 mm coat of wall care putty prepared and sanded with electrically operated sanding machine including complete removal of old finishes including preparation of surface and application to be done through authorised dealer complete all as specified and directed.
M&L for for complete removal of existing treatment and applying of two coat OBD on ceiling with airless electric sprayers over and 2mm thick wall care putty prepared and sanded with electrically operated sanding machine including complete removal of old finishes including preparation of surface and application to be done through authorised dealer complete all as specified and directed.
Demolition of cement concrete (un reinforced) in ground floor and paving n. exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
M&L 75 mm thick PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in sub base floor and finishing the surface fair and even complete all as specified and as directed.
M&L for machine pressed precast concrete inter locking paver block any shape and size ISI marked of 80mm thickness M-40 Grade, glossy finished of approved colour laid over and including 50 mm thick fine sand cushion to a line and slope etc. and joined complete including spreading screened river sand over surface for filling the joints with rising surface vibrator etc complete all as specified and directed.
M&L 75 mm thick PCC 1:3:6, type C-2 (using 40 mm graded stone agg) as in plinth protection /Path finishing cement concrete even and smooth without using extra cement including forming necessary joints 12mm wide to full depth of PCC at every 3 mtr and every change of direction and filling the same with bitumen filler 1:3 by weight complete all as specified and directed.
M&L 40mm thick PCC 1:2:4 type B1 (using 20mm graded stone agg) as in floor laid in panel finished even & smooth with using extra cement as in flooring complete all as specified and as directed.
Supply only glass dividing strip 3mm thick and 38mm wide in flooring complete all as specified and directed.
Demolition of reinforced cement concrete in roofs, floors (other than ground floors) beams, staircases, landing, chajjas and similar suspended work complete all as specified and as directed.
M&L RCC M-25 (using 20 mm graded stone aggregate) as in roof for maintain the uniform slope etc. as directed complete all as specified and as directed.
M&L for preparation of roof surface applying a coat of hot bituminous primer @ 0.30 kg/sqm and applying a coat of industrial bitumen 85/25 @ 1.20 kg/sqm over primer and laying modified polymeric water proofing membrane(weight not less than 4 kg/sqm, 3mm thick consisting 100 mm micron HMHDE FILM ) and applying one coat of industrial btumen grade 85/25 @ 1.2 kg/sqm on top of membrane with 100 mm overlap at side end lap where required and two coat of aluminium paint over top of the treatment as per manufacturer instruction and complete all as specified and directed
Demolition of cement concrete (un reinforced) of any description and in any position not other specifically provided for all as specified and direcetd.
M&L for preparation of sunken floor and applying a coat of hot bituminous primer @ .30 kg/sqm and applying a coat of industrial bitumen 85/25 @ 1.20 kg/sqm over primer and laying modified polymeric water proofing membrane(weight not less than 4 kg/sqm 3 mm thick consisting 100 mm micron HMHDE FILM ) and applying one coat of industrial btumen grade 85/25 @ 1.2 kg/sqm on top of membrane with 100 mm overlap at side end lap where required over and including 10 mm thick rendering in CM 1:4 mixed with integral water proofing compound @ 3% by weight of cement or as per manufactuerer's instruction and taking down existing plastering complete all as specified and directed
M&L for cement concrete (1:5:10) type E-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete all as specified and directed.
M&L PCC 25mm thick 1:2:4 of type B0 (using 12.5mm graded stone aggregate) as in base of floors and rough finish surface to receive the top layer of floor complete all as specified and directed.
S& in replacement vitreous china squatting pan "Orissa" pattern size 580mmx 440mm white with integral foot rests excluding flushing cistern and flush pipe all as specified and directed.
S&F in replacement vitreous china wash down water closet pan (pedestal pattern) white(excluding flushing cistern and flush pipe) including connection to drain or out going pipe and flush pipe anti symphonize pipe etc complete all as specified and as directed.
S&F in replacement plastic water closet seat cover black closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device all as specified and directed.
S & F in replacement 10 ltrs capasity PVC valveless syphonic action type flushing cistern low level white, with inlet ball valve, float and handle including bracket and flush pipe of polyethylene of low or high density or PVC 32 mm dia for low level cistern complete all as specified and as directed.
S&F in replacement vitreous china wash basin white, flat, back, size 550x400 mm excluding tap waste but including brackets and including cutting for and pinioning in ends of brackets but exclusive of supply waste pipe complete all as specified and directed.
S&F in replacement only 32mm dia waste fittings brass chromium plated for basin with long screwed shank and fly nuts, flange end bedded in red lead cement and other end fixed.complete all as specified and directed.
S&F in replacement15mm bore pillar tap cast copper allloy with capstan head Chromium plated screwed down with or without letter Hot or Cold with long shank and fly nuts screwed for iron pipe and fixed as specified and directed.
S&F in replacement bib taps 15mm bore chromium plated with crutch or butter fly handle screwed down for iron pipe or brass ferrule and fixed complete all as specified and direcetd.
S&F in replacement 15mm bore stop valve cast copper alloy chromium plated fancy type with long shank and cup ( concealed type)high pressure screwed for iron pipe and fixed all as specified.
S&F in replacement angle cock cast copper alloy chromium plated fancy type with crutch or butterfly handle screw down, screwed both end for iron pipe or brass ferrule for 15 mm bore of pipe complete all as specified and as directed.
S&F in replacement Vitreous China Urinal, Half Stall type(back or corner wall type) complete including providing and fixing plugs,bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws pointing around urinal back in cement fixing automatic flushing cistern with brakctes flush pipe grating and union for discharge pipe complete all as specified and directed.
S&F 600mmx 450mm bevelled edges mirror consisting of 5.5mm thick commercial plywood and fixed to plug with chromium plated brass screwed and cup washer complete all as specified and direceted.
S&F PVC connection 15mm bore length not less than 450 mm long with both ends PTMT nuts complete all as specified and directed.
S&F 75 mm dia PVC (SWR) floor trap plain with greting including jointing with solvent cement complete all as specified and direceted.
S&F in replacement swivel shower rose of brass Chromium plated for fixing with 15mm pipe fixed complete all as specified and directed.
Dismantling of existing water tank S&F rotational moulded polethylene water tank of 1000 ltrs capacity three layered ( cylindrical vertical with closed top) hoisted and fixed in position all as pacific SSR Part- I complete all as specified and directed.
S&F 20 mm bore gun metal ,globe or gate valves, with iron wheel head , screwed both ends for iron pipe all as specified and directed.
S&F 20 mm bore Ball valves ,high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule all as specified and directed.
Taking up or down existing steel tubing and connections including cleaning for refixing complete all as specified and directed for 15mm bore all as specified and directed.
Taking up or down existing steel tubing and connections including cleaning for refixing complete all as specified and directed for 20mm bore all as specified and directed.
S&F 15mm bore GI water tubing medium grade galvanised with and including all fittings and fixed complete to walls and ceilling or laid in floor all as specified and directed.
S&F 20mm bore GI water tubing medium grade galvanised with and including all fittings and fixed complete to walls and ceilling or laid in floor all as specified and directed.
Refixing 15mm bore old steel water tubing and connection in new or old position (walls, ceilling, floor etc) with and including new fittings complete all as specified and directed.
Refixing 20mm bore old steel water tubing and connection in new or old position (walls, ceilling, floor etc) with and including new fittings complete all as specified and directed.
Taking up or down existing pipe any class, any type, any dia (including all fitting) including disconnecting pipes and fittings complete all as specified and directed.
S&F 75 mm bore PVC (SWR) pipes of single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S&F 75 mm bore PVC (SWR) pipes of single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed.
S&F 75 mm bore. PVC (SWR) bends complete all as specified and directed.
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches complete all as specified and directed.
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed.
S&F 110 mm PVC (SWR) bend any radius complete all as specified and directed.
S&F 110mm bore.PVC(SWR) junction single (single T) equal or unequal with access door complete all as specified and directed.
S&F 75 mm dia stack clamps out of 50mmx5mm flat iron and 16mm dia round iron stays including bolts and nuts and securing ends of stays to ball or roof all as specified and directed.
S&F Stack clamps out of 50 x 5 mm flat iron and 16 mm dia round iron stays for 100mm bore pipes, including bolts and nuts and securing ends of stays to walls or roof all as specified and directed.
Demolition of brick work in cement mortar including all quoins, arches, pillars etc, but excluding ashler facings, dressed stonework and precast concrete articles etc complete all as specified and directed.
M&L Brick work with fly ash bricks (old size) as per IS 12894 -2002 straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, complete all as specified and directed.
S&Fin replacement aluminium hat pegs,solid body,125mm to 175mm complete all as specified and directed
M&L Brick work with fly ash bricks (old size) as per IS 12894 -2002 straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 as in half brick thick wall complete all as specified and as directed.
Taking down carefully, old unserviceable aluminium point wiring (light, fan, socket, bell, buzzer or power) complete including unserviceable fittings such as switch, socket, ceiling rose, lamp holder, light fittings, bakelite sheet, terminal box, etc. and making good to disturbed surfaces of wall/floor and ceiling etc. and removal, complete all as specified and as directed.( Note:- Existing LED bulbs/fittings are not to be removed and rates are inclusive of taking down & refixing of existing LED fitting at any location as directed by Engr-In-Charge. Disturbed surfaces shall be made good to match the existing surface finishes.
Taking down carefully by unscrewing from DB box MCB SP/SPN/TPN of sizes & any capacity complete all as specified and directed.
Taking down carefully by sub main wiring of any size complete all as specified and directed.
Point wiring in concealed PVC conduit using stranded copper conductor cable of size 1.5 Sqmm, PVC insulated unsheathed FRLSH cable complete with all fittings and accessories but using existing sunken cast iron or pressed steel terminal box for mounting of switches, sockets, fan regulators etc but providing new cover 3mm thick laminated,(Hylem) sheet top cover fastened with chromium plated screws and 1.5 Sqmm PVC insulated stranded copper conductor FRLSH cable as continues earth wire connected to common earth dolly all as directed and as specified for the following :- NOTE: for wiring in ceiling portion conduit shall be fixed with surface of ceiling/with trusses etc. (a). One light/fan point controlled by one switch
(b). One 3-pin socket outlet 5 Amp on independent board.
(c). One 3 pin socket outlet 5 Amp on same board.
All per Srl item No. 100 here-in-before, but with 2.5 Sqmm copper conductor cable complete all as specified for One 3 pin socket outlet 15 Amp on independent board.
M&L for two single core PVC Insulated unsheathed multi stranded FRLSH copper conductor cable of size 6sqmm as sub main wiring including suitable size heavy duty rigid PVC conduit and of PVC insulated unsheathed multi stranded FRLSH copper conductor cable of size 6 sqmm as an earth continuity conductor complete all as specified and directed.
M&L for two single core PVC Insulated unsheathed multi stranded FRLSH copper conductor cable of size 10 sqmm as sub main wiring including suitable size heavy duty rigid PVC conduit and of PVC insulated unsheathed multi stranded FRLSH copper conductor cable of size10 sqmm as an earth continuity conductor complete all as specified.
S & F switch piano flush type polycarbonate SP one way 5 Amps complete all as specified and directed.
S &F switch piano flush type polycarbonate SP one way 15 Amps complete all as specified and directed.
S&F socket out let 3 pin 5 amp multipurpose flash type complete all as specified and directed.
S&F socket out let 3 pin 5/15 Amp multipurpose, flush type 240 volt complete all as specified and directed.
S&F ceiling rose surface Bakelite 65 x 50 mm two to three terminals complete all as specified and directed.
S&F for lamp holder insulated body of PVC / polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
M & L for replacement of Step regulator electronic fan regulator flush type on the existing phenolic laminated sheet etc as required complete & all as specified and directed.
S&F in replacement MCBs SP 6-32 Amps breaking capacity 10 KA 'B' series 240 volts 50 Hz complete all as specified and directed.
S&F inreplacement MCB SP&N 10 to 63 Amps breaking capacity 10 KA 'C' series 240 volts 50 Hz complete all as specified and directed.
S&F MCB DB Single pole and neutral 8 way sheet steel phospetised powder painted with 200 amps rated bus bar with IP 43 protection 240 V nautral link, earth bar and Din rail double door complete all as specified and as direcrted.
Taking down and refixing the same serviceable LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder includingLED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. with suitable size complete all as specified and as directed.
S&F in replacement LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder includingLED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. with suitable size all as specified and as directed.
S&F in replacement LED bldg security light fitting 35 Watt230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistantcomplete with driver, lamp bracket with impactand corrosion resistant including thermalmanagement in multiple optics complete withIP 65/66 protection complete. Connecting up with 3 core flexible copper cable of suitable size complete all as specified and directed..
M&L for earthing complete with galvanized steel earth plate electrode 60cm×60cm× 6mm thick, buried directly in ground, vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the earth plate at depth not less than 1.5 mtr below ground level earth plate surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, earth lead GI wire 4mm dia by means of bolts, nuts, check-nuts and washers of galvanized iron and thimbles and of earth wire protected by galvanized iron pipe light grade 15mm bore and water pipe 20 mm bore GI medium grade with funnel and wire mesh complete including excavation and earth work, PCC chamber and cover in cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate in lieu of CI cover and frame etc all as specified and shown in electrical plate No. 3 of SSR-2009 (Part-I) and directed..
S&F in replacement Sheet metal enclosure TPN distribution board vertical type double door with insulated bus bar arrangement IP 43 protection 4 way 415V complete all as specified .
Taking down and refixing the same after of building work and painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. and connecting to existing connection and testing complete all as specified and directed.
Taking down and refixing the same after repair of building work and painting of exhaust fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. and connecting to existing connection and testing complete all as specified and directed.
M&L for rewinding of burnt fan motor with super enameled copper wire of suitable size 1200/1400mm sweep ceiling fan of any make, type, model including transporation (inclusive of material & labour) complete all as specified and as directed
Taking up cable from trenches & poles and supply, laying & testing XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100V grade, cross-sectional area 25 sqmm 4 core complete all as specified and directed.
S&F in replacement MCCB 4 POLE 63 Amps 10 KA complete all as specified and directd.
Excavation in trenches n. exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying underground LT XLPE cable and getting soft/loose soil complete all as specified and directed.
Returning , filling in including spreading, leveling, watering and well ramming in laying not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated material (soils) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Material and labour for river fine sand, washed and screened dry for cushioning to underground cable in trenches below and around underground cable including spreading and leveling punning complete all as specified and directed.
M&L for laying fly ash bricks (old size) as per IS 12894 -2002 for protection of cable, in trenches, laid in dry flat across the cable with length of whole bricks complete all as specified and directed.
M/S DEEN ENTERPRISES
M/S Gupta Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .