Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.4 LAdmitted-Finance RZ 140 A EAST SAGARPUR STREET NO 7 8 NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L1 | Admitted-Finance | |
| 2 | L2₹17.5 L+₹3,142.80 (0.18%)Admitted-Finance M 78 GARU HARKISHAN NAGAR PASCHIM VIHAR NEW DELHI 110087 | NEW DELHI | WEST DELHI | DELHI | 110087 | L2 | Admitted-Finance | |
| 3 | L3₹18.3 L+₹85,530.40 (4.91%)Admitted-Finance D 662 WZ 1598 R 1 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Admitted-Finance | |
| 4 | Rejected-Technical | - | Rejected-Technical Adverse remarks in CEDZ QE Mar 2026 |
| Sl No | Description | Qty | Unit | Deven Associates L1 | SALUJA CONSTRUCTION CO L2 | SHIVA ENTERPRISES L3 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exc. 1.5 m wide and not exceeding 1.5 mtr deep for pipe line in soft/loose soil getting out and levelling of bottom surface to required level complete all as specified and directed. | 276 | CUM | 129 ₹35,604 Lowest | 200 ₹55,200 | 199 ₹54,924 |
| 2.00 | Excavation over area for each additional 1.5 m or part thereof in depth beyond the first 1.5 m in depth including getting out in soft/loose/hard soil complete all as specified and directed. | 110 | CUM | 149 ₹16,390 | 120 ₹13,200 Lowest | 299 ₹32,890 |
| 3.00 | Returning filling including spreading, leveling, watering and well ramming in layers not exc. 25 cm thick all as specified and directed by Eng. In Charge. | 211.8 | CUM | 29 ₹6,142.2 | 25 ₹5,295 Lowest | 99 ₹20,968.2 |
| 4.00 | Removal of excavated material from site to a distance not exceeding 50 meters away and depositing where directed at a level not exceeding 1.5 meters above the starting point as directed by Engr-in-Charge. | 164.4 | CUM | 59 ₹9,699.6 Lowest | 200 ₹32,880 | 150 ₹24,660 |
| 5.00Supply and fixing PP-R pipe 3 layer PP-R (Polypropylene random copolymer) concealed pipe SDR 7.4 (PN 16) UV stablised and antimicrobial fusion welded having thermal stability for hot and cold water supply including all PP-R plain & brass threaded polypropylene random (PPR) fitting complete to walls, ceiling or floor or laid in trenches of following sizes complete all as specified and directed by Engineer-in-Charge. Note :- PP/PE saddle of any size as required at site for distribution network shall deemed to be included in this item of BOQ. | ||||||
| 5.01 | 20 mm bore | 20 | RM | 49 ₹980 Lowest | 300 ₹6,000 | 150 ₹3,000 |
| 5.02 | 25 mm bore | 500 | RM | 79 ₹39,500 Lowest | 350 ₹1,75,000 | 199 ₹99,500 |
| 5.03 | 63 mm bore | 330 | RM | 469 ₹1,54,770 | 600 ₹1,98,000 | 399 ₹1,31,670 Lowest |
| 5.04 | 110 mm bore | 600 | RM | 1,299 ₹7,79,400 | 1,000 ₹6,00,000 | 999 ₹5,99,400 Lowest |
| 6.00 | M&L Boring holes under road pavement by bocky manually in any type of soil upto 200 mm bore complete all as specified and directed by Engr-in-Charge. | 30 | RM | 249 ₹7,470 Lowest | 500 ₹15,000 | 899 ₹26,970 |
Tender Value
₹19.4 L
EMD Value
₹38,771
Closing Date
21 Aug 2026, 6:00 pmClosed
GE U WATER SUPPLY DELHI CANTT 10
GE U WATER SUPPLY DELHI CANTT 10
PROVN OF STP TREATED WATER IN P9 P11 P15 AND P17 ARUN KHETRAPAL MARG AND CONSTRUCTION OF RAIN WATER HARVESTING RWH PIT AT DELHI AREA PROVEST UNIT UNDER GE U WATER SUPPLY DELHI CANTT 10
2026_MES_780561_1
GE/WS/Token No-40 OF 2026-27
Open Tender
Civil Works
Item Rate
180 days
GE U WATER SUPPLY DELHI CANTT 10
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE U WATER SUPPLY DELHI CANTT 10
₹38,771
Yes
5 Oct 2026
24 Jul 2026
24 Aug 2026
24 Jul 2026
21 Aug 2026
8 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches not exc. 1.5 m wide and not exceeding 1.5 mtr deep for pipe line in soft/loose soil getting out and levelling of bottom surface to required level complete all as specified and directed. | 276 | CUM | 23 | ₹6,348 |
| 2 | Excavation over area for each additional 1.5 m or part thereof in depth beyond the first 1.5 m in depth including getting out in soft/loose/hard soil complete all as specified and directed. | 110 | CUM | 24 | ₹2,640 |
| 3 | Returning filling including spreading, leveling, watering and well ramming in layers not exc. 25 cm thick all as specified and directed by Eng. In Charge. | 211.8 | CUM | 22 | ₹4,659.6 |
| 4 | Removal of excavated material from site to a distance not exceeding 50 meters away and depositing where directed at a level not exceeding 1.5 meters above the starting point as directed by Engr-in-Charge. | 164.4 | CUM | 23 | ₹3,781.2 |
| 5 | Supply and fixing PP-R pipe 3 layer PP-R (Polypropylene random copolymer) concealed pipe SDR 7.4 (PN 16) UV stablised and antimicrobial fusion welded having thermal stability for hot and cold water supply including all PP-R plain & brass threaded polypropylene random (PPR) fitting complete to walls, ceiling or floor or laid in trenches of following sizes complete all as specified and directed by Engineer-in-Charge.
Note :- PP/PE saddle of any size as required at site for distribution network shall deemed to be included in this item of BOQ. | - | - | - | - |
| - | 20 mm bore | 20 | RM | 24 | ₹480 |
| - | 25 mm bore | 500 | RM | 25 | ₹12,500 |
| - | 63 mm bore | 330 | RM | 26 | ₹8,580 |
| - | 110 mm bore | 600 | RM | 27 | ₹16,200 |
| 6 | M&L Boring holes under road pavement by bocky manually in any type of soil upto 200 mm bore complete all as specified and directed by Engr-in-Charge. | 30 | RM | 28 | ₹840 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
BOQ_874364.xls
BOQ • 0.47 MB
tender.pdf
Tender Documents • 0.76 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .