Tender Value
₹25.5 L
EMD Value
₹51,100
Closing Date
18 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I RND DELHI
MILITARY ENGINEER SERVICE, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
REPAIR/MAINT/UPGRADATION METERING SYSTEM AUXILIARY SUPPLY ALONGWITH ANALYZATION OF EXISTING ELECTRICAL/MECHANICAL SYSTEM AT KWC AND METCALFE HOUSE UNDER GE I RND DELHI
2023_MES_633906_1
GE/RND-96/DLI/2023-2024
Open Tender
Civil Works
Item Rate
240 days
DELHI
Class-D, Cat-b(ii), d(iv)
2 documents required · 2 mandatory
₹500
GE I RND DELHI
₹51,100
Yes
21 Feb 2024
21 Dec 2023
20 Jan 2024
21 Dec 2023
18 Jan 2024
4 Jan 2024
Amount
Dismantling of old U/S faulty analyzer’s or correctors of any make /Type and Supply, installation, testing and commissioning of accurate power factor correction cum protection device 3 phase 4 wire desirable` steps as per site conditions with following specifications Base accuracy: ±3% (of maximum scale value) Adjustment accuracy: ±5% (of maximum scale value) Repetition accuracy: Ambient temperature: -25 to +55°C (according to IEC 68-1) -25 to +40°C (according to UL 508) Storage temperature: -25 to +70°C Transport temperature: -25 to +70°C Relative humidity: 15% to 85% (according to IEC 721-3-3 class 3K3) Pollution degree: 3 (according to IEC 664-1)Protection against power factor of the electrical system close to unity, with technical feature mentioned below Power factor monitor of minimum threshold ϕ1 and maximum monitoring of threshold ϕ2 with programmed output contacts either in on-position if fault occurs (normal open .) or in off-position if fault occurs (normal close .) Time ranges Adjustment range Start-up suppression time: 3s 3min Tripping delay: 1s 40s. Input circuit Supply voltage: 230V AC terminals Tolerance: 230V AC ±10% . Rated frequency: 48 to 63Hz Rated consumption: 230V AC 3VA (2W) Duration of operation: 100% Reset time: 500ms Residual ripple for DC: - Drop-out voltage: >30% of the supply voltage Insulation voltage: 415V AC (according to IEC 664-1) Surge voltage: 4kV, overvoltage category III (according to IEC 664-1). 2 potential free change over contacts Switching capacity (distance < 5mm): 1250VA (5A / 250V AC) Switching capacity (distance > 5mm): 2000VA (8A / 250V AC) Fusing: 8A fast acting Mechanical life: 40 lakh operations Electrical life: 20 lakh operations at 1000VA resistive load Switching frequency: max. 60/min at 100VA resistive load max. 6/min at 1000VA resistive load (according to IEC 947-5-1) Insulation voltage: 250V AC (according to IEC 664-1) Surge voltage: 4kV, overvoltage category III (according to IEC 664-1). . Measuring circuit Input: voltage terminals Voltage range: 1-phase mains 24 to 400V AC 3-phase mains 3(N)~ 24 to 440V Overload capacity: 1~ 400V AC 440V AC 3(N)~ 440V 3(N)~ 500V Current range: 1 to 16A Overload capacity: 18A (90A max. 1s) Input resistance: Protection at power failure to Close the capacitor bank and should not and due to sudden variation in the load the power factor shoots above unity Auto shut down panel or switching off extra Capacitors in Delta Mode factor condition. be re-energized till it discharges to a safe value of 50 volts or less, relay should be instantaneous type with low voltage setting Spikes/Surge protection to trip the capacitor bank at overloading due to over voltage or harmonic current. over current relay tripping protection of the bank against system disturbances and faults protection of the bank against faults occurring within the bank including protection of the bank against faults occurring within the bank Timer for re-energization after 5 minutes: protection to block the re-switching of capacitor bank in less than 5 minutes. including with following specifications 3 phase 4 wire 3 Current Transformers resin cast 15 VA burden 1100 volts insulation FUNCTION Limit the Inrush Current, Improve the THD/PF at Light Load or High Line, Improved Stability with a Type 2 Compensation Network--Phase Unbalance, Auto Phase Reversal tripping suitable for existing APFC Panels , Phase Missing Under Voltage and Over Voltage Monitor and Control, Neutral Open Protection. ALSO SPECIAL ZERO CROSSING SWITCHING OPERATION PROTECTION SYSTEM DIGITAL DISPLAY OF LINE PHASE VOLTAGES AND LINE CURRENT INCLUDING FREQUENCY Phase Un balance (1 to 20%) (Adjustable) Power consumption 15VA / 3W Setting Accuracy voltage ± 4V, Minimum setting current 0.5A, Maximum setting current =5A (Above 5A - external CT setting max.1000/5 in steps of 5), Setting Accuracy Current ± 5% of full scale ±1digit, Trip time delay1 to 250secs settable for Unbalance, Overvoltage, Undervoltage ( Line to Line & Line to Neutral ) , Undercurrent & Overcurrent, Trip time accuracy± 1% of set delay ±2sec., Trip setting, Phase failure 3 sec Max. factory set., Phase Reversal Auto tripping, Phase Un balance1 to 20% (Adjustable), Under Voltage and over voltage 5V to 60V AC (Adjustable Individually ), Recovery Time2 sec Min Power On Delay10 sec Max., Service life(under no load) 10Lakh operations minimum , Electrical life, (under full load) 10 Lakh operations minimum PROTECTION SYSTEM SHOULD BE PROVIDED WITH EACH FAULT DIGITAL DISPLAY, Compensation of each phase, Measure power factor , total watts, total VAr, total KWH, Total KVArh, Programmable THD protection, Programmable Discharge Time MAKE SIEMENS /L&T/ BCH/ABB/ SCHNIDER Minimum ISO 9001:2015 Certified Note :- The Entire work at site is to be executed only by OEM approved by GE complete all as specified and directed at Site. The Contractor has to submit Original Purchase Vouchers, Test Certificates & Guarantee Certificate from OEM before installation at site
Dismentaling of old damaged burnt fuse kit kat assembly and replace with Supply instalation testing and commissioning of Surge voltage arrester Lightning and Surge Current Counter & SPD monitoring device Wide surge current detection range: 0.3/50 kA @8/20µs ,0.3/25 KA @10/350µs ,Front display for access to recorded events and device parameters ,Peak current and time stamping recording of the surge currents RS485 communication interface / MODBUS protocol , Monitoring features : 2 inputs (SPD or disconnector status) / 1 ouput, IEC 62561-6 compliance consisting of base element with remote indicator contact and ground connectors, for mounting on NS 35/7.5, nominal voltage: 230 V AC, 3 + 1 circuit protection With floating remote indication contact Multi-channel type 2 arresters Optical, mechanical status indication for the individual arresters Type 2 consistent plug-in surge arresters Mechanical coding of all slots Disconnect device on each individual plug , Ambient temperature (operation) -40 °C ... 80 °C Ambient temperature (storage/transport) -40 °C ... 80 °C Altitude ≤ 2000 m (amsl (above mean sea level)) Permissible humidity (operation) 5 % ... 95 % Shock (operation) 25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) Vibration (operation) 5g (10 ... 500 Hz / 2.5 h / X, Y, Z) General IEC test classification II T2 EN type T2 IEC power supply system TN-S TT Mode of protection L-N L-PE N-PE Mounting type DIN rail: 35 mm Color jet black RAL 9005 Housing material PA 6.6 PBT Degree of pollution 2 Flammability rating according to UL 94 V-0 Type DIN rail module, two-section, divisible Number of positions 4 Surge protection fault message Optical, remote indicator contact Protective circuit Nominal voltage UN 240/415 V AC (TN-S) 240/415 V AC (TT) Nominal frequency fN 50 Hz (60 Hz) Maximum continuous operating voltage UC (L-N) 275 V AC Maximum continuous operating voltage UC (L-PE) 275 V AC Maximum continuous voltage UC (N-PE) 260 V AC Rated load current IL 80 A Residual current IPE ≤ 5 µA Standby power consumption PC ≤ 360 mVA Nominal discharge current In (8/20) µs 20 kA Maximum discharge current Imax (8/20) µs 40 kA current interrupt rating Ifi (N-PE) 100 A Short-circuit current rating ISCCR 25 kA Voltage protection level Up (L-N) ≤ 1.35 kV data Protective circuit Voltage protection level Up (L-PE) ≤ 1.6 kV Voltage protection level Up (N-PE) ≤ 1.5 kV Residual voltage Ures (L-N) ≤ 1.35 kV (at In) ≤ 1.1 kV (at 10 kA) ≤ 1 kV (at 5 kA) ≤ 0.9 kV (at 3 kA) Residual voltage Ures (L-PE) ≤ 1.6 kV (at In) ≤ 1.2 kV (at 10 kA) ≤ 1 kV (at 5 kA) ≤ 0.9 kV (at 3 kA) Residual voltage Ures (N-PE) ≤ 0.4 kV (at In) ≤ 0.25 kV (at 10 kA) ≤ 0.15 kV (at 5 kA) ≤ 0.1 kV (at 3 kA) TOV behavior at UT (L-N) 335 V AC (5 s / withstand mode) 440 V AC (120 min / safe failure mode) TOV behavior at UT (N-PE) 1200 V AC (200 ms / withstand mode) Response time tA (L-N) ≤ 25 ns Response time tA (L-PE) ≤ 100 ns Response time tA (N-PE) ≤ 100 ns Max. backup fuse with V-type through wiring 80 A (gG) Max. backup fuse with branch wiring 125 A (gG) Indicator/remote signaling Switching function PDT contact Operating voltage 5 V AC ... 250 V AC 30 V DC Operating current 5 mA AC ... 750 mA AC 1 A DC Connection method Plug-in/screw connection via COMBICON Screw thread M2 Tightening torque 0.25 Nm Stripping length 7 mm Conductor cross section flexible 0.14 mm² to 1.5 mm² Conductor cross section solid 0.14 mm² to 1.5 mm² Conductor cross section AWG 28 ... 16 Connection data Connection method Screw connection. Make CITEL/ABB/SCHNEIDER/PHONIX The entire work is to be executed by OEM only approved by GE. The Contractor has to submit Original Purchase Vouchers, Test Certificates & Guarantee Certificate from OEM before installation at site.
M/S Sonu Traders
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .