Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.6 LAccepted-AOC A 9 117 KALYANI PO KALYANI KALYANI NADIA WEST BENGAL 741235 | NADIA | WEST BENGAL | 741235 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹46.9 L+₹43,955.50 (0.95%)Rejected-Finance C O PULOKE NEOGI SURYA SEN PALLY PO KADAMTALA 734011 DIST DARJEELING WB | KADAMTALA | DARJEELING | WEST BENGAL | 734011 | L2 | Rejected-Finance Unsuccessful bidder | |
| 3 | L3₹47.1 L+₹62,320 (1.34%)Rejected-Finance GADADHAR PALLY PO PS BAGDOGRA DIST DARJEELING WEST BENGAL PIN 734014 | BAGDOGRA | DARJEELING | WEST BENGAL | 734014 | L3 | Rejected-Finance Unsuccessful bidder | |
| 4 | L4₹47.3 L+₹81,777 (1.76%)Rejected-Finance | L4 | Rejected-Finance Unsuccessful bidder | |
| 5 | L5₹47.8 L+₹1.3 L (2.86%)Rejected-Finance C O KALIPADA MITRA SOUTH BHARAT NAGAR NEAR JAGDISH CHANDRA HIGH SCHOOL SILIGURI DISTT DARJEELING WB 734004 | JALPAIGURI | WEST BENGAL | 734004 | L5 | Rejected-Finance Unsuccessful bidder |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
14 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Bagdogra
GE AF Bagdogra Bagdogra Airport PO, Dist Darjeeling, WB - 734421
ADDN/ ALTN TO LT NETWORK AND ALLIED WORKS AT 273 SU AF UNDER GE (AF) BAGDOGRA
2024_MES_643435_1
8540/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF Bagdogra
As per NIT
8 documents required · 8 mandatory
₹500
GE AF Bagdogra
₹87,000
Yes
20 Mar 2024
22 Feb 2024
15 Mar 2024
22 Feb 2024
14 Mar 2024
7 Mar 2024
Amount
Supply, installation, testing and commissioning of Isolation Transformer, 25 KVA, 3 Phase, 50 Hz, indoor type, Copper Wound, Oil cooled, Class of insulation A, metallic body powder coated designed for Input Voltage range 415V, + - 5% and Output Voltage range 415V, + - 5%, with ratio of 1:1, Vector Group : Dyn 11, Delta - Star with first filling of transformer oil of requisite dielectric strength upto level, efficiency more than 95%, separate neutral bushing shall be brought out for earthing. Potential difference between neutral to earth less than one volt with all standard fittings like, digital temperature meter, adequate number of cooling radiators, lifting hooks one set, Earthing terminals 02 Nos complete with over load/ short circuit protection and testing as per BIS 9815 all as specified and directed.
Supply, installation, testing and commissioning of Isolation Transformer, 50 KVA, 3 Phase, 50 Hz, indoor type, Copper Wound, Oil cooled, Class of insulation A, metallic body powder coated designed for Input Voltage range 415V, + - 5% and Output Voltage range 415V, + - 5%, with ratio of 1:1, Vector Group : Dyn 11, Delta - Star with first filling of transformer oil of requisite dielectric strength upto level, efficiency more than 95%, separate neutral bushing shall be brought out for earthing. Potential difference between neutral to earth less than one volt with all standard fittings like, digital temperature meter, adequate number of cooling radiators, lifting hooks one set, Earthing terminals 02 Nos complete with over load/ short circuit protection and testing as per BIS 9815 all as specified and directed.
Supply, installation, testing and commissioning of Isolation Transformer, 5 KVA, 1 Phase, 50 Hz, indoor type, Copper Wound, Oil cooled, Class of insulation A, metallic body powder coated designed for Input Voltage range 240 V, + - 5% and Output Voltage range 240 V, + - 5%, with ratio of 1:1, first filling of transformer oil of requisite dielectric strength upto level, efficiency more than 95%, separate neutral bushing shall be brought out for earthing. Potential difference between neutral to earth less than one volt with all standard fittings like, digital temperature meter, adequate number of cooling radiators, lifting hooks one set, Earthing terminals 02 Nos complete with over load/ short circuit protection and testing as per BIS 9815 all as specified and directed.
M&L for submain wiring with four runs of single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLS type, cables 4 Sqmm for 3 phases and neutral drawn through and including rigid PVC heavy duty conduits/ casing caping including two runs of 4 Sqmm 1100Volts grade, FRLS type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals as per site requirement complete all as specified and directed.
M&L for submain wiring with four runs of single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLS type, cables 2.5 Sqmm for 3 phases and neutral drawn through and including rigid PVC heavy duty conduits/ casing caping including two runs of 2.5 Sqmm 1100Volts grade, FRLS type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals as per site requirement complete all as specified and directed. Note (For Srl No. 4 & 5) :- (i) Four runs of cables for three phases and neutral and two runs of continuous earthing cable drawn through and including in PVC conduit/ casing caping will be measured as one unit length of sub main. (ii) PVC conduit and its accessories is deemed to be included in this item. (iii) Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall, floors etc.
Supply, laying, testing & commissioning cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 Sqmm, 3.5 core complete all as specified and directed.
Supply, laying, testing & commissioning cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, testing & commissioning cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, testing & commissioning cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, testing & commissioning cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, testing & commissioning cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, testing & commissioning cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 core complete all as specified and directed.
Supply, laying, testing & commissioning cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 core complete all as specified and directed.
Supply, laying, testing & commissioning cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 4 core complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for taking out pipe line etc for repair/ laying cables etc and getting out in soft / loose soil complete all as specified and as directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed.
Removal of excavated material [soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
M&L for clean dry sand in trenches/ducts for cushioning to cable complete all as specified & directed. Note: Punned thickness shall be measured.
Supplying and laying Bricks; common burnt clay building bricks, sub-class ‘B’ designation 75 complete all as specified and as directed.
M&L for Earthing complete with copper earth plate electrode 60cm x 60cm x 3.15mm thickness burried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to and incl galvanised iron strip 32x6mm by means of nuts & bolts, check nuts and washers of brass incl PCC pit of 1:2:4, type B-1, cover reinforced with XPM weight not less than 4 Kg/Sqm and 6mm dia bar handle, earth pit angle iron frame of size 25x25x3mm, excavation and earth work in any type of soil, charcoal dust, salt, light grade GI watering pipe 20mm bore with funnel and wire -mesh and medium grade GI protection pipe of 40mm bore from top edge of earth plate upto main distribution board complete all to as shown in electrical plate No 3 of MES SSR Part I 2009 connected board all as specified and testing on completion. Note:- The earth resistance should be less than one ohms and GI protection pipe and earth lead more than 7.5 RM shall be measure and paid separately.
Supply, install, testing & commissioning floor mounting cubicle type indoor compartmentalized 415 volts , 50 Hz dust & moisture proof feeder panel board fabricated by CPRI approved panel manufacture, sheet should be 14 (2.0MM) SWC CRCA sheet. The panel should have adequate strength and space to accommodate the incoming & outgoing XLPE cable suitable capacity Aluminium bus bars. The panel board should be painted by powder coated paint. The panel board should comprise with the following :- ACB 800 amps 415 volts breaking capacity 50kA, 4 pole draw out with microprocessor based LSIG Release ACB, MDO type, Icu@415V= ICS=ICW= 100% and ICW for 1 sec = 50kA conforming to IEC 60947-2 standards, Digital Ammeter 0-800 A, Digital Voltmeter 0 -500V R-Y-B LED indicator lamps 03 Nos 800/5 Amps CT 03 Nos complete all as specified and directed.
S&F 3 Pole MCCB 125 Amp, 50Hz, Breaking capacity at 415V with rupturing capacity Icu 36 kA and Ics(Icu) 100% complete all as specified and directed.
S&F 3 Pole MCCB 63 Amp, 50Hz, Breaking capacity at 415V with rupturing capacity Icu 25 kA and Ics (Icu) 100% complete all as specified and directed.
S&F 4 Pole MCCB 200 Amp, 50Hz, Breaking capacity at 415V with rupturing capacity Icu 36 kA and Ics (Icu) 100% complete all as specified and directed.
S&F 4 Pole MCCB 250 Amp, 50Hz, Breaking capacity at 415V with rupturing capacity Icu 36 kA and Ics (Icu) 100% complete all as specified and directed.
S&F 4 Pole MCCB 400 Amp, 50Hz, Breaking capacity at 415V with rupturing capacity Icu 36 kA and Ics (Icu) 100% complete all as specified and directed.
NOTES :- 1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum.
SHRI P P SHARMA
UNISON CONSTRUCTION
M/s Chakraborty Enterprise
M/S MANAS MITRA
M/S MOHAN GHOSH
SUNIL DAS AND CO
M/S ALPHA BETA CONSTRUCTION
RAMKRISHNA NARAYAN ROY & CO
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .