| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.6 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹36.2 L+₹5.9 L (19.5%)Rejected-Finance 00 BALITIKURI BALITIKURI NASKARPARA HOWRAH WEST BENGAL 711113 | HOWRAH | WEST BENGAL | 711113 | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹38.1 L+₹7.8 L (25.8%)Rejected-Finance | L3 | Rejected-Finance HIGHER BIDDER | |
| 4 | L4₹39.2 L+₹8.9 L (29.5%)Rejected-Finance 1 1 MEREDITH STREET KOLKATA 700072 INDIA | KOLKATA | WEST BENGAL | 700072 | L4 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹31.3 L
EMD Value
₹62,660
Closing Date
18 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER (CENTRAL) KOLKATA
GARRISON ENGINEER (CENTRAL) KOLKATA T-37 NAPIER ROAD HASTING KOLKATA -700022
8371/E8
2021_MES_467509_3
8371
Open Tender
Miscellaneous Works
Item Rate
180 days
KOLKATA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (CENTRAL) KOLKATA
₹62,660
Yes
22 Apr 2022
29 Dec 2021
19 Jan 2022
29 Dec 2021
18 Jan 2022
6 Jan 2022
29 Dec 2021 - 5 Jan 2022
60 days
Amount
SCHEDULE 'A' (B/R WORKS):-
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, in roof covering including ridges and keeping serviceable sheets in safe custody for reuse in the work complete as directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
Demolition of plain cement Concrete of any description and in any position not otherwise specifically provided for as in padding of roof concrete ( Un-reinforced) other than Ground Floor etc complete all as specified and directed.
Demolition of plain cement Concrete ( Un-reinforced) in ground floor and pavings n.exc 15 Cm thick above or below Ground level etc complete all as specified and directed.
Demolition of Reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water complete all as specified and directed
Taking down existing old unserviceable roof membrane of any type and removing the debris from the site etc complete all as specified and as directed.
Taking down chowkats or frame, n.exc 1.5 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and directed.
Taking down chowkats or frames, exe 1.5 but n.exc. 4 Sqm in each with shutter (without taking off shutter from the frame) complete all as specified and directed.
Taking up or down 15 mm bore steel tubing & connections complete all as specified and directed.
Taking up or down 20 mm bore steel tubing & connections complete all as specified and directed.
Chipping carefully o damaged, detoriated, spalled, debinded and weak concrete from the beams, coloumns, walls, roof of staging structure upto any height of building including removal of rubbish off the premises upto 50m as per direction of Engineer-in-Charge.
Materials and labour Drilling 20mm dia holes in RCC slab, wall coloumns, beams to a depth of 200mm for anchoring steel reinforcement bars including washing with water, inserting polyster resin, grout in holes and all as directed and as dper manufacturers instructions complete all as specified and as directed.
Materials and labour Removing rust from existing corroded reinforcement by means of application of Rust remover such as Hind Rust Clean of M/s Hindcon or equivalent product of make Pidilite/ Fosroc and then washing the same to make the reinforcement scale free as per the direction of Engineer-in-Charge.
Materials and Labour Anticorrosive paint such as Hind anti Rust of M/s hindcon or equivalent product of M/s Pidilite/ Fosroc on cleaned reinforcement as per manufacturer's instruction complete as per direction of Engineer-in-charge. Note:- Payment to be made on 25% of exposed area.
Materials and Labour Bonding coat based on polymer modified cementitious materials such as Nitobond SBR of M/s Fosroc/ Hind Styrene BR of M/s Hindcon or equivalent product of M/s Pidilite @ 0.50 Kg/Sqm due to rough concrete surfaces to act as bonding agent between old and new concrete as per manufacturer's instructions as per direction of Engineer-in-Charge.
Materials and Labour Pressure guniting 40mm thick at a pressure not less than 6Kg/ Sqm to surface of coloumn, beam, ceiling and similar structural members in Cement mortar 1:3 duly modified the mortar with Hind Styrene of M/s Hindcon chemicals or Nitobond SBR of M/s Fosroc or equivalent product of M/s Pidilite @ 7 Kg for 50Kg Bag of cement per sqmand the plasticiser Hindplasts Super of M/s Hindcon Chemicals or Conplasts SP 337 of M/s Fosroc or equivalent product M/s pidilite @ 400 gms ( the mortar to be applied when the bonding coat is still green) complete as per manufacturer's instructions as per direction of engineer-in-Charge. Notes for item Nos 16 to 21:- Rates include necessary scaffolding and formwork including safety measures.
Excavation in trenches not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out as in soft/loose soil for foundation of pole, laying of electric cables etc complete all as directed by the Engr-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 Cm thick complete all as specified in soft/loose soil and as directed by Engineer-in-Charge.
Removing excavated materials of soil not exc. 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-Charge.
Materials and Labour Hardcore of gauge n.exc 63mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surfaces complete all as specified and as directed.
Supply and laying dry coarse sand as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 Cm (15 Cm under the cable & 8 Cm over the cable) and gently punned down to 18 Cm thickness complete all as specified and as directed by the Engr-in-Charge. Note:- Thickness after punning down shall be measured for payment.
Supply and laying in trenches Bricks, sub class 'B' over burnt (kiln burnt) old size bricks, laid flat dry with width of the bricks laid to the axis of the cable for protection of cable complete all as specified and as directed by the Engr-in-Charge.
Material and Labour Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.
Material and Labour for plain cement concrete 1:3:6, type B-0 (using 12.5mm graded crushed stone aggregate) for embedding holdfast, bed block, cills, etc including necessary form work complete all as specified and directed.
Materials and labour 75mm thick Reinforced cement concrete type B0 (1:2:4, using 12.5mm graded crushed stone aggregates) for chajjas, roof fascias, lintels, and the like similar work using 8mm dia TMT bars fabricated to existing RCC members including necessary formworks complete all as specified and as directed.
Material and Labour for plain cement concrete 1:2:4, type B-0 (using 12.5mm graded crushed stone aggregate) as in roof padding and benching and filleting complete all as specified and directed.
Material and Labour Brick work with pulverized fly ash bricks of designation 7.5, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directeded.
Supply and fix 2nd class hard Wood, 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified & directed by the Engr-in-Charge.
Supply and fix 35 mm thick, Factory made Flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides complete all as specified and directed.
Supply and fix aluminium anodised 1.5mm thick powder coated , three track sliding window frame with shutters as per Drg no. CWE/KOL/TD-33 of section No. 1F-1F including all necessary joining cleats, hold fast, rubber gasket, snap beading , locking arrangements roller handles ( 03 Nos) etc complete all as specified and as directed:- Note:- (i) All window member including fittings & fixtures i.e. frame, track, shutter frame etc shall deemed to be included in the rate quoted by tenderer. (ii) Only glass for window & wire mesh shall be measured and paid separately under relevent items of these BOQ.
Supply and Fix Welded steel wire fabric of weight not more than 4Kg/Sqm fitted by Mild steel nails fitted to wood or steel member complete all as specified and as directed.
Supply and fix Pressed steel frames of size 105mm x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed complete all as specified and directed. Note:- Pressed steel frame shall be filled with PCC type C0 ( 1:3:6, using 12.5mm graded crushed stone aggregates) and cost of same shall deemed to be included in the rate quoted by the tenderer in this Item.
Supply and fix Pressed steel frames of size 125mm x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed complete all as specified and directed. Note:- Pressed steel frame shall be filled with PCC type C0 ( 1:3:6, using 12.5mm graded crushed stone aggregates) and cost of same shall deemed to be included in the rate quoted by the tenderer in this Item.
Supply and fix 100mm butt hinges stainless steel complete all as specified and as directed.
Supply and fix 200mm barrel tower bolt stainless steel complete all as specified and as directed.
Supply and fix 150 mm stainless steel 'D' handles, fabricated type, anodised complete all as specified and as directed.
Supply and Fix 300mm long stainless steel sliding door bolt with hasp, staple(bolt type) and fixing clip of sheet and fixing bolts complete all as specified and as directed.
Supply and Fix stainless steel door stopper complete all as specified and as directed.
Supply and fix Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aparture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed.
Supply and fix Drappery rod made of electric resistance welded MS pipe of 21mm dia having a coating of corrugated virgin PVC extrusion and cover with ABS plastic complete all as specified and as directed.
Supply and fix closed type stainless steel bracket for drappery rod fixed to wall with fixing arrangements complete all as directed by Engineer in Charge.
Supply and Fix Mild steel Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and as directed.
Supply and Fix Mild steel Rolled sections as in main and cross beams, hip and jack rafters; wind tie, purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe-290, Gde E-165 complete all as specified and as directed.
Supply and Fix Mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment confirming to Fe-290 Gde E-165 complete all as specified and as directed.
Supply and Fix Mild steel Screw bolts ( machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends and each screwed end to be fitted with washer and one hegonal or square nut of 11mm to 15mm dia and length of bolt 22.5 Cm to 30 Cm long complete all as specified and as directed.
Material and Labour for Mild steel framed work such as grills, gratings, gates etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bar, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-410-0 Gde E-250 complete all as specified and directed.
Supply and fix 4mm thick suspended false ceiling HPSC ( High pressure Steam curved) pre primed fibre cement fibre cement non asbestos building board "E' board 'Clasic" of M/s everest Industries or equivalent with aluminium powder coated angle, channel and Tee section duly suspended with 4mm dia GI hanger fixed with GI hooks 4mm dia and fastener as required at site including two caots of acrylic distemper complete all as specified and as directed .
Supply and fix Pre-Painted galvalume aluminum zinc coating GI based corrugated / semi corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Materials and labour Roof treatment with polymeric water proofing membrane as under :- (a) Preparation of newly padding concrete surfaces over roof. (b) Applying 10mm thick screed bed in Cement mortar 1:3 when the concrete is green including WPC as per manufactturer's directions (c) Material and Labour for applying a coat of bituminous primer @ 0.40 ltr/Sqm and allow to dry. (d) Supply and laying APP membrane 3mm thick (minimum), weighing 3.6 Kg/m² reinforced with polyster non woven fabric (weighing not less than 160 gms/Sqm) shall be applied by torch application including two coats of Bitumen based UV reflective paint with aluminium finish over APP membrane. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction complete all as specified and as directed.
Material and Labour for 75 mm thick, plain cement concrete 1:4:8, type D2 (using 40 mm graded stone aggregate) as in sub base complete all as specified and directed.
Material and Labour for 25 mm thick, plain cement concrete 1:2:4, type B0 (using 12.5 mm graded stone aggregate) as in sub base of flooring complete all as specified and directed.
Materials and labour 75 mm thick, plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth proction laid in panels, finishing the top surfaces even and smooth using extra cement complete as specified and directed. Note:- Construction joints will be provided at interval of 2.50m length and filled with bitumen 80/20 mix with sand in ratio of 1:3 and cost of same shall deemed to be included in the rate quoted by the tenderer.
Materials and labour Non-skid, ceramic, joint free coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 Sqm but n.exc 0.38 Sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed by Engineer-in-Charge.
Materials and labour Non-skid, ceramic, joint free coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 Sqm but n.exc 0.38 Sqm, in vertical surfaces such as skirtings, dados, risers etc, set and jointed in neat cement slurry and pointed in white or coloured cement ot match the tiles over and including 10mm thick backing course in CM 1:4 for receiving tiles. complete all as specified and directed by Engineer-in-Charge.
Materials and labour Glazed ceramic colour tiles, joint free as in vertical surfaces such as skirtings, dados, risers etc of size 450 x 300 x 6-7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement ot match the tiles over and including 10mm thick backing course in CM 1:4 for receiving tiles complete all as specified and as directed.
Materials and Labour Pre polished Chequered cement concrete tiles of size 400mm x400mm x24-25mm thick, with grey cement and no pigment, jointed in neat cemnt slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and as directed .
Material and Labour Rendering 15mm (10 + 5 mm) thick in cement mortar 1:4 on fair faces of brick work or concrete surface in two layers each mixed with integral water proofing compound @ 2% by weight of cement (WPC shall be mixed with top layer only i.e 5mm thick) finished the surfaces even and smooth without using extra cement complete all specified and as directed. Note : - Water proofing compound shall be measured and paid separately as "Supply only" item under relevant item of these schedule.
Material and Labour Rendering 15 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement complete all as specified and directed.
Material and Labour Rendering 5 mm thick in cement mortor 1:3 on concrete surfaces as in ceilings (sunshed, chajja etc) and finishing surfaces even and smooth without using extra cement complete all as specified and directed.
Material and Labour Applying polymer modified cement mortar rendering 20mm thick in CM 1:3 on wall duly mixing polymer modifier "Nitobond SBR of M/s fosroc Chemicals or Hind Styrene BR of M/s Hindcon Chemicals Ltd or equivalent porduct of M/s Pidilite Industries" @ 7 litre per bag of cement complete all as specified and directed.
"Supply only" liquid water proofing compound (ISI marked) complete all as specified and directed. Make:- STP NO 1/ PEDILITE(DR FIXIT)/ FOSROC/ CICO/ SIKA
Materials and Labour Cutting out existing cracks in concrete surfaces forming grooves of 25mm x 40mm size, cleaning the groove throughly with blower, applying primer coat of mix of IPH CC Resin & Hardner in equal proportion with suitable brush to form a film on the surface of groove, filling the groove with putty made by mixing IPH CC Resin, Hardner and admixure in the proportion of 1:1:4 and finally applying the sealing coat of same mix and in the manner primer coat is applied with following min coverage per Running Metre length of groove complete all as directed by engineer-in-Charge. Materials Priming Coat Putty Filling Seal Coat Resin 60 gms 100 gms 40 gms Hardner 60 gms 100 gms 40 gms Admixure - 400 gms - Make of materials :- Fosroc / Hindcon chemicals ltd / Sika / STP.
Materials and labour Preparation of newly plastered external surfaces of any description and applying two coats of Exterior emulsion paint ( weather coat) with silicon additives of any colour / tint over a coat of primer upto any height of building with necessary scaffolding with safety measure complete all as specified and directed.
Materials and labour Preparation of newly internal wall surfaces and applying two coats of Acrylic distemper of any colur / tint over a coat of primer over white cement based wall care putty complete all as specified and directed.
Materials and labour Preparation of newly internal ceiling surfaces and applying two coats of Acrylic distemper of any colur / tint over a coat of primer over white cement based wall care putty complete all as specified and directed.
Supply and fix 4mm thick Tinted glass 4.80mm thick, pin head type and glazing in square exc 0.50 sqm in each pane complete all as specified and directed by Engr-in-Charge.
Material and Labour Preparation of new wooden surfaces of any description, over 10 Cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint of any colour / tint over a coat of pink primer complete all as specified and directed.
Material and Labour Preparation of new steel surfaces of any description, over 10 Cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint of any colour / tint over a coat of red oxide primer complete all as specified and directed.
Supply and fix Bib cock 15 mm bore cast copper alloy chromium plated with crutch or butterfly handle screwed for CPVC pipe or for brass ferrule etc including taking down old unserviceable one complete all as specified and directed. Make- Cera cat part no. F2002151 or equivalent model as specified in Particular specification.
Supply and fix in repair stainless steel kitchen sink without drainage board of overall size 495mm x420mm of bowl size 410mm x 330mm x160mm, made of 1mm thick stainless steel sheet with CP waste coupling including ball and chain 300mm long with brass cap rubber plug, 32mm bore PVC waste pipe(heavy duty) 90 Cm long, and bedded in cement mortar and fixed on CP cantilever brackets, complete as directed. Make : Bluestar/ Nirali/ prayag. .
Supply and Fix Rotational moulded HDPE water storage tanks of 1000 ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position,tripple layered, ISI marked complete, screwed for iron pipe or brass ferrule including 20mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed complete all as specified and directed including taking down old unserviceable tank with ball cock. Make:- Sintax/ Polycon and Make of Ball cock:- Prayag/ Polytuf/ Shakti.
Supply and fix 20mm outer diameter of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls / ceilings or laid in floors complete all as specified and as directed including taking out old unserviceable PVC pipe of any type.
Supply and fix 25mm outer diameter of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls / ceilings or laid in floors complete all as specified and as directed including taking out old unserviceable PVC pipe of any type.
Supply and fix 110 mm bore, PVC (SWR) pipe, single socketed, in any length with rubber ring joints fixed to wall etc complete all as specified and directed including taking down old unserviceable PVC(SWR) pipe with unserviceable fittings.
Supply and fix 110 mm bore, PVC (SWR) pipe, double socketed, in any length with rubber ring joints fixed to wall etc complete all as specified and directed including taking down old unserviceable PVC(SWR) pipe with unserviceable fittings.
Supply and fix 110 mm bore, PVC (SWR) bends with access door of any radius complete all as specified and directed.
Supply and fix 110 mm bore, PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and directed.
SCHEDULE 'A' (E/M) WORKS):-
Taking down carefully unserviceable copper / aluminium point wiring (light, fan, socket or power) including all fittings such as switches, socket, ceiling roses and fittings complete and making good the disturbed surfaces complete all as directed by Engineer-in-Charge.
Material and labour for Point wiring with PVC insulated and unsheathed FRLS cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC casing caping of suitable size with all accessories including fabricated MS terminal boxes fixed flush with wall surface with 3 mm thick plastic masonite laminated sheet top cover fixed with cadmium screw for mounting switches, sockets, regulator etc including 1.5 sq mm FRLS stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one light or fan point controlled by one switch single pole one way for light/ ceiling fan/ call bell point. Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board..
All as per item No.85 here-in-before but one 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed by Engineer-in-charge.
All as per item No 85 here-in-before but for one 15/16 Amps switch socket outlet on independent board with 2.5 Sqmm PVC (FRLS) insulated un-sheathed copper conductor cable multistranded conductor 1100 volts grade and 2.5 Sqmm copper conductor cable (FR) as earth continuity conductor complete as directed.
Supply & fix Switch piano, flush type, SP, one way, 5/6 Amps 230/240 Volts, white/ivory finish
Supply and fix Socket outlet 5 pin, 6 Amps, 240 volt flush type complete all as specified and as directed.
Supply and fix Switch socket combination multipurpose 2 in 1, 5 pin 6 Amps 230/240 volt flush type complete all as specified and as directed.
Supply and fix Switch socket combination multipurpose 2 in 1, 6 pin 5 & 15 Amps 230/240 volt flush type complete all as specified and as directed.
Supply and fix Ceiling rose surface bakelite three terminals 240 volts complete all as specified and as directed.
Supply and fixing Lamp holder suitable for batten fittings complete all as specified and directed by the Engr-in-Charge.
Supply and fixing ceiling Fan regulator step type. Solid state 240 Volt complete all as specified and directed by the Engr-in-Charge.
Supply & fix LED lamp of 14/15 watts for energy conversion upto 50% and for efficianteco friendly coollighting and for 30000 maintenance free burning hours including necessary connection all as specified and as directed by Engr-in-Charge. Make:- Havells Cat part No. LHLDDEEEML8R015 or Make:- Surya Cat Part No.14W NEO LED LAMP 6500K,
Supply and fix LED tube light fittings of with LED tube capacity 20W suspended type/ wall mounted type with all fittings and fixtures and necessary connection with copper conductor complete all as specified and as directed . Make:- Bajaj cat Part No. BCLAB 20 W WH LED P or Make:- Crompton cat Part No. LDL-20-CDL or Make:- Havells cat part No. LUMILINEPLUSBS20WLED865SPCSS.
Supply & fix LED Building security light 30 watt in aluminium PDC housing, toughened glass cover with IP66 protection with 0.5 mtr GI pipe of suitable size making connection with PVC cable of 0.50 sq mm three core sheatered not more than 0.5 meter in lenght including taking down old unserviceable recess light fittings complete all as specified and as directed. Make:- HAVELLS Cat part No. ENDURACITYLITEPLATINUMPLUSSL30WLED757SASYBOPC or Make Crompton Cat Part No. LSTS-30-CDL-M or SURYA Cat Part No. SLE UL30W IP66 LXN.
Supply and fix Sheet metal enclosure Metal Door/ Double door for DB's where MCBs to be used 4 way single pole and neutral with 200 amps rated bus bar including taking down old unserviceable DB complete all as specified and as directed. Make:- L&T Cat Part No. DBSPN004DD or Make:- Legrand cat part No.5076 10 or C&S Cat Part No. CSDBSPNPEDD04 . Note:- (1) Quoted rates are inclusive of taking down DB including MCBs. (2) Found Unserviceable MCBs will be contractor property and will be measured under Schedule of Credit.
Supply and fix Sheet metal enclosure Metal Double Door for DB's where MCBs to be used 8 way single pole and neutral with 200 amps rated bus bar including taking down old unserviceable DB complete all as specified and as directed. Make:- L&T Cat Part No. DBSPN008DD or Make:- Legrand cat part No.5076 01 or ABB Cat part No. 1SYI011608C0001 or Make:- C&S Cat part No.CSDBSPNPEDD08. Note:- (1) Quoted rates are inclusive of taking down DB including MCBs. (2) Found Unserviceable MCBs will be contractor property and will be measured under Schedule of Credit.
Supply and fix Sheet metal enclosure Metal Double Door for DB's where MCCBs to be used 8 way TPN with 200 amps rated bus bar including taking down old unserviceable DB complete all as specified and as directed. Make:- L&T/ ABB/ C&S/ Legrand.. Note:- (1) Quoted rates are inclusive of taking down DB including MCBs. (2) Found Unserviceable MCBs will be contractor property and will be measured under Schedule of Credit.
Supply and fix MCB 6 to 32 Amps, SP, 240 Volts , 'C' curve braking capacity 10 kA as directed by the Engr-in-Charge. Make:-L&T Cat part No. BB10060C to BB 10320C or Make:- Legrand cat part 408587 to 408595 or Make:- C&S Cat Part No.CSMBS1C6 to 32 or Make:- ABB Cat Part No. SH201M-C6 to C-32.
Supply and fix MCB 40 Amps, SPN, 240 Volts , 'C' curve braking capacity 10 kA as directed by the Engr-in-Charge. Make:-L&T Cat part No. BB20400C or Make:- Legrand cat part 408618 or Make:- C&S Cat Part No.CSMBS2C40 or Make:- ABB Cat Part No. S201M- C40 NA.
Supply and fix MCCB, 100 Amps, 25kA, four pole, 415 V with thermal and magnetic release, Icu =Ics=100%, IP43, IK-09 adustable type, overload setting 70-100%of input including necessary connection and taking down old unserviceable one complete all as specified and as directed. Make:-L&T/ Legrand/ ABB/ Schneider/ Siemens.
Supply and fix Exhaust fan AC single phase 240 V of size 300mm sweep, 1400 RPM with louver specially designed by Kitchen in domestic ventilation metal body and blade powder coated metallic finish heavy duty motor including taking down old unserviceable exhaust complete all as specified and as directed by engineer-in-Charge. Make:- USHA Cat part no. 300mm S.PH TURBO HDEF 1400 RPM GREY ISI or Make:- Crompton cat Part no. EXHD300-4-1 or make :- Havells cat Part No.TURBO FORCE SP. Note:- Old unserviceable exhaust fan fan shall be deposited to E/M storeyard as directed by Engineer-in-charge.
Supply and fix Ceiling fan AC Single Phase 240 Volts of size 1200mm sweep, metal body and 3 blade, including all fixing arrangements 'S' hook completeall as specified and asd irected. Make:- Usha cat part No. NABILA 1 STAR W/OREG or Make:- Havells cat part No.SS 390 METALLIC or Crompton cat part No.Aura metallic. Note:- Old unserviceable ceiling fan fan shall be deposited to E/M storeyard as directed by Engineer-in-charge.
Materials and labour Earthing complete with galvanised steel earth plate electrode 60 Cm x 60 Cm x 6.00 mm thick buried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI wire 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, GI strip projected by 40 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 Cm c/c both ways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I including taking out of old unserviceable earth pit with all accessories complete all as specified and as directed.
Materials and labour Sub main wiring with 2 runs of single core FR grade PVC insulated unsheathed stranded copper conductor of size 4 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor FR grade of size 2.5 Sqmm as earth lead drawn in and including PVC casing caping of suitable size including all fittings and taking out old unserviceable sub main wring including PVC casing caping complete all as specified and as directed. Note:- Two runs of 4 Sqmm conductor as main wire and one run of 2.5 Sqmm conductor as earth wire with one run of PVC casing caping shall be measured as one unit.
Supply and fix GI pipe, 40mm bore, light grade for protection & passing of LT cable fixed to pole/walls/laid under floor/roads complete including fittings/clamps as required at site all as specified for size of 40mm bore dia all as specified & directed at site including taking out old unserviceable one.
Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 25 Sqmm 4 core in trenches etc including connection complete all as directed by the Engr-in-Charge including taking out old unserviceable cable with unserviceable brick proction.
M/S. CHAKRABORTY ENTERPRISE
M/s Anil Kumar Dutta
PODDAR SALES CORPORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .