| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.7 CrAccepted-AOC K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹14.7 Cr | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹15.1 CrRejected-Finance | ₹15.1 Cr | L2 | Rejected-Finance NOT BEING L1 |
| 3 | L3₹16.0 CrRejected-Finance | ₹16.0 Cr | L3 | Rejected-Finance NOT BEING L1 |
| 4 | L4₹16.6 CrRejected-Finance | ₹16.6 Cr | L4 | Rejected-Finance NOT BEING L1 |
Tender Value
₹14 Cr
EMD Value
₹10.3 L
Closing Date
27 Feb 2023, 6:00 pmClosed
CHIEF ENGINEER CG GOA
CHIEF ENGINEER CG GOA 403806
PROVISION OF DEFICIENT MARRIED ACCOMMODATION AT TRV CHICOLNA GOA
2022_MES_568813_1
82098/E8
Open Tender
Civil Works
720 days
GOA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
GE (I) (CG) GOA
₹10.3 L
Yes
10 Mar 2023
13 Dec 2022
1 Mar 2023
13 Dec 2022
27 Feb 2023
13 Feb 2023
Amount
SCHEDULE ‘A’ PART-I (BUILDING & STRUCTURE WORKS) Details of prepriced schedule is given in tender documents.
SCHEDULE "A" PART-II ( SITE CLEARENCE, DEVELOPMENT AND EARTH WORK EXCAVATION ) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-III (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV (INTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-V (ROAD/CULVERT/ HARDSTANDING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VI (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VII (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VIII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IX (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-X (FIRE FIGHTING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XI (LIGHTNING PROTECTION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XII (LIFTS/ DG SET) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XIII (AIR CONDITION/ CONDUIT FOR TV) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART -XIII (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' E ' signifies this fact only.
INTERNAL WATER SUPPLY S & F Two way bib tap 15 mm complete all as specified and directed. make -Drizzel or Prayag or equivalent
S & F Health faucet with wall hook complete all as specified and directed. Make Hindware model No F160027 or equivalent
INTERNAL ELECTRIC SUPPLY: S & F BEE energy efficient BLDC high-speed ceiling fan having 1200 mm blade sweep, air-flow not less than 210 CMM, operating voltage 220-240 V and frequency 50 Hz, including a down road of suitable size and electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fan complete all as specified and directed.
S & F energy efficient non-metallic fresh air fan having blade sweep 250 mm, air delivery not less than 860 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed. Make: Crompton Cat-Part No. VENTILUS 10" or equivalent model of Usha, Havells or BAJAJ
S&F engery efficient metalic exhaust fan having blade sweep 300 mm, air delivery not less than 900 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed. Make: Crompton Cat-Part No.TRANS AIR 12" or equivalent model of Usha, Havells or BAJAJ
S & F RCBO conforming to IS 12640 (Part 2): 2016, assembled for AC applications having front face indication for earth leakage fault, sliding shutters, IP 20 protected 35 mm² terminals, colour coded on/off indication on dolly, integrated label holder, etc complete all as specified and directed. 63 A, 100 mA, FP 415V, 50 Hz RCBO
Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor cubical compartmental type LT panel of suitable size, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides open able with hinged double doors and locking arrangement, IP 43 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete all as specified and directed by engineer-in-charge.(Building supply at Ground floor) The Panel shall comprise of the following: [A] BUSBAR CHAMBER [I] 01 Set (3L + N) of copper busbar of rated capacity 400 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING [I] 250 A, 415 V, Ices = 100% Ice = 50 kA, 50 Hz FP MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ire), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and pre-alarm & Overload), etc.
[ii] LED phase indicators (Red, Yellow, Blue)- 01 Set [iii] Digital Multifunction meter with KWH and Karsh, Voltage, current, PF functions [C] OUTGOING [i] 63 A, 415 V, Ices = 100% Ice = 50 kA, 50 Hz FP MCCB, conforming to IEC 60947-2, Qty 11 Nos [ii] 20 A, 230 V, 50 Hz SPN MCB, conforming to IEC 60947-2, Qty 1 Nos (for Lift room) [ii] 6 A, 230 V, 50 Hz SP MCB, conforming to IEC 60947-2, Qty 2 Nos (for common light points)
Supply, Installation, Testing and Commissioning of 1-Phase, 2-wire, 240V, Class 1.0 Smart Energy Meter, BIS marked IS-16444, at the rating of 5-30A suitable for Prepaid/Postpaid mode with Polycarbonate Meter Box. The Smart Meter shall support the following minimum basic features: Measurement of electrical energy parameters; Bidirectional Communication; Integrated Load limiting /connect/disconnect switch; Tamper event detection; recording and reporting; Power event alarms; Remote firmware upgrade; TOD features; On demand reading. Meter shall have the ability to communicate with Head End System (HES) on RF Communication technology mentioned in IS16444 Part 1 in a secure manner. Data exchange protocol from smart meter to HES shall be based on open protocol like TCP/lP or DLMS/COSEM. RF network should use 865-867 MHz frequency band as permitted by WPC.
Supply, installing, testing & commissioning of Cloud-Hosted multiuser web-based software with 2-years defect-liability period with following modules: (i) Head End System (HES): to acquire meter data automatically from DCUs and monitor parameters acquired from meters. (ii) Meter data management Modules : The meter data management module would be responsible for collecting the data from the concentrator and make the data available to the billing system. The meter data management system would capture and provide the following data. (a) 30min instantaneous data from all the meters for seven parameters - cumulative energy , Power, Current , Voltage, Power factor and frequency. (b) Monthly and quarterly billing survey data for cumulative energy and max demand. (iii) Billing Module : The billing module would collect the data from the meter data management module, calculate billing determinant and make energy data / billing data available to admin and end user. There should be provision for entry of change in the tariff structure by the MES staff as decided time to time. (iv) Occupation and Vacation module: The system would supportoccupation/vacation based on the unit categories. (v) Website: There would be a dedicated website for AGE/GE and BSO team to view all the data and information along with customer portal for use of customer. The designated users in MES would have the admin access to the application. The MES Staff would also have the access to the key information on mobile App (Androi and iOS based) for admin use. (vi) Customer Module : The system would include a customer portal for the resident/occupants to log in and view their own energy/billing data and recharge facility. There shall be consumer App (Android and iOS based) also to log in and view their own energy/billing data and recharge facility.
Supply, Installation, Testing and Commissioning of DCUs/Gateways and the arrangement of Sim cards or Internet to enable reliable medium for two-way communication between Smart Meter & HES. The data acquisition (Push/Pull) frequency shall be configurable. It shall push events such as tamper, power off etc. to HES immediately on occurrence/receipt from meters. It shall have provision for the cellular, WiFi and Ethernet communication for the backhaul to HES. It shall be capable to handle data of minimum 1000 Nos. of any type of smart meter (1ph/3ph). It shall be able to communicate with the nearest meters at a distance of at least 500 m, depending on topographical features. Communication of the nearest meters with other meters shall be established through appropriate mesh formation. RF Mesh shall support self-forming and self-healing features. The equipment shall be weather proof and dust proof (minimum rating: IP54 for indoor and IP65 for outdoor installation). It shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc.
External Water Supply: Supply, installation, testing and commissioning pumping , centrifugal monoblock electric driven, 3 phase, 415 volts, (400 LPM at 50M head) including necessary PCC foundation and inlet & out water supply connection including provision of brass gate valve for inlet and outlet connection complete all as specified & directed.
Cutting the existing DI pipe of 150 mm dia and reducing to required length in position for inserting new Tees, branches etc. complete all as specified & directed.
Supply and lay pipe DI , S/S including specials, Class K-7, 100 mm (4") dia. all as specified & directed.
Supply and fix Foot Valve conforming to IS 4038, 80 mm dia all as specified & directed.
Supply and fix Strainer Y type conforming to IS, size 80mm dia. all as specified & directed.
Supply and fix Valve reflux with by-pass Arrangement, 80 mm (3”) dia all as specified & directed.
M & L for Valve chambers suitable upto 150 mm dia bore valves of size 90 cm x 90 cm x 90 cm complete with M S cover all as specified & directed.
External Electric Supply: Supply and fix MCCB with sheet metal enclossure capacity 250 A, 36KA, 4 pole all as specified & directed.
Supply install test and commission LT Panel board, TPN 415 Volts, 50 Hz, 300 Amps capacity, outdoor cubical type floor mounted factory made double door dust and vermin froof fabricated out of CRCA sheet not less than 3.15 mm thick fixed on angle iron frame made out of 50x50x6 mm with cable chamber for individual feeders for incomming and outgoing connections, one set of indicator lamp RYB with switch and fuse, multifunction intelligent panel meter etc and with the followings (Main Bldg panel ) INCOMING:- (a) Multifunction panel meter with CTs (b) MCCB with microprocessor based release, 4 pole, 200 AMPS, 50 Hz, 415 Volt, 35 KA - 1 No (Incoming) OUTGOINGS:- (a) MCCB, 4 pole, 160 Amps, 50 Hz, 415 Volts, 35 KA -01 Nos (For Bldg) (b) MCCB, 4 pole, 63 Amps, 50 Hz, 415 Volts, 35 KA -01 Nos (for DG Panel )
Supply install test and commission LT Panel board, TPN 415 Volts, 50 Hz, 200 Amps capacity, oudoor cubical type floor mounted factory made double door dust and vermin froof fabricated out of CRCA sheet not less than 3.15 mm thick fixed on angle iron frame made out of 50x50x6 mm with cable chamber for individual feeders for incomming and outgoing connections, one set of indicator lamp RYB with switch and fuse, multifunction intelligent panel meter etc and with the followings :- (DG Panel) INCOMING:- (a) MCCB with microprocessor based release, 4 pole, 63 AMPS, 50 Hz, 415 Volt, 35 KA - 1 No (Incoming) OUTGOINGS:- (a) MCCB, 4 pole, 32 Amps, 50 Hz, 415 Volts, 16 KA -01 Nos (for lift) (b) MCB, 4 pole, 16 Amps, 50 Hz, 415 Volts, 16 KA -01 Nos (Domestic P/H ) (c) MCB 3 pole, 10 Amps, 50 Hz, 415 Volts, 16 KA -02 Nos (Street& Security lights) (d) Contactor 3 Pole 9 Amps (AC3 rating) type MX 9 of L& T cat Part No CS94015-1 No (e) Analog Time switch for 24 Hrs setting 1 phase, 15 Amps of L&T cat Part No AUTS01ANA00 - 01 No
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 4 sq mm, 3 core, 1100 Volts grade complete all as specified and directed
Supply and fix Prestressed concrete poles of 9 meter long having 152 mm x 152 mm at top and 152 mm x 260 mm at bottom, including excavation, foundation and coping complete all as specified and directed
Supply and fix Hot press moulded SMC boxes with one No MCB SP 6 Amps, connector 4 way 16 Amps including fixing clamps, nut bolts etc complete as street light terminal boxes all as specified and directed
Supply and fix aviation obstruction light all as specified and directed
Supply and lay PVC insulated PVC sheathed electric control cable with stranded copper conductor of size 1.5 sqmm 2 core 1100 volts grade all as specified and directed
FIRE FIGHTING: Supply and lay control cable PVC insulated PVC sheathed galvanised steel strip or wire armoured with stranded copper conductor of size 1.5 sqmm 2 core 1100 Volts grade all as specified and directed
DG SET: Supply and installation of silent Diesel Engine driven generating set 415 volts, 3phase 4 wire, engine as per IS:10001/ 10002 and Alternator as per IS: 13364 complete with relay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms and foundation etc. of as per CPCB norms and foundation etc. of as per CPCB norms and foundation etc. of capacity 30 KVA
CONDUIT FOR TV: S&F TV socket with metal box and top plate complete as specified & directed
NITYA NAND AND SONS CONTRACTORS PVT LTD
S.N. Constructions
Kanika Construction Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid