Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹45.8 CrAccepted-AOC | ₹45.8 Cr | 1 | Accepted-AOC Qualified |
| 2 | 2₹47.1 CrRejected-Finance R K PATH ITACHALI CITY TOWN NAGAON P O NAGAON P S SADAR PIN 782003 DISTRICT NAGAON ASSAM | NAGAON | ASSAM | 782003 | ₹47.1 Cr | 2 | Rejected-Finance Not Qualified |
Tender Value
₹45.8 Cr
EMD Value
₹91.6 L
Closing Date
8 Nov 2019, 4:00 pmClosed
Chief Engineer, PWD(Roads)
O/o the Chief Engineer, PWD(Roads)
Beautific-n,renov-n of existing footpath and medians by providing kerb stone, ornamental grill, coloured tile, FRP manhole cover etc. on A.T.Rd (Bharalumukh- Maligaon Gate No. 3 (Ch. 1740 M-Ch. 4895 M, Constn of FOB at Kamakhya Gate- SOPD(G)2019-20.
2019_PWD_14462_1
AT Road from Bharalumukh to Maligaon
Open Tender
Civil Works – Roads
365 days
Guwahati
Please refer Tender documents.
5 documents required · 5 mandatory
₹10,000
Yes
Empowered Officer, ASRB
₹91.6 L
Yes
16 Jul 2020
24 Oct 2019
8 Nov 2019
24 Oct 2019
8 Nov 2019
24 Oct 2019
24 Oct 2019 - 8 Nov 2019
Amount
Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) 'By Mechanical Means for items No. 202. a) Cement concrete Grade M15 & M20.
Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) 'By Mechanical Means for items No. 202.b) Dismentalling brick/Tile work b) In Cement Morter.
Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres) 'By Mechanical Means for items No. 202 .c)RCC Gr. M-20 and above
Dismantling of flexible pavement . Dismantling of flexible pavement and disposal of dismentled materials upto a lead of 1000 m , etc complete as directed.
Removal of Unserviceable Soil with Disposal upto 1000 metres ( Removal of unserviceable soil including excavation, loading and disposal upto 1000 metres lead but excluding replacement by suitable soil which shall be paid separately as per clause 305 ).Disposal beyond 1000 m (up to the area out side city)(Considering10.0 km.)
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom,backfilling the excavated earth to the extent required and utilising theremaining earth locally for road work.), ordinary soil , manual means without dewatering . . (v) Ordinary soil , B. Mechanical means
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom,backfilling the excavated earth to the extent required and utilising theremaining earth locally for road work.), ordinary soil , manual means without dewatering . .B) Murshy land, Mechanical means
Providing brick soling in earthen shoulder with stone/best quality jhama brick, sand packed and laid to true line and level and in panel after preparing the subgrade including earthwork in excavation as directed including all labour and materials and if necessary dewatering, complete. a) Brick on flat soling
Providing brick soling in earthen shoulder with stone/best quality jhama brick, sand packed and laid to true line and level and in panel after preparing the subgrade including earthwork in excavation as directed including all labour and materials and if necessary dewatering, complete. b) Brick on edge soling
Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.
Brick masonry work in 1:3 in sub-structure complete excluding pointing and plastering, as per drawing and Technical Specifications
Providing tree guard with Brick masonry work in existing as well as provision for new tree to be plante in the road central verge with reqd. Size as per drawing and specification @ 2.5 m interval and with a exposed height of 100 mm as per drawing and design.Size 1.20m x1.20 m
Providing tree guard with Brick masonry work in existing as well as provision for new tree to be plante in the road central verge with reqd. Size as per drawing and specification @ 2.5 m interval and with a exposed height of 100 mm as per drawing and design. Size 0.80m x0.80m
Sand Filling in Foundation Trenches as per Drawing & Technical Specification
Back filling behind abutment, wing wall and return wall complete as per drawing and technical specification.; (B) Sandy materials
Furnishing and Placing Reinforced/ Prestressed cement concrete in super-structure as per drawing and Technical Specification A) PCC Grade M20 (using batching plant, transit mixer and concrete pump)
Providing pipes 200mm dia for drainage as per drawing and technical specifications
Reinforcement. Supplying, fitting and placing TMT bar reinforcement in sub- structure complete as per drawing and technical specification. (b) With TMT-IS 1786 ( Fe 500) Secondary Producer (ISI approved)
Providing and fixing in position moulded cement concrete block(Kerb) of approved brand of size300mmx450mmx100mm in proper level and grade on footpath edge etc. as directed by the department.
Providing temporary bamboo barricades for Protection purpose with bamboo post of height 2.00m above the footpath at an interval of 1.5mm C/C fixing of bottom support having 2.00m length at an interval of 1.5m C/C tied with jati bamboo horizontally in 3 rows at an interval of 0.90m C/C with carriage of materials from the work site as and directed by the deptt.(after completion of work the contractor is allowed to collect and clearing the unserviceable bamboo from the site and salvage value from the auctioned of the materials is deducted from this rate.)
Weep Hole Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100mm dia AC pipe, extending through the full width of the structure with slope of 1 V:20 H towards drain face. Complete as per drawing and technical specification.
Provided and fixing moulded cement concrete block of , base width-15cm , height- 55 cm, fixing in proper position in road central verge with proper level and grade as directed by the deptt.
a) Planting Permanent Hedges including Digging of Trenches (Planting permanent hedges including digging of trenches, 60 cm wide and 45 cm deep, refilling the excavated earth mixed with farmyard manure, supplied at the rate of 4.65 cum per 100 metres and supplying and planting hedge plants at 30cm apart
b. Maintenance of hedge for 1 year
Providing polished tiles of approved quality, size, shape of specified thickness on pavers over a base of 100mm compacted sand gravel including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department).
Supplying, fitting and fixing ornametal grill on Footpath edge with specified steel section as per drawing and technical specification with all materials and labours etc. Complete as directed by the Deptt.
Supplying, fitting and fixing ornametal grill on central verges with specified steel section as per drawing and technical specification with all materials and labours etc. Complete as directed by the Deptt.
Providing and fixing in position Fibre Reinforced Plastic (FRP) manhole slab from the approved manufacturer as per Drawing & Technical Specification and as directed by the Deptt. a) FRP manhole cover of size 1.80x0.50x0.075 m
Providing and fixing in position Fibre Reinforced Plastic (FRP) manhole slab from the approved manufacturer as per Drawing & Technical Specification and as directed by the Deptt. B) FRP manhole cover of size 1.60x0.50x0.075 m
Cleaning and de-silting of road side drains / cross drains etc. by mechanical means with adequate road safety measures by providing caution boards / safety ribbons /proper barricading where necessary / proper lighting if necessary etc. without damaging the foot paths / slabs / road surfaces etc including immediate disposal of the semi liquid / silt / garbage/Floating materials/ Polythin etc. taken out from the drains/ culverts etc. upto a lead of 20.00 KM from the site within 24 hours as directed keeping the road surface / footpath etc. clean and as directed by the department . De-siltation work will have to be carried out as and when necessary as directed by the Engineer-in-Charge.(Measurement shall be taken on inside of the drain wall )
Restoration of road damaged during construction / renovation of drain and Footpath etc. by providing GSB of 150 mm thick, WBM with gr. III metal of 75 mm thick and ICBP of 80 mm thick as per technical specification as directed with a av. width 1.30 m as per drawing and specification as directed.
Providing fitting and fixing removable iron slab at approach roads with RSJ of size 200x100mm @ 500mm C/C with MS channel of size 150x76x5.5mm and welded etc.. with necessary lifting arrangement etc. as per drawing and technical specification.
Applying one self-priming coat of acrylic emulsion coating of Unicem "Rakshak" brand by thinning 1ltrs of paints with 1ltrs of water over freshly plastered wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth as specified and directed by the department.
Finishing wall with two coats of acrylic emulsion exterior coatings of Unicem "Rakshak" brand of required shade by thinning 1ltr. of paint with 750ml of water to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials as specified and directed by the department.
Extra over item above for every subsequent coat of acrylic emulsion exterior coatings of Unicem 'Rakshak' brand of required shade.
Painting on Steel Surfaces (Providing and applying two coats of ready mix paint of approved brand on steel surface after through cleaning of surface to give an even shade)
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes and conforming to the MoSrt&H specifications
Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand)(i) 90cm equilateral traingle
Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand)(ii) 60cm equilateral traingle
Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand)(iii) 60cm circular
Providing reflective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H’s fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance.
Providing and erecting Median Markers which shall be made of tough, high impact resistant, injection-moulded, thermoplastic body with an isosceles trapezoid structure of length, width and height not less than 15cm, 10cm and 10cm respectively and thickness shall not be less than 1.8 mm. The palstic used for moulding the Median Marker shall have a minimum etc.... and shall be edge protected with no exposed edges which will prevent edge lifting, vandalism, sheeting damage etc. from the manufacturer.
Providing R C C Beam below Pipe railing as Guard beam along the Railway side as per drawing and technical specification.
Tubular Steel Railing on Medium Weight steel channel ( ISMC series) 100 mm x 50 mm (Providing, fixing and erecting 50 mm dia steel pipe railing in 3 rows duly painted on medium weight steel channels (ISMC series) 100 mm x 50 mm, 1.2 metres high above ground, 2m center to center, complete as per approved drawings.Along railway track from Bhutnath to Kamakhya app. Road Nursery & LCB college to Gate no 3 in stretches.
Providing C C Guard wall along the Railway track from Durgasorobor to Nursery as per drawing and technical specification.
Construction of Foot over bridge at Mekhelaujua point on A T Road with composite structure as per drawing and design-- Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. Up to a depth of 2.00 M below the existing ground level. In ordinary soil
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). Note: Truck Mounted rotary/TMR/Tubewell boring machine shall not be used .600 mm dia piles
a.Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing. Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge. Single pile above 50 tonne and upto 100 tonne Safe capacityInitial test (Test Load 2.5 times the Safe capacity)
Lateral load testing of single pile in accordance with IS Code of practice IS : 2911 (Part IV) for determining safe allowable lateral load on pile :Upto 50 tonne capacity pile
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge(Note :- Cement content considered in this item is @ 330 kg/ cum.Excess/less cement used as per design mix is payable/recoverable separately). All works upto plinth level
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge(Note :- Cement content considered in this item is @ 330 kg/ cum.Excess/less cement used as per design mix is payable/recoverable separately). All works above plinth level upto floor V level
Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable /recoverable separately.Providing M-35 grade concrete instead of M-25 grade BMC/RMC. (Note : Cement content considered in M-35 is @ 350 kg/ cum)
Supplying, fitting and fixing in position reinforcement bars confirming to relevant I.S. Code for R.C.C. work/ R.B. walling including straigtening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level.) From primary Producer: TATA/ SAIL/ Jindal Steel/ Shyam Steel/ RINL TMT Corrosion resistance steel (CRS) reinforecement bars
Providing form work of ordinary timber planking so as to give rough finish including centering , shuttering, struting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m & removal of the same for in situ reinforced concrete and plain concrete work in:Foundations, footings, bases of columns, pile cap, raft and mass concrete work etc.Using 25 mm thick plank
Vertical surfaces such as walls (any thickness), parapet walls, partition, walls of septic tank, inspection pit and the like including attached pilasters, butresses, plinth and string courses.Using 25 mm thick plank
Flat Surfaces such as soffits of suspended floors, roofs, landings, cantilever slabs, chajjas, balconiess and the like.a.Floor etc. upto 200 mm in thickness. i)Using 25 mm thick plank
Sides and soffits of Beams, beam haunchings, cantilever girders, bressumers, lintel and horizontel ties.a.For depth not exceeding 1.0 M ii)Using 25 mm thick plank
Columns, Pillars, Posts and Struts a.Suqare, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face.ii)Using 25 mm thick plank
Structural steel Built-Up-Girder (BUG) Providing and launching Steel Truss of Structural steel BUG Superstructure including painting complete as per drawing and technical specifications under section 1900 of MOST)
Providing and applying two coats of fire retardant paint on cleaned wood / ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendations of manufacturer to make the surface fire retardant.
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 10 x 60 mm
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 10 x 80 mm
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 10 x 120 mm
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 10 x 140 mm
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 10 x 160 mm
Designing, Providing, installing and fixing factory finished customed design pregalvanized high tensile steel joists manufactured from G350 Z275 confirming to IS:277-1992, minimum coating of galvanizing 275 gm/sqm, minimum yield stress 35 MPa & minimum tensile strength of 380 MPa placed 1.23 metre apart to support the load of slab etc as per the design & directions of Engineer-in-Charge.
Providing and fixing special adjustable lockbars of mild steel E-250 to support the temporary plywood for work between joists during construction as per design & directions of the Engineer-in-charge.
Centering and shuttering with 12mm thick shuttering plywood confirming to IS 4990:2011 and removal of form at all heights. Plywood will be supported on lock bars. Suspended floors, roofs, landings, balconies and access platform.
Providing and fixing roofing consist of 0.8 mm thick galvanized steel deck sheet confirming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3mm laid at 100x100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beam with shear studs. (Structural steel like Beam, column, joists etc. & concrete of different grade as per design will be paid separately).
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Extra for pre finished nosing to treads of steps of Granite stone.
Extra for Granite stone flooring in treads of steps and risers using single length up to 2.00 metre .
Deduct for not using 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) bedding in laying of floor tiles/Granite stone and jointing with grey cement slurry @ 3.3 kg/ sqm.
Fixing glazed/ Ceramic/ Vitrified floor tiles/Granite stone with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness.
Providing SUN ROCK HIGH CTS/ DEVI paver block/tiles of concrete grade M30 or above of approved quality, size, shape of specified thickness over a leveling bedding layer of 30mm compacted sand over a base course of WBM or PCC (Base course to be paid separatly) including cutting where necessary finished with spreading , sweeping jointing sand and compacting the pavers using vibrating compactor as specified and directed. SUN ROCK HIGH CTS/ Devi Tiles (Pavers) (b) 60 mm thick
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Kota stone slab flooring of 18 mm thick over 20 mm thick base of cement mortar 1 : 6 (1 cement : 6 coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete. 550mm x 550mm
Kota stone slab of 18 mm thick in riser of steps, skirting, dado and pillars laid with 10 mm thick cement plaster 1 : 3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete. 550mm x 550mm
15 mm cement plaster in single coat on rough side of single or half brick walls for interior plastering upto 1st floor level including aries or rounded angles not exceeding 80mm grith and finished even and smooth including curing complete as directed.d)In cement mortar 1:6
(a) White washing with lime on wall surfaces (two coats) to give an even shade including throughly brooming the surface to remove all dirt, dust,mortar drops and other foreign matter.
Providing two coats of Birla White Wall Care Putty (Water Resistance White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm).Thickness = 1.5 mm thick
Wall painting (two coats) with acrylic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J&N paint/ Narolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. a)Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J&N paint/ Narolac).
Providing and fixing 18mm thick Granite stone work for wall lining upto 10 m height in cement mortar 1:3 (1cement : 3 coarse sand) including pointing with white cement mortor with an admixture of pigment to match the granite shade complete as per direction of Engineer-in-charge.
Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-in-charge.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): a)With float glass panes of 4.0 mm thickness (weight not less than 10 kg/ sqm)
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places."
Roof System: Supply and fixing of “SELF SUPPORTED” SECRET FIX STANDING ROOFING SYSTEM IN 0.9mm THICK AA 3004 ALUMINIUM ALLOY. The general roof-construction shall comprise from bottom to top: Top layer : Minimum 65mm tall and 400mm wide Aluminium self-supported standing seam insulated roofing system manufactured from Marine Grade aluminium alloy EN AW – 5052 as specified in BSEN 1396:2007 (DIN 1725) material thickness of 0.90 mm in PVDF 2 finish of thickness 25 ± 5 μm on the exposed surface. The profiled roof panel should have 24nos. of Micro ribs of height 1.5mm in between 3Nos of Mini ribs for extra strength/ rigidity. Roof accessories for Verge, Ridge and Eave will form part of supply. The material properties shall be as follows: Ultimate tensile strength: minimum 200 N/mm2, 0.2% Proof Stress: min 180 N/mm2, Modulus of elasticity: 70,000 N/mm2. Sheets are to be laid to meet the requirements of the building geometry and fixed on Aluminum clips. Clip to be fixed to the top hat/purlins with SS 304 screws only. The roofing system provider shall be certified with a British Board of Agreement and should have both Factory Mutual (FM-4471) & UL Certification (UL-90). All installation is to be carried out by approved trained roofing installer. The installation team shall be fully trained and approved by the supplier. Halter – Aluminium Halters – in grade 6082 (T6), of suitable height with thermal barrier pads to be fixed to the sub purlins with SS 304 screws only Flashings: Flashings manufactured from aluminium alloy AA 3004 (AlMn1Mg1) as specified in BS EN 1396: 2007 minimum material thickness of 0.9 mm and Fluorocarbon PVDF finish on the exposed surface. The material shall be of the same colour. Girth – max Girth 578 all complete as specified and as directed by the Engineer-in-Charge.
316 Grade S.S. Handrail & Flat Balustrade with Double pre laminated toughened glass Providing and fixing of side Mount Modular Glass Railing with Stainless steel 316 Handrail fixed with SS Flat Balustrade & Handrail made of 50 mm dia tube of 1.50 mm thick with double glass holding accessories with 316 grade side bracket patti and 3 No.High tensioned anchors and fasteners ( Bends, Pipe connector & flat Balustrade) at required locations, total height of railing including handrail 1050 mm from finished floor level, for Glass 13.52 mm [6+1.52PVB+6] thick Straight Toughened Glass (Up to 775mm height ), no welding to be done at site, Complete railing will be factory finished & Fixing of Glass connector in Vertical post through Flow drill threading process for extra grip, all as per manufacturer’s specifications and Engineer Incharge’s directions complete in all respects.
Providing and fixing stainless steel (Grade 304) railing made of hallow tubes, chanells, plates etc. including welding grinding buffing, polising and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i.e. fixing railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer in charge.(for payment purpose only weight of stainless steel members shall be considered excluding fixing assessories such as nuts, bolts, fasteners etc.)
Customized Perforated Screen Panel Cladding Supply and fixing of Luxalon® or equivalent make: Customized Perforated Screen Panel Cladding fixed system manufactured by M/SHunterDouglas or equivalent make. The Screen panels of various sizes maxing to 900mmx4200mm as per design requirement shall be manufactured from high corrosion resistant aluminium aloy of 2.5-3.00mm thickness which shall be fixed to a suitable and rigid substructure which will be paid seperately. Screen panel shave customized perforation as per architects design and is to be provided to suite the design panels. Panel sshall be coated on visible side with Exterior Architectural highly durable coating in approved color minimum 10 years warranty through in-house high precision powder coating unit. The panels of required length and height shall be fixed to substructure by means of special components as per Hunter Douglas World wide standards or equivalent make. Panels shall be bending from all four sides and shall have extended flanges to accommodate clamps. Installer or Client shall provide sub frame made from Al./Steel/GI. The Panels shall be fixed to a suitable structure (which will be paid seperately )by means of fixing side extrution fixed to the panel at appropriate centers to proprietary metalc lampas per the proprietary HDI design to a support sysem taking in to account the relevant live loads and a dead load. There will be a provision for an expansion joint of 20mm be tween two adjacent panel ends. Installation shall be carried out as per manufacturer recommendation. Green-procertification: For LEED certification by Indian Green Building Council (IGBC) and ISO 9001: 2008 Quality Management System Certification. Coating-In-house Powder Coating linewith Nano technology & catalytic converter in India: For superior powder coating finishes with automatic electrostatic robotic coating technology for uniform coating and Five (5) times cleaning process with Nano Technology for better adhesion and corrosion protection all complete as specified and as directed by the Engineer-in-Charge.
Providing and fixing 12 mm thick frameless toughened glass partitions of approved brand and manufacturer, including providing and fixing partitions at top & bottom with aluminum channel etc. all complete as per direction of Engineer-in-charge
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. i) In Sub-structure upto plinth level including dewatering if necessary d)In proportion 1:6
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed.ii)In super structure above plinth level upto 1st floor level d)In proportion 1:6Gr. Floor
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces
Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres)(i)Lime /Cement Concrete (i)By Manual Means A)Lime Concrete, cement concrete grade M-10 and below
Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres Dismantling Brick / Tile work B)In cement mortar
Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.
Dismantling of Flexible Pavements (Dismantling of flexible pavements and disposal of dismantled materials up to a lead of 1000 metres, stacking serviceable and unserviceable materials separately) (ii)By Mechanical Means A)Bituminous course
Dismantling Kerb Stone (Dismantling kerb stone by manual means and disposal of dismantled material with all lifts and up to a lead of 1000 metre)
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading,transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
LIft- Design, manufacture, supply,transportation, installation, testing, commissioning, approvals (All local/ State/ Central statutory bodies) and handing over in satisfactory working conditions of Elevators meeting in all respects the intents of specifications & drawings complete with a) Scaffolding & minor civil, mechanical and electrical works b) Steel items with directional control of cars (as required) with ACVVVF control with scratch proof -textured stainless steel sheet enclosures, automatic centre opening car & landing doors, hard wood flooring with 25mm recess including the cost of providing 2 weeks satisfactory trial operation and testing at full design load and safely checks for sudden breaks, speed, etc. as directed and including the cost of providing free comprehensive maintenance service during Defect Liability Period of 12 months after Virtual completion and satisfactory handingover, complete as per specifications as required and as below: Note: All the passanger elevators shall be with vision panel of size 200x300mm on CAR and lobby doors.Elevator in Shaft of dimensions 1900 mm x 1900 mm (W x D) for minimum payload carrying capacity of 8 passenger/ 544 kg (Simplex Control) having a travel speed of 0.75 metre/ sec and travel height of 10.2 Mtrs. (approx.) with 2 Stops and Microprocessor based control suitable for operation on 415 V, 50 Hz, 3 phase A.C. electric supply complete as per specifications. (Ground - 1st Floor)
ESCALATORS (IP 67) Supply, Installation, testing and commissioning of reversible escalators 13 Meter (approx. length) having capacity of 9000 passengers per hour at an operating speed of 30 linear meter per minute, having width not less than 1000mm between exterior panel, suitable for following rise from floor to floor with electric motor, control, latest safety devices, control panel i/c stainless steel cladding etc. for operation on 415V, 3 phase, 50Hz, AC supply system as specified and as required at site with auto start and auto stop Travel rise from floor to floor (a) 6.20 mtrs.
DG SET (100 KVA) Supplying including installation, testing and commissioning of Air/ Water Cooled Diesel Generator set coupled to suitable alternator of 220/415 V, AC, 1/3-Phase 0.8 p.f. Mounted on a 1) M.S. Fabricated base frame., 2) M.S. Fuel tank of required capacity., 3) Residual Silencer., 4) Standard Control Panel. 5) Suitable batteries with lead., 6) First fill of lube oil., 6) Acoustic Enclosure complete with all accessories as specified and directed by the department conforming to IS comprising the Technical Specification., as per manufacturer. (Range FROM 5 KVA TO 625 KVA) Kirloskar green/ bliss, Leyland, Volvo Penta, Perkinson, Mahindra, Greaves, Escort engine and Kirloskar, Stamford, Leroy somer alternator. KVA-PHASE- Approx size- Approx Wt - Cooling 100-3-3200x1300x1805 1950Kg W/C
Supply and fixing Exhuast piping for DG Set's with following sizes of MS pipes conforming to IS -3589 with bends, tees, reducers, fleixble connection etc. providing & fixing suitable self supporting arrangement duly painted at suitable intervals, supplying & fixing of 150 mm thick Rock wool matrix (3x50 mm. thick) insulation of density 150 Kg per cubic metre on all sides of Exhaust pipe with chicken mesh wrapping and 22 SWG aluminium sheet cladding , suitable for outdoor installation, guide support, expansion joint, SS bellows complete as required and as per specification. 100 mm dia MS pipe (4.85 mm thick)
MS STRUCTURE Fabrication, supply & erection of MS support for fixing of exhaust piping (Heavy Duty) and MS structure including Angle / chanels / flats / beam as per approved drawings for supporting of DG exhaust stack from ground. floor level and above terrace level complete in all respect.
Providing and fixing following rating and breaking capacity and 4 pole MCCB with thermomagnetic release and terminal spreaders in the above panel board including drilling holes in cubicle panel, making connections, etc. as required Rating 63 A, 30kA, FPMCCB, 415V.
Supplying, Laying , Inter Connecting and Terminating of LT UG cable having aluminium conductor PVC insulated, sheathed, galvanised, steel wire/steel tap armoured cable with PVC outer sheathing 1.1 KV class.(68/4) - Class PVC Cable 3.5 core 120 sqmm ---- With all Lead & Lifts etc., complete. as per the detailed specifications and the Directions of Engineer In charge of the work, Power Cables, Solid Aluminum Conductor Up To 10 Sqmm Balance Stranded Conductor, XLPE Insulated, Cores Laid Up, PVC Innersheathed, Armoured , Core - 3.5, 120 sqmm , A2XFY, 1100V Grade As Per IS 7098(Part 1) 1988
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3½ X 120 sq. mm (45 mm)
Supplying, Laying , Inter Connecting and Terminating of LT UG cable having aluminium conductor PVC insulated, sheathed, galvanised, steel wire/steel tap armoured cable with PVC outer sheathing 1.1 KV class.(68/4) - Class PVC Cable 3.5 core 70sqmm, , A2XFY, 1100V Grade As Per IS 7098(Part 1) 1988 ---- With all Lead & Lifts etc., complete. as per the detailed specifications and the Directions of Engineer In charge of the work
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. ( DSR 2016, Item code : 9.1.23, Pg No 35, 3½ X 70 sq. mm (38 mm)
Supplying, Laying , Inter Connecting and Terminating of LT UG cable having aluminium conductor PVC insulated, sheathed, galvanised, steel wire/steel tap armoured cable with PVC outer sheathing 1.1 KV class.(68/4) - Class PVC Cable 4 core 35sqmm, A2XFY, 1100V Grade As Per IS 7098(Part 1) 1988 ---- With all Lead & Lifts etc., complete. as per the detailed specifications and the Directions of Engineer In charge of the work
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade, 4 core 35sqmm as required.
Supplying, Laying , Inter Connecting and Terminating of LT UG cable having aluminium conductor PVC insulated, sheathed, galvanised, steel wire/steel tap armoured cable with PVC outer sheathing 1.1 KV class.(68/4) - Class PVC Cable 4 core 10 sqmm, A2XFY, 1100V Grade As Per IS 7098(Part 1) 1988 ---- With all Lead & Lifts etc., complete. as per the detailed specifications and the Directions of Engineer In charge of the work
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
Supply, installation, testing & commisioning of Flush/Recess mounted luminaire with housing made of CRCA sheet steel powder coated complete with electronic ballast and Acrylic diffuser, 4 Feet Fittings, 40 Watts with LED lamp and all other accessories etc. Luminaire to be suitable for outdoor use only, meeting 'IP class: IP65 (weather proof enclosure for outdoor installation), (Cat Ref No Magnum 40 of Havells make or Equivalent).
Supply, installation, testing & commisioning of 80 watts LED Street Lighting luminaire with housing made of CRCA sheet steel powder coated complete with electronic ballast and Acrylic diffuser, with LED lamp and all other accessories etc. Luminaire to be suitable for outdoor use only, meeting 'IP class: IP65 (weather proof enclosure for outdoor installation).
Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in Existing /Provided M S Tubes( square/Rectangular tubes) provided in the steel structure, using copper PVC insulated multi strand 2X2.5Sqmm and 1X1.5 Sqmm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a GI Modular Boxes omplete for each outlet.. I. Point wiring using class A Materials b) Medium point above 3Mtr up to 6Mtr from tapping point to Luminaire ---- With all Lead & Lifts etc., complete. as per the detailed specifications and the Directions of Engineer In charge of the work
6A sockets(Material & Labour) with all necessary accessories.
Supply & Laying of 2Rx2.5sqmm+1Rx 1.5sqmm cu cable through 19mm pvc conduit(Material & Labour)
Earthing with G.I. ear th pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Earthing with G.I. ear th plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip ear th electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supplying & Fixing CCTV Camera - 2 M.P.
Supplying & laying of CCTV Coaxial cable (2 Coils)-1coil=80Mtrs) (complete with G.I Saddles & Spacers at 0.3 mtr)
Supplying & Fixing of CCTV DVR (Digital Video Recorder)Box
4U Rack with lock accessories
Supply & Fixing of Fire Extinguishers-ABC Type
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.a)150 mm x 50 mm x 1.6 mm.
Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. a)150 mm x 50 mm x 1.6 mm.
Supplying and installing following size of perforated pre-painted M.S. cable trays reducers with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. a)150 mm x 50 mm x 1.6 mm.
Supplying and installing following size of perforated pre-painted M.S. cable trays Tee’s with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. a)150 mm x 50 mm x 1.6 mm.
Supplying and installing following size of perforated pre-painted M.S. cable trays cross members with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.a)150 mm x 50 mm x 1.6 mm.
Operational Maintenance Cost of foot over bridge for 4 years after defect liability of one year i.e. 5 yearsof structure and mechines etc. including providing necessary security guard, operators etc. in shift manner 24x7 (including holidays) ,running standby devices with all fuel and labours, cost for minor repairing and maintaining warenty etc. from concerned manufacturers when requires etc as directed by the deptt. complete.
RCN Constructions Pvt Ltd
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid