Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹49.0 L+₹12.2 L (33.3%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 |
Tender Value
Refer Docs
EMD Value
₹86,000
Closing Date
27 Jul 2023, 6:00 pmClosed
GE CENTRAL BANGALORE
ASC CENTRE AND COLLEGE AGRAM POST BANGALORE 560007
REPAIR AND MAINTENANCE OF STREET LIGHT OTHER CONNECTED WORKS AT VARIOUS LOCATIONS OF ASC NORTH AND ASC SOUTH UNDER AGE E AND M OF UNDER GE CENTRAL BANGALORE
2023_MES_605471_1
8332E
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
GE CENTRAL BANGALORE
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE CENTRAL BANGALORE
₹86,000
Yes
22 Sept 2023
26 Jun 2023
29 Jul 2023
26 Jun 2023
27 Jul 2023
10 Jul 2023
26 Jun 2023 - 1 Jul 2023
Amount
Excavation in trenches in hard/dence soil,not exceeding 1.5 Mtr wide and not exceeding 1.5 mtr in depth for laying of UG Cable etc and geting out in hard/dense soil complete all as directed.
Returning filling in including spreading, leveling, watering and well ramming in layers not exe. 25 cm.
Removing exacavated surplus excavated material to a distance exceeding 50m and depositing where directed at a level not exe. 1.5 m above the starting point.
M&L for Sand cushioning/sand covering for underground cable protection complete all as specified. Note: Punned thickness only will be measured and paid.
Supply and laying sub class 'B' bricks of old size (standard size as per local availability) right angle of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
M&L for PCC 1:3:6 type C-1 using 20 mm graded mechanically crushed stone aggregate for mass filling in pole pit, coping and foundation etc, complete all as specified and directed.
Supply & laying XLPE insulated, PVC sheathed, strip armoured electric cable with stranded aluminium conductor working voltage upto1100 volt of 10 Sqmm 2-core as per IS 7098 Pt I in trenches, culvert, through pipe etc including connecting both end with proper size of alluminium lugs duly crimped with die press crimping device and cable gland complete all as specified and directed by Eng-in-charge.Note Excavation, earth work, sand cushioning, cable cover, returning/filling will be measured and paid seperately).
All as per item No 07 here-in-before but cable of size 16 Sqmm 2 core.
All as per item No 07 here-in-before but cable of size 16 Sqmm 4 core.
All as per item No 07 here-in-before but cable of size 10 Sqmm 4 core.
All as per item No 07 here-in-before but cable of size 25 Sqmm 4 core.
Supply and fixing in replacement Mild steel galvanized pipe light grade for protection & passing of LT cable fixed to poles/walls/laid under floor/roads complete including fittings/clamps as required at site all as specified for size of 25 mm bore dia.
S&F in replacement MCB 4 pole 63 Amps, 415 Volts all as directed..Make- Indo asian optium /Havells/siemens
S&F in replacement MCB 4 pole 40 Amps, 415 Volts all as directed..Make- Indo asian optium /Havells/siemens
S&F in replacement MCCB 4 pole 63 Amps, 415 Volts, 25 KA breaking capacity, with adjustable thermal and fixed magnetic release all as directed..Make- Indo asian optium /Havells/siemens
S&F in replacement MCCB 4 pole 100 Amps, 415 Volts, 25 KA breaking capacity, with adjustable thermal and fixed magnetic release all as directed..Make- Indo asian optium /Havells/siemens
S&F in replacement MCCB 3 pole 160 Amps, 415 Volts, 25 KA breaking capacity, with adjustable thermal and fixed magnetic release all as directed..Make- Indo asian optium /Havells/siemens
Trimming/cutting of the tree branches/bushes which falls within a clear distance of 3 meter from all sides from the HT/LT over head conductor & within line of conductors, and shifting waste to nearby waste depot & cleaning area complete . Note : Horizontal distance of tree touching to the over head lines shall be measured for the purpose of payment.
S & F Tmelite 40 A 3 pole /230 V Digital time switch, pole mounted single door outdoor type totally enclosed for street light controlling panel incl fixing arrangement with 40X5mm clamp 2 Nos with nuts and bolts complete accessories. Make: Indoasian cat No TL040DB0 or equivalent make of Phillips/CG/Bajaj .
S&F New generation, post-top,lattern landscape luminaire 15 watts, energy saving, powder coated aluminium die cast and spun aluminium body with clear/opel diffuser ,environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium with high power LEDs as light source, IP -65 all as directed.Make: Havells cat No RUBYMIMIPT15WLED830PSYMTOPC or equivalent make of Phillips/CG/Bajaj .
Supply and fix LED street/building light fitting, 1x45 watts with highly effective and efficient luminaire rubust design IP-66 fixed on walls with all fixing accessories such bend pipe, square/round blocks, clamps/screws, etc and connecting up with three core round flexible copper conductor cable of size 1.5 sqmm complete all as specified and directed. Make Havells/Phillips/Surya
Supply and fix LED street/building light fitting, 1x60 watts with highly effective and efficient luminaire rubust design IP-66 fixed on walls with all fixing accessories such bend pipe, square/round blocks, clamps/screws, etc complete all as specified and directed. Make Havells/Phillips/Surya
S&F energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium iP65 flood light with high power leds as light source, suitable for highlighting architectural facade highmast and general purpose lighting of 120 watt lamp with all accessories for fixing on pole/wall and electrical connection. Make Havells/Phillips/Surya
S&F energy saving environmental friendly long life, with highly effective and efficient luminaire robust design LED street/building security light 1x 70 Watt LED pressure die-cast aluminium, heat resistant, toughened glass diffuser, IP65/66 and wired with all accessories and connection up with 3 core flexible copper conductor cable 4/20 mm size, 1.5m long and testing on installation all as specified and directed. Make: Havell's Cat No. ENDURACITYLINERNEOSL70WLED757PASYBOTG or equivelant of make Bajaj/CG/Shakti/Wipro
M&L for GI tubing Bracket 40mm medium grade 1.5 mtr lenth,bent to 120° shape including grouting/fixing 2-Nos clamps required size,including bolts for fixing street light complete.
Supply & fix in repair FRP junction box (weather proof) of size 240 x 130 x 110mm including single phase connector arrangement alongwith suitable clamps including MCB SP.5 Amps 10 KA rating,fixing with flat iron clamps, nuts and bolts complete all as specified and directed. Make : Sintex or equivalent
Supply and fix, in repair PVC insulated three core,1.5 Sqmm cables with copper conductor copper flexible cable with earth conductor complete all as specified and directed.Make : poly cab/Havells/finolex
Supply and fix in repair Rigid Non-metallic PVC conduit pipe exclusive of junction boxes but inclusive of all Tees,bends elbows,reducers, bell mouth tube end and fixing acessories such as couplers, lock nuts,saddles pipe hooks etc and fixing to poles etc of size 20 mm external dia. etc all as specified.
Taking down old unserviceable light fitting HPSV/LED street light fitting of any make and type complate with accessories opening and checking defective/unserviceable accesssories/spare parts and replacing the same with new one after cleaning dust from internally & externally surfaces of light fittings including cleaning of acrylic cover cover, refixed the light fitting in same position after doing the necessary testing, complete all as directed. Note : (i) Spare parts shall be measured and paid seperately as "Fixing only" under items Nos 30 to 41 & 220 here-in-below of this BOQ. (ii) The cost of bolt, nut & washers etc required if any shall be deemed to the included in unit rate.
(a) Sodium vapour lamp 150 watts, 230 volts
(b) Ballast any type suitable for 150 watts HPSV street light fittings
(c) capacitor 20MFD suitable for 150 watts HPSV street light fittings
(d) Ignitor suitable for Street/security light fittings HPSV type 150 watts
(e) LED Driver 240 Volt 200 Watt for street light / Flood light as per existing model complete all as directed.
(f) LED Driver 240 Volt 150/160 Watt for street light/Flood light as per existing model complete all as directed.
(g) LED Driver 240 Volt 100/120 Watt for street light as per existing model complete all as directed.
(g) LED Driver 240 Volt 70/72 Watt for street light as per existing model complete all as directed.
(h) LED Driver 240 Volt 60 Watt for street light as per existing model complete all as directed.
(j) LED Driver 240 Volt 45 Watt for street light as per existing model complete all as directed.
(k) LED Driver 240 Volt 30/25 Watt for street light as per existing model complete all as directed.
(l) LED Driver 240 Volt 25 /45 Watt for street light as per existing model complete all as directed.
Comprehensive maintenance/periodical maintenance/servicing and repair of standby Eco friendly/acoustic type DG set 62.5 KVA at ASC Record South of any make including 'B' check 250 Hrs or 6 months which ever is earlier complete all as specified and as directed. Note : 1. Repair & maintenance should be carried out as per maintenance schedule prescribed in repair and maintenance mannual through qualified and experianced mechanic from the servicing centre who is conversant with the DG set and report should be submitted by the contractor. 2. Rate quoted by the contractor includes the fixing charges for replacement of parts specified in relevant item here in after. 3. The tenderer shall produce qualification and experiance cerificate of the mechanic to the Engineer in charge and approved personal only will be allowed to carried out the work. 'B' check (i) Lubricant oil leaking (ii) Operation and repairs to lubricant oil leakage and cooling system leakage, rediator operation with coolant. hoses and connection, belt connection and tension. Fan hub drive pulley and water pump operation and cleaning of radiator cooling system. (iii) Leaking in air intake system, maintenance filter & air cleaner piping connection. (iv) Fuel line and connection, fuel injection pump, cleaning of fuel tank for removing sediments (v) Leakage in exhaust system and exhaust restriction, drain out condensate trap, cleaning & maintenance of exhaust (vi) Battery charging system & topping up electrolyte and maintenance of specific gravity. (vii) Cleaning of engine tightening of all nut, bplt, washer and unusual vibration. (viii) Checking to electric connection and smooth operation of generator control panel, greasing to all bearing and movable parts, measurements and recording winding insulation resistance cleaning up complete generator/alternator.(ix) Spares required to make the set funcional shall be measured under item No 25 here-in-below as "SUPPLY ONLY". Quoted rate is deemed to be inclusive of taking down & fixing for undermentioned spares.
Supply only following parts for 62.5 KVA DG sets as specified for ser item No 42 all as per existing make or as recommendation by manufacturer and all as directed . . (a) Supply only Fan belt set as per manufacture
(b) Supply only Coupling main alternator
(c) supply only Fuel filter
(d) Supply only Oil Filter
(e) Fuel tank cleaning
(f) cleaning/discaling of rediator internally and externally.
(g) Servicing of self starter.
All as per item Sl No 42 above but capacity of DG set 40 KVA at Post office pump house
Supply only following parts for 40 KVA DG sets as specified for ser item No 50 all as per existing make or as recommendation by manufacturer and all as directed . (a) Supply only Fuel filter
(b) Supply only Oil Filter
(c) Fuel tank cleaning
(d) cleaning/discaling of rediator internally and externally.
(e) Servicing of self starter.
(f) Supply only Fan belt set as per manufacture
All as per item Sl No 42 above but capacity of DG set 15/20 KVA at VOC and Gill stedium pump house
Supply only following parts for 15/20 KVA DG sets as specified for ser item No 59 all as per existing make or as recommendation by manufacturer and all as directed . (a) Supply only Fuel filter
(b) Supply only Oil Filter
(c) Fuel tank cleaning
(d) cleaning/discaling of rediator internally and externally.
(e) Servicing of self starter.
(f) Supply only Fan belt set as per manufacture
M&L for carrying out regular checking and maintanance of 62.5 KVA capacity at 531HP following diesel generating sets including connected alternator and control panels, and carrying out routine 'A' check of the set complete for smooth functioning all as per manufacturer's instructions and as directed. NOTES :- (i) Control switches such as MCCB, Main switch, contactors and multi display meter shall be out of scope of the item of work and the rate quoted shall exlusive of servicing/ maintenance of the above said fittings. (ii) Servicing of DG set alongwith connected alternator attached and control panel including 'A' check of the Engine shall be carried out at regular intervels as specified and as directed by the Engineer-in-Charge and the contractor shall carry out periodical inspections during the maintenenace period and he shall be responsible for the smooth functioning of the DG set all the time. (iii) Spare parts required for replacement during the maintenance period shall be measured and paid separately at supply only rates and cost of labour for fixing these spares shall be deemed to be inluded in the rate quoted for this item (iv) Cost of all consumables required during the maintenance period shall be deemed to be included in the rate quoted for this item. (v) The contractor shall also attend to the breakdown calls and depute necessary technician for repair/maintenence works as and when required with out delay during the maint period. (vi) List of checks to be carriedout under 'A' check is attached as Appendix 'A' to the Particular specifications.
All same as per item No 64 here-in-above but for 40 KVA capacity at ASC Records
All same as per item No 64 here-in-above but for20 KVA capacity at Grill Stedium
All same as per item No 64 here-in-above but for15 KVA capacity ASC Records
All same as per item No 64here-in-above but for16 KVA capacity VNC/VOC
Dismantling DC dynamo/alternator of battery charging system 12/24 Volt complete servicing including replacement of bushes, bearing,carbon brushes, diodes any other minor parts required all as directed & fixing on engine testing/commissioning complete for any capacity of DG set
Replacement of unserviceable contactor AC operated 4 pole 415 V suitable for DG set 62.5KVA as per the existing type and model in the AMF panel complete all as specified and as directed.
Replacement of unserviceable contactor AC operated 4 pole 415 V suitable for DG set 40 KVA as per the existing type and model in the AMF panel complete all as specified and as directed.
Replacement of unserviceable contactor AC operated 4 pole 415 V suitable for DG set upto upto 20 KVA as per the existing type and model in the AMF panel complete all as specified and as directed.
Replacement of fuel pipe PVC metal braided of as per existing length fitted with benzo adopters to both sides with benzo bolts & washers.
Repair and servicing of existing canopy of eco friendly DG Set cleaning of internal & external parts, tightening of loose parts, replacing of unserviceable door locks and keys, replacing of damaged or burnt inside sponge insulations complete all as directed.
Repair/replacement of PCB board of 20 to 100 KVA as per existing make and model complete all as specified as directed
Dismantling self starter of engine of DG set capacity 15 KVA upto 100 KVA & repairing the starter by replacing carbon brushes, bearings, solenoid coil, brush, brush holders complete rewinding,servicing refixing after repair, testing/commissioning complete all as directed by Engr-in-Charge.
Supply and fix SCR controlled battery charger 12V /24V 15A with TRICKLE and BOOSTING facility, DC voltmeter, Ammeter, toggle switch etc in charge necessary connection from AC supply to Battery Charger and DC wiring to the battery with crocodile clip etc as required complete all as specified and as directed. Make : M/s. Naren or equivalent Engineer in charge approved make.
Replacement of door hingesfor DG set canopy complete all as specified and directed
Supply only engine oil 15W40 in sealed containers complete all as specified and directed
Supply only coolent premixture in sealed containers complete all as specified and directed
Supply only Battery lead suitable for Battery 12 Volt AH along with copper lugs and colour of Red and Black for +ve and -ve with brass terminal
Supply and fix digital voltmeter 0 to 500 volts including taking out unserviceable voltmeter complete all as specified and as directed. Make-MECO/L&T/IMP/SALZER
Supply and fix digital ampermeter 0 to 600 Amps including taking out unserviceable ampermeter complete all as specified and as directed. MECO / L&T/ IMP / SALZER
Supply and fixing in replacement of battery 12 Volts, upto 100 Ah as per site requirement for DG Sets all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60cmx6.3 mm thick buried directly in ground (Earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connecting with steel GI earth wire 4mm dia by means of bolt nut check nuts and washers including PCC pit with 1:2:4 type B-1 using 20mm graded stone aggregate and frame cover of angle iron 25x25x6mm, MS sheet 3mm thick, and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering common salt chorcoal funnel wiremesh, earthwork in any type of soil returning filling in and removal of soft/loose soil to a distance n. exc 5 mtr including earth test point and making connections, testing on completion all as per electric plate No 5 of SSR Part-I and directed by engr-in-charge at site including taking down of old U/S eartning materials NOTE : The unit rate quoted shall be inclusive of 7.5 mtr earth lead.
M&L for carrying out regular checking and maintanance of 100 KVA capacity at 531PH following diesel generating sets including connected alternator and control panels, and carrying out routine 'A' check of the set complete for smooth functioning all as per manufacturer's instructions and as directed. NOTES :- (i) Control switches such as MCCB, Main switch, contactors and multi display meter shall be out of scope of the item of work and the rate quoted shall exlusive of servicing/ maintenance of the above said fittings. (ii) Servicing of DG set alongwith connected alternator attached and control panel including 'A' check of the Engine shall be carried out at regular intervels as specified and as directed by the Engineer-in-Charge and the contractor shall carry out periodical inspections during the maintenenace period and he shall be responsible for the smooth functioning of the DG set all the time. (iii) Spare parts required for replacement during the maintenance period shall be measured and paid separately at supply only rates and cost of labour for fixing these spares shall be deemed to be inluded in the rate quoted for this item (iv) Cost of all consumables required during the maintenance period shall be deemed to be included in the rate quoted for this item. (v) The contractor shall also attend to the breakdown calls and depute necessary technician for repair/maintenence works as and when required with out delay during the maint period. (vi) List of checks to be carriedout under 'A' check is attached as Appendix 'A' to the Particular specifications.
All same as per item No 87 here-in-above but for 100 KVA capacity at TB-IV (North) pump house.
All same as per item No 87 here-in-above but for 82.5 KVA capacity at FIU Lab
All same as per item No 87 here-in-above but for 63 KVA capacity 598 PH
All same as per item No 87 here-in-above but for45 KVA capacity at VIP NO-2 PH Collage.
All same as per item No 87 here-in-above but for40 KVA capacity at AT RECORD Collage
All same as per item No 87 here-in-above but for 30 KVA capacity at 100 Map Domlur
All same as per item No 87 here-in-above but for30 KVA capacity at EME WORKSHOP Collage
All same as per item No 87 here-in-above but for30 KVA capacity at Meeret Block
All same as per item No 87 here-in-above but for 25 KVA capacity at PH-NO1 Collage
All same as per item No 87 here-in-above but for25 KVA capacity at TB-IV PH (N)
All same as per item No 87 here-in-above but for20 KVA capacity at 70 MAJ Map Ph
All same as per item No 87 here-in-above but for20 KVA capacity at Domlur Pump House
All same as per item No 87 here-in-above but for 15 KVA capacity VOC/VNC
All same as per item No 87 here-in-above but for15 KVA capacity BAffle Range.
M&L for carrying out scheduled 'B' check 100 KVA capacity at 531PH Diesel Generator Sets including connected alternator and carrying out routine servicing of the engine as per manufacturer's instructions including consumables complete for smooth functioning of the set all as specified and as directed. Note for item No. 2 :- (i) Cost of all consumables required during the servicing / maintenance of the DG Set shall be deemed to be included in the rate quoted for this item. (ii) Spare parts, filter elements, engine oil, distilled water and radiator coolant liquid required for replacement during the B- Check & A Check shall be measured and paid seperately (iii) AMF Panel and control switches such as MCCB, Main switch, contactors, multi display meter and engine control unit shall be out of scope of the item of work and the rate quoted shall exlusive of servicing/ maintenance of the above said fittings. (iv) List of checks to be carried out under 'B' check is attached as Appendix 'B' to the Particular specifications. (v) List of checks to be carriedout under 'B' check is attached as Appendix 'B' to the Particular specifications.
All same as per item No 102 here-in-above but for100 KVA capacity at TB-IV (North) pump house.
All same as per item No 102 here-in-above but for82.5 KVA capacity at FIU Lab
All same as per item No 102 here-in-above but for 63 KVA capacity 598 PH
All same as per item No 102 here-in-above but for 45 KVA capacity at VIP NO-2 PH Collage.
All same as per item No 102 here-in-above but for 40 KVA capacity at AT RECORD Collage
All same as per item No102 here-in-above but for 30 KVA capacity at 100 Map Domlur
All same as per item No 102 here-in-above but for 30 KVA capacity at EME WORKSHOP Collage
All same as per item No 102 here-in-above but for30 KVA capacity at Meeret Block
All same as per item No 102 here-in-above but for 25 KVA capacity at PH-NO1 Collage
All same as per item No 102 here-in-above but for 25 KVA capacity at TB-IV PH (N)
All same as per item No 102 here-in-above but for 20 KVA capacity at 70 MAJ Map Ph
All same as per item No 102 here-in-above but for 20 KVA capacity at Domlur Pump House
All same as per item No 102 here-in-above but for 15 KVA capacity VOC/VNC
All same as per item No 102 here-in-above but for15 KVA capacity BAffle Range
Supply only fuel filter elements with 'O' Rings for following DG sets:100 KVA 85 KVA capacity
All same as per item No 117 here-in-above but for DG Set of capacity 63 KVA to 45 KVA
All same as per item No 117 here-in-above but for DG Set of capacity 40 KVA to 30 KVA
All same as per item No 117 here-in-above but for DG Set of capacity 25 KVA to 15 KVA
Supply only oil filter/catridges as per existing one or as approved for 100 / 85 KVA Capacities DG sets
All same as per item No 121 here-in-above but for DG Set of capacity 63 KVA to 45 KVA
All same as per item No 121 here-in-above but for DG Set of capacity 40 KVA to 30 KVA
All same as per item No 121 here-in-above but for DG Set of capacity 25 KVA to 15 KVA
Supply only Maintaince free battery with PVC body 12 volt 100-130 AH
Supply only the following materials required for maintenance of DG Sets : (a) coolant Concentrate
(b) battery Electrolyte Grade 1250
(c) Distilled water
(d) Cotton Waste Superior quality
(e) Replacement of engine oil with new Engine oil 50:90 grade as directed
Supply only fan belts for replacement of u/s fan belts as per sample and make of the following capacities of DG sets (a) DG Set of capacity 100 KVA to 85 KVA
(b) DG Set of capacity 45 KVA to 63 KVA
(c) DG Set of capacity 15 KVA to 40 KVA
M & L for de-scaling of radiator assy by disconnecting and removing from eingine, opening the top & bottom chambers, descalling the sediments and scales, corrosion etc and cleaning the core pipes with cleaning chemicals (radi wash) and high pressure water washing and arresting the leakage in core, if any, by brazing / dummy with lead, compressed air cleaning, reassembling the same with new gasket, and fixing to the engine with new hose pipe and clipes as reqd and filling radiator coolent complete all as directed for 100 KVA to 85 KVA capacities DG sets :- Note : The rate qouted shall be inclusive of transporting of the radiator to the workshop and back and all incidental charges. The coolant required for filling will be measured and paid seperately under respective item of this schedule.
All same as per item No 134 here-in-above but DG Set of capacity 45 KVA to 63 KVA
All same as per item No 134 here-in-above but DG Set of capacity 15 KVA to 40 KVA
Taking out old unserviceable radiator from the engine and supply and fixing of radiator of same type and size and connecting coolant hose pipes for inlet and outlet etc and refilling new coolant and testing complete for 63-45 KVA Kirloskar DG set all as directed by Engineer-in-Charge.
Supply only voltage monitering regulator (UV, OV, SP) of suitable ratings for AMF panels
Dismantling/repairing the cylinder head assy of 25 KVA DG Set Kirloskar by stripping out the head assy from engine and carrying out the machining work such as head surfacing pressure testing, valve seat angle facing, lapping replacing the rusted water plugs and fixing the new brass water plugs etc., and replacing the worn out parts like inlet & exhaust valves, guides, valves seat inserts, head gaskets, stem seal, silicon "O" rings and reassembling the engine after replacing following spares and testing to its full efficiency including transportation all as directed (a) Valve (Inlet & Exhaust) - 6 Pair (b) Valve Guide - 8 Nos. (c) Valve seat - 8 Nos. (d) Stem Seal - 8 Nos. (e) Set of copper washer - 1 set (f) Set of O Ring 1 Set (g) Set of gasket - 1 set (h) Copper head casket - 1 Set
Dismantling/repairing the cylinder head assy of 25 KVA DG Set of Kirloskar make by stripping out the head assy from engine and carrying out the machining work such as head surfacing pressure testing, valve seat angle facing, lapping replacing the rusted water plugs and fixing the new brass water plugs etc., and replacing the worn out parts like inlet & exhaust valves guides , valves seat inserts, head gaskets, stem seal, silicon "O" rings and and reassembling the engine after replacing following spares and testing to its full efficiency including transportation all as directed (a) Valves - 8 Nos (b) Valve Guide - 12 Nos. (c) Valve seat - 12 Nos. (d) Stem Seal - 12 Nos. (e) Set of copper washer - 1 set (f) Set of O Ring - 1 Set (g) Set of gasket - 1 set (h) Copper head casket - 4 Nos.
Supply only Voltage Regulator (AVR) suitable for DG set of capacity 100 KVA to 125 KVA
Supply only Voltage Regulator (AVR) suitable for DG set of capacity 45 to 63 KVA
Supply only Voltage Regulator (AVR) suitable for DG set of capacity 40 to 15 KVA
Supply only Low Oil pressure Switch 12 Volt as per the existing switch
Supply only stopping solenoid 12 Volt suitable for the following DG sets : (a) DG Set of capacity 100 KVA to 85 KVA
(b) DG Set of capacity 45 KVA to 63 KVA
(c) DG Set of capacity 15 KVA to 40 KVA
Supply only Banjo bolts of suitable sizes
Supply only fuel tank filter
Supply only anti vibration pad
Supply only Radiator hose flexible suitable for the following DG sets : (a) DG Set of capacity 100 KVA to 85 KVA
(b) DG Set of capacity 45 KVA to 63 KVA
(c) DG Set of capacity 15 KVA to 40 KVA
Supply only Hose plain for water pump suitable for the following : (a) DG Set of capacity 100 KVA to 85 KVA
(b) DG Set of capacity 45 KVA to 63 KVA
(c) DG Set of capacity 15 KVA to 40 KVA
Supply only DC Ammeter of Range 0-10 A
Supply only Lube oil pressure gauge of suitable range
Supply only starter motor assembly for 45/25 KVA, 12 Volt DC
Supply only Air Filter elements of following DG set as given bellow : (a) DG Set of capacity 100 KVA to 85 KVA
(b) DG Set of capacity 45 KVA to 63 KVA
(c) DG Set of capacity 15 KVA to 40 KVA
(b) 100 KVA capacity at TB-IV (North) pump house.
(c) 82.5 KVA capacity at FIU Lab
(d) 63 KVA capacity 598 PH
(e) 45 KVA capacity at VIP NO-2 PH Collage.
(f) 40 KVA capacity at AT RECORD Collage
(g) 30 KVA capacity at 100 Map Domlur
(h) 30 KVA capacity at EME WORKSHOP Collage
(j) 30 KVA capacity at Meeret Block
(k) 25 KVA capacity at PH-NO1 Collage
(l) 25 KVA capacity at TB-IV PH (N)
(m) 20 KVA capacity at 70 MAJ Map Ph
(n) 20 KVA capacity at Domlur Pump House
(o) 15 KVA capacity BAffle Range.Note for Item No. 163 :- i) The rate deemed to be included all the minor spares such as screws, washers, clips etc and all other spares required will be measured and paid seperately under supply only items. ii) General maint shown above are indicative only, contractor has also to do any other maint task required at site as directed by Engr-in-Charge. iii) The contractor has to attend the breakdown calls and depute technician as and when required without any delay to keep the DG set 100% serviceable all the times as directed by Engr-in-Charge.
Filling only Engine Oil 20W-40 all as directed. Note - Engine oil will be issued under Sch 'B' free for fixing only.
Supply only electronic timer for on delay function 12VDC/240VAC with time range 0.3 Sec to 30 Min. Make: EAPL or equivalent suitable for panel.
Supply only relay 12 V DC 8/11pin. Make : PLA or equivalent suitable for panel.
Supply only HRC fuses of capacity 4-20 Amps.
Supply only HRC fuse cartidge assembly both base and top 20 A rating.
Supply only indicator lamps DC 12V LED type
Supply only indicator lamps AC 230 Volt LED type
Supply only push button with contact element 5 A with NO-NC
Supply only Analog Ammeter as per sample of range -/5A CT Operated for control/AMF panel
Supply only Analog Volt Meter as per sample of Range 0-600 Volts AC.
Supply only Frequency meter vibrating reed of Range 45-55 HZ.as per exisisting make
Supply only Frequency meter Digital type LED type of Range 45 Hz -55 HZ. as per exisisting make
Supply and fix in repairs power contactor 4 Pole Existing type 100/85 KVA AMF Panel including disconnecting and removing existing defective item from electric circuit including necessary connected fastners, burnt cables, accessories etc,. all as per site requirement/existing make/model all as specifed and as directed.
All as per item No 190 above but power contactor 4 Pole suitable for 40/63KVA for AMF Panel.
All as per item No 190 above but power contactor 4 Pole 30/20 KVA DG set
All as per item No 190 above but Axilary contactor 4 Pole 100/85 KVA DG set
All as per item No 190 above but type of Axilary contactor 4 Pole suitable for AMF panel of 40/63 KVA DG set
All as per item No 190 above but type of main contactor 4 Pole suitable for AMF panel of 30/15 KVA DG set
S&F in repairs operating coil for contactor suitable 100 to 85 KVA DG sets
S&F in repairs operating coil for contactor suitable 40 to 63 KVA DG sets
S&F in repairs operating coil for contactor suitable 15 to 30 KVA DG sets
S&F Battery charger with primery /secendary volts,Ammeter with step down transformer220v ac to 12/24 v dc suitable for AMF Panels and For Battery charging including hydrometer Make : NHP/equivalentas per site
M&L for repair and servicing of charging alternator / dianamo of DG set of 100/85 KVA DG set after removing from the engine and transporting to an auth service centre, dismantling, removing unsv parts like diode, bush/bearing, carbon brush etc, cleaning reassembling with new parts as required and refitting to the engine and testing complte all as directed.
All as per item No.200 here-in-before but capacity of DG set 40 to 63 KVA
All as per item No.200 here-in-before but capacity of DG set of 15 KVA to 30 KVA
Supply only ignition key suitable for DG set panel/control panel.
M&L for repair / overhauling of self starter assembly 12 Volts of DG Set 100/85 KVA by disconnecting and removing from the engine, cleaning all accessories, replace the wornout parts like bendix drive, brushes, bushes, contact plates, jumping leads and seals, re-varnishing the field coil, armature and reassembling the same, refitting to the engine and testing complete all as directed .
M&L for repair / overhauling of self starter assembly 12 Volts of DG Set of 40 KVA to 63 KVA by disconnecting and removing from the engine, cleaning all accessories, replace the wornout parts like bendix drive, brushes, bushes, contact plates, jumping leads and seals, re-varnishing the field coil, armature and reassembling the same, refitting to the engine and testing complete all as directed .
M&L for repair / overhauling of self starter assembly 12 Volts of DG Set of 15 to 30 KVA by disconnecting and removing from the engine, cleaning all accessories, replace the wornout parts like bendix drive, brushes, bushes, contact plates, jumping leads and seals, re-varnishing the field coil, armature and reassembling the same, refitting to the engine and testing complete all as directed .
Material and labour for repair work to exhaust system including replacing aluminium clading, glass wool wherever necessary and necessary reviting work for the following DG Sets. (a) DG Set of capacity 100 KVA to 85 KVA
(b)G Set of capacity 40 KVA to 63 KVA
(c)DG Set of capacity 15 KVA to 30 KVA
M&L for cleaning throughly and preparing surface by removing rust, dust and oil, and painting of complete for the following DG Set with including acoustic enclosure two coats of existing colour code including control / AMF panel board complete all as specified and directed by Engr-in-Charge. Note:- (i) Painting should be done with existing colour codes and paint should apply with the help of spary gun using air compressor including writing SM/MES Number on prominent places of DG & Alternators. 45/15 KVA capacity (ii) Quotated rate shall deemed to be inclusive of preparation of old painted surface and applying zinc chrome primer in patches over rusted portion all as directed.
Supply and fix in repairs MCCB 3 pole 25 to100 Amps 16 KA in LT panel boards / feeder pillar boxes including disconnecting and removing existing defective item from electric circuit including necessary connected fastners, burnt cables, accessories etc all as per site requirement/existing make/model all as specifed and as directed.
Supply and fix in repairs MCCB 3 pole 125 Amps 25 KA in LT panel boards / feeder pillar boxes including disconnecting and removing existing defective item from electric circuit including necessary connected fastners, burnt cables, accessories etc all as per site requirement/existing make/model all as specifed and as directed.
Supply and fix in repairs MCCB 3 pole 200 Amps 36 KA in LT panel boards / feeder pillar boxes including disconnecting and removing existing defective item from electric circuit including necessary connected fastners, burnt cables, accessories etc all as per site requirement/existing make/model all as specifed and as directed.
supply and fix in repairs change over switch 4 pole 125 A without enclosure in LT panel boards / feeder pillar boxes including disconnecting and removing existing defective item from electric circuit including necessary connected fastners, burnt cables, accessories etc all as per site requirement/existing make/model all as specifed and as directed. Make: L&T, HAVELLS, STANDARD, INDO ASIAN
Supply and fix in repair change over switch 4 pole 125 A with enclosure. out door type for bypass supply all as per site requirement complete all as specifed and as directed. Make : L&T, HAVELLS, STANDARD, INDO ASIAN
Supply and fix in repair change over switch 4 pole 63 A with enclosure. out door type for bypass supply all as per site requirement& all as specifed and as directed.Make : L&T, HAVEL, STANDARD, INDO ASIAN
Supply only microprocessor based AMF controller unit for AMF Panel flush mounting type all as specified. Make - Deep Sea Electronics or equivalent
Fabricate, install and testing in replacement factory made, pole mounted canopy headed single door outdoor type, weather proof totally enclosed street light controlling panel of size 55cm x 50cm x 40cm suitable for 3 phase 4 wire 440 volts made out of 3 mm thick CRCA sheet, cubical type, powder coated paint inside and outside, having front hinged door with neoprene rubber gasket including danger notice board/plate earth terminal point, bottom detachable gland plate with holes for incomming and outgoing cables provision fixing arrangement with clamps made out of Mild Steel flat iron 40X5mm including bolts & nuts, including internal connection by using suitable size copper conductor cable complete with the following accessories:- (a) MCCB, 4 pole, 415 volts, 25 kA, 63 Amps Capacity with thermal load release relay- 1 No (for incoming) (b) Astro type time switch 110-240 volts suitable for 24 hours operation of street light. Make : - L&T/ Legrand/Havells/ABBB (c) Contactor three pole 40 Amps 415 volts coil operating voltage 230 volts. Make L&T MNX 40 or equivalent of Legrand/Havells/ABB (d) Auto manual switch 10 Amps - 02 Nos. Make : - L&T/Legrand/ABB (e) MCB TPN 32 Amps, 10 KA, 'C' curve - 02 Nos
Supply, fabrication, installation and testing of LT out door type factory made(CPRI Approved ), junction box of size 900mm(H)X700mm(B)X400mm(W) (over all dimension ) made out of 3.0mm thick CRCA sheet dully supported with mild steel angle iron of size 40X40X5 mm frame, 04 Nos aluminium bus bar of of capacity 250 Amps with drilled hole for incoming/outgoing cable connection with necessary aluminium lungs, GI nuts bolts and washer including 08 Nos bridge insulator DMC , heavy duty, suitable for 3 Phase 4 wire system, one danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white with letters, figures and conventional skull & bones in signal red colour and fixed in front door size and PCC (1:3:6) type C-1 foundation 0.30m above normal ground level & 0.30m below ground level with necessary exacavation and earth work and painting to internal and external steel surface with powder coated (Siemence grey) RL-35 after neccesary preparation of surfaces including providing indicating lamp LED type 240V 50 Hz AC -one set of 3 Make: L&T/Legrand/ ABB/Siemens/Havells complete all as directed.
(m) LED drive 240 volt 60 / 80 watt for street light as per existing model complete all as directed.(Note : The subject item is operative for item No 29 here-in-above)
M/S Jaiprakash Electrical and Engineering Works
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .