| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹80.1 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹80.6 L+₹49,145 (0.61%)Rejected-AOC ROMA BANJARA TANDA CHS BLDG NO 1 ROOM NO 507 607 MANKHURD W MUMBAI 400043 | MUMBAI | MUMBAI | MAHARASHTRA | 400043 | L2 | Rejected-AOC 2ND LOWEST BIDDER | |
| 3 | L3₹82.6 L+₹2.5 L (3.08%)Rejected-AOC ROMA BANJARA TANDA CHS BUILDING NO 1 ROOM NO 506 MANKHURD W MUMBAI 400 043 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400043 | L3 | Rejected-AOC 3RD LOWEST BIDDER | |
| 4 | L4₹84.7 L+₹4.5 L (5.63%)Rejected-AOC PLOT NO A 169 TTC MIDC KHAIRANE NEAR CNG PUMP NAVI MUMBAI DIST THANE 400 710 | NAVI MUMBAI | THANE | MAHARASHTRA | 400710 | L4 | Rejected-AOC 4TH LOWEST BIDDER | |
| 5 | L5₹1.2 Cr+₹36.7 L (45.8%)Rejected-AOC | L5 | Rejected-AOC 5TH LOWEST BIDDER |
Tender Value
₹93.2 L
EMD Value
₹1.9 L
Closing Date
4 Jul 2022, 3:00 pmClosed
CE Head HLUESS
HLUESS OFFICE RLG BARC
Painting to Radiological Labs and Filter House and carrying out flooring works with allied miscellaneous works at RLG Building BARC Trombay Mumbai 85
2022_BARC_693156_1
BARC/HUES/RC-234/03/2022-23
Open Tender
Civil Works
Item Rate
365 days
RLG FILTER HOUSE NHF
As per NIT
3 documents required · 3 mandatory
₹0
₹1.9 L
Yes
HLUESS OFFICE RLG BARC
11 Oct 2022
14 Jun 2022
6 Jul 2022
14 Jun 2022
4 Jul 2022
14 Jun 2022
14 Jun 2022 - 28 Jun 2022
29 Jun 2022
Amount
Replacing awnings roofing fabric Replacing of existing awning roofing fabric with new woven fabric made of 100% modacrylic soultions dyed fibers witha a flouorocarbon finish double side coated fire retardant 100% waterproof of approved make of at both wings of security guard house; sixe about 15 m x 3 m to plan area- each includng replacing entire existing ropes with new ones, applying extra fabirc layer with suitable alumnium patti & silicon materials at roofing jints for water tightness providing necessay scaffolding, ladders etc complete as per manufacturer's specifications and as directed by EIC
Repairing and repainting steel structures for awnings Dismantling of existing awning roofing fabric from both side size about 15 m x 3 m top areas each including providing necessary sacffolding ladders , removing of existing binding ropes, repairs of existing frames structures by carrying out minor welding works, provison of g. i. pipes if shrotages for repairings works, painting with epoxy PU paint using 2 coats of (120 micron dry film thickness) epoxy PU hihg build coating as finsing coat over a priming coat of EPILUX-13 High build primer of 50 micron thickness over steel surgaces at all frames structures, pillars etc preparation and applied as per manufacturer's specifications, disposing off fabrics and stacking it scrap points etc. complete as per specifications and as directed by EIC
REMOVING OLD PAINT & WHITE CEMENT PUTTY Providing and treating the OLD surface before appying paint paints i) entire old paint to be scrapped out ii) The neeru / cement punning to be removed by chipping completely iii) one coat of BIOWASH to be applied iv) entire surface to be finished with White cement based Wall putty of approved make to get uniform undulation free surface complete as directed by the Engineer-in-charge
WHITE CEMENT BASED WALL PUTTY Providing and applying white cement based wall putty of approved make over concrete or Plastered surface up to 3 mm thick to get uniform surface free from undulation including scaffolding, cleaning complete all as directed by the Engineer-in-charge
Two coat of Lustre Luxury emulsion paint Providing, applying wall painting two coats with Lustre paint of approved brand to give an even shade with out cement primer, including preparation of the surfaces, scaffolding complete. as per specifications and as directed by the Engineer-in-charge
Two coat of Lustre Luxury emulsion paint with primer Providing, applying wall painting two coats with Lustur paint of approved brand to give an even shade over a coat of cement primer including preparation of the surfaces, scaffolding complete. as per specifications and as directed by the Engineer-in-charge
Two coats of synthetic enamel paint with primer Providing and Painting two coats of synthetic enamel paint on steel surfaces of approved brand and manufacture to give an even shade over a primer coat.including preparation of the surfaces, scaffolding complete. as per specifications and as directed by the Engineer-in-charge
Two coats of synthetic enamel paint Providing and painting over wooden surfaces with synthetic enamel paint of approved brand and manufacturer of required colour to give an even shade with two coats on new work excluding wood primer including preparation of the surfaces, scaffolding complete. as per specifications and as directed by the Engineer-in- charge.
Epoxy paint ON CONCRETE/PLASTERED SURFACES Providing and Painting with Epoxy paint at all locations prepared and applied as per manufacturer' specifications including a priming coat if specified by the manufacturer , preparation of surface and etching with 10% commercial Hydrochloric acid wherever necessary and neutralizing the acid etched areas by washing with 5% solution of soda ash neatly and washing with sufficiant water, after first coat Epoxy based trowelling compound if required, including preparation of the surface by scrapping, applying sand paper, filling the holes, joints, cracks if any,scaffolding etc. complete.all as per manufacturers Technical Data and as directed at site to acheive 200 micron dry film thickness (50 micron primer coat and 150 micron finishing coat).
Epoxy paint ON STEEL SURFACES Providing and painting two (or) more coats with Epoxy paint at all locations prepared and applied as per manufacturer' specifications including a priming coat if specified by the manufacturer, preparation of surface by cleaning with wire brush and rubbing with sand paper to remove dust, dirt etc, after first coat Epoxy based trowelling compound if required, including preparation of the surface by scrapping, applying sand paper,by cleaning with wire brush and rubbing, making free of rust, dirt etc. filling the holes, joints, cracks if any, Scaffloding etc. complete.all as per manufacturers technical data and as directed at site to acheive 200 micron film thickness (50 micron primer coat + 150 micron finishing coat).
Polysulphide compound Providing and applying Polysulphide compound in “V” grooves of 10 mm size for sealing gaps for airtight-ness including applying a coat of primer,cutting and making the existing cracks in V shape of required depth, scaffolding etc to be completed generally as per specifications and directed by EIC.
6 mm thick Flat fibre cement sheets Supplying and fixing of 6 mm thick Flat fibre cement sheets in ceiling including fixing the sheets to existing frame work with Stainless steel(SS) nuts bolts of suitable size about 5mm(3/16) x 25 mm including forming necessary grooves as required; cutting the sheets to required sizes, making necessary openings around electrical fixtures, A.C. grills and trap doors; fixing to correct lines and levels; cleaning and removing glass wool and other existing materials if any found above false ceiling; removing of existing broken sheets as required cleaning of site, scaffolding; other incidental charges and disposed off unwanted materials & dumped at debris disposal point filter house at a distance of 300 m etc complete generally as per specification and as directed by E-I-C.
2.00 mm thick PVC sheet / tile Providing and Fixing Homogeneous 2.00 mm thick PVC sheet / tile in flooring and skirting of approved make in approved pattern on a smooth and damp proof base using rubber based adhesive of approved quality and manufacturer including, levelling small undulations with plasterof paris if required , rolling with light wooden roller weighing about 5 kg all complete as directed by Engineer-in-charge in approved colour and shade
Mandays Mandays required for carrying out miscellaneous civil works including removing/shifting of equipment, machines, tools etc. specially at Highbay areas, cleaning of drains etc. complete as directed by Engineer-In-charge.
Elastomeric water proof exterior grade paint Providing and painting walls with (TWO coats) of approved shade of high build protective , elastomeric water proof exterior grade paint of approved make of required shade, minimium dry film thickness of 250 microns acheived in two or more coats / as per manudacturer's specifications including preparation of the surfaces by scrapping / wire brush , scaffolding complete. Primer coat will be with approved make with water in ratio of 1:2 and 2 coats of finishing coat without water all as directed by Engineer-in- charge.
Colour painting to paver blocks Providing and painting, finishing with one coat of acrylic primer sealing coat and finishing with acrylic based colour paint followed by top sealing coat including surfaces with water jetting @ 25 bar minimum pressure etc complete as per manufacturer's specifications and as directed by the Engineer- in-charge.
SELF LEVELLING EPOXY FLOORING Providing and laying 2mm thick Self levelling Epoxy flooring as given below, including preparation of the surface, primer coat,screeding & levelling coat and finishing coat with Polyurethene coat of approved colour and shade of approved make all as per manufacturers specifications complete as directed at site by the Engineer-in-charge (This Job to be carried out through a specialized approved agency)
Strucrtural repairs with SBR Providing structural Repairs in Old Damaged concrete structures / surfaces with approved Polymer . With following operations 1) Removal of loose/Spaled or damaged concrete by chipping and cleaning the concrete suface and Reinforcement steel with wire brush and with water jet.2) Cleaning the Re bars with Acetone for complete Rust removal and washing with water jet to make the surface free from Acid content. 3) Applying Protective Coat / bond coat using Polymer and Cement in the proportion of 1; 1.5 ( 1 part of polymer and 1.5 parts of cement in Synthetic enamal paint like consistancy with brush 4) Reinstate the area with polymer modified mortar in layers of maximum 20 mm with the proportion of Cement 50 Kg : Washed and dried river sand 87.50 kg ; Silica sand 37.50 Kg. mixed with 10 litres of Polymer ( or 1 Kg cement : 1.75 kg Washed and dried river sand ; 0.75 Kg Silica Sand : 200 ml polymer)5) If thickness of repair exceeds 20 mm, after every 20 mm thick bond coat as per 2 above to be applied before continuing further structural repair works. This work is inclusive of all materials, labour, scaffolding complete all as directed at site . (Polymer "ROFFE/BASF/FOSROC" or approved equivalent make suitable for Structural repair shall be used ) Note:1)The contractor shall remove the debris generated during repairing from working site to BARC dumping point. 2) Providing suitable temporary scafolding or movable working platform at site.
Aluminium Composite Metal Panel Designing, providing and fixing of 4 mm thick approved make and shade Aluminium Composite Metal Panel of approved make cladding at different locations including soffits of over-hangs but excluding aluminium frame work with grids filled in with weather silicon sealant as per the drawings. The ACM panel composition shall be of 0.5 mm thick PVDF coated aluminium sheet + 3 mm thick low density polyethelene virgin resin core + 0.5 mm thick polyester (PVDF) coated Aluminium sheet all complete as per approved shop drawings and specification. Note: 1.Aluminium frame work will be paid under reelevant item. 2. ACMP shall be measured to the actual visible area of the ACP sheet including silicon joints as fixed on site.
ALUMINIUM WORK Providing and fixing anodized aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / Z sections and other sections of approved make conforming to IS 733 and IS 1285 fixed with rawl plugs and screws or with fixing clips or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC / neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically whereever required including cleat angle, aluminium snap beading for glazing / panelling, C.P brass / stainless screws all complete as per drawings and and directions of Engineer-in-charge including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required filling the gaps using silicon grout sealent etc. (fittings glazing and panelling shall be paid for separately)Anodised Aluminium sections (Minimum anodizing thickness of 15 micron) with colour anodizing.
Full height Chain link fencing paint from both side Repainting of chain link fencing (including angle supports, concertina, barbed wires, gates, etc) of about 3.15m overall height with two coats of SYNTHETIC ENAMEL paint of approved shade and make over one coat of approved steel primer on both sides including preparing the surfaces, removal of creepers, weeds, etc; scrapping of old loose/damaged paint as required, sand papering, scaffolding and cleaning etc, complete as required to suit site and as directed by Engineer-in-charge. Note:
Sealing by using of PU Foam Supplying, applying, cutting and levelling of PU foam for sealing of existing gaps, holes in false ceiling etc complete generally as per specifications of manufacturers and as directed by EIC. Note 1 Can = 750 ml volume.
M/S A.M CONSTRUCTIONS
SUNIL CONSTRUCTION
R C Bidave
ANS Constructions.com
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .