| 1 | L1₹9.0 LAccepted-AOC NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹10.8 L+₹1.6 L (17.5%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹11.1 L+₹1.9 L (20.6%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹11.5 L+₹2.3 L (25.4%)Rejected-Finance | L4 | Rejected-Finance NOT BEING LOWEST |
Tender Value
Refer Docs
EMD Value
₹18,700
Closing Date
3 Apr 2023, 5:00 pmClosed
AGE I AF CHIMNEY HILLS BANGALORE
AGE I AF CHIMNEY HILLS CHICKABANAVARA BANGALORE 560090
Speial repair to DG Sets and connected electrical works electric Chimneys at all messes at 2 AFSB Mysore
2023_MES_585731_1
8595/E8
Open Tender
Civil Works
Item Rate
120 days
AGE I AF CHIMNEY HILLS BANGALORE
As per tender document
8 documents required · 8 mandatory
₹500
Yes
AGE I AF CHIMNEY HILLS BANGALORE
₹18,700
Yes
28 Aug 2023
14 Mar 2023
5 Apr 2023
14 Mar 2023
3 Apr 2023
20 Mar 2023
14 Mar 2023 - 17 Mar 2023
Amount
Dismentlling of alternator from engine of 100 KVA DG set Transportation to workshop, Rewinding with suitable size of copper conductor and Refixing at same location and Testing complete
Supply and Fix Contactor coil LXI FF, 240 volts for AMF Panel
Supply and Fix of AVR for DG Set 100 KVA/ 62.5 KVA/ 82.5 KVA
Dismentling of old unserviceable radiator assembly and Supply, Fix and testing of radiator assembly for 30 KVA DG Set
Dismentling of old unserviceable radiator assembly and Supply, Fix and testing of radiator assembly for 82.5 KVA DG Set
Disconnecting of old unserviceable 12 Pin terminal block for battery charger and connect new 12 pin terminal block.
Taking out old unserviceable Contactors, Connectors, Relays and fixing new Contactors, connectors and relays in AMF Panel for 20 KVA DG set at PH
Supply and Fix in repair Change Over on load Change over switch 250 Amps, Four pole
Supply and Fix in repair Change Over on load Change over switch 160 Amps, Four pole
Supply and Fix in repair Change Over on load Change over switch 100 Amps, Four pole
Supply and Fix Relay for 100 KVA DG Set
Supply and Fix Contactor LC1F3304 for AMF Panel
Supply and connect battery charger
Supply and connect battery 100 Ah
Supply and connect battery 150 Ah
Supply and connect battery 88 Ah
Repair of Control panel and AMF Panel of DG Set
Excavation in trenches n.exc 1.5 Mtr wide and n.exc 1.5Mtr depth and getting out for errection of LT poles, stay assembly and laying of cable etc in hard/dense soil complete all as specified and directed by Engineer-in-Charge
M&L for laying of bricks well burnt sub class ‘B’ (old pattern) laid flat for cable protection width equal to the length of brick complete all as specified .
M&L for sand cushioning in trenches spreading and consolidation 8cm thick before laying the cable & 15 cm of sand after laying the cable complete all as specified
Removing of excavated material to a distance n.exc 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed by Engineer-in-Charge
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cms. thick in hard/dense soil complete all as specified and directed by Engineer-in-Charge
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 16 Sqmm, 2 core
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 16 Sqmm, 4 core
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 25 Sqmm, 4 core
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 150 Sqmm, 4 core
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 120 Sqmm, 3.5 core
Disconnecting of ACB 630 Amp and complete servicing including replacement of unserviceable components and refixing the same after repair and testing complete.
Supply and Fix MCCB 160 Amps, 415 Volts, FP
Supply and Fix MCCB 125 Amps, 415 Volts, FP
Supply and Fix MCCB 100 Amps, 415 Volts, FP
Supply and Fix MCCB 63 Amps, 415 Volts, FP
Dismentling Complete industrial Chimney from site including Duct, Filters and blower motor and exhaust system of Candidate Mess and refixing the same after cleaning and servicing
Cleaning suction system and change the filters304 grade
Rewinding of 3 Phase, 3 HP motor
Supply and fix of Motor starter of 3 HP motor
Dismentling Complete industrial Chimney from site including Duct, Filters and blower motor and exhaust system of Airmen Mess and SNCO's Mess and refixing the same after cleaning and servicing
Cleaning suction system and change the filters304 grade
Cleaning and rewinding of exhaust Fan
SRI AYYAPPA ENTERPRISES
SAPTHAGIRI CONSTRUCTIONS
eurekaenterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .