Loading…
Loading…
Tender Value
₹2.9 Cr
EMD Value
₹5.8 L
Closing Date
10 Jul 2026, 1:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
NIT
15 conditions · 4 needing a document upload
As per PREAMBLE CLAUSE No. 11.2 of Tender Document:- The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees, N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure- VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
ELECTRICAL CONTRACTORS LICENSE:- The contractor shall fulfill valid Electrical Contractor License requirement as per IE Rule 1956 clause no- 45. Electrical Contractors license shall be submitted along with the offer, failing which the offer will summarily be rejected.
Technical Eligibility Criteria: As per clause 11.1 of Preamble and Scope of Work of uploaded tender document Page no. 4 & 6.
SIMILAR NATURE OF WORK: The contractor should have executed, "Electrification / Rewiring of Service or Residential building/Yard / HT/LT Substation work / HT/LT cable work / Street lighting / Platform or building lighting management / circulating area Lighting/ Electrical overhead power supply work / Electrical pump work etc."
23 conditions · 9 needing a document upload
All the supporting DOCUMENT(S)/CERTIFICATE(S) of as a proof Technical and Financial credentials as detailed in this tender Document, has/have been attached.
Supporting DOCUMENTS/CERTIFICATES as detailed in this Tender Document has been attached.
The Bid Security shall be deposited either in cash through epayment gateway or submitted as Bank Guarantee bond from a scheduled commercial bank of India or as mentioned in tender documents. The Bank Guarantee bond shall be as per Annexure- VIA and shall be valid for a period of 90 days beyond the bid validity period. The original Bank Guarantee should be delivered in person to the official nominated as indicated in the tender document before closing date for submission of bids. (i.e. excluding the last date of submission of bids.) (See clause 1.10 of Chapter-I of Tender Document)
All the bidders / tenders should ensure that they are GST compliant and their quoted tax structure / rates are as per GST Law. (Copy of GST registration certificate)
Copy of PAN CARD
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
(A) Electrification for upgradation of SM office, other utility offices, construction and improvement of toilet, beautification of FOBs and allied works at Thakurli station. (B) Rewiring for renovation and improvement of service buildings in between Kanjurmarg-Kopar Section. (C) Rewiring for renovation and improvement of service building at Thakurli, Dombivli and Kalyan Station. (D) Electrification for Provision of extension of platform at Vikhroli, Kalva, Mumbra & Diva of through lines for running of 15 car EMU services.
BB-LG-W-THK-2026-01
BB-LG-W-THK-2026-01
Open
Works - General
12 Months
Mumbai, Maharashtra
₹0
₹5.8 L
10 Jul 2026
18 Jun 2026
26 Jun 2026
273 items across 7 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,19,25,739.93 | ||
| details. | Item Breakup for | — | — | ||
| (1) Supply, erection, testing and commissioning of 2 x 18 W LED fitting complete with connection and necessary fixing arrangements as per site requirement. | — | — | — | 6,92,097 | |
| details. | Item Breakup for | — | — | ||
| (2) Supply, erection, testing and commissioning of 18-20 W 4 feet LED slim fitting complete with connection as per site requirement | — | — | — | 2,13,562 | |
| details. | Item Breakup for | — | — | ||
| (3) Supply, erection, testing and commissioning of 9-10 W LED (2 ft) slim fitting complete with fixing arrangement, etc. | — | — | — | 26,400 | |
| details. | Item Breakup for | — | — | ||
| (4) Supply, erection, testing and commissioning of 2 x 2 36 W LED fitting with IP 20 complete with connection and necessary fixing arrangements as per site requirement. | — | — | — | 2,50,118.4 | |
| details. | Item Breakup for | — | — | ||
| (5) Supplying and erecting integrated LED flood light fitting Max. 70-80W including driver with U shaped bracket as per specification | — | — | — | 1,27,880 | |
| details. | Item Breakup for | — | — | ||
| (6) Supply and fixing of 18-20 watts LED round recessed/surface mounted downlighter with a pressure die-cast aluminum heat sink luminaire of, with a supply connection using a 3-core x 1.5 sq.mm PVC insulated copper cable fittings complete with fixing. | — | — | — | 99,420 | |
| details. | Item Breakup for | — | — | ||
| (7) Supply, fixing, testing & commissioning of LED 15-20W, spot light fitting, Effective heat dissipation with extruded aluminum heat sink, inbuilt protection, protected from dust and insects, complete with cover/ other accessories etc. with aluminum housing powder coated with white reflector, and necessary fixing arrangements as per site requirement. | — | — | — | 69,081.6 | |
| details. | Item Breakup for | — | — | ||
| (8) Supply, erection, testing and commissioning of timer panel board as per railway's requirement | — | — | — | 1,58,182.64 | |
| details. | Item Breakup for | — | — | ||
| (9) Supply, erection, testing and commissioning of LED mirror light for washing basin, complete with accessories | — | — | — | 77,190 | |
| details. | Item Breakup for | — | — | ||
| (10) Supply, erection, testing and commissioning of LED strip 5 meters light complete with all fixing arrangements. | — | — | — | 1,20,509.6 | |
| details. | Item Breakup for | — | — | ||
| (11) Supply, erection, testing and commissioning of Aluminium LED profile complete with all fixing arrangements. | — | — | — | 80,960 | |
| details. | Item Breakup for | — | — | ||
| (12) Supply, erection, testing and commissioning of 85-90W LED outdoor lighting fitting complete with all fixing arrangements. | — | — | — | 4,03,560 | |
| details. | Item Breakup for | — | — | ||
| (13) Supply, fixing, testing and commissioning of heritage type pole with post top weather proof LED light fitting complete with all accessories and cement concrete foundation | — | — | — | 5,35,988.4 | |
| details. | Item Breakup for | — | — | ||
| (14) Supply, erection, testing & commissioning of LED Bollard 10-15W fitting complete with connection and necessary fixing arrangements as per site requirement. | — | — | — | 4,76,950.8 | |
| details. | Item Breakup for | — | — | ||
| (15) Supply, erection, testing and commissioning of LED decorative wall light fitting complete with all fixing arrangements. | — | — | — | 96,035.4 | |
| details. | Item Breakup for | — | — | ||
| (16) Supply, erection, testing and commissioning of 48" sweep energy efficient BLDC ceiling fan with down rod, motor, etc. with necessary connection. | — | — | — | 2,96,157 | |
| details. | Item Breakup for | — | — | ||
| (17) Supply, erection, testing and commissioning of exhaust fans 9" metal body with motor guard, cover, etc | — | — | — | 47,628 | |
| details. | Item Breakup for | — | — | ||
| (18) Supply, erection, testing and commissioning of 12" metal body type exhaust fan complete with motor guard, cover, etc. | — | — | — | 26,770.32 | |
| details. | Item Breakup for | — | — | ||
| (19) Supply, erection, testing and commissioning of Air circulator (BLDC) wall mounted 24" sweep fan with necessary connection | — | — | — | 6,61,967.2 | |
| details. | Item Breakup for | — | — | ||
| (20) Supply, erection, testing and commissioning of 16" sweep wall bracket fan complete with necessary fixing arrangement | — | — | — | 31,661 | |
| details. | Item Breakup for | — | — | ||
| (21)Wiring of the concealed Light / fan / call bell point with all accessories. The switches shall be of modular type. | — | — | — | 2,56,612.5 | |
| details. | Item Breakup for | — | — | ||
| (22) Wiring of the Universal plug point on switch board with all accessories and running earthing copper conductor as per standard practice. The switches shall be of modular type. | — | — | — | 15,145.5 | |
| details. | Item Breakup for | — | — | ||
| (23) Wiring of the concealed Universal plug point on separate switch board with all accessories. The switches shall be of modular type. | — | — | — | 22,906.1 | |
| details. | Item Breakup for | — | — | ||
| (24) Wiring of the concealed 5A/ 5-Pin Universal plug point (4 plug & 4 switch on separate board) with all accessories. The switches shall be of modular type. | — | — | — | 67,675.2 | |
| details. | Item Breakup for | — | — | ||
| (25) Wiring of concealed 15 Amps 6 pin wall socket point complete on separate switch board with 20 Amp DP MCB & all accessories and running earthing copper conductor as per standard practice. The switches shall be of modular type. | — | — | — | 30,794.7 | |
| details. | Item Breakup for | — | — | ||
| (26) Supply, laying, running fixing of following sizes of XLPE insulated, PVC sheathed, 1.1 KV grade cables as per IS. (a) 4 core 50 sq.mm AL conductor, armoured (b) 4 core 16 sq.mm AL conductor armoured (c) 4 core 10 sq.mm AL conductor armoured (d) 3 core 06 sq.mm AL conductor, armoured (e) 4 core 10 sq.mm CU conductor, armoured | — | — | — | 18,56,700 | |
| details. | Item Breakup for | — | — | ||
| (27) Excavation of cable trench in soil & filling the trench with sand, pebbles etc. after laying of the cable complete with RCC warning cover & cable markers, sand etc. as per railways requirement | — | — | — | 44,739.5 | |
| details. | Item Breakup for | — | — | ||
| (28) Excavation of cable trench on CC flooring / Hard / rocky soil & making of trench & recasting of flooring/pit after lying of cable as per railways requirement. | — | — | — | 66,445 | |
| details. | Item Breakup for | — | — | ||
| (29) Supply, erection, testing and commissioning of 2 KVA UPS with battery backup as per Railway specification | — | — | — | 1,83,447 | |
| details. | Item Breakup for | — | — | ||
| (30) Supply, erection, testing and commissioning of LT Distribution Panel Board comprising of 100-125 Amp FP MCCB 36kA Microprocessor based release 02 nos, RCBO 4 Pole, 32 Amp 415V 50Hz 10kA Sensitivity-300 mA - 4 nos, RCBO 4Pole 63 Amp 415V 50Hz 10kA Sensitivities- 300 mA - 6 nos. as outgoing complete with busbars, neutral link, etc. as per site requirement | — | — | — | 2,94,536.46 | |
| details. | Item Breakup for | — | — | ||
| (31) Supply, erection, testing and commissioning of maintenance free earthing | — | — | — | 63,225.15 | |
| details. | Item Breakup for | — | — | ||
| (32) Supply, erection, testing and commissioning of FRP junction box as per Railway's requirement. | — | — | — | 3,69,830.25 | |
| details. | Item Breakup for | — | — | ||
| (33) Supply and laying of HDPE pipe of size 4" dia | — | — | — | 99,330 | |
| details. | Item Breakup for | — | — | ||
| (Thirty Four) Supply and fixing of GRP / FRP cable tray made of glass fiber reinforced polyester moulding composite material, size 200mm width x 75mm depth min., 04mm thick min., including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with GI suspenders etc | — | — | — | 4,45,866 | |
| details. | Item Breakup for | — | — | ||
| (35) Design, fabrication, Supply, multiple loading/ unloading, storing installation, fixing, testing & commissioning LT Distribution / Panel board having thermal magnetic MCCB's 250A 4P 36 kA breaking capacity - 1 No. a incomer and 100 A 4P 16 kA break in capacity - 1 Nos, 63A 4P 16kA breaking capacity - 4 Nos. as outgoing with, Rotary Handle vary Depth, Padlock support for operating Handle, Phase barrier, DPX spreader Links, etc. as required and complete in all respect. | — | — | — | 5,64,680.52 | |
| details. | Item Breakup for | — | — | ||
| (36) Design, fabrication, Supply, multiple loading/ unloading, storing, installation, fixing, testing nos. & commissioning of LT Distribution/ Panel board having thermal magnetic MCCB's 250A 4P 36kA breaking capacity-2 nos. as incomer and automatic change over switch 250 A 36 kA breaking capacity-1No with inbuilt time delay primary protection against single phasing & over voltage, and 200 A 4P MCCB 36 kA breaking capacity - 1 nos., 125 A 4P MCCB 16kA breaking capacity-2 Nos., 100 A 4P MCCB 16 kA breaking capacity-3 Nos. as outgoing with 250A Copper busbar, Rotary Handle vary Depth, Padlock support for operating Handle, Phase barrier, DPX spreader Links, etc. as required and complete in all respect. | — | — | — | 4,37,479.91 | |
| details. | Item Breakup for | — | — | ||
| (37) Design, manufacture, display, installation of wall / hanging / floor mounting type LED illuminated sign / direction boards in elliptical/half elliptical /semi elliptical etc. shape. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2 mm thickness. The text / graphics matter visibility shall not be less than 160 deg. The approved colour text and graphics shall be printed / router cut on monomeric calendared vinyl of 70 µM thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 6- 8 W / sq. ft and with brightness more than ambient light. Suitable size end cap of 1.5 mm thick SS 304 should be provided. | — | — | — | 23,91,172.5 | |
| details. | Item Breakup for | — | — | ||
| (Thirty Eight) Supply of aluminum folding ladder 10 feet | — | — | — | 7,250 | |
| details. | Item Breakup for | — | — | ||
| (Thirty Nine) Design, supply, erection, testing and commissioning of LED station name board with Individual English letter | — | — | — | 26,687.76 | |
| details. | Item Breakup for | — | — | ||
| (40) Design, supply, erection, testing and commissioning of LED station name board with Individual Devnagari letter for Hindi & Marathi. (Unit is read as letter) | — | — | — | 60,717.02 | |
| (41) Supply & erection of earthing G.I. pipe with cement concrete earth chamber, charcoal, salt, etc. | details. | Item Breakup for | — | — | |
| details. | Item Breakup for | — | — | ||
| (42) Supply, erection, testing and commissioning of GI strip of 25 mm x 5mm | — | — | — | 53,947.5 | |
| — | — | — | 55,13,744.48 | ||
| details. | Item Breakup for | — | — | ||
| (1) Supply, erection, testing and commissioning of 70-75W LED outdoor lighting fitting complete with all fixing arrangements. | — | — | — | 2,87,650 | |
| details. | Item Breakup for | — | — | ||
| (2) Supply, erection, testing and commissioning of 2 x 2 36 W LED fitting with IP 20 complete with connection and necessary fixing arrangements as per site requirement. | — | — | — | 6,25,296 | |
| details. | Item Breakup for | — | — | ||
| (3) Supply, erection, testing and commissioning of 18-20 W 4 feet LED slim fitting complete with connection as per site requirement | — | — | — | 6,59,977.3 | |
| details. | Item Breakup for | — | — | ||
| (4) Supply, erection, testing and commissioning of 9-10 W LED (2 ft) slim fitting complete with fixing arrangement, etc. | — | — | — | 88,000 | |
| details. | Item Breakup for | — | — | ||
| (5) Supply, erection, testing and commissioning of decorative wall light fitting complete with all fixing arrangements. | — | — | — | 1,61,177 | |
| details. | Item Breakup for | — | — | ||
| (6) Supply, erection, testing and commissioning of 48" sweep energy efficient BLDC ceiling fan with down rod, motor, etc. with necessary connection. | — | — | — | 8,38,365 | |
| details. | Item Breakup for | — | — | ||
| (7) Supply, erection, testing and commissioning of exhaust fans 9" metal body with motor guard, cover, etc | — | — | — | 42,525 | |
| details. | Item Breakup for | — | — | ||
| (8) Supply, erection, testing and commissioning of 12" metal body type exhaust fan complete with motor guard, cover, etc. | — | — | — | 55,771.5 | |
| details. | Item Breakup for | — | — | ||
| (9) Wiring of the concealed Light / fan / call bell point with all accessories. The switches shall be of modular type. | — | — | — | 3,71,803 | |
| details. | Item Breakup for | — | — | ||
| (10) Wiring of light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core etc. | — | — | — | 4,42,926 | |
| details. | Item Breakup for | — | — | ||
| (11)Wiring of the 5A/ 5-Pin Universal plug point (4 plug & 4 switch on separate board) in PVC casing / capping. The switches shall be of modular type. | — | — | — | 1,44,027 | |
| details. | Item Breakup for | — | — | ||
| (12) Wiring of 15 Amps 6 pin wall socket point complete all accessories and running earthing as per standard practice on separate board. The switches shall be of modular type | — | — | — | 82,236 | |
| details. | Item Breakup for | — | — | ||
| (13) Supply, laying, running fixing of following sizes of XLPE insulated, PVC sheathed, 1.1 KV grade cables as per IS. (a) 4 core 50 sq.mm AL conductor, armoured (b) 4 core 25 sq.mm AL conductor, armoured (c) 2 core 6 sq.mm Cu conductor armoured | — | — | — | 7,20,000 | |
| details. | Item Breakup for | — | — | ||
| (14) Excavation of cable trench in soil & filling the trench with sand, pebbles etc. after laying of the cable complete with RCC warning cover & cable markers, sand etc. as per railways requirement | — | — | — | 31,430 | |
| details. | Item Breakup for | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC_April-2022upto11ACS.pdf
ATTACHMENT
MaintenancefreeearthingRDSO.pdf
ATTACHMENT
BLDCceilingfanspecification.pdf
ATTACHMENT
CheckList.pdf
ATTACHMENT
GuidelinesonStandardSignagesatStationsonIndianRailwaysPart-1.pdf
ATTACHMENT
GuidelinesonStandardSignagesatStationsonIndianRailwaysPart-2.pdf
ATTACHMENT
TenderBookofTHK.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .