Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | NA₹5.0 CrRejected-Finance FARIDABAD | FARIDABAD | HARYANA | 121001 | ₹5.0 Cr | NA | Rejected-Finance reject |
| 2 | NA₹5.0 CrRejected-Finance 1350 B SHYAM LAL BAGH NEAR NAND CINEMA HISAR 125001 | HISAR | HARYANA | 125001 | ₹5.0 Cr | NA | Rejected-Finance reject |
Tender Value
₹3.7 Cr
EMD Value
₹7.4 L
Closing Date
24 Mar 2022, 3:00 pmClosed
Executive Engineer
Engg.cell, MDU, Rohtak
Construction of second floor on existing Academic Block Building (Civil, P.H and E.I) MDU-CPAS Gurugram
2022_HRY_210067_1
MDU/EE/2022/CIVIL/20
Open Tender
Civil Works
Works
150 days
MDU
Construction of second floor on existing Academic Block Building (Civil, P.H and E.I) MDU-CPAS Gurugram
2 documents required · 2 mandatory
₹15,000
Yes
₹7.4 L
Yes
21 Jun 2022
2 Mar 2022
25 Mar 2022
2 Mar 2022
24 Mar 2022
2 Mar 2022
Amount
Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
Demolishing mud phaska in terracing and disposal of material within 50 metres lead.
Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured):From brick work in mud mortar( 1000 nos ) 1CUM= 494 =102.27*494/1000 (1000NOS )
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.(600x600)
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.(600X600)
Applying priming coat withready mixed zinc chromate primer of approved brand and manufacturer on steel work
Providing and fixing bright finish brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality and a pair of lever handles with necessary screws, etc, complete.
Providing and fixing aluminium sliding bolts ISI marked,anodised(anodic coating not less than grade AC 10 as per IS:1868),tranparent are dyed to required colour or shade,with nuts and screws, etc., complete b) Aluminium i) size 300 mm x 16 mm
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : Powder coated aluminium (minimum thickness of powder coating 50 micron)For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)6.5kgXsqm of fixed windows
Powder coated aluminium (minimum thickness of powder coating 50 micron)8 kg X sq m open door & windows
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.Pre-laminated particle board with decorative lamination on both sides
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) reducing 25 % qty of windows of item no. 12.157.1.2
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight up to 35 kg and door width up to 700 mm), with necessary accessories and screws etc. complete.
Providing fixing aluminium handle of outer dia 100mm with screws etc. complete.Powder coated minimum thickness 50 micron
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.AS PER PUF PANEL (2.5KG PER SQFT)
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect for all heights/depths/storeys/basements etc.Thermo-Mechanically Treated bars of grade Fe-500D or more.Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding and placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement.4NO. STAIRS ONLY@ 75KG PER SQMT.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level:1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size GI Metal Ceiling Lay in plain Tegular edge Global white colour tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending.
Providing and fixing of P.V.C. sheet flexible type conforming to I.S.3462-1966 flooring plain coloured marble or mottled finish on a smooth damp proof base laid with adhesive recommended by manufacturer including pressing the sheet with a suitable tool to get a smooth surface all complete as directed by the Engineer-in-Charge.2.00 mm thick
Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.(Washbasin = 14) above fixed bevlled edge mirror
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.
Rehandling of malba i.e. carrying malba fourth storey to ground floor through stair case.Dismantling all work in building (including brck work, mud phasak, rcc, stone etc
Providing and applying 50/80mm thick two component, HFC blown, free from CFC/HCFC polyurethane based spray able rigid foam system, closed-cell type, designed to meet insulation requirements in roof applications. PUF shall be applied seamless in-situ and is ideal for fast return to service. PUF should be applied through a suitable metered application machine, by specialist applicators and should be covered by waterproofing system. The thickness of the individual layers of PUF applied foam should be minimum 10 - 15 mm. PUF should have the following properties: 1. Viscosity at 20°C, cps: Part A ISO 300, Part B POLYOL 600 2. Compressive strength,ASTM D-1621/94,kPa> 400 3. Tensile strength,ASTM D1623/78, kPa:>500 4. Adhesion to substrate,ASTM D4541, kPa:> 180 5. Thermal conductivity at 25C as per ASTM C518/91, W/m K:≤ 0.023 6. Closed cell content,ISO4590, %:> 96 7. Water absorption,EN12087, %:< 2.5 8. Water Vapour Transmission,EN12086, perms132 9. Flash Points, ºC: Part A ISO > 200, Part B POLYOL > 65 10. Fire resistance,DIN4102: Class B2 11. Foam Density, kg/m3 ASTM D1622: 45 to 50 12. Specific c Gravity at 20°C: Part A ISO 1.23, Part B POLYOL 1.23 It shall be applied as per manufactures specification. Rates are incl of surface preparation, grouting and chemical application only.
Providing & fixing of composite factory made dis-continuous prefabricated sandwich panel – LP/HP-80mm thick PUF for wall comprising of two sides facing of colour coated Galvanised steel sheet and sandwiched between them CFC free close cell high Density rigid polyurethane foam 40±2 kg/m3 having a thermal conductivity value of 0.023 w/mk. The outer & inner sheet shall be off white RAL9002 galvanised steel sheet of 0.5mm TCT steel min.240 Mpa having a coating Mass of min.120 gsm zinc coating total of both sides as per IS: 277 and finished with 20 microns colour coating of SMP polyester quality paint coat over a 5 micron primer on exposed side and back coat of 5 microns on inner side over a 5 microns primer. The outer and inner sheet shall have a core of 50mm thick polyurethane foam insulation. The PUF insulation shall have fire retardant and self-extinguishing properties as per IS 12436. The panels should be of required length and in 1190mm width with tongue and groove arrangement on the sides having hidden fastener jointing arrangement. The prefabricated panels shall be fixed to the support structure. The metal sheet shall conform to IS: 277 & 14246. The polyurethane insulation shall conform to IS:12436.The work shall be carried out as per direction of E.I.C. (NS)
Providing & fixing of flashing, Gutter, Down Take Pipe made out of 0.5mm TCT Galvanized steel sheet (perimeter of truss)
Providing & fixing of Guttermade out of 0.5mm PPGI/PPGL Sheet Including ridge cap
Providing & fixing of Down Take Pipe made out of PPGI/PPGL.
Providing and Laying Foamed concrete flooring (upto 300 mm thick), with cellular light weight concrete, by the mixing a lightweight mortar result from water, Portland cement, fine sand including or alone fly ash and preformed stable foam. The foam to be produced with the help of a foam generator by using foaming agent. The air content to be between 40 to 80 percent of the total volume. The bubbles vary in size from around 0.1 to 1.5 mm in diameter. The density shall be 900 to 1000 kg/cum. (NS)
Supply, Installation, Fixing of Stored Pressure (ABC Dry Chemical Powder) type Fire Extinguisher of Capacity 6 kg Confirms to IS 15683, bearing ISI mark complete with brass forged squeeze grip type valve fitted with pressure gauge , pressurize with dry Nitrogen gas filled, with discharge nozzle with wall mounting bracket, having fire rating. 6kg
Public Health work Dismantling old C.I. pipes including excavation and refilling trenches after taking out the pipes, breaking lead caulked joints, melting of lead and making into blocks, including stacking of pipes at site lead up to 50 metre: 80 mm diameter C.I. pipe
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing white vitreous chinaware pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous chinaware flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing white vitreous chinaware flat back half stall urinal of size 580x380x350 mm with white PVC flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern
Providing and fixing toilet paper holder : vitreous chinaware
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:white chinaware wash basin Size 630 mm X 450 mm with single 15 mm C.P brass pillar tap. tap
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
Providing and fixing in position best Indian make coat and hat hooks fixed into wall with C.P. brass screws and rawl plugs etc. complete including cutting and making good the walls etc. C.P. BRASS Two Way
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chase and making good the wall etc. a) 20 mm nominal outer dia pipes
b) 25 mm nominal outer dia pipes
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board 610x460 mm bowl depth 200 mm
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible Pipe a) 32 mm dia (for wash basin)
b) 40 mm dia (for sink and urinal)
Providing and fixing Unplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket Type A 110mm o/d SWR UPVC pipe lines laid complete
Providing, Fixing, testing & commissioning of health faucet with regulator with flexible pipe 1.5 m long, wall hooked complete as required. (Make Hindware/laquar/Cera)
Wall Mountable Water Purifier With Transparent Cover. Mineral ROTM Technology - Double Purification by RO+UF with TDS Controller - KENT PRIDE
Providing, fixing, jointing and testing in position ISI marked (IS:4985) UPVC pipes of min 6 Kg/ Sqcm rating with fitting for waste pipe from fixtures to floor trap including reduces, enlarger, socket, couplers, bends, tees etc including fixing at wall/ ceiling level supported by clamp & hangers etc. cutting holes in wall/ floors/ slabs and making good the same with cement concrete 1:2:4 complete as required. 32 mm dia.
50 mm dia.
Providing & fixing UPVC Floor trap of self cleansing design with stainless steel grating complete in all respects. Multi Floor Trap (5" Ht) with height raiser and branch saddle strip of 50/75 mm outlet
Plain Floor Trap 100X100 outlet and with height raiser
P-Trap type Floor Trap 110 x 110 mm
Floor drain size:(100X50)
Removing and shifting of PVC water tank from terrace to store complete as per to the satisfaction of Engineer-in-charge.
Electrical work Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group C
Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe, without separate control switch Group C
Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modulartype socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group C
Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthing , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group C
Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 2.50 Sqmm(1/1.80mm)
1 run of Size 4 Sqmm(1/2.24mm)
1 run of Size 6 Sqmm(1/2.80mm)
1 run of Size 10 Sqmm(1/3.50mm)
2 run of Size 2.50 Sqmm(1/1.80mm)
2 run of Size 4 Sqmm(1/2.24mm)
Supply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and sealed in existing pipe/channel and making necessary connection complete in all respect up to the entire satisfaction of the Engineer-in charge of the work. 2 pair telephone wire
Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required
PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 20 mm dia.
PVC pipe of 25 mm dia.
PVC pipe of 32 mm dia.
PVC pipe of 40 mm dia.
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. step type Fan Regulator 2 modules 300 watt
Telephone Socket outlet modular type
Blanking plate
RJ 45 Computer DATA socket outlet for CAT 6 or CAT6e cable
Supplying,installation,testing and commissioning of Passive lnfrared(PIR) based occupancy sensor , non regulating programmable type, suitable for for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required. Make Crabtree/ Honey well
Supply and erection of suitable MS/GI Box covered with 5 mm thick Bakelite sheet as below 75 mm x 75 mm x 60 mm deep M.S. box
200 mm X 150 mm X 60 mm deep metal box
180 mm X 100 mm X 60 mm deep M.S. Box
1 & 2 Modules including combined plate for Telephone and data
3 Modules
4 Modules
6 Modules
8 Modules
12 Modules
Supply and erection of 10.5 cm dia M.S. Fan box including 8 mm dia 30 cm long M.S. Rod made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job.
Supply and Fixing 3 mm thick Bakelite sheet cover on existing MS/PVC junction box/tee etc including fixing with brass screws and washers.
Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required
Fixing of LED Down lighter 7 to 28 Watt on ceiling or in false ceiling , including cutting/making hole in ceiling including making connections etc as required
Erection of exhaust fan in existing opening ,complete with necessary earthling of fan including carriage from PWD store to the site of work.
MCCB,DISTRIBUTION BOARDS,MCB's, RCCB's,CHANGE OVER etc. 4 Pole MCCB 63 to 100 amp, 25 KA
4 Pole MCCB 125 to 160 amp, 25 KA
4 Pole MCCB 200 to 250 amp, 25 KA
Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing)
TPN DB Horizontal type Double Door 8 way ( 8 incoming and 3phase*8 outgoing)
TPN DB Horizontal type Double Door 12 way ( 8 incoming and 3phase*12 outgoing)
Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole
40 amp to 63 amp. Double pole
40 amp to 63 amp. MCB's FOUR POLE
Supply and erection double pole/Four pole Residual (RCCB/ELCB) on 240/415V, 50Hz. AC supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. FP RCCB 30ma sensitivity , 40 A
Supply and erection of blanking sheet in existing distribution board.
Supply and erection of U- PVC Trunking/Channel of following size including cost of fixing on wall, floor and ceiling etc. with required material complete the job in all respect up to entire satisfaction of the Engineer-in-charge of work. 50x 50 mm Make: Anchor
Supply and erection of MS cable tray , duly painted as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 200 X 50 X 2 mm
Supply and erection of cable tray cover made of 1.25 mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. GI cable tray cover, suitable for cable tray of 200 X 50 X 2 mm
Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required.
Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode.
Supplying and laying 25mm x 3mm G.I. strip at 0.5 metre below ground as strip earth electrode including soldering etc. as required.
Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required.
Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material.
Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required.
Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop carthing as required.
Supply and erection of 20mm x 3 mm thick GI, tape fixed with suitable G.I. staples of same size.
Supply and erection of 25mm dia 1.5 metre long lightning GI. tube rod tapered into a point at the top with 16cm x 16cm x 3mm thick G.I. base plate and necessary nuts and bolts with washers.
Providing and fixing testing joints made of 20mm x 3mm thick G.I. strips 125 mm long with 4 nos. G.I. bolts and nuts with washers complete.
Supply and erection of suitable compression type brass cable glands for underground cable 120 sqmm to 185 sqmm cable 3 to 3.5 core
Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work 70 sqmm Make-Ascon/Dowells
Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge (HSR 20.71) (Make- Havells,orient) Fans Should be energy efficient and sample should be passed through department before installation ii) 48" (1200mm)
Supplying, laying, effecting terminations, testing and commissioning of 0.51 mm dia Cu. Conductor, twisted, colour coded with polythene capor barrier, telephone cables in the existing tray or in conduit including providing &fixing conduit pipe or cable tray as required from building tag block to the floor as required entire satisfaction of the Engineer-in-charge of the work . Supplying & fixing 10 pair krone tag block with enclosure.
P/L 10 Pair of PVC insulated PVC sheathed multi core jelly filled armored telephone.
Supplying, laying, testing & commissioning of 3.5 C X 120 sq.mm.LT aluminium armoured XLPE cable on surface/tray as per entire satisfaction of engineer in charge of the work entire satisfaction of the Engineer-in-charge of the work .
Supplying, laying, testing & commissioning of 3.5 C X 120 sq.mm.LT aluminium armoured XLPE cable in pipe/existing open trench/closed trench as per entire satisfaction of engineer in charge of the work.
Supplying, laying, testing & commissioning of 4 C X 35 sq.mm.LT PVC insulated and FR PVC sheathed copper conductor flexible cable on surface/tray as per entire satisfaction of engineer in charge of the work.
Supply and erection of recessed vertical TPN Distribution board double door IP 54 with incomer provision of 125 A MCCB 8 way entire satisfaction of the Engineer-in-charge of the work
Supply and erection of recessed vertical TPN Distribution board double door IP 54 with incomer provision of 125 A MCCB 12 way entire satisfaction of the Engineer-in-charge of the work
Supply and erection of PVC 250mm ventilator exhaust fan make- Orient/havells/crompton entire satisfaction of the Engineer-in-charge of the work
Supply of LED Recessed grid - ceiling luminaire of 34/36 W, lumen efficacy > 120 LM/ Watt size 2'x2' energy efficient white colour, made of high grade poly carbonate body working hour minimum 50000 hours, operation on single phase AC supply complete in all respect upto the entire satisfaction of Engineer- in -charge of the work including making necessary connections etc entire satisfaction of the Engineer-in-charge of the work . (Make: Philips, Havells) Fittings Should be energy efficient and sample should be passed through department before installation
Supply of Recessed mounting LED round Down Light fitting of 15W, lumen efficacy > 120 LM/ Watt energy efficient white colour, made of high grade poly carbonate body working hour minimum 50000 hours, operation on single phase AC supply complete in all respect upto the entire satisfaction of Engineer- in -charge of the work including making necessary connections etc entire satisfaction of the Engineer-in-charge of the work . (Make: Philips, Havells). Fittings Should be energy efficient and sample should be passed through department before installation
Supply of Recessed mounting LED round Down Light fitting of 10W, lumen efficacy > 120 LM/ Watt energy efficient white colour, made of high grade poly carbonate body working hour minimum 50000 hours, operation on single phase AC supply complete in all respect upto the entire satisfaction of Engineer- in -charge of the work including making necessary connections etc entire satisfaction of the Engineer-in-charge of the work . (Make: Philips, Havells,). Fittings Should be energy efficient and sample should be passed through department before installation
Supply of 10W LED Linear Light Fitting lumen efficacy > 120 LM/ Watt 600 mm (L) energy efficient white colour, made of high grade poly carbonate body working hour minimum 50000 hours, operation on single phase AC supply complete in all respect upto the entire satisfaction of Engineer- in -charge of the work including making necessary connections etc.(Make: Philips, Havells). Fittings Should be energy efficient and sample should be passed through department before installation entire satisfaction of the Engineer-in-charge of the work
Supplying,installation,testing and commissioning of Microwave technology based occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10Amp , for mounting height up to 2.6 mtr and for 5m X 20m coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required entire satisfaction of the Engineer-in-charge of the work . Make- Crabtree/Honeywell
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required entire satisfaction of the Engineer-in-charge of the work .
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required entire satisfaction of the Engineer-in-charge of the work . (Approved Makes: JCT, Notifier, Edward,TYCO) sample should be passed through department before installation
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required entire satisfaction of the Engineer-in-charge of the work . (Approved Makes: JCT, Notifier, Edward,TYCO)DSR-2018, 17.2.5 sample should be passed through department before installation
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required entire satisfaction of the Engineer-in-charge of the work (Approved Makes: JCT, Notifier, Edward,TYCO)DSR-2018, 17.2.9 sample should be passed through department before installation
Supplying, installation, testing & commissioning of addressable manual call point complete as required entire satisfaction of the Engineer-in-charge of the work . (Approved Makes: JCT, Notifier, Edward,TYCO)DSR-2018, 17.2.14 sample should be passed through department before installation
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required entire satisfaction of the Engineer-in-charge of the work . (Approved Makes: JCT, Notifier, Edward,TYCO)DSR-2018, 17.2.15 sample should be passed through department before installation
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required entire satisfaction of the Engineer-in-charge of the work . (Approved Make- Polycab /KEI/Excell Cable)
Supply, installation testing and commissioning of Exit signage Board. complete with all accessories as per required. Size - 6"x 12" entire satisfaction of the Engineer-in-charge of the work .
Supply, installation, connecting ,testing and commissioning of the following components for IP- CCTV system complete as required. 1/2.7" CMOS IP Dome Camera , Picture Elements 1080p (1920 x 1080 pixels), Resolution 1080p / 720p / VGA, 30 FPS (All Resolutions) ,True Day/Night with Removable IR Cut Filter, IR Illuminator (25 Meter Max Effective Range) 850nm, Minimum Illumination 0.0001 (0.0 With IR Illumination), Dynamic Range 69dB, Compression( H.264, MJPEG), Bandwidth Configurable , Max Streams -4, Gain Control AGC, White Balance Auto / Manual / ATW , Backlight Compensation On/Off,3-9mm Vari focal entire satisfaction of the Engineer-in-charge of the work . Make - Honeywell/ Pelco/ Bosch.sample should be passed through department before installation
S/I/T/C 3 MP Bullet / Dome Camera , ONVIF profile s ,UL , CE , FCC Certified , 1/2.8" CMOS sensor ,3.6 mm fixed focal , Min Illumination :0.05 Lux @ (F1.2, AGC ON), 0 Lux with IR , Shutter Time : 1/5s ~ 1/20,000 s , Video Compression : H.265 , H.264 , frame rate 30 fps @ 3MP , Edge analytics : line crossing , perimeter intrusion , stationary object ,Inbuilt IR LED , IR distance upto 30 mtrs ,IP 66 , POE entire satisfaction of the Engineer-in-charge of the work .(Approved make - Impulse, Axis, Bosch) sample should be passed through department before installation
Supply Installation, Testing & Commissioning of Godrej Security Solutions 8 Channel Full HD 1080P DVR (White) entire satisfaction of the Engineer-in-charge of the work (2MP8CHANNELDVR) sample should be passed through department before installation
Wall mounted 6U closed racks with power supply complete as required for the network racks entire satisfaction of the Engineer-in-charge of the work
Supply , laying, terminating, testing of cat-6 cable in FRLS existing PVC conduits entire satisfaction of the Engineer-in-charge of the work
Supply Installation, Testing & Commissioning of Intel i7 4th Generation processor 3Ghz, 4GB RAM with 2TB hard disk, DVD RW/keyboard/ optical mouse/LAN card/19” LED monitor. Minimum 6 USB ports. With pre-loaded licensed Windows 7 Professional software, software license for remote monitoring of CCTV system as per entire satisfaction of the Engineer-in-charge of the work . Make- Dell/Acer/HP
Supply, installation, testing and commissioning of color high resolution LED monitor of comprising of 1 nos. 32 inch display complete with all supports, accessories entire satisfaction of the Engineer-in-charge of the work . Make- Dell/Acer/HP
RJ-45 outlets near the cameras entire satisfaction of the Engineer-in-charge of the work
Media Converter SM/SFP Module entire satisfaction of the Engineer-in-charge of the work
LIU to Media converter connectivity entire satisfaction of the Engineer-in-charge of the work .
8 port loaded fiber LIU box with pigtails and couplers entire satisfaction of the Engineer-in-charge of the work
Supply, installation, testing and commissioning of 10 KVA online 3-phase UPS system Make - Autometer/GE/Schneider entire satisfaction of the Engineer-in-charge of the work sample should be passed through department before installation
Supply and installation of 12 V 65 AH dry sealed battries with interconnecting cables of reqired size, stand and complete in all respect Make- Exide/Amaron entire satisfaction of the Engineer-in-charge of the work sample should be passed through department before installation
Supply and installation of 2 ton capacity 5 star split AC inverter type with copper condensing coil Make - Bluestar/ O'General/Mitshubshi entire satisfaction of the Engineer-in-charge of the work sample should be passed through department before installation
Supply and installation of 5 KVA copper voltage stablizer of valtage range- 140-270 volts Make - Bluebird/Skybird/Logicstst entire satisfaction of the Engineer-in-charge of the work sample should be passed through department before installation
Supply of MS stand for split AC installation of outdoor unit entire satisfaction of the Engineer-in-charge of the work
Providing and fixing extra copper piping as per required size entire satisfaction of the Engineer-in-charge of the work. Make-Mandev
Providing and fixing of 20 mm PVC drain pipe entire satisfaction of the Engineer-in-charge of the work Make- Supreme/Prince/Ahirvad
Providing and fixing of PVC copper wire 2.50 Sqmm 3 core extra for installation of ACs Make- Havells/Polycab/Anchor entire satisfaction of the Engineer-in-charge of the work
Providing and fixing of PVC copper wire 2.50 Sqmm 4 core extra for installation of ACs Make- Havells/Polycab/Anchor entire satisfaction of the Engineer-in-charge of the work
Providing and fixing of insulation pipe for covering the copper pipes entire satisfaction of the Engineer-in-charge of the work
Pawan Kumar
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .