Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.7 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹40.6 L+₹2.9 L (7.70%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L-1 | |
| 3 | L3₹40.6 L+₹2.9 L (7.75%)Rejected-Finance 94 PHASE II HOUSEING COLONY UDHAMPUR J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-Finance OTHER THAN L-1 | |
| 4 | L4₹40.7 L+₹3.0 L (8.06%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L-1 | |
| 5 | L5₹41.2 L+₹3.5 L (9.26%)Rejected-Finance KERNI MARKET COURT ROAD UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | L5 | Rejected-Finance OTHER THAN L-1 |
Tender Value
₹38.9 L
EMD Value
₹78,000
Closing Date
22 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh A K Dubey IDSE SE CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
SPL REPAIR TO BLDG NO T-233 (MT PERS LINE), P-04 (BLOOD BANK) AND P-30 (BASERA) AT COMD HOSP NORTHERN COMD UNDER GE (NORTH) UDHAMPUR
2022_MES_507374_1
CA NO CWE/U(N)-102/2021-22
Open Tender
Civil Works
Item Rate
270 days
UDHAMPUR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE (NORTH) UDHAMPUR
₹78,000
Yes
31 Mar 2022
11 Feb 2022
24 Mar 2022
11 Feb 2022
22 Mar 2022
10 Mar 2022
60 days
Amount
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings including ridges, complete all as specified and as directed by Engr-in-Charge.
Dismantling wall and ceiling boards (fibre pulp, insulation etc) or insulation boards / slabs / blankets, any thickness, including cover fillets and frame of any type, complete all as specified and as directed by Engr-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed by Engr-in-Charge.
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level), complete all as specified and as directed by Engr-in-Charge.
75mm thick Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in sub base to floor, complete all as specified and as directed by Engr-in-Charge.
50 mm thick, Plain cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregates) as in sub base/base course to floor finished fair and even , complete all as specified and as directed by Engr-in-Charge.
Factory made, Machine pressed / vibro mechanically floated coloured interlocking cement paver block ISI marked, any shape and size conforming to IS 15658-2006 of 60mm thickness, M-35 Grade, with topping of cement with imported pigment complete all as specified and as directed by Engr-in-Charge.. Shape shall be approved by Engr-in-Charge.
Sand cushioning under floors including watering and consolidation complete all as specified and as directed by Engr-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.), complete all as specified and directed by Engineer-in Charge.
Description all as per item No 09 above but area exceeding 1.50 square metre and not exceeding 4 square metre each.
Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.4 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed by Engineer-in Charge.
Mild steel butt hinges medium weight cold rolled, 100mm size, complete all as specified and directed by Engineer-in Charge.
250 mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed by Engineer-in Charge. (ISI Mark)
150 mm aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed by Engineer-in Charge. (ISI Mark)
150 mm aluminium handles, cast type anodised complete all as specified and directed by Engineer-in Charge. (ISI Mark)
Pressed steel frames for doors, made out of 1.25 mm thick MS sheet, with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete, of frame size 105 mm x 60 mm, including one shop coat of red oxide zinc chrome primer, complete all as specified and as directed by Engr-in-Charge.
Cutting chases, pinning in making good to facings in brick walls where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth, complete all as specified and as directed by Engr-in-Charge.
35mm thick, factory made 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete, all as specified and directed by Engr in Charge.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm wallnut colour PVC sheet reinforced with M.S. Square tube in opening as per specification & drawing, complete all as specified and as directed by Engr-in-Charge.
Factory Made Solid PVC Moulded Door Shutter of wallnut color, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, with particle board core, supplying & fixing in frame at site as per specification & drawing as per specification & drawing, complete all as specified and as directed by Engr-in-Charge.
Taking down eaves gutters and rainwater pipes/soil pipes (any size, type or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., for (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and as directed by Engr-in-Charge.
110mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls, complete all as specified and as directed by Engr-in- Charge.
75mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls, complete all as specified and as directed by Engr-in- Charge.
75 mm bore PVC SWR bends/ shoes with oval access door any radius , complete all as specified and as directed by Engr-in- Charge. (ISI Marked)
75mm PVC multi floor traps with grating including jointing to waste pipe fixed cncrete type B1 (1:2:4). complete all as specified and as directed by Engr-in- Charge. (ISI Marked)
110 mm bore PVC SWR bends/ shoes any radius , complete all as specified and as directed by Engr-in- Charge. (ISI Marked)
110 mm bore PVC SWR bends any radius with acess door and fixed solvent etc complete all as specified and as directed by Engr-in- Charge. (ISI Marked)
PVC SWR junction , single (single/double T with oval access door) equal or unequal 110 mm size fixed with joint sealent etc complete all as specified and as directed by Engr-in- Charge.
75mm PVC (SWR) vent cowls complete all as specified and as directed by Engr-in- Charge.
Taking down 25 mm Bore steel tubing and connections including all fittings and removing from store,complete all as specified and as directed by Engr-in- Charge.
Taking down 15 mm Bore steel tubing and connections including all fittings and removing from store, complete all as specified and as directed by Engr-in- Charge.
25mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed complete to walls and or laid under floors etc complete all as specified and as directed by Engr-in- Charge.
15mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed complete to walls and or laid under floors etc complete all as specified and as directed by Engr-in- Charge.
Gun metal globe of gate valve with iron wheel head, screwed both ends of size 25mm fixing in repair, complete all as specified and as directed by Engr-in- Charge.
Vitreous china water closet, 'Orissa pattern, including lime concrete bedding, size 580 x 440 mm white with integral foot rests excluding flushing cistern and flush pipe but including connection to trap, anti syphonage pipe etc. complete fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Vitreous China wash down water closet pan and seat cover (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including P or S trap and including plastic water closet seat, black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device, including connection to drain pipe (or out going pipe) and to flushing pipe, antisyphonage pipe, etc. including cast iron 'P' or 'S' trap for 100mm bore of pipe, fixed in repairs complete all as specified and as directed by Engr-in-Charge.
10 ltr capacity PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets with twin flush provision, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
PVC connection 15mm size with PTMT nuts of length 600mm fixed in repair complete all as specified and as directed by Engr-in-Charge.
Grating doom 100mm dia of Stainless steel fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Angle stop valve of CP Brass fancy type with capstan head, complete all as specified and as directed by Engr-in-Charge.
Brass Chromium plated over head shower rose of size 100mmx100mm with swivel joint and arm 200mm long with wall flange fixed to pipe or union of 15mm bore, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
S&F health faucet ABS body with wall hook and 1.0 metre long chrome plated PVC hose pipe complete all as specified and as directed by Engr-in-Charge.
Bib taps , fancy type cast copper alloy, chromium plated, with crutch or butterfly handle screwed down for iron pipe or for brass ferrule for bore of pipe 15 mm fixing in repair, complete all as specified and as directed by Engr-in-Charge
600 mm x 450 mm bevelled edge mirror of thickness 5/5.5mm of slected quality glass, mounted on 6 mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete, all as specified and as directed by Engr-in-Charge.
Rotational moulded polyethylene water storage tank , two layers, ISI marked (cylinderical vertical with closed top) hoisted with Threaded Cap and fixed in position all as specified in SSR Part-I of Capacity 2000 litres each including all accessories (i.e GI nipples and Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of bore 20mm/25mm (Minimum weight 210 gram) etc), complete all as specified and as directed by Engr-in-Charge.
Stack clamps out of 25mm by 3mm flat iron clamps fixed with stays,including bolts and nuts and securing ends of stays to wall or roof for 110mm bore of pipe fixed in repairs complete all as specified and as directed by Engr-in-Charge.
PVC (SWR) floor trap plain of size 75mm , with grating including jointing with solvent cement, complete all as specified and as directed by Engr-in-Charge.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, removing all type of vegetation (like peeple tree etc) scrubbing down with water complete, all as specified and as directed by Engr-in-Charge.
15 mm thick rendering in two layer (10mm + 5mm) on fair faces of brick /concrete on wall including facia chhajja incl necessary dubbing out wherever necessary etc. surfaces in cement mortar 1:4 and finished even and smooth without using extra cement including mixing Liquid water proofing compund in the proportion as mentioned in manufacturer's instructions complete all as specified and as directed by Engr-in-Charge. Note : Water proofing compund to be measured and paid for separately as supply only.
10mm thick rendering on other than fair faces of brick or concrete surfaces in cement mortar 1:6, finished even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
5mm thick rendering on brick or concrete surfaces as in ceiling in cement mortar 1:4, and finish the surface even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Non skid, coloured ceramic jointfree/rectified tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed by Engr-in-Charge.
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, complete all as specified and as directed by Engr-in-Charge.
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius in half brick thick built in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
Use and waste of form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. to obtain rough flat finished surface of concrete complete all as specified and as directed.
RCC 1:2:4 type B-1, using 20 mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and as directed by Engr-in-Charge. Note : Design/Sectional detail of RCC structure shall be decided by Engr-in-Charge as per ground requirement.
Applying two coats of oil bound distemper over and including a coat of primer and 1 mm thick a layer of wall care putty (JK Birla) including preparation of old plastered/ unplastered surfaces of wall, including complete removal of existing treatment complete all as specified & directed by Engr-in-Charge.
Applying two coats of oil bound distemper over and including a coat of primer and 1 mm thick a layer of wall care putty including preparation of new plastered/ unplastered surfaces of wall, complete all as specified & directed by Engr-in-Charge.
Preparing of old decorated surfaces of wall, chajjas, etc. by brooming down or steel wire brushing, scrapping down smoke soots, moulds, efflorescence salt, treading oil, greasy spots or washing rubbing down and applying two coat of white wash on walls surfaces, complete all as specified and as directed by Engr-in-Charge.
Preparing of old decorated surfaces of wall, chajjas, etc. by brooming down or steel wire brushing, scrapping down smoke soots, moulds, efflorescence salt, treating oil, greasy spots or washing rubbing down and applying two coat of white wash on ceiling surfaces, complete all as specified and as directed by Engr-in-Charge.
Preparing newly plastered or unplastered surfaces of wall and applying two coats of cement base paint over and including a coat of primer, complete all as specified and as directed by Engr-in-Charge.
Preparing old plastered or unplastered surfaces of walls and applying two coat of cement base paint , complete all as specified and as directed by Engr-in-Charge.
Machine cut kota stone slab flooring 18-20 mm thick over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including Screed bed or bedding layer of mortar 20mm thick in cement mortar 1:3, complete all as specified and as directed by Engr-in-Charge.
Machine cut kota stone slab flooring 18-20 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 10 mm thick CM 1:3 mortar backing for fixing the stone slab, complete all as specified and as directed by Engr-in-Charge.
80/100 mm wide x 550 mm long & 12 mm thick marble border of approved colour(white/green/yellow etc.), machine cut, bedded jointed and pointed with grey cement slurry, as in floors laid over cement screed base and jointed with white cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including avg 20 to 25 mm thick screed bedding/ backing layer in CM 1:3, complete all as specified and as directed by Engineer-in-Charge.
18-20 mm thick green marble (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including cutting and polishing over and including 15 mm thick screed bedding/ backing layer in CM 1:3, complete all as specified and as directed by Engineer-in-Charge.
Demolition of Cement Concrete (reinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and as directed by Engr-in-Charge.
Reinforced cement concrete 1:2:4 type B1, (using 20 mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and as directed by Engr-in-Charge. Note : Design/Sectional detail of RCC structure shall be decided by Engr-in-Charge as per ground requirement.
Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc to obtain rough flat finished surface of concrete complete all as specified and as directed.
TMT mild steel bars, 6-8mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and including binding with MS wire (annealed not less than 0.9mm dia), complete all as specified and as directed by Engr-in-Charge.
Pre-painted coloured corrugated profiled Galvalume/Zincalume sheet with min 0.50mm TCT with BTM of 0.45mm thick conforming to IS -513(AZ-150 GSM,Al Zn alloy metallic coating 550MPA yield stress as per AS-1397),as in roof covering/clading to wall fixed with self taping screws, colour/exterior coat of silicon modified polyster/ BHP x RW paint system 20 micron top coat applied over 5 micron primer and a micron polyster back coat applied over 5 micron primer,all fixed with galvanised self drilling self tapping fastener(12-14x55 with EPDM seals) incl gap filling with PCC(1:3:6) type C-0 in between wall and sheet, complete all as specified and as directed by Engr-in-Charge.
Pre-painted coloured plain steel profiled Galvalume/Zincalume sheet with Min 0.50 mm TCT with BTM of 0.45mm thick conforming to IS-513(AZ-150 GSM, Al Zn alloy metallic coating 550 MPA yield stress as per AS-1397) as roof ridge colour/exterior coat of silicon modified polyster/BHPxRW paint system 20 micron top coat applied over 5 micron primer and a 5 micron polyster back coat applied over 5 micron primer ,all fixed with Galvanised self drilling self-tapping fastener (12-14x55 with EPDM seals) complete all as specified and as directed by Engr-in-Charge.
Rolled mild steel in roof trusses (framed) , trussed , purlins,crane gantries , rails and fastening and heavy bracket framing ( beam, tee, angle, channel or flat section) including gusset plate, MS Bolts & nuts, distance peices etc. conforming to Fe 410-W, Gde E-250 Quality 'A', complete all as specified and as directed. Note: All steel structures (truss and other member) shall be as per Drg No CE/TD/911/88 Sheet 1/20 t0 20/20.
S&F false ceiling with fibre cement designer tile any colour painted (high pressure steam cured) of 4 mm thickness (as per IS:14862) of size 595 x 595 mm and any one of the design (occeanic, lake & hill,cascade or electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 gms, both side inclusive) consisting of main 'T' runner with suitably spaced joints to get required length, and 15x32 mm made of 0.30 mm sheet, and cross'T' at 600mm c/c to form a grid including, required cutting/making, opening for services like diffusers,grills, light fittings, fixures, smoke detectors etc. Main 'T' runners to be suspended from ceiling using Gl soffit cleats fixed to existing rafter, purlin, etc with galvanised Butterfly level clips, spaced at 1200 mm c/c along main T, bottom exposed width of 15 mm of all T- sections shall be centra black pre- painted with polyester paint, and having a load bearing capacity of 12 kg/sqm, and refixed all existing electric wiring and fixture all complete at all heights as per direction of Engineer-in -Charge.
Factory made (box type) mild steel combined windows/ventilators glazed and gauzed shutters with side hung including pintol hinges, steel peg stay , locking arrangement with glazing & gazing bars dovetailed or welded and one shop coat of red oxide primer complete all specified. Note : i) The windows/vents shall be fabricated as per Drg No CEUZ/TD/1302/2009 Sheet 1/3 to 3/3. ii) Glazing, wire gauge shall be measured and paid for separately. (iii) One side out to out size shall be measured for payment purpose.
Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar, barred iron doors; ladder, framed balusters; railing; frame work for water tanks, cooler stand etc and similar work conforming to FE 290-0 or Gde-E-165, complete all as specified and as directed by Engr-in-Charge.
Preparation of new steel surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over a coat of zink chrome primer, complete all as specified and as directed by Engr-in-Charge.
Supply and fixing flush pipe of polyethylene of low or high density or PVC. 32 mm dia suitable for EWC/orrisa WC etc, for low level cistern, complete all as specified and as directed by Engr-in-Charge.
Stop valves/Angle valve, fancy type chromium plated cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 15mm, complete all as specified and as directed by Engr-in-Charge.
Pillar taps, swan neck fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe of bore 15 mm, fixed in repair, complete all as specified and as direceted by Engr-in-Charge.
18-20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including cutting and polishing over and including 15 mm thick screed bedding/ backing layer in CM 1:4, complete all as specified and as directed by Engineer-in-Charge.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as direceted by Engr-in-Charge.
Stop valves, fancy type, chromium plated, cast copper alloy, with long shank and cup (concealed type) screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 15mm, complete all as specified and as direceted by Engr-in-Charge.
Oval Counter top vitreous China wash basin, snow white, of size 550x400mm excluding taps,but including CP waste coupling, CP bottle trap complete all as specified and directed by Engr-in-Charge.
Tubular towel rails brass chromium plated, 20 mm dia, D type, 60 cm long between flanges, fixed with rawl plugs fixed in repairs, complete all as specified and directed by Engr-in-Charge.
Mild steel bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165.
Cutting holes into or through brick walls exceeding half brich but not exceeding one brick, built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed by Engr-in-Charge.
Preparation of new wooden or wood based surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over and including a coat of pink primer, complete all as specified and as directed by Engr-in-Charge.
S&F in repairs Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc. complete all as specified and as directed by Engr-in-Charge.
Vitrified tiles (double charged) of 10mm thick any approved light colour (area of each tile exceeding 0.42 sqm but not exceeding 0.72 sqm) as in floors jointed in cement slurry and pointed in white or coloured cement to match the existing surfaces over and including 15 mm thick screed bedding/ backing layer in CM 1:4, complete all as specified and as directed by Engr-in-Charge.
Glazed coloured ceramic jointfree/rectified tiles 600mm x 300mm x 8 to 9mm on vertical surfaces of walls as in dado/skirting etc., set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including 10 mm thick screed bedding/ backing layer in CM 1:3, complete all as specified and as directed by Engr-in-Charge.
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z or sliding sections etc. and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators of openable/sliding type including rollers & locking arrangement, including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-Charge.
5mm Sheet glass, tinted/ frosted as approved quality and glazing with rubber neoprene packing for aluminium doors/windows in square/rectangular exc 0.5 sq. m in each pane, complete all as specified and as directed by Engr-in-Charge.
Forming jambs, etc. to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete complete all as specified and as directed by Engr-in-Charge.
4mm thick ACP sheet of approved color fixed into door panels/fixed glazing etc. with aluminium beading and EPDM rubber complete all as specified and as directed by Engr-in-Charge.
S&F Aluminium (Die cast) body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 68 kg complete all as specified and as directed by Engr-in-Charge. (ISI Mark)
Supply and fixing 18/19mm thick plywood grade 'A' (termite treated/water proof), type BB fixed with screws to timber/iron frame work as in cup boards/cabinet shutter etc., complete all as specified and as directed by Engr-in-Charge.
0.90 mm thick decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions, complete all as specified and as directed by Engr-in-Charge.
Second class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed all as specified and directed.
Plinth protection 50 mm thick in PCC 1:2:4, type B-2 ( using 40 mm graded crushed stone aggregate) laid in alternate bays (not exceeding 2 Sqm each) finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitument 85/25 grade and three parts of sand by weight, complete all as specified and as directed by Engr-in-Charge.
35 mm thick decorative face flush moulded shutters (as per sample) ,solid core construction,with block board core and decorative face pannels on both sides with lipping/frame to match complete all as specified and as directed by Engr-in-Charge.
300 mm long mild steel ordinary rat tail rod pattern door spring including roller and roller plate, fixed to frame, complete all as specified and as directed by Engr-in-Charge.
Roughening surfaces of old concrete surfaces by picking up, sweeping, cleaning and washing down with water to remove dust etc and brushing neat cement slurry @ 3 kg/Sqm including 10mm thick screeding in CM (1:3) finished even and smooth mixed with water proofing compound (WPC shall be measured and paid separately). Applying bituminous primer on roof surfaces @ 0.40 ltr/Sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 Kg/Sqm and providing atactic polypropylene polymer (APP) modified five layered prefabricated water proofing membrane with thermal fusible properties on both side having 3.00mm thick (Min) and 4.00 kg. weight per SQM (Min) reinforced with non-woven spun bonded polyester reinforcement ‹ -2 C cold flexibility. The layer of the membrane shall be laid using butane torch and sealing all joints properly, leaving no bare edges or end of APP membrane and finishing the surfaces with trowel or otherwise to obtain a uniform surfaces. The minimum side lap and end lap shall be kept at 75mm and 100mm respectively and over APP applying one coat of hot blown bitument 85/25 @ 1.2 Kg/Sqm blinded with fine sand in dry condition @ 0.5 Kg/Sqm, complete all as specified and as directed by Engr-in- Charge.
Note for Item No 105 :- Water proofing treatment will be done by manufacturer of APP membrane or through their authorised specialized agency/applicator which will further have to rectification of any defect if incurred at a later stage, otherwise no payment shall be made to the contractor if water proofing treatment is executed otherwise.
Supply only Integral water proofing compound, complete all as specified and as directed by Engr-in-Charge.
Dismantling loose/disintegrated portion of RCC chajjas, bends, shelves, beams, balconies and similar work at any position or any height and dubbing out with PCC 1:1.5:3, 15mm to 50mm thick using 6 to 12mm graded stone aggregate to make up and finished required shape including applying anti corrosive paint on exposed surfaced and provision of necessary support form work and including 10mm thick plastering in CM 1:4 finished fair and even complete all as specified and as directed by Engr-in-Charge.
Factory made heavy duty full body Digital matt finish, paving Coloured tiles 300mm x 300mm x 10mm thick on vertical surfaces of walls as in dado/skirting etc., set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including 15 mm thick screed bedding/ backing layer in CM 1:4, complete all as specified and as directed by Engr-in-Charge.
Taking down carefully copper /aluminium, point wiring (light, fan, socket or power) complete including fittings and fixtures such as light fittings, switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of wall, ceiling, floors etc, complete all as specified and as directed by Engr-in-Charge. Note: Old dimanteled wiring and accessories (other than reuse) will be contractors properly and credit will be charged against scheduled of credit.
Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, LED bulk head fittings, LED tube light fittings and regulators, etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse) complete all as specified and as directed by Engr-in-Charge.
Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLSH) cable with multi stranded copper conductor wiring in and including PVC concealed conduit medium grade (ISI marked) 20mm dia and over, wall thickness not less than 2.00 mm thick , and all accessories for one light / bell controlled by one switch with 1.25mm thick pressed steel terminal anodized box concealed on walls, 3mm laminated plastic sheet cover for mounting of switches, socket outlet, regulator etc or suitable for modular type switches, socket outlet, regulator etc , fixed by suitable size of 4 Nos cadmium screws along with PVC insulated and unsheathed FRLSH 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, complete all as specified and as directed by Engr-in-Charge. Note: Necessary wall cutting/ chasing for conduit/ fixture will be done through electrical cutter machine only.
All as per description of Serial item No 112 here-in-before but for one bell/buzzer controlled by one push button on the independent board complete all as specified and as directed by Engr-in-Charge.
All as per description of Serial item No 112 above but one 3/5 pin 5 Amp socket outlet on the same board with other switch.
All as per description of Serial item No 112 here-in-before but one 3/5 pin 5 Amp socket outlet on independent board , complete all as specified and as directed by Engr-in-Charge.
All as per description of Serial item No 112 here-in-before but one 3/5 pin 15 Amp socket outlet on independent board with PVC insulated, unsheathed FRLSH cable 4Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLSH 4 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete all as specified and as directed by Engr-in-Charge.
Modular switch single pole one way 6/10 Amps 1 module type fixed in repair complete all as specified and directed by Engr- in-charge
Modular switch single pole one way 16 Amps 1 module type fixed in repair complete all as specified and directed by Engr- in-charge
Modular socket outlet, 2 in 1, 3 pin, 6 Amp flush type 2 module type, fixed in repair complete all as specified and as directed by Engr-in-Charge.
Modular socket outlet, 2 in 1, 3 pin, 16 Amp flush type 2 module type, fixed in repair complete all as specified and as directed by Engr-in-Charge.
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block, fixed in repair complete all as specified and as directed by Engr-in-Charge.
Bell (ding dong type), AC electronic type, 230 volts, single pole ,fixing in repairs, complete all as specified and as directed by Engr-in-Charge.
Modular bell push single pole one way 6 Amps 1 module type fixed in repair complete all as specified and directed by Engr- in-charge
Modular type stepped type fan regulator 120W, 230V 50 C/S, Deluxe 2 Modular electronic, hum free suitable control speed of fan from 0 to 100 % and connecting electrically fixed in repair complete all as specified and as directed by Engr-in-Charge.
Taking down fan, ceiling cable end, dismantling blades and removing fan and blades to store, and applying two coats painting with synthetic enamel to ceiling fans complete, in situ by spraying including filling cavities with filler, one coat after cleaning all dust etc., making all connection using 1.5 sqmm copper conductor multi strand PVC insulated 3 core flexible cable from ceiling rose to fitting including rapair ceiling fan 1200mm sweep, oiling, greasing cleaning slot, over hauling & replacement of defective nut bolts washer etc, and rehanging complete all as specified and as directed by Engr-in-Charge.
Fixing only light fittings any type as obtained against item No. 111, complete all as specified and as directed by Engr-in-Charge.
Decorative ultra slim linear surface mounted LED lighting fixture (4 feet length), 20Watt LED with integral electronic driver complete making connection and testing after fixing, fixed in repair complete all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Extruded (b) Operating Voltage : Between 150 V- 270V (c) Operating Temperature : -10 to +45 Degree Centigrade (d) Lumen efficacy : Not less than 110 lm/W (e) System Lumens : Not less than 2000 lm (f) Colour Temperature : Not less than 5700K (g) Surge Voltage Protection : Up to 2KV (h) Ingress protection : IP 20 (j) Total Harmonic Distortion (THD) : Not less than 20% (k) Power factor : Not less than : 0.90 (l) Line protection : Under/Over voltage Protection (m) Input Frequancy : 50 Hz
Decorative ultra slim linear surface mounted LED lighting fixture (2 feet length), 10 Watt LED with integral electronic driver complete making connection and testing after fixing, fixed in repair complete all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Extruded (b) Operating Voltage : Between 150 V- 270V (c) Operating Temperature : -10 to +45 Degree Centigrade (d) Lumen efficacy : Not less than 100 lm/W (e) System Lumens : Not less than 1000 lm (f) Colour Temperature : Not less than 5700K (g) Surge Voltage Protection : Up to 2KV (h) Ingress protection : IP 20 (j) Total Harmonic Distortion (THD) : Not less than 20% (k) Power factor : Not less than : 0.9 (l) Line protection : Under/Over voltage Protection (m) Input Frequancy : 50 Hz
LED CLEAN ROOM bottom opening SS frame IP65, dust free & zero maintenance, luminaire for hygeinic facilities, 2X2 LED, colour temperature-5700K, CRI>0.8, PF>0.95, THD< 10, 36 Watts, long life and photobiologically safe LED's, high performance electronic driver ensuring zero maintenance Instant light with low running temperatures, making all connection using 1.5 Sqmm copper conductor multistranded PVC insulated 2 core flexible cable, necessary arrangement fixing to GI wire at roof and hanging light with GI wire suitable size from roof to fitting with nuts, bolts etc. complete all as specified and as directed by Engr-in-Charge.
LED CLEAN ROOM bottom opening SS frame IP65, dust free & zero maintenance, luminaire for hygeinic facilities, 2X2 LED, colour temperature-5700K, System Lumens-5280lm, CRI>0.8, PF>0.95, THD< 10, input voltage 140-270 V, 60 Watts, long life and photobiologically safe LED's, high performance electronic driver ensuring zero maintenance Instant light with low running temperatures, making all connection using 1.5 Sqmm copper conductor multistranded PVC insulated 2 core flexible cable, necessary arrangement fixing to GI wire at roof and hanging light with GI wire suitable size from roof to fitting with nuts, bolts etc. complete all as specified and as directed by Engr-in-Charge.
New generation energy saving and environmental friendly long life LED street light of 35 watt with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment and impact resistance of IK07 with High efficiency long life LED with SMD LED on MCPCB Powered by Built-in, isolated electronic LED driver (SMPS based constant current supply) complete making connection and testing after fixing,and necessary arrangement GI tubing light grade suitable size dia length 1.2 mtrs incl clamps, bolts, nuts and washers etc., fixed in repair complete complete all as specified and directed by Engr-in-charge. The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Die Cast (b) Diffuser : High efficient LENS Optics (c) Operating Voltage : Between 150 V- 270V (d) Operating Temperature : -10 to +45 Degree Centigrade (e) Lumen efficacy : Not less than 100 lm/W (f) System Lumens : Not less than 2500 lm (g) Colour Temperature : Not less than 5700K (h) Surge Voltage Protection : Up to 4KV (j) Ingress protection : IP 65 (k) Total Harmonic Distortion (THD) : Not less than 20% (l) Power factor : Not less than : 0.9 (m) Line protection : Under/Over voltage Protection (n) Input Frequancy : 50 Hz
Sub main wiring with two runs of 6 Sqmm ( 2x6 sqmm ) 1100 volts grade single core FRLSH PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid concealed conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 6 Sqmm (1x6sqmm ) single core FRLSH PVC insulated unsheathed copper conductor cable as earth wire, fixed in repair, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 6 Sqmm (2x6sqmm ) ,one run of 6 Sqmm (1x6 sqmm ) cable and one metre of conduit will be measured as one unit.
Sub main wiring with two runs of 10 Sqmm ( 2x10 sqmm ) 1100 volts grade single core FRLSH PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid concealed conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 10 Sqmm (1x10sqmm ) single core FRLSH PVC insulated unsheathed copper conductor cable as earth wire, fixed in repair, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 10 Sqmm (2x10sqmm ) ,one run of 10 Sqmm (1x10 sqmm ) cable and one metre of conduit will be measured as one unit.
Supply and fixing sheet metal enclosures for DBs when MCCBs to be used double door DB VTPN 6 ways 415 volts with 250 Amps rated bus bar and neutral link including chases wall for fixing DB and making good disturbed wall surface to match with existing specifications, fixed in repair, complete all as specified and directed by Engr-in-Charge. (Including all PCC & cementing work for installation of TPN DB to wall ).
Supply and fixing sheet metal enclosures for DBs when MCCBs to be used double door DB VTPN 4 ways 415 volts with 250 Amps rated bus bar and neutral link including chases wall for fixing DB and making good disturbed wall surface to match with existing specifications, fixed in repair, complete all as specified and directed by Engr-in-Charge. (Including all PCC & cementing work for installation of TPN DB to wall ).
MCCB 4 pole, 415 volts, 250 Amps with breaking capacity 25 KA complete, therminal adjustable type, fixed in repair, complete all as specified and directed by Engr-in-Charge
MCCB 4 pole, 415 volts 100 Amps with breaking capacity 16 KA, fixed in repair, complete all as specified and as directed by Engineer-in-Charge.
Sheet metal enclosures for distribution board when MCB to be used SPN 8 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications ,fixing in repairs complete all as specified and as directed by Engr-in-Charge.
Sheet metal enclosures for distribution board when MCB to be used SPN 12 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications ,fixing in repairs complete all as specified and as directed by Engr-in-Charge.
MCB SPN, 32 to 63 Amps,240 Volts, rupturing capacity 10 KA "C" Curve including providing aluminuium thimbles for outgoing cable, fixed in repair complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
MCB SP, 6 to 32 Amps,240 Volts, rupturing capacity 10 KA "C" Series including providing aluminuium thimbles for outgoing cable, fixed in repair complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
MCB SP, 40 to 63 Amps, 240 Volts, rupturing capacity 10 KA "C" Series including providing aluminuium thimbles for outgoing cable, fixed in repair complete all as specified and as directed by Engr-in-Charge.
Supply and fix sheet metal enclosure Single pole & neutral with 2 pin and earth plug and socket 20Amps, 240V complete with one single pole MCB of any cap from 5 to 32 Amps of breaking capacity 10KA, complete all as specified and as directed by Engr-in-Charge.
M&L for providing earthing in repair complete with Copper earth plate electrode 600 x 600 x 3.15 mm buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the earth plate not less than 1.5 M below ground level connected to Copper strip 20 x 3mm thick for earthing lead fixed by means of nuts,bolt,washers etc connected to earth test point complete all as specified in electrical plate No 3 of SSR-2009 part 1, including necessary excavation and earth work in any type of soil, comman salt, charcoal dust, 40 mm dia light grade GI pipe for protection to earth lead, GI water pipe 20mm dia with funnel &wire mesh, PCC pit with CI cover and frame etc complete all as specified and directed by Engr-in-Charge. Note: - (i) All the joints shall be made with welding to get proper conductivity. (ii) On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge.
M&L for Cutting of hard standing not exceeding 45 Cm defth, and not exceeding 30 Cm width for taking out/laying UG Cable including making good disturbed surface as per existing, complete all as specified and directed by the Engr-in-Charge.
Supply, laying and testing of XLPE insulated sheathed armoured heavy duty LT 1100 Volts grade cable with aluminum conductors laid in trenches/pipe, fixed to poles, walls of size 70 sqmm 3.5 core, fixed in repair complete all as specified and as directed by Engr-in-Charge.
Supply, laying and testing of XLPE insulated sheathed armoured heavy duty LT 1100 Volts grade cable with aluminum conductors laid in trenches/pipe, fixed to poles, walls of size 35 sqmm 3.5 core, fixed in repair complete all as specified and as directed by Engr-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. n exc 10 sq m on plan and n exc 1.5 m in any type of soil, complete all as specified and as directed by Engr-in-Charge.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and as directed by Engr-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed by Engr-in-Charge.
Dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable, punned to 18 cm thick complete all as specified and as directed by Engr-in-Charge. NOTE Only punned thickness shall be measured for payment purpose.
Sub class ‘B’ old size well burnt bricks, laid flat in trenches as protection to cable, complete all as specified and as directed by Engr-in-Charge.
Supply and Fixing GI tubing light grade 40mm dia along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles complete all as specified and as directed by Engr-in-Charge.
Alishan Builders
SHIVAE CONSTRUCTION
MADAN LAL SHARMA AND SONS
kerni electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .