Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.5 LAccepted-Finance | L1 | Accepted-Finance Being lowest | |
| 2 | L2₹39.8 L+₹10.3 L (34.9%)Accepted-Finance | L2 | Accepted-Finance Not lowest | |
| 3 | L3₹46.5 L+₹17.1 L (57.9%)Accepted-Finance | L3 | Accepted-Finance Not lowest | |
| 4 | Rejected-Technical | - | Rejected-Technical Bid rejected due to firm not having b(i) category |
| Sl No | Description | Qty | Unit | M/s S.G. BUILDERS L1 | yameen enterprises L3 | Pall Associates L2 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down ceiling fan / exhaust fan/ fresh air/ Wall mounted fan including refixing the same after necessary repairs/ replacement of unserviceable/ wornout part and testing as per entire satisfaction of Engr-in- Charge complete all as specified and directed.
Note : Spare parts shall be measured and paid seperately under relevent of supply only. | 960 | Each | 10 ₹9,600 Lowest | 100 ₹96,000 | 20 ₹19,200 |
| 2.00 | Taking out unsv winding of ceiling fan and M&L for rewinding of ceiling fan 1200 mm 1400 mm sweep any make and type with super enamelled copper winding wire,wraping insulating material, insertion and varnishing well including drying complete and testing of the ceiling fan after refixing in position to the entire satisfaction of Engr-in-Charge. | 800 | Each | 250 ₹2,00,000 Lowest | 350 ₹2,80,000 | 250 ₹2,00,000 Lowest |
| 3.00 | S&F in replacement Ceiling fan blade suitable for 1200mm /1400 mm sweep of any make with suitable size as per site requirement complete all as specified and directed by Edngineer-in-Charge. (As per sample) | 800 | Set of 3 | 110 ₹88,000 | 150 ₹1,20,000 | 100 ₹80,000 Lowest |
| 4.00 | S&F PVC canopy upper and lower of celing fan of any make & size complete with nuts, bolts & washers complete all as specified and directed by Edngineer-in-Charge. | 800 | Each Set | 16 ₹12,800 Lowest | 30 ₹24,000 | 40 ₹32,000 |
| 5.00 | Taking down old unserviceable down rod and supply and fix 1.5 mtr long down rod duly made out off Mild steel including taking down & refixing of existing ceiling fan of any sweep and make and making connection from ceiling rose to PVC connector complete all as specified and directed by Engineer-in-Charge. | 100 | Each | 99 ₹9,900 | 120 ₹12,000 | 70 ₹7,000 Lowest |
| 6.00 | S&F in replacement ceiling fan down rod 0.6 mtr long duly made out off mild steel including rubber bush nut, bolt, washer and split pin complete all as specified and directed by Engineer-in-Charge. | 800 | Each | 28 ₹22,400 Lowest | 80 ₹64,000 | 70 ₹56,000 |
| 7.00 | S&F in replacement capacitor of 1.0 MFD complete all as specified and directed by Engineer-in-Charge. | 100 | Each | 23 ₹2,300 | 35 ₹3,500 | 20 ₹2,000 Lowest |
| 8.00 | S&F in replacement capacitor 3.15 MFD complete all as specified and directed by Engineer-in-Charge. | 1,150 | Each | 27 ₹31,050 Lowest | 45 ₹51,750 | 50 ₹57,500 |
| 9.00 | S&F in replacement capacitor 4.0 MFD complete all as specified and directed by Engineer-in-Charge. | 300 | Each | 30 ₹9,000 Lowest | 50 ₹15,000 | 75 ₹22,500 |
| 10.00 | S&F in replacement only ball bearing No. 6202 complete all as specified and directed by Engineer-in-Charge. | 800 | Each | 39 ₹31,200 Lowest | 40 ₹32,000 | 75 ₹60,000 |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
4 Dec 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MAJ MANISH E WASNIK
GE (CENTRAL) DELHI CANTT-10
GE/Token-60/2025-26
2025_MES_738553_1
GE/TOKEN-60/2025-26
Open Tender
Civil Works
Item Rate
270 days
GE (CENTRAL) DELHI CANTT-10
AS PER NIT
9 documents required · 9 mandatory
₹500
Yes
GE (CENTRAL) DELHI CANTT-10
₹1 L
Yes
24 Dec 2025
6 Nov 2025
6 Dec 2025
6 Nov 2025
4 Dec 2025
20 Nov 2025
Amount
Taking down ceiling fan / exhaust fan/ fresh air/ Wall mounted fan including refixing the same after necessary repairs/ replacement of unserviceable/ wornout part and testing as per entire satisfaction of Engr-in- Charge complete all as specified and directed. Note : Spare parts shall be measured and paid seperately under relevent of supply only.
Taking out unsv winding of ceiling fan and M&L for rewinding of ceiling fan 1200 mm 1400 mm sweep any make and type with super enamelled copper winding wire,wraping insulating material, insertion and varnishing well including drying complete and testing of the ceiling fan after refixing in position to the entire satisfaction of Engr-in-Charge.
S&F in replacement Ceiling fan blade suitable for 1200mm /1400 mm sweep of any make with suitable size as per site requirement complete all as specified and directed by Edngineer-in-Charge. (As per sample)
S&F PVC canopy upper and lower of celing fan of any make & size complete with nuts, bolts & washers complete all as specified and directed by Edngineer-in-Charge.
Taking down old unserviceable down rod and supply and fix 1.5 mtr long down rod duly made out off Mild steel including taking down & refixing of existing ceiling fan of any sweep and make and making connection from ceiling rose to PVC connector complete all as specified and directed by Engineer-in-Charge.
S&F in replacement ceiling fan down rod 0.6 mtr long duly made out off mild steel including rubber bush nut, bolt, washer and split pin complete all as specified and directed by Engineer-in-Charge.
S&F in replacement capacitor of 1.0 MFD complete all as specified and directed by Engineer-in-Charge.
S&F in replacement capacitor 3.15 MFD complete all as specified and directed by Engineer-in-Charge.
S&F in replacement capacitor 4.0 MFD complete all as specified and directed by Engineer-in-Charge.
S&F in replacement only ball bearing No. 6202 complete all as specified and directed by Engineer-in-Charge.
S&F in replacement only ball bearing No. 6203 complete all as specified and directed by Engineer-in-Charge.
Taking out old unserviceable ceiling fan rotor and fixing the new rotor on ceiling fan of any sweep and make and making in good condition complete all as specified and directed by Engineer-in-Charge.
Taking out old unserviceable ceiling fan stator and fixing the new stator on ceiling fan of any sweep and make and making in good condition complete all as specified and directed by Engineer-in-Charge.
Taking out old unsv worn out shaft of existing ceiling fan any make, type or size and repair/replacement of same as per existing ceiling fan complete all as specified and directed by Engineer-in-Charge.
Taking out old unsv gun metal bush of any size and repair/replacement of same as sutiable for ceiling fans 1200/1400 mm complete all as specified and directed by Engineer-in-Charge.
S&F in replacement only ceiling fan housing body parts complete all as specified and directed by Engineer-in-Charge.
S&F in replacement only spring of ceiling fan complete all as specified and directed by Engineer-in-Charge.
S&F in replacement only motor screw of ceiling fan complete all as specified and directed by Engineer-in-Charge.
S&F in replacement only rubber clamp of ceiling fan with nuts, bolts & washers and safety pin complete all as specified and directed by Engineer-in-Charge.
S&F in replacement only capacitor clamp of ceiling fan complete all as specified and directed by Engineer-in-Charge.
S&F in replacement only blade screw of ceiling fan complete all as specified and directed by Engineer-in-Charge.
M & L for painting of ceiling fans , in situ with synthetic enamel paint by spraying including filling cavities with filler, one or more coat to achieve even and smooth surface after cleaning all dust etc. paint complete all as specified and directed by Engineer-in-Charge.
Taking out unsv winding of exhaust fan and M&L for rewinding of Exhaust fan 225/300 mm sweep any make and type with super enamelled copper winding wire,wraping insulating material, insertion and varnishing well including drying complete and testing of the exhaust fan after refixing in position to the entire satisfaction of Engr-in-Charge.
Taking out unsv winding of exhaust fan and M&L for rewinding of Exhaust fan 450 mm sweep any make and type with super enamelled copper winding wire,wraping insulating material, insertion and varnishing well including drying complete and testing of the exhaust fan after refixing in position to the entire satisfaction of Engr-in-Charge.
S&F in replacement exhaust fan Metal blade suitable for 225/300mm sweep of any make with suitable size of split pin as per site requirement complete all as specified and directed by Edngineer-in-Charge.(As per sample)
S&F in replacement exhaust fan Metal blade suitable for 450 mm sweep of any make with suitable size of split pin as per site requirement complete all as specified and directed by Edngineer-in-Charge.(As per sample)
Taking out old unserviceable Exhaust fan stator and fixing the new stator on Exhaust fan of any sweep and make and making in good condition complete all as specified and directed by Engineer-in-Charge.
Taking out old unserviceable Exhaust fan rotor and fixing the new rotor on Exhaust fan of any sweep and make and making in good condition complete all as specified and directed by Engineer-in-Charge.
Taking out old unsv worn out shaft of existing Exhaust fan any make, type or size and repair/replacement of same as per existing exhaust fan complete all as specified and directed by Engineer-in-Charge.
Taking out old unsv gun metal bush of any size and repair/replacement of same as sutiable for Exhaust fans complete all as specified and directed by Engineer-in-Charge.
S&F in replacement only ball bearing of exhaust fan complete all as specified and directed by Engineer-in-Charge.
S&F in replacement only motor screw of Exhaust fan complete all as specified and directed by Engineer-in-Charge.
S&F in replacement only Exhaust fan motor housing body parts of any make and size complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of body frame for holding exhaust fan motor and grill parts of any make and size complete all as specified and directed by Engineer-in-Charge.
S&F in replacement only Exhaust fan grill of existing of any make and size complete all as specified and directed by Engineer-in-Charge.
S&F in replacement only rubber pad for suspenion of Exhaust fan complete all as specified and directed by Engineer-in-Charge.
M & L for painting of exhaust fans complete, in situ with synthetic enemel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed by Engineer-in-Charge.
S&F in replacement PVC cable copper conductor multi strandrad flexible 23/.0076 twin core and making connections from ceiling rose to fan complete all as specified and directed by Engineer-in-Charge.
Taking out unsv motor and repair/replacement of Fresh air fan motor of suitable capacity as required on site 230 volts, 50 Hz, AC supply suitable for 300/250/200 mm size Fresh air fan as per sample complete all as specified and directed by Engineer-in-Charge.
Taking out old unsv front cover frame body part of existing ventilation fan any make, type or size and repair/replacement of same as per existing ventilation fan complete all as specified and directed by Engineer-in-Charge.
Taking out old unsv motor holding frame body part of existing ventilation fan any make, type or size and repair/replacement of same as per existing ventilation fan complete all as specified and directed by Engineer-in-Charge.
Taking out old unsv PVC louver/shutter frame of existing ventiation fan any make, type or size and repair/replacement of same as per existing ventilation fan complete all as specified and directed by Engineer-in-Charge.
Taking out old unsv PVC blade of existing ventilation fan any make, type or size and repair/replacement of same as per existing ventilation fan complete all as specified and directed by Engineer-in-Charge.
Taking out old unsv winding of wall fan 400 mm sweep any make and type and rewinding with super enamelled copper winding wire,wraping insulating material, insertion and varnishing well including drying complete and testing of the wll fan after refixing in position to the entire satisfaction of Engr-in-Charge.
Taking out old unsv pvc blade of wall fan and S&F in replacement of pvc blade of wall fan suitable for 400mm sweep of any make with suitable size of split pin as per site requirement complete all as specified and directed by Edngineer-in-Charge.(As per sample)
Taking out old unserviceable wall fan stator and fixing the new stator on wall fan of any sweep and make and making in good condition complete all as specified and directed by Engineer-in-Charge.
Taking out old unserviceable wall fan rotor and fixing the new rotor on wall fan of any sweep and make and making in good condition complete all as specified and directed by Engineer-in-Charge.
Taking out old unsv worn out shaft of existing wall fan any make, type or size and repair/replacement of same as per existing wall fan complete all as specified and directed by Engineer-in-Charge.
Taking out old unsv gun metal bush of any size and repair/replacement of same as sutiable for wall fans 400 mm sweep complete all as specified and directed by Engineer-in-Charge.
S&F in replacement only ball bearing of wall fan motor complete all as specified and directed by Engineer-in-Charge.
S&F in replacement only motor screw of wall fan complete all as specified and directed by Engineer-in-Charge.
S&F in replacement only wall fan motor housing body parts of any make and size complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of rear grill with motor holding frame of wall fan of any make and size complete all as specified and directed by Engineer-in-Charge.
S&F in replacement front grill of existing wall fan of any make and size complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Rotary knob of wall fan complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Pull cord (speed control) of wall fan complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Plastic Nut for fixing rear grill of wall fan complete all as specified and directed by Engineer-in-Charge.
S&F in replacement 12'' fan Spinner for fixing/holding fan blade of wall fan complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Ornament in front of grill of wall fan complete all as specified and directed by Engineer-in-Charge.
S&F in replacement mounting plate with screw for holding of wall fan in wall complete all as specified and directed by Engineer-in-Charge.
M & L for painting of wall fans Grill complete, in situ with synthetic enemel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed by Engineer-in-Charge.
S&F in replacement non return valve 15mm dia (ISI Marked) for Geysers of 50/35/25 Ltr capacity including GI Socket,Nipple, elbow ,bend etc and connecting up complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for fixing in replacement safety pressure valve (as per sample) for geysers complete all as directed by Engineer-in-charge.
S&F in replacement SS braided pipe of 12 mm (internal) suitable for hot/cold water, 600 mm long with brass nuts and rubber washers complete all as specified and directed by Engineer-in-Charge.
S&F in replacement heating element of 2/3 KW,(as per sample) with nut bolt washer complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of thermostat for 3/25/35/50 ltrs capacity of Instant/normal geysers complete all as specified and directed by Engineer-in-Charge.
S&F in replacement neon lamp/indicator lamp for geysers complete all as specified and directed by Engineer-in-Charge.
S&F in replacement plug top, 3 pin, 20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer-in-Charge.
S&F socket 3 pin 20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer-in-Charge.
S&F in replacement fastner 100mm long & 6mm dia long with suitable size of nut for fixing geyser/Exhaust Fan complete all as specified and directed by Engineer-in-Charge.
M&L for soldering and brazing inner copper tank 50/25/35 ltrs with brass solder and refixing complete (taking down and fixing shall be paid under item No 3 above) complete all as specified and directed by Engineer-in-Charge.
S&F in repair&replacement base plate assembly (confirming to ISI ) complete for 25/35 Ltrs capacity copper tank geyser including inlet, outlet and thermostat pipe with drain plug and screws for fixing the element inclusive of clamps for holding the elements with nut, bolts & air release valve suitable for any type/make of geysers installed at site complete all as specified and directed by Engineer-in-Charge.
S&F in repair&replacement inner Steel tank for geysers of capacity 25/35 ltr as per existing of approved make complete all as specified and directed by Engineer-in-Charge.
S&F inrepair& replacement outer body/cover suitable for 25 ltr cap geyser made out of mild steel pre-treated and stove enamelled sheet of 18 SWG complete with top and bottom cover, rubber gasket, stead screw for fixing the top and bottom cover to outer body including two coat of white synthetic enamel paint over one coat of red oxide (spray painting) complete all as specified and directed by Engineer-in-Charge.
S&F in repair&replacement top cover for geysers (confirming to IS) suitable for any makes/capacity/type of geysers installed at site duly painted (spray) in two coats with enameled (Deco) paint of colour & shade complete all as specified and directed by Engineer-in-Charge.
S&F in repair&replacement bottom cover for geysers (Confirming to IS) suitable for any make/capacity/type of geysers installed at site duly painted (spray) in two coats with enameled (Deco) paint of colour & shade as directed complete with inspection plate in two pieces.
S&F in replacement of electric panel hylem sheet size 12''x8'' with suitable size of screw for fixing complete all as specified and directed by Engineer-in-Charge.
Repair and replacement of Elecronic mother board / PCB of Existing BLDC ceiling fan of any make as per site requirment complete all as specified and directed by Engineer-in-Charge.
M&L for fixing of suitable size of fan hook/ clamp made mild steel 6 mm thick in round shape fixing in 40mm GI pipe, load carrying capacity not less than 6 kg and necessary accessories as per site requirement complete all as specified and directed.
Attending all types of complaints pertaining to unsv/non functional geysers of any type/capacity at site, inspection of faulty geyser including lowering down it for fault assessment and rectification of any electric fault/water leakage and other defects in all respects including replacement of unserviceable spares such as heating element,thermostat, indicator lamps,top and bottom plates, safety plug etc.,burnt copper wire, connections wherever required and repairing any type of switch, socket, plug top etc and fixing it to its original position after repair complete all as specified and directed. Notes for Item No. 80, 81 and 82:- (a) fixtures/fittings shall be paid under relevant item against Supply in replacement. (b) Contractors are advised to visit the sites before quoting their rates. (c) Materials for minor and maintenance repair works as directed by Engineer-in-Charge shall be supplied by the contractor within one week from the date of issue of work order. (e) Contractor shall provide and deploy adequate experienced professional to carry out day to day complaints and must deploy 01 electrician and 01 helper at Complaint cell from 0900Hrs to 1700 Hrs from Monday to Sunday. Electrician and helper shall report to complaint cell at 0900 hrs daily to receive job card from concern departmental person for carry out the work and same will be retrun to concered JE at 1700 hrs as token of completion of job. In case of any breakdown/ emergency, contractor shall make arrangement to attend and rectify the complaints in odd hours on sunday/holiday also and rates quoted in respective items of sch 'A' shall deemed to be included in unit rate quoted by the contractor and no extra cost shall be paid for the same. Note: whatever will be the nature of electrical complaint, responsibilty of rectification in all respect shall be lies with the contractor. (f) Penalty @ Rs.100/- per complaint per day shall be imposed if contractor fails to attend the complaint within one hours after receiving the complaint of any nature. (g) Contractor shall provide printed complaint books serially numberd for entire duration of the contract agreement.Sample of the complaint slip shall be provided by the department and amount of printed docket/complaint slip shall be deemd included in the unit rate quoted by the contractor. Note: Item No 62 to 66, 117,127 to 129 will be covered under this item.
Checking electrical points for continuous electric supply to circuit/system and replacement of unserviceable spares for all electrical fixtures, ceiling/exhaust fans of any size and capacity and carrying out minor repairs, fixing screws, tightening of loose wires, any type renewal of small pieces of electric wire upto 1.00 mtr length and maintenance work complete on all working days including holidays at GE (Central) and adjoining area all as directed by Engr-in-charge.Note: Item No 90,97, 125, 126 and 134 will be covered under this item.
Attending to complaint of unsv switch ,socket ,fan regulator and making of light / power point in casing caping upto 2 mtr of length and maintenance work complete on all working days including holidays at GE (Central) and adjoining area all as directed by Engr-in-charge.Note: Item No 84 to 89, 91 to 116, 118 to 124, 130 to 134 will be covered under this item.
Attending electrical complaint of No light/short circuit in light point/socket/power circuit/AC circuit/or any other electrical circuit of house including tripping in MCB/MCCB or any other emergency nature complaint during night hours (from 09 pm to 05 am) and replacement of fitting/fixtures/MCB/MCCB etc if required, during night hours and restored electric supply upto entire satisfaction of concerned user of occupied house/bldg. Notes for Item No. 83:- (a) fixtures/fittings shall be paid under relevant item against Supply in replacement only. (b) Contractors are advised to visit the sites before quoting their rates. (c) Materials for minor and maintenance repair works as directed by Engineer-in-Charge shall be supplied by the contractor within one week from the date of issue of work order. (e) Contractor shall provide and deploy adequate experienced professional to carry out day to day complaints and must deploy 01 electrician at Complaint cell from 2100 Hrs to 0500 Hrs from Monday to Sunday. Electrician shall report to complaint cell at 2100 hrs daily. In case of any breakdown/ emergency, contractor shall make arrangement to attend and rectify the complaints in odd hours on sunday/holiday also and rates quoted in respective items of sch 'A' shall deemed to be included in unit rate quoted by the contractor and no extra cost shall be paid for the same. Note: whatever will be the nature of electrical complaint, responsibilty of rectification in all respect shall be lies with the contractor. (f) Penalty @ Rs.100/- per complaint per day shall be imposed if contractor fails to attend the complaint within one hours after receiving the complaint of any nature. (g) Daily attendance register will be maintained by converned JE and if any electrician/ helper found absent on any working day then penalty @Rs 1000/- per day per workman will be recoverd from the contractor. (h) Contractor shall submit all necessary documents of all electrician and helpers as desired by the the department and also shall be bound to follow all instructions passed time to time by concerned unit/area head.
Supply in replacement switch piano flush button type single pole one way 6 Amps all as specified.
Supply in replacement switch piano 6 amp SP two way, ISI marked.
Supply in replacement socket piano outlet 6 Amp flush button type all as specified.
Supply in replacement bell push single pole 6 Amps all as specified.
Supply in replacement switch piano flush button type single pole 16 Amps.
Supply in replacement socket piano outlet, 2 in 1, 3 pin 6 and 16 Amp single pole .
Supply in replacement Ceiling fan regulator electronic step switch type/socket type, suitable for 1200/1400 mm sweep ceiling fan, 230 Volts single phase complete.
Supply in replacement switch Modular type 6 Amps one way 230V AC complete all as specified and directed by Engineer in charge.
Supply in replacement switch Modular type 6 Amps two way 230V AC complete all as specified and directed by Engineer in charge.
Supply in replacement replacement Modular Bell push button SP with indicator 6 Amps, 1 module 230V AC complete all as specified and directed by Engineer in charge.
Supply in replacement Modular socket outlet 5 pin 6 Amp socket 2 moduler complete all as specified and directed by Engineer in charge.
Supply in replacement switch Modular type 16 Amps one way 230V AC complete all as specified and directed by Engineer in charge.
Supply in replacement Modular socket outlet 5 pin 6/16 Amp universal socket 2 module complete all as specified and directed by Engineer in charge.
Supply in replacement Modular five stepped type electronic fan regulator 1/2 module 230V AC complete all as specified and directed by Engineer in charge.
Supply in replacement ceiling rose surface PVC type with three terminals.
Supply in replacement Electric bell Ding-Dong AC 230 Volt etc complete all as specified and directed.
Supply in replacement insulated body, angle holder (metal ring) with back plate ISI marked complete all as directed.
Supply in replacement industrial metal clad plug top, 3 pin, 10amp / 20 amp (ISI marked) as directed.
Supply in replacement industrial metal clad socket 3 pin 10 amp / 20 amp (ISI marked) as directed.
Supply in replacement relacement plug top 16 Amps 3 pin 230- volts.
Supply in replacement LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts, > 2400 systems lumen output with lifetime of 25000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 Degree system efficiancy at luminarie level ≥120 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
Supply in replacement LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with lifetime of 25000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed.
Supply only LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 100 lm/W with a life class of 25,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
Supply in replacement surface ceiling mounted, round LED down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 100 Lumens/watt, 25000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
Supply in replacement in replacement of decorative type wall mounted luminaire (Comet) with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base.
Supply in replacement 14W LED Bulbs, high energy efficiency LED luminaries to be fitted on existing holders 240 V,50 Hz complete all as directed by Engr-in-Charge.
Supply in replacement 9 W LED Bulbs, high energy efficiency LED luminaries to be fitted on existing holders 240 V,50 Hz complete all as directed by Engr-in-Charge.
Supply in replacement MCB SPN 40 Amps 240 volts,10 KA 50 HZ 'B' curve and making necessary electrical connection complete all as directed by Engr-in-Charge.
Supply in replacement MCB DP 20 Amps 240 volts 10 KA 50 HZ 'B' curve and making necessary electrical connection complete all as directed by Engr-in-Charge.
Supply in replacement MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve and making necessary electrical connection complete all as directed by Engr-in-Charge.
Supply in replacement MCB DP 63 Amps 240 volts 10 KA 50 HZ 'C' curve and making necessary electrical connection complete all as directed by Engr-in-Charge.
Supply in replacement MCCB 160 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting and making necessary electrical connection complete all as directed by Engr-in-Charge.
Supply in replacement MCCB 125 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting and making necessary electrical connection complete all as directed by Engr-in-Charge.
Supply in replacement single pole and neutral enclosure with a two pin earth plug and socket complete with one single pole MCB SP 20 Amp and making necessary electrical connection complete all as directed by Engr-in-Charge.
Supply in replacement PVC Gang box surface type heavy duty suitable for single switch 5 Amps (ISI Marked) .
Supply in replacement Gang box surface type heavy duty suitasble for 15 Amps switch and socket (ISI Marked)
Supply in replacement/replacement white cover plate with frame 1 module/ 2 module complete all as specified and directed by Engineer in charge.
Supply in replacement/replacement white cover plate with frame 3 module complete all as specified and directed by Engineer in charge.
Supply in replacement/replacement white cover plate with frame 6 module complete all as specified and directed by Engineer in charge.
Supply in replacement/replacement white cover plate with frame 8 module complete all as specified and directed by Engineer in charge.
Supply in replacement hylum sheets 3 mm thick (ISI marked) of the following sizes.
T Cover
Sheet 4" x 4" two cuttings suitable for two piano switches
Sheet 4" x 7" three cuttings suitable for three piano switches
Sheet 4" x 7" one cutting for 6 Amp socket and two cuttings for piano switches
Sheet 8" x 10" incl cuttings for switches and sockets 6/16Amps as directed.
Sheet 10" x 12" incl cuttings for switches and sockets 6/16Amps as directed.
Supply in replacement replacement of capacitor 1.5 Mfd, 240 V complete all as specified and directed.
Supply in replacement hole fastner made up of MS 6" long with complete nut bolt all as specified.Make:as per sample
Supply in replacement hole fastner made up of MS 4" long with complete nut bolt all as specified.Make:as per sample
Supply in replacement heating element of 1.5 KW any type with nut bolt washer complete all as directed.
Supply in replacement FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 1.5 sqmm with approved colour code completed all as specified.
Supply in replacement FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 2.5 sqmm with approved coloured code completed all as specified.
Supply in replacement FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 4 sqmm with approved coloured code completed all as specified.
Supply in replacement FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 6 sqmm with approved coloured code completed all as specified.
Supply in replacement FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 10 sqmm with approved coloured code completed all as specified.
Supply in replacement replacement copper cable flexible 3 core PVC insulated of size 23/.0076 ll as specified and directed by Engr-in-Charge
Schedule of Credit
Pall Associates (BID ID -3483713)
yameen enterprises (BID ID -3489639)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
BOQ_826970.xls
BOQ • 0.36 MB
tenderpage.pdf
Tender Documents • 0.92 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .