| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.2 LAccepted-AOC DOCTORS COLONY ROAD NAYAGAON SHADIPUR POST PORT BLAIR 744 106 A N ISLANDS | PORT BLAIR | SOUTH ANDAMANS | A N ISLANDS | 744106 | L1 | Accepted-AOC L1 | |
| 2 | L2₹56.5 L+₹5.7 L (11.2%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹57.3 L+₹6.5 L (12.9%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹58.7 L+₹8.0 L (15.7%)Rejected-Finance NEAR SATSANG GARACHARMA BASTI GARACHARMA PORT BLAIR 744 105 | PORT BLAIR | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744105 | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹59.7 L+₹8.9 L (17.6%)Rejected-Finance 365 B 10 HENRY COMPLEX MATHIYAS NAGAR KP ROAD NAGERCOIL KANNIYAKUMARI DISTRICT 629001 | KANNIYAKUMARI | TAMIL NADU | 629001 | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
17 Feb 2023, 6:00 pmClosed
GE Minniebay
GE Minniebay Junglighat Post Minniebay Port Blair 744103
REPAIR MAINT AND REPLACEMENT OF LT UG CABLES INCLUDING CABLE LUGS GLANDS ETC AND REPAIR/MAINT OF FIRE FIGHTING SYSTEMS,INCINERATOR, CRANE AND OTHER CONNECTED WORKS UNDER AGE EM-I AT GE MINNIE BAY PORT BLAIR
2023_MES_576345_1
8220/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Minniebay Port Blair
As per tender documents
11 documents required · 11 mandatory
₹500
GE MINNIEBAY
₹98,000
Yes
4 Mar 2023
21 Jan 2023
20 Feb 2023
21 Jan 2023
17 Feb 2023
4 Feb 2023
Amount
Taking down of unserviceable old UG Cable of any size and any type complete all as specified and directed by Engineer-in-Charge.
Suppy and laying in trenches, fixed on walls, passing through pipes, jointing and testing of electric LT cables, PVC insulated, PVC sheathed, galvanised steel strip or wire armoured electric power cables with stranded aluminium conductors 1100 Volts grade complete all as specified and as directed by Engineer-in-Charge for the following size :- Note: (i)The quoted rate shall deemed to include cost of Cable lugs, Cable Gland and jointing kit (if required) (ii)The earthwork required shall be measured and paid separately.
4 Core 10 Sqmm
4 Core 16 Sqmm
3.5 Core 25 Sqmm
3.5 Core 35 Sqmm
3.5 Core 50 Sqmm
3.5 Core 70 Sqmm
3.5 Core 95 Sqmm
3.5 Core 120 Sqmm
3.5 Core 185 Sqmm
3.5 Core 240 Sqmm
3.5 Core 300 Sqmm
3.5 Core 400 Sqmm
Relaying of serviceable cable of XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with stranded aluminum conductor 1100 volts grade, laid in trenches / duct with shaddling / on pole including all necessary fixing arrangement such as lugs, glands end termination etc of size 10 Sqmm to 35 Sq mm Core complete all as specified and as directed by Engineer-in-Charge. Note: The earthwork required shall be measured and paid separately.
Relaying of serviciable cable of XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with stranded aluminum conductor 1100 volts grade, laid in trenches / duct with shaddling / on pole including all necessary fixing arrangement such as lugs, glands end termination etc of size 50 Sqmm 3.5 to 95 Sq mm 3.5 Core core complete all as specified and as directed by Engineer-in-Charge. Note: The earthwork required shall be measured and paid separately.
Relaying of serviciable cable of XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with stranded aluminum conductor 1100 volts grade, laid in trenches / duct with shaddling / on pole including all necessary fixing arrangement such as lugs, glands end termination etc of size 120 Sqmm 3.5 Core to 240 Sq mm 3.5 Core complete all as specified and as directed by Engineer-in-Charge. Note: The earthwork required shall be measured and paid separately.
Relaying of serviciable cable of XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with stranded aluminum conductor 1100 volts grade, laid in trenches / duct with shaddling / on pole including all necessary fixing arrangement such as lugs, glands end termination etc of size 300 Sqmm 3.5 Core to 400 Sq mm 3.5 Core complete all as specified and as directed by Engineer-in-Charge. Note: The earthwork required shall be measured and paid separately.
Taking down of unserviciable old DWC HDPE Pipe of any size and any type complete all as specified and as directed by Engineer-in-Charge
Supply & Laying of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm polythylene including coupler & Bend with smoooth internal and profiled external surface for non pressue under ground cable complete all as specified and as directed by Engineer-in-Charge
Supply & Laying of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 63 mm and inner dia 50 mm polythylene including coupler & Bend with smoooth internal and profiled external surface for non pressue under ground cable complete all as specified and as directed by Engineer-in-Charge .
Supply & Laying of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 77 mm and inner dia 63 mm polythylene including coupler & Bend with smoooth internal and profiled external surface for non pressue under ground cable complete all as specified and as directed by Engineer-in-Charge.
Supply & Laying of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 120 mm and inner dia 103 mm polythylene including coupler & Bend with smoooth internal and profiled external surface for non pressue under ground cable complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair GI pipe of 40 mm dia medium grade ISI marked including all fitting fixture for fixing on wall or laid in road crossing etc complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair GI pipe of 50 mm dia medium grade ISI marked including all fitting fixture for fixing on wall or laid in road crossing etc complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair GI pipe of 80 mm dia medium grade ISI marked including all fitting fixture for fixing on wall or laid in road crossing etc complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches in soft/loose soil not exc 1.5 m wide and not exc 1.5 m in depth for foundation, pipe, laying of cable etc not exc 10 Sqm on plan and not exc 1.5 m in depth and getting out complete all as specified and as directed by Engineer-in-Charge
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil all as specified and as directed by Engineer-in -charge.
Removing excavated materials (soil) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 meters above the starting point all as specified and as directed by Engineer-in -charge.
M&L for road /hard standing including cutting, removing of material , returning filling and providing Plain cement concrete 1:2:4 Nominal mix for laying of LT UG cable /Galvanised Iron Pipe/Rex Pipe all as specified and as directed by Engineer-in -charge.
M&L for Fault finding of LT UG Cable including excavation , returning refilling after rectification of fault with fixing of Straight through joint kit, extra UG Cable and DWC (Double Wall corrugated) HDPE pipe complete all as specified and as directed by Engineer-in -charge. Note:- LT UG Cable, Straight through joint kit and DWC (Double Wall corrugated) HDPE pipe measured and paid separately under relevant items.
Supply and fixing as in repair of cable jointing kit for 1100Volt grade cable for Straight through, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 10 to 16 Sqmm 3.5 core as in repairs complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of cable jointing kit for 1100Volt grade cable for Straight through, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 25 to 50 Sqmm 3.5 core as in repairs complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of cable jointing kit for 1100Volt grade cable for Straight through, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 70 to 150 Sqmm 3.5 core as in repairs complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of cable jointing kit for 1100Volt grade cable for Straight through, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 185 to 240 Sqmm 3.5 Core as in repairs complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of cable jointing kit for 1100Volt grade cable for Straight through, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 300 to 400 Sqmm 3.5 Core as in repairs complete all as specified and as directed by Engineer-in -charge.
M&L for rerouting/ Dicipline the serviceable Power Cable on wall /cable duct of size 16 to 50 Sqmm with saddling with aluminium pati with requard size of screw inside cable duct complete all as directed.
M&L for rerouting/ Dicipline the serviceable Power Cable on wall /cable duct of size 70 to 185 Sqmm with saddling with aluminium pati with requard size of screw inside cable duct complete all as directed.
Supply and fixing in repair aluminium cable lugs for fixing of armoured cables in panels complete all as specified and as directed by Engineer-in-Charge for the following sizes of cables complete all as specified and directed by Engineer-in-Charge. :- Note : Necessary earthwork shall be measured and paid separately
Supply and fixing in repair of Copper cable lugs for fixing of armoured cables in panels complete all as specified and as directed by Engineer-in-Charge and for the following sizes of cables :-
Supply and fixing as in repair of Cable gland of LT UG cables in panels for complete all as specified and as directed by Engineer-in-Charge and the following sizes of LT UG cables :-
M& L for preparation to internal and external old steel surface of LT Feeder Pillar Box/ Panel Box of various size and completely removal of existing treatment by scraping or chemical removal and painting the surface with DUCO paint with help of spray gun over a coat of red oxide primer complete all as specified and as directed by Engineer-in-Charge.
M& L for repair of fabrication for LT Feeder Pillar Box/ Panel Box made out of 2.00 mm thick mild steel sheet fixed to existing frame and painting with DUCO paint with help of spray gun over a coat of red oxide primer including taking out to existing worned out shutter/frame and fixing with minimum two hinges to existing frame complete all as specified and directed.
M& L for repair of fabrication for LT Feeder Pillar Box/ Panel Box made out of 3.00 mm thick mild steel sheet fixed to existing frame and painting with DUCO paint with help of spray gun over a coat of red oxide primer including taking out to existing worned out shutter/frame and fixing with minimum two hinges to existing frame complete all as specified and directed.
Supply and fixing as in repair of alluminium tower bolts, 300mm long bright bolt including connected accessories fixed on front and rear side of the doors for locking LT FP Boxes complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of doors hinges of LT feeder pillar/Panel box complete with welding complete all as specified and as directed by Engineer-in-Charge.
Taking down of PCC any grade complete all as specified and as directed by Engineer-in-Charge.
M&L Plain cement concrete (1:2:4) Nominal mix B1 grade using 20 mm aggregate in foundations filling and mass concrete complete all as specified and as directed by Engineer-in-Charge.
Material and labour Plain Cement Concrete (1:3:6) type C-2 (using 40 mm graded broken stone aggregate) as in coping/collar of poles including necessary form work complete all as specified and as directed by Engineer-in-Charge.
Taking down of MCCB of any size complete all as specified and as directed by Engineer-in-Charge.
Supply and fix MCCB 400 Amps,TPN/ 4 pole, 415 volt, breaking capacity 36 KA conforming to IS 13647-II: complete all as specified and as directed by Engineer-in-Charge.
Supply and fix MCCB 250Amps,TPN/ 4 pole, 415 volt, breaking capacity 25 KA conforming to IS 13647-II: complete all as specified and as directed by Engineer-in-Charge.
Supply and fix MCCB 200Amps,TPN/ 4 pole, 415 volt, breaking capacity 25 KA conforming to IS 13647-II: all as specified
Supply and fix MCCB 160 Amps, TPN/4 pole, 415 volt, breaking capacity 16 KA conforming to IS 13647-II: complete all as specified and as directed by Engineer-in-Charge.
Supply and fix MCCB 100 Amps, TPN/4 pole, 415 volt, breaking capacity 16 KA conforming to IS 13647-II: complete all as specified and as directed by Engineer-in-Charge.
Supply and fix MCCB 63 Amps, TPN/4 pole, 415 volt, breaking capacity 16 KA conforming to IS 13647-II: complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of on load change over switch 4 pole 630 Amps in sheet metal enclosure complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of on load change over switch 4 pole 400 Amps in sheet metal enclosure complete all as specified and as directed by Engineer-in-Charge.
Taking Down of Old rusted feeder pillar Box complete all as specified and as directed by Engineer-in-Charge.
Supply, installation, testing and commissioning LT panel board double door of suitable size for 3 phase 415 Volts of CPRI approved of suitable size bus bar of rating 800 Amps out door made out of 3.15mm thick CRCA sheet with angle iron frame of size 50X50X 6mm cubical type including suitable size of panel stand made out of angle iron size 50X50X 6mm of complete including PCC foundation as per site requirment to accomodated to the following:- INCOMING (a) MCCB 4 pole 250 Amps 25 kA (c) On Load Change over of capacity 250 Amp -01 No (b) Digital Ammeter with CT's (0-400) - 01 No (c) Digital Volt meter 0-500 Volt - 01 No (d) LED indicating lamp (R-Y-B) - 03 Nos OUTGOING (a) MCCB 4 pole 100 Amps 16 kA- 03 Nos (b) MCCB 4 pole 63 Amp 16 KA - 02 Nos Note :- 1. Make of MCCB Legrand DPX 3 / Schenider -NSX / L&T- Dsine . 2.MCCB should be ICU = 100 % ICU . 3. MCCB should be adjustable O/L0.8-1 and S/C - 5-10 ln. 4. Bus Bar Make Should be Hindalco Alumina.
Supply and fixing as in repair of MFM meter (V,A,PF, W) with CTs including necessary fabrication requaired and painting the effected area with existing paint complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair of IP 66 thermoplastic-polycarbonate cable junction box of size 205X255X112 with terminal which is totally shock proof, water proof, halogen free, silica and having internally embedded gasket technology fixing on pole / surface / frame with the help of GI calmp of required size / self drill screw ,one no of MCB SP 6 Amp and four way Connector complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of IP 66 thermoplastic-polycarbonate cable junction box of size 155X210X92 with terminal suitable for 10 to 16 Sqmm ,which is totally shock proof, water proof, halogen free, silica and having internally embedded gasket technology fixing on pole / surface / frame with the help of required size / self drill screw and four way 32 Amp Connector complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of IP 66/ 67 thermoplastic-polycarbonate cable junction box of size 130X180X77 with terminal suitable for 4 to 10 Sqmm which is totally shock proof, water proof, halogen free, silica and having internally embedded gasket technology fixing on pole / surface / frame with the help of required size / self drill screw with four wa Connector complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of Earthing complete with copper earth plate electrode 60 cm x 60 cm x 3 mm thick, buried directly in ground earth pit not less than 2.25 metre below normal groud level with top edge of the plate not less than 1.5 mtr below ground level, connected to and including copper earth strip 25 x 3.00 mm by means of copper brazing and steel bolts, nuts, check nuts and washers protected with 40mm bore GI pipe light grade and 15 mm dia GI pipe for watering and earth pit surrounded by picked layer of coal and common salt, 15cm thick all around bottom and top, watering pipe of 20 mm bore of light grade with funnel all as shown in electrical plate No 3 of SSR Part-I (2009) and connecting to earthing test point, main switch board and testing on completion including PCC (1:3:6) type C-2, using 20mm graded stone aggregate as in earthing pit with RCC cover and framing including necessary earth work etc, complete all as specified and as directed by Engineer-in -charge. Note: (i) Cost of Copper earth Strip and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item.(ii) The unit rate shall also includes for Wire mesh, funnel, excavation.returninng & filling. PCC chamber pit,RCC cover & test point.(iii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit. (iv) All accessories required for galvanised steel plate electrode required , as specified and as directed by Engineer in charge as per
Material and labour as in repair for Earth pit indicator for existing earthing pit made out of 16 mm dia and 60 cm long MS Squre Bar embeded in PCC (1:3:6) type C-1 using 20 mm graded stone agreegate in PCC block of size 30 X30 X30 cm including CI/MS plate of size 25X30X 3 mm thick fixed on side of earth pit cover complete painting and writing over the plate ie. Type , Result, Date of measurement and pit number with Black beground with white and complete all as specified and as directed by Engineer-in -charge.
Taking down Earth pit cover of conventional earthing and S&F PCC earthing pit of outer size 450X450 X300 MM and inner Size 350X350X 300 RCC pit cover of required size with handle arrangement including necessary earth work complete all as specified and as directed by Engineer-in -charge.
Material and labour Painting to Steel tublar / RCC poles 9 m long with one coat of Synthetic enamel paint black/yellow combination Zebra marking up to 1 m from ground level / coping remaining portion painting with one coat of aluminium paint including preparation of old painted surfaces and painting the pole terminal etc.complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of GI tubular swaged poles complete with GI base plate finial taper plug, bolts, nuts and screws,with two holes for drawing conductor between pole box to street light fitting all as specified type 410 SP-31 of height 9m including necessary Earth work,PCC foundation copping etc and refixing of all existing fitting fixture exist in old electric pole complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of 2.5 Sq.mm (nominal area) PVC unsheathed multi strandard copper conductor PVC insulated 1100 volt FRLSH grade twin core cable drawn through CPVC Pipe not less than 20 mm dia for connecting the street light fittings including alluminium clamp complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of GI bracket for street lights made out of medium grade GI pipe 40mm dia, 1.2m long bend to shape as directed, fixed on poles with two Nos GI clamp of size 40 x 6mm flat iron suitable for steel tubular pole including suitable GI nuts and bolts washers complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of energy efficient street light luminaire LED type 70 watts,IP66 ,230volts, 50 Hz , in Deepdrawn aluminium housing and cast aluminium pipe mounting attachment including suitable heavy duty electronic driver also driver should withstand 265 volts,and complete accessories, pre-wired and connection complete with suitable size of stranded copper flexible conductor complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of energy efficient solar street light all in one with lithium battery LED type of 30 watts,IP65 in built motion sensor colour temp 6500 complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of Service wire and supply and fixing submersible wire copper Conductor Weather Proof 6 Sqmm three core complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of submersible wire copper Conductor Weather Proof 10 Sqmm three core complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of service wire aluminium conductor Weather Proof 10 Sqmm three core complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair for fabrication ,Installation testing and commissioning of LED sign board depth 250 mm in 3D acrylic letters made of high quality cast acrylic with LED , water proof conforming to IP 66 and fixed with organization logo and including all necessary fitting fixture fixing on wall complete all as directed . Note:- (i) Rates are inclusive of fixing on wall / pole ,Necessary LED and electrical connection required for commissioning. (ii) Contents to be written on board and size of board shall be provided by Engr-in-charge.
Supply and fixing as in repair for fabrication ,Installation testing and commissioning of LED sign board depth 250 mm with flex print water proof conforming to IP 66 and fixed with organization logo and including all necessary fitting fixture fixing on wall complete all as directed . Note:- (i) Rates are inclusive of fixing on wall / pole ,necessary LED light and electrical connection required for commissioning. (ii) Contents to be written on board and size of board shall be provide by Engr-in-charge.
Supply and fixing as in repair rubber insulation tape high voltage type of size 25 Cm width 2.5 Mtr long fixing of connection make water proof outside the Electrical equipments and also fixing the underground cable where crack arises outside complete all as specified and as directed by Engineer-in -charge.
Supply and fix as in repair outdoor gate/post light E27 Holder type with LED bulb of 12 watt made in cast aluminium spigot housing with decorative clear opal acrylic diffuser and IP 54 protection complete all as specified and as directed by Engineer-in -charge.
Supply and laying broken stone or Boulders filling of Gauge not exc. 63 mm, deposited, spread and levelled in layers not exc. 150mm thick, watered and rammed to a true Surface, complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of cross arms, bracing, supports, clamps and back plate fabricated from structural MS section for gate including nuts, bolts, washers, welding, bending, cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of Danger notice plate of PVC sheet, enamelled white, with letters, figures ( English, Hindhi,Tamil) and conventional skull and bones in signal red colour and fixed with Alluminium Clamp. clamps, bolts and nuts of approved size, for HT of voltage 11000 Volts, 25x20cm size complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of Danger notice plate of PVC sheet, vitreous enamelled white, with letters, figures ( English, Hindhi,Tamil) and conventional skull and bones in signal red colour and fixed with Alluminium clamps, bolts and nuts of approved size, for HT of voltage 11000 Volts, 25x20cm size complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of earthing with galvanised earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to galvanised iron strip 32 mm x 6 mm by means of GI Welding made out of galvanised iron mild steel and 40 mm dia GI pipe "light grade" for protection of earth lead and connected to control board or transformer neutral earth or as directed including earthing pit in PCC (1:3:6) type C-1, pre-cast reinforced cover with 8 mm dia reinforced cover slab of size 450 x 450 x 100 mm with one handle made out of 8 mm dia round bar 20 mm dia GI pipe light grade for watering funnels , wire mesh and provided charcoal or coke of alternative layers of 15 cm including necessary earth work complete shown in electrical plated No 3 and testing complete all as specified and as directed by Engineer-in -charge. NOTE : (i) The earthing pit should be provided with proper earth pit and pit cover. Pit cover should be painted with synthetic enamel paint of approved colour (ii) If the desired earth registance is not achive during testing as per IS the complete earthing shall be carried out by the contractor at his own cost and no extra claim shall be admissable.
Supply and fixing in repair for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 25 mm x 3 mm thick, copper strip using porcelain clit/post insulators, complete all as specified and as directed by Engineer-in -charge.
Material and Labour for Servicing to UPS of capacity 5 KVA single phase 230 V of any Make by dismantling and checking the following and replacement of unserviceable parts/ spares complete all as specified and as directed by Engineer-in -charge. :- (a) Checking of SMPS (b) Fuse AC/DC (c) Current Transformer (d) Specific gravity test of batteries. (e) Input and output voltage test. (f) Mother board
Material and Labour for Servicing to UPS of capacity 40 KVA single phase 230 V of any Make by dismantling and checking the following and replacement of unserviceable parts/ spares complete all as specified and as directed by Engineer-in -charge.:- (a) Checking of SMPS (b) Fuse AC/DC (c) Current Transformer (d) Specific gravity test of batteries. (e) Input and output voltage test (f) Mother board
Supply and fixing as in repair of GI earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 32 mm x 6mm thick, Galvanised using porcelain clit/post insulators, complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of Alluminium earth continuity conductor or main earthing lead fixed to wall above 11 mtr or rooftop of 3 rd floor or recess or any other indicated situation for loop earthing etc. as required for 25 mm x 3mm thick, alluminium using porcelain clit/post insulators, complete all as specified and as directed by Engineer-in -charge. Note:-Necessary scaffolding and safety precaution shall be provided by contractor and rate quoted shall deemed to cost of the same.
M&L for Welding of two MS/GI Sheet / Pipes on site including grinding the welded portion and made smooth surface complete all as specified and as directed by Engineer-in -charge.
Supply and fixing as in repair of MCB 63 Amps, TPN/4 pole, 415 volt, breaking capacity 10 KA complete all as specified and as directed by Engineer-in-Charge.
Taking down of old MCB 100 Amp TPN and Supply and fix MCB 100 Amps, TPN/4 pole, 415 volt, breaking capacity 10 KA complete all as specified and as directed by Engineer-in-Charge.
M&L for Cutting vegetation and surface dressing not exceeding 15 cm deep including removing the materials to a distance not-exc 60 mtr complete all as specified and directed by Engineer-in -charge.
Supply and fixing as in repair of Aluminium Bus Bar of existing Size in the existing panel board on site on required shape post insulators, complete all as specified and as directed by Engineer-in -charge.
Supply and fixing in repair LED Indicating lamp (R-Y-B) complete all as specified and as directed by Engineer-in -charge.
Material and labour for repairs/ servicing to fire fighting pump motor and checking for running of firefighting system, preparation/cleaning of outer surface by scrapping with emery paper or other means and painting of fire fighting pump motor of various capacity with two coats of synthetic enamel paint (red colour) complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair of MS pipe ERW Heavy (IS1239) errect, jointing complete of 80 mm dia with necessary supports and specials such as tees, bends, reducers etc including consumables and painting with one coat of red oxide primer and two coats of synthetic enamel paint including making the disturbed surfaces good of wall/ ceiling etc and taking down old unserviceable MS pipe complete all as specified and as directed by Engineer-in-Charge.
All as per item srl No 88 here-in-before but of 50 mm dia complete all as specified and as directed by Engineer-in-Charge.
All as per item srl No 88 here-in-before but of 25 mm dia complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair Sprinkler glass bulb type (Standard response) as per IS:15106/TAC guidelines 68 degree temperature rating pendent type including taking down unserviceable sprinkler complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair Sprinkler glass bulb type (Standard response) as per IS:15106/TAC guidelines 68 degree temperature rating concealed type including taking down unserviceable sprinkler complete all as specified and as directed by Engineer-in-Charge.
Supply and fix as in repair Addressable manual call point resettable type with suitable clamp and wire including taking down unserviceable manual call point complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair Fire Alarm Sounders / Sirens Electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of +5 DB 500m range complete all as specified and as directed by Engineer-in-Charge.
Cleaning of semi underground sump of capacity 1.5 lakh liter through following steps:- (a) The inner surface of the walls of the tank shall be cleaned with wire brush after emptying the water in the tank.b) After thorough cleaning of the tank, the cleaning water and sludge is to be removed by using pump and the sludge has to be disposed off at a place as directed.c) After removing the sludge from tank, the tank shall be cleaned with anti bacterial agents.d) After complete treatment, writing of "Tank capacity,Date of cleaning and Due date of cleaning" on wall including applying two coats of white/colour wash to external surfaces complete all as specified and as directed by Engineer-in-Charge.
All as per item No 95 above here-in-before but of semi underground sump capacity 75000 liters complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair butterfly valve ISI marked with CI body of size 100 mm dia with suitable gasket, nut & bolts including necessary welding works as required and taking down unserviceable butterfly valve complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair butterfly valve ISI marked with CI body of size 150 mm dia with suitable gaskit, nut & bolts including necessary welding works as required and taking down unserviceable butterfly valve complete all as specified and as directed by Engineer-in-Charge.
S&F as in repair butterfly valve ISI marked with CI body of size 80 mm dia with suitable gaskit, nut & bolts including necessary welding works as required and taking down unserviceable butterfly valve complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing sluice valve ISI marked short body type of cast iron both ends flanged with rubber insertion and drilled of size 100 mm dia and IS 14846 with pressure rating of PN 1.6 with brass/copper alloy spindle and iron wheel head with nuts, bolts and washers of suitable size including taking down old unserviceable sluice valve complete all as specified and as directed by Engineer-in-Charge.
All as per item No 100 here-in-before but of 80 mm dia complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing cast Iron Non return valve ISI marked, short body type, flanged ends heavy duty as per IS 5312, PN 1.6 of size 100 mm dia including 6mm thick rubber insertion ring and taking down old unserviceable non return valve complete all as specified and as directed by Engineer-in-Charge.
All as per srl item No 102 here-in-before but of 80 mm dia complete all as specified and as directed by Engineer-in-Charge.
M & L for yard hydrant post 80 mm dia MS of flange type including taking down unserviceable hydrant post complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing fire hydrant valve, single headed including required washer and fittings complete and taking down unserviceable fire hydrant valve complete all as specified and as directed by Engineer-in-Charge.
Supply and fix C P Hose of 15 m length including taking down unserviceable C P Hose complete all as specified and as directed by Engineer-in-Charge.
Supply and fix branch pipe gun metal 63 mm inlet made threaded outlet 15 mm bore nozzle short including taking down unserviceable branch pipe complete all as specified and as directed by Engineer-in-Charge.
M & L for hose box of any description and providing new hose box made of 18 gauge MS sheet 800x600x250mm with double door with 4mm thick glass and door frame made of 16 gauge MS sheet painted fire red outside and brilliant white inside yard including taking down unserviceable hose box complete all as specified and as directed by Engineer-in-Charge.
Supply and fix Hose reel Drum including 30 m long and 20 mm dia high pressure hose reel and taking down unserviceable hose reel drum complete all as specified and as directed by Engineer-in-Charge.
Supply and fix as in repair of tranparent Ancillary sheet for Hose reel Drum and hose box including taking down unserviceable tranparent Ancillary sheet complete all as specified and as directed by Engineer-in-Charge.
M&L as in repair block masonry work in valve chamber or support base or straight or curved on plan with standard PCC blocks in cement mortar 1:6 complete all as specified and as directed by Engineer-in-Charge.
Material & Labour for servicing overhauling of incinerator & making incinerator hydraulic system complete operational with replacement of limit switch, solenoid switch, replacement of oil,unserviceable pipe, pressure gauge and complete servicing of incinerator hydraulic system and making in running condition including testing and commissioning complete to the entire satisfication of Engineer-in-Charge. Make : HATT.
Material & Labour in repair of inside fire chamber with fire bricks and gypsum of side wall and roof of the primary and secondary chamber including testing and commissioning complete as as specified and directed.
M& L for preparation to external surface of chimney and incinerator body and completely removal of existing paint by scraping or chemical and surface painted with heat resistance synthetic enamel paint with help of brush complete all as specified and as directed by Engineer-in-Charge. Note :- (i) Scaffolding and other safety precaution will be arranged by the contractor and the cost for the same shall be deemed to be included in the quoted rate.
Material and labour for cleaning of chimney of incinerator from chamber to upto 10 m height and removing all dirt, particles from inside and refixing with gland, nuts and bolts and cleaning of mild steel water tank and removing all particles from tanks and replacement of GI Pipe connected from chimney to water pump including valves and other accessories complete all as specified and as directed.
Supply and fix in repair Nozzle assembly including taking down unserviceable nozzle assembly complete all as specified and as directed by Engineer-in-Charge. (Cat Part No. 115117243)
Supply and fix in repair Photocell Light detector including taking down unserviceable photocell light detector complete all as specified and as directed by Engineer-in-Charge. (Cat Part No. 91740907)
Supply and fix in repair Fuel pump BFP 41L3 including taking down unserviceable fuel pump complete all as specified and as directed by Engineer-in-Charge. (Cat Part No. 91758601)
Supply and fix in repair Driver Coupling including taking down unserviceable driver coupling complete all as specified and as directed by Engineer-in-Charge. (Cat Pat No. 11127823)
Supply and fix in repair Solenoid switch including taking down unserviceable solenoid switch complete all as specified and as directed by Engineer-in-Charge. (Cat Part No. 91597303)
Supply and fix in repair Ignition electrode including taking down unserviceable ignition electrode complete all as specified and as directed by Engineer-in-Charge. (Cat Part No. 11924301)
Supply and fix in repair Thermo Couple including taking down unserviceable thermo couplecomplete all as specified and as directed by Engineer-in-Charge. (Cat Part No. 12000001)
Material and Labour for Servicing to dehumidifiers of Model FFB-170, FFB-300 & FFB-600 by dismantling and checking the following :- (a) Motor and starters/contactors for any loose connection/ unserviceability (b) Check bed speed and bed drive (c) Cleaning of air filters and wire mesh (d) Lubricating the bearings of motors/fan etc,. (e) Adjustment of sprocket wheel and chain (f) Checking of reduction gear unit, flexible connection of process and reactivation fans (g) Checking of air pressure balancing and air flow of the system. Note : Spares required for replacement shall be measured and paid separately under relevant items
Supply only Bed drive reduction unit suitable for dehumidifier of existing model.
Supply only React fan motor suitable for dehumidifier of existing model
Supply only Heater suitable for dehumidfiier of existing model
Supply only Safety thermostat suitable for dehumidifier of existing model
Supply only Process air filter suitable for dehumidifier of model FFB-170.
Supply only Process air filter suitable for dehumidifier of model FFB-300.
Supply only Process air filter suitable for dehumidifier of model FFB-600.
Supply only React air filter suitable for dehumidifier of existing model.
Supply only Bed failure delay timer suitable for dehumidifier of existing model.
Supply only Bed failure limit switch suitable for dehumidifier of existing model.
Supply only React pressure switch suitable for dehumidifier of existing model.
Supply only Dessict motor suitable for dehumidifier of existing model FFB-170
Supply only Dessict motor suitable for dehumidifier of existing model FFB-300.
Supply only Seal group suitable for dehumidifier of model FFB-170
Supply only Seal group suitable for dehumidifier of model FFB-300
Supply only Seal group suitable for dehumidifier of model FFB-600
Supply and fix in repair MCCB 3 Pole 125 A, 25 KA breaking capacity including taking out old unserviceable MCCB complete all as specified and as directed.
Supply and fix in repair MCB TPN 32 A, 10 KA breaking capacity including taking out old unserviceable MCB complete all as specified and as directed.
Supply and fix in repair MCB SPN 06-32 A, 10 KA breaking capacity including taking out old unserviceable MCB complete all as specified and as directed.
Supply and fix in repair 3 pole power contactor of capacity 32 Amps including taking out old unserviceable power contactor complete all as specified and as directed.
Supply and fix in repair 3 pole power contactor of capacity 25 Amps including taking out old unserviceable power contactor complete all as specified and as directed.
Supply and fix in repair battery 12V 180 AH maintenance free Lead acid battery complete all as directed.
Material and labour for Servicing and painting of 5 Ton capacity Manual type crane installed at Main Power house, greasing, oiling, Load test, complete overhauling including testing all as specifiedand directed by Engr-in-Charge
bansal construction
M/s Pooja Enterprises
M/s Sriya Enterprises
M/s Power Engineering Co
Blue chip consultancy Service
Tropical Refrigeration
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .