Loading…
Loading…
Tender Value
₹1.7 Cr
EMD Value
₹3.5 L
Closing Date
22 Jul 2026, 3:00 pm
Upgradation of Pit lights and yard lighting arrangements with associated wiring and cabling work at Tikiapara Coaching Yard and Sorting yard Coaching complex.
EL-HWH-25-21-3622-R
EL-HWH-25-21-3622-R
Open
180 Days
Murshidabad, West Bengal
₹0
₹3.5 L
29 Jun 2026
29 Jun 2026
8 Jul 2026
A- Upgradation of Pit lights and yard lighting arrangements with
Supply of Pit Light luminaire of 18-22 Watt LED ( Type of LED - Surface Mounting Device ), pressure die cast housing with Ingress Protection - IP67 or higher ( LED make-Nichia, 1 Osram, Seoul, Philips, Lumileds, Avago, Cree ) complete with all accessories. LED luminaire Efficacy - Minimum 130 Lumens per Watt, Impact Resistance : IK-10 or higher, Color temperature : 5700K, Driver Surge Protection minimum 4KV, Life span of LED chip - Greater than 50000 burnings hours with 60 months warranty suitable for operation on 1Ph, 48V AC, 50 Hz supply system as per site condition. ( Make : Philips (Signify) / Havells / Bajaj / Halonix / Panasonic / Lighting Technologies / Magik / Jaquar / Crompton ) Above/
Fixing, connection, testing and commissioning of above Pit Light luminaire along with 2 nos. Fastner FRP Board and connection with water proof (IP 67 or higher) cable gland, termination and necessary copper cable etc. Above/
Wiring of Light point by 4 nos. single core HRFR / FRLS grade, PVC insulated, copper 3 conductor cable of size 4.0 sq.mm, 1100V grade for three phases and one neutral in GI conduit of 25mm dia along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ). ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) Above/
Conceal wiring on concrete pit wall through PVC pipe of suitable diameter for 4 submain by two nos single core, HRFR/FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm., 1100V grade for phase and neutral along with one single core, HRFR/FRLS grade, PVC insulated, copper conductor cable size 2.5 sq.mm., 1100V grade for Earth Continuty conductor including supply of cable, GI concelled box with modular cover plate, PVC pipe and all other associated work alongwith make good of wall surface as its original condition. ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) Above/
Supply of TPN MCB DB ( Heavy duty, Outdoor type, UV ray protected, self fire- extinguishing and resistant to abnormal heat and fire up to 650 degree C GWT, shock resistance 5 IK08 or above and IP65 degree of protection grade transparent DB box, similar to ABB Mistral65 - 20 Modules or equivalent ), 3Ph, 50Hz, 415V, 4 way per phase, 415V, 50Hz, complete with total 12 nos. SP MCB of current rating from 6A to 32A, 10 kA, 240 Volt, 50Hz per phase as per requirement of load and one no. FP RCBO 63A, 300mA, 10 kA, 415V, 50Hz, Suitable for AC + Pulsating DC (Type A) + Harmonics ( Make of MCB & RCBO - LK (L&T) / Siemens / ABB / Hager Legrand / Schneider ) ( Make of TPN DB - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / Spelsberg / Hensel / Eaton ) Above/
Fixing, connection, testing and commissioning of above TPN MCB DB including all incoming and outgoing cables glanding, cable connection with cable termination and suitable wall hanging arrangement as per site condition with all associated accessories. Above/
Supply of MCB DP, 40A, 1Ph, 240V, 50 Hz, 10kA with polycar- bonate distribution box enclosure (IP-65) with polycarbonate trans- parent openable window including fixing, connection, testing and commissioning. ( Make of MCB - L&T / Siemens / ABB / Hager / Legrand / Schneider and Enclosure Board - Grasp / OBO Bettermann / ABB / Schneider ) Above/
Supply of corrosion resistant, surface mounting, Industrial 20W-40W LED luminaire with PC housing and cover suitable for wet location with Ingress Protection - IP65 or higher complete 8 with 20-40 Watt LED ( Type of LED - Surface Mounting Device ) with industrial grade constant current Driver ( Efficiency - Greater than 85% ) with short circuit protection, ( Make / brand of LED chip - NICHIA, OSRAM, SEOUL, PHILIPS, LUMILEDS, AVAGO, CREE - as per RDSO's functional requirement specification ), LED Efficacy - greater than 100 Lumens per Watt @ 350mA drive current, Life span of LED chip - Greater than 50000 burning hours including all other accessories. ( Make : Philips (Signify) / Havells / Bajaj / Halonix / Panasonic / Lighting Technologies / Jaquar / Crompton ) Above/
Fixing, connection and commissioning of LED luminaire fittings with suitable arrangement. Above/
Wiring of Mainline by 4 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 10 sq.mm, 1100V grade for 03 phases and 01 neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) Above/
Wiring of Light / Fan / Call Bell / Glow Sign point by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral in GI conduit of suitable dia along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ). ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) Above/
Wiring of Light / Fan / Call Bell / Glow Sign point by 2 nos. single core HRFR / FRLS 12 grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for phase and neutral in GI conduit of suitable dia along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ). ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) Above/
Wiring of Light / Fan / Call Bell / Glow Sign point by 4 nos. single core HRFR / FRLS 13 grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for 03 phases and 01 neutral in GI conduit of suitable dia along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ). ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) Above/
Trenching and laying of cable under ground by soil cutting with covering of cable by sand and bricks / through suitable dia HDPE pipe including supply of HDPE pipe (PE-100 grade, PN- 10 or higher) without bricks alongwith refiling of trench by excavated soil and make good of surface as its original condition. ( Cable will be supplied by Railway ) Above/
Trenching, laying under road / track through 50 mm dia GI pipe ( medium gauge ) including supply of GI pipe and commi- ssioning of cable including back filling of trench with excavated soil after laying of cable ( Cable will be supplied by Railway ) Above/
Drawing of cable on wall / structure with suitable size and shape GI clamps including supply of suitable size GI Clamp and GI nut- bolts and commissioning of cable ( Cable will be supplied by Railway ) Above/
Trenching and laying of cable underground by pucca floor / concrete cutting and commissioning of cable through 80mm dia GI pipe including supply of GI pipe alongwith make good of floor surface as its original condition after laying of cable ( Cable will be supplied by Railway ) Above/
Trenching and laying of cable underground by pucca floor / concrete cutting and commissioning of cable alongwith make good of floor surface as its original condition after laying of cable ( Cable will be supplied by Railway ) Above/
Drawing of cable through one no. 2" dia, 3.0 Mtrs. long GI pipe ( Make - Tata / Jindal / Bansal ) for protection of cable on pole with proper GI clamps and GI nuts & bolts including supply of GI pipe ( Cable will be supplied by Railway ) Above/
Supply of FRP Cable Tray ( Perforated ) type ( Width x Collar x Thick ) - 200 mm x 50 mm x 4 mm including fixing, connec- tion, testing and commissioning of above cable tray with necessary arrangement ( Make - RMC Switchgears / Sintex / Fiber Tech Composite / Ferrotech / Grasp / OBO Bettermann ) Above/
Supply of Coupler Plate with S/S 316 Bolts ( Width x Collar x Thick ) - 50 mm x 170 mm x 4 mm of 8 sets including fixing, connection, testing and commissioning of above coupler plate with necessary arrangement ( Make - RMC Switchgears / Sintex / Fiber Tech Composite / Ferrotech / Grasp / OBO Bettermann ) Above/
Supply of Indoor type 5 KVA, AN-dry type distribution transformer with primary 22 voltage 415V AC, 3 phase, 50 Hz, secondary voltage 84V AC [P-P], 48V AC[P-N] 3-phase 50Hz, connection vector group Dyn-11 equiped with incoming MCBs, indication lamp, voltmeter, ammeter alongwith all other accessories with metal enclosure made of 14 SWG (2mm) powder coated MS sheet with minimum length of each leg will be 600 mm or above from ground level and as per IS:1180 copper wound with proper cable end copper lugs connection as per CEE' latest specification as per site condition. Above/
Installation, commissioning, testing and connection of 5 KVA indoor type distribution transformer including concrete foundation. Above/
Supply of LT cubicle type outdoor wall / floor mounted Distribution Panel Board made of 14 SWG ( 2mm ) MS sheet duly powder coated comprising with the following : a) MCCB with Microprocessor Release of breaking capacity 36kA at 415V, AC 50Hz ( Ics = 100% Icu ) with following features :- 1) Adjustable Over Load, 2) Adjustable Short Circuit, 3) Inbuilt ground fault protection, 4) Inbuilt Instantaneous protection, 5) Adjustable neutral overload protection, 6) Provision of Thermal Memory, 7) Microprocessor protection-based MCCB must have facility of individual 'LSIG' fault indication suitable for Release Range ( 63-160 ) Amp, 4 Pole - 1 no. b) Power Contactor, 4 Pole, 24 100A, 415V, 50Hz - 2 nos. c) Astronomical Timer Switch, 2 module - 2 nos. d) Tinned Copper Busbar ( 4 Bar ) each of capacity 200 Amps., 415V, 50 Hz - 1 set e) Static Multifunction panel mounting LED Energy Meter suitable for operation on 3Ph, 415V, 50Hz supply, Cl 1 with provision of RS485 having display parameters - V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Runhours, On hours, Phase angle, Interrupts, THD, Events ( High-Low ), Neutral Current, K Factor - 1 no. f) CT of suitable ratio for MFM - 3 nos. g) LED indication lamp for Phases and "ON & OFF" indication for operating status of breakers - 12 nos. complete with all other accessories, internal wiring by single core FRLS grade copper conductor cable of suitable size and 1100V grade along with fabrication work, cable glanding, socketing etc. ( Make - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S ) ( Make for Meter & Energy Meter - ABB / Schneider / Secure / Legrand / LK (L&T) / Genus / Conzerv / Elmeasure / Stelmec / HPL / Socomec / Anchor / C&S ) Above/
Fixing, connection, testing and commissioning of above panel including all incoming and outgoing cables glanding, cable socketing and connection and construction of concrete foundation or suitable wall hanging arrangement as per site condition with all associated accessories Above/
Earthing with 2 nos.of 50 mm diametre, 3.0 metres long heavy gauge GI pipe ( Make - Tata / Jindal / Bansal ) including construction of earth pit and necessary earth connection from pit by suitable Galvanized Iron ( GI ) strip. ( For details not covered in this specifications, Indian Standard Code of Practice for earthing IS : 3043 - 1987, Reaffirmed - 1996 should be followed ) Above/ 2668140.0
Goods & Services Tax ( at present @ 18% )
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderBooklet.pdf
ATTACHMENT
Annexure-VA.pdf
ATTACHMENT
GCC_April-2022.pdf
ATTACHMENT
TenderFormandAnnexuresnew_1.pdf Tender form and annexure
ATTACHMENT
HTLTstandardspecification.pdf
ATTACHMENT
AnnexureVIB.pdf
ATTACHMENT
Advancecorrectionslips.pdf
ATTACHMENT
3622-RClause.pdf
ATTACHMENT
TenderFormandAnnexuresnew_1.pdf
ATTACHMENT
Download all tender documents and submit your bid