| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance B 30 JEEVAN VIHAR SHASTRI NAGAR GHAZIABAD UTTAR PRADESH 201001 | GHAZIABAD | UTTAR PRADESH | 201001 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹10.7 L
EMD Value
₹21,500
Closing Date
16 Oct 2021, 2:00 pmClosed
Sr. S.E. and Head WS
NPL Campus New Delhi
Vitrified tile flooring, aluminium work, false ceiling, painting, electrical work, etc.
2021_CSIR_90811_1
04/0205/20 WS
Open Tender
Civil Works
Item Rate
75 days
NPL Campus New Delhi
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Director NPL
₹21,500
8 Nov 2021
7 Oct 2021
18 Oct 2021
7 Oct 2021
16 Oct 2021
7 Oct 2021
Amount
(A) Civil work Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.
Dismantling/ removing old PVC flooring in sheet or tiles and cleaning the surface by to removing adhesive including stacking of serviceable material and disposal of unserviceable rubbish maaterial to outside NPL campus, including hacking of floor before fixing of tile.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots (Heavy weight SS hinges 125x64x2.5mm in case of door shutters and 100x60x2.5mm in case of window shutters) and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Providing and fixing chrome finished 250 mm mortice latch & lock complete pack (Rose) of Harrison AURA/ CORAL (Code 43562) for door shutters with necessary CP brass/SS screws. (Preferred make Godrej/ Dorma/ Hardwyn/ Harrison).
Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 125 mm
Providing and fixing stainless steel tower bolt 250mm, with rod size 10 mm square knob with necessary SS/CP brass screws. (Preferred make Godrej/ Harrison/ Hardwyn/ Dorma).
Providing and fixing stainless steel tower bolt 150mm, with rod size 10 mm square knob with necessary SS/CP brass screws. (Preferred make Godrej/ Harrison/ Hardwyn/ Dorma).
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Providing and applying white cement based putty of average thickness 1 mm (to be applied in two coats), of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats
Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). (Double charged vitrified tiles to be used) Size of Tile 600x600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). (Double charged vitrified tiles to be used) Size of Tile 600x600 mm
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying
15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK.
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1cement: 4 coarse sand)
Providing and fixing 100mm verticle blind, Vista dust guard or equivalent of make Nova/Mac. Actual fix area shall be mesuared from top of channel to bottom of blinds.
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Deduct for disposal/taking out of old dismantled scrap of mild steel like angle, tee, flat, doors/ windows sections, etc. from the location where it has been dismantled.
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources: 6 graded stone aggregate 20 mm nominal size derived from natural sources).
1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
Providing and laying 110mm dia, unplasticised rigid PVC pipe (4kg/sq c.m.) confirming to IS: 13592, Type A, including jointing with adhesive.
(B) Electrical work Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C
Supply, Installation, testing and commissioning of recessed/surface mounting LED flat panel 2`X2`, 36 watt with high efficient LEDs and glare free opal diffuser equavalent to cat No. HLFPR22-02-36-CW/HLFPS22-02-36-CW of Halonix make complete with all respect including hanging/fixing arrangement. Make should be Phillips/Crompton greaves/ Halonix oe equavalent. (The contractor shall provide minimum Three year warrantee for LED light fittings from manufacturers.)
Supply of 1200 mm sweep, 230 V, AC, 50 Hz, energy efficient five star rating, ceiling fan complete in all respect including blades, capacitor, standard down road upto 30 cm long etc as required. Fan should be Havells/ crompton greaves or equivalent. All fan should be 5 star rated energy efficient of respective models.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. Regulator should be North West/ Crabtree/ schiender/ panasonic vision or equavalent.
Installation,testing and commissioning of ceiling fan including wiring the down rods of standard length ( up to 30 cm) with 1.5sq.mm. FRLS PVC insulated, copper conductor,single core cable as required.
Supply and fixing of MS plate 4 mm thick, 100x100 mm with fixing on roof by 4 nos fastners including providing and welding ceiling fan hook on MS plate as required as per site condition.
Supplying and fixing extra down rod of 10 cm length G.I. pipe,15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
1 or 2 Module (75mmX75mm)
3 Module (75mmX75mm)
12 Module (200mmX150mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. All the switches, socket etc. should be modular screw type equavalent to North West Make should be North West/ Crabtree/ schiender/ panasonic vision or equavalent.
15/16 amp switch
6 pin 15/16 amp socket outlet
Telephone socket outlet
Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and drawing 2 pair 0.5 sq mm FR PVC insulated copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. ( All the wires/cables should be multistrand, ISI marked, Kalinga/Fenolex/ KEI/Polycab/ Havells make)
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
Supplying and fixing AC box 3 way modular including 20A Single pole 240 volts “C” curve DP MCB, 15 Amp socket, 3 module GI box complete with all respect, connections, testing and commissioning etc. as required. AC box should be equavalent to anchor 98488 AC box 3-way modular UNO 20A SP, White of anchor make.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (All the MCB's MCCB, MCB DB, should be Legrand/ L&T/ schneider make or equavalent.) 6 way, Double door SPN DB
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) (All the MCB's MCCB, MCB DB, should be Legrand/ L&T/ schneider make or equavalent.) 4 way (4 + 12), Double door
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (All the MCB's MCCB, MCB DB, should be Legrand/ L&T/ schneider make only.) 100 A, 16 kA,TPMCCB
Supplying and fixing of following rating, 240 /415 volts, C series, miniature circuit breaker of following poles in the existing MCB DB/ MCCB in existing cubical panel board including drilling holes in cubical panel making complete with connections, testing and commissioning as required. (All the MCB's MCCB, MCB DB, should be Legrand/ L&T/ schneider make only.)
5 to 32 amp. SP MCB
5 to 32 amp. SPN MCB
Supplying and fixing of 25 mm steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall/making hole in the wall and making good the same in case of recessed conduit as required. 25 mm.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. (Cable should be D -Link / Digi link make only) (cable should be marrked by ferrule at both ends)
Drawing of UTP 4 pair CAT 6 LAN Cable/telephone wire in the existing surface/ recessed steel/ PVC conduit as required. (Cable should be D -Link / Digi link make only) (cable should be marrked by ferrule at both ends)
Supply and fixing one no. wall mounting CAT 6 I/O connection box punch type internet socket with shutter on existing modular box complete in all respect excluding connections as required. (I/O box should be D -Link, Molex,AMP-Netconnect, Panduit make only (connection will be done by department)
Supply of 4 X 35 sq. mm XLPE insulated, PVC sheathed , aluminum conductor armoured cable of 1.1 KV grade as required.
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 35 sq. mm (38mm)
Dismentalling and disconnection of old DB's DB's / small panels, switch board, tube, light fitting, fan, cable, wiring, conduit, etc as required as following.
TL fitting, switch socket board, Db'/small panels etc.
Wiring , cable and Conduit etc.
sahil builders and construction
Y.K. Sharma
B S ELECTRICALS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .