Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC | L1 | Accepted-AOC SINCE L1 BIDDER | |
| 2 | L2₹19.9 L+₹26,085 (1.33%)Rejected-Finance 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L2 | Rejected-Finance SINCE NOT L1 BIDDER | |
| 3 | L3₹20.8 L+₹1.1 L (5.55%)Rejected-Finance | L3 | Rejected-Finance SINCE NOT L1 BIDDER | |
| 4 | L4₹20.9 L+₹1.2 L (6.22%)Rejected-Finance | L4 | Rejected-Finance SINCE NOT L1 BIDDER | |
| 5 | L5₹22.0 L+₹2.3 L (11.9%)Rejected-Finance | L5 | Rejected-Finance SINCE NOT L1 BIDDER |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
25 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AMRITSAR CANTT
HQ CWE ASR OLD CANTT
ADDN / ALTN WKS TO BLDG NO P-38 AND P-39 OF ASC SUPPLY TYPE C AT NAMS UNDER GE NAMS
2024_MES_638578_2
CWE/ASR-58/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE NAMS
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE NAMS
₹54,000
Yes
25 Apr 2024
5 Mar 2024
27 Mar 2024
5 Mar 2024
25 Mar 2024
12 Mar 2024
Amount
Material and labour for cutting openings, through brick walls built in cement mortar for door, window and other openings or enlarging existing openings converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc. to store and removing rubbish not exc. 50m complete, all as specified and directed.
Taking down aluminium Chowkats or frames from the opening of size exceeding 1.5 Sqm but n exc 4 Sqm each with shutters ( without taking off shutters from the frames) complete, all as specified and directed.
Taking down steel window of any size n exc 1.50 Sqm each ( without taking off shutters from the frames) complete, all as specified and directed.
Taking down steel ventilator of size n exc 1.50 Sqm each ( without taking off shutters from the frames) complete, all as specified and directed.
Taking down steel rolling shutter of size exc 2.0 sqm each of any description complete, all as specified and directed.
Dismantling of brickwork, built in cement mortar including all quoins, arches, pillars, etc. complete, all as specified and directed.
Material and labour for brick work with sub class 'B' bricks straight curved on plan exc 6 mean radius built in cement mortar 1:6 complete, all as specified and directed.
All as per Srl item No 07 above but except bricks (old dismantled serviceable bricks obtained from Item No 06 to be used) complete, all as specified and directed.
Taking down cement plaster of any description on brick walls, etc including raking out joints, hacking for key scrubbing down with water etc complete, all as specified and directed.
Material and labour for rendering 15 mm thick on fair faces of brick work or concrete surfaces on walls in CM 1:6. finishing even and smooth without using extra cement complete, all as specified and directed.
Material and labour for rendering 15 mm thick on fair faces of brick work or concrete surfaces on walls in cement mortar 1:4. finishingb the surfaces even and fair without using extra cement complete, all as specified and directed.
Material and labour for preparation of new surface and applying two coats of oil bound distemper on walls including one coat of primer complete, all as specified and directed.
Material and labour for preparation / complete removal of existiong treatment of old decorated surfaces plastered or un plastered of walls and applying one coat of oil bound distemper on wall . complete removal of existing treatment complete, all as specified and directed.
Material and labour for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance dirt resistance exterior paint of required shade company depot tinted with silicon additives @ 1.43 litre/10sqm over and including priming coat of exterior primer applied @ 0.90 litre / 10sqm over new surface/ after prepairing old surface complete, all as specified and directed.
Material and labour for preparation new /old surfaces plastered or un plastered of ceiling and applying one coat of oil bound distemper on ceiling . complete, all as specified and directed.
Supply and fix powder coated aluminium frame for doors ,windows, ventilators with one or more rebates including joining cleats for fixing complete, all as specified and directed. ( Minimum thickness of powder coating 50 micron)
Supply and fixing aluminium powder coated shutter(for doors) wighing 0.55 kg/m including necessary joining cleats,glazing clips, rubber beading with neoprene packing anodized handle 2 numbers in each, locking arrangement (mortised) and aluminuium anodised tower bolt 200 mm long aluminium snap beading screws etc. complete, all as specified and directed.
Supply and fixing aluminium powder coated shutter(for window and ventilator) side hung type without sash, aluminium section wighing 0.55 kg/m including necessary jointing cleats,glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fitting such as peg stays 150mm long (1 no.) hinges type B-21 100mm long( 2 no) suitable handle (1 no) complete, all as specified and directed.
Supply and fix Sheet glass, 5.5mm thick ordinary quality, in squares,exceeding 0.50 sqm in each pane including rubber packing and aluminium beading with and including solar control film 25 Micron reflective type sticked to glass panes as per instructions of manufacturer complete, all as specified and directed.
Material and labour for Vitrified tiles,dark shade 10mm thick (Square/ rectangular) polished, area of each tiles n.exc 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6.including dismantling existing treatment or roughening the surface by hacking/punching complete, all as specified and directed.
Material and labour for providing and fixing Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre and to centre and Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I.flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
Material and labour for providing and fixing of gypsum board 12mm thick on ceiling fixed with screws as per manufacturer is instructions complete, all as specified and directed.
Supply and fixing hollow PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on and including PVC frame as per manufacturer's specifications complete, all as specified and directed.
Material and labour for applying 2mm thick wall care putty on ceiling complete, all as specified and directed.
M&L for Machine pressed coloured precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and no pigments over and including 25mm thick sand cushioning 75mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) in sub base of floor complete all as specified and directed.make
Surface excavation n exc 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete, all as specified and directed.
Material and labour Hardcore of broken bricks, gauge n exc. 63 mm, deposited , spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete, all as specified and directed.
Supply and fixing of MS framed work as in framed for cladding,glazing etc of angle or other section with gusset plates, rail, braces,etc and similar work including primer conform-ing to Fe-290 (Gde E-165) complete, all as specified and directed.
Material and labour for RCC nominal mix type B-1 (1:2:4) (20mm graded stones aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete, all as specified and directed.
Material and labour for form work to fair finished flat surfaces of sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilever,shelves, including supports, overhangs etc also splays between floors and beams etc complete, all as specified and directed.
Supply and fixing mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or scouring with clips complete, all as specified and directed.
Supply and fixing mild steel TMT bars 5 mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required, including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or scouring with clips complete, all as specified and directed.
Material and labour two coats of synthetic enamel paint over a priming coat of red oxide including prepration of surfaces on steel surfaces of any description over 10 cm in width or girth not otherwise described complete, all as specified and directed.
Material and labour of Wiring complete with 1.5 sqmm single core PVC insulated unsheathed cable 1100 volts grade, multistranded with copper conductors conforming to IS specifications, drawn through and including conceled conduit concealed/ fixed on wall / ceiling with suitable clamps, screws, etc or concealed in wall including terminal boxes fabricated with 1.6 mm MS sheet concealed in walls covered with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch sockets outlets, fan regulators, etc, including provn of 1.5 sqmm PVC insulated unsheathed cable with multistranded copper conductor as earth continuity conductor and connecting to common earth dolly complete, all as specified and directed. :-
One light point/Bell/Fan point controlled by one switch.
One socket outlet 5 pin 6 Amp controlled by one, one way switch on same board.
One socket outlet 5 pin 6 Amp controlled by one, one way switch on independent board.
All as per item No. 30 here-in-before but wiring with using cable 2.5 sqmm size copper wire (FR) and earth wire of PVC insulated (Green colour) 2.5 Sqmm size copper wire for one 6 pin socket outlet, 16 Amp on independent board complete, all as specified and directed.
Supply and fix switch piano one way 6 Amp, SP, 230 Volts complete, all as specified and directed.
Supply and fix stepped type electronic fan regulator, flush type, complete, all as specified and directed.
Supply and fixing ceiling rose surface bakelite 3 terminals 65x32mm complete, all as specified and directed.
Supply and fixing Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant/batten fittings including LED bulb 9 Watt, 230 Volt complete, all as specified and directed.
Supply and fixing LED 2 X 2 ultra slip recess mounted luminaire with high brightness 36 Watt LED package and Unique pattern acrylic de-glaring diffuser sheet for glare-free uniform light distribution suitable for ceiling icluding making electrical connections complete, all as specified and directed.
Supply and fix wall/ceing mounting LED 18 Watt PC Diffuser tube light fitting complet with all aceesories 1x18W LED suitable for domestic application 240Volts 50HZ including one tube rode and internally pre-wired with 1.5 sqmm twin twisted flexible copper conductor and complete, all as specified and directed.
Material and labour for sub main wiring with PVC insulated, 1100 volts grade single core multistranded copper conductor cable conforming to IS specifications, 2 runs of 6 sqmm including 1 run of 6 sq mm single core multistranded copper conductor, PVC insulated cables as earth continuity conductor drawn through and including one run of 25 mm dia rigid PVC conduit and conduit accessories fixed on wall/ceiling etc., or concealed in wall and connecting to common earth dolly all as specified and directed including taking down all sub main wiring complete, all as specified and directed. Note : 2 Run of 6 sqmm, 1 Run of 6 sq mm and 1 run of PVC conduit will be measured as 1 unit.
Supply and fixing Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 8 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete, all as specified and directed. (Note : cost of removing old wooden box and making good of surface as original by brick work, plastering, whitewash/colour/distemper etc is included in quoted rate)
Supply and fixing Bus bar chamber made out of from CRCA sheet 2 mm thick including making concealed in the wall with nuts and bolts and color wash to match with exsting, powder coated of size 600 x450 x 150 mm in IP-65 consisting of the following :- (a) Incoming MCCB 100 Amp 4 pole 16 KA, 415 V- 01 No (b) Outgoing Alluminium Bus bar duly insualted RBY and Black- 01 Set (c) Led indicator RYB = 01 Set
Supply and fixing in repair MCB SPN, 240 volts, 40 to 63 Amp, rupturing capacity 10 KA, ‘B’ curve type complete, all as specified and directed.
Supply and fixing in repair MCB single pole, 240 volts, 6 to 32 Amp, rupturing capacity 10 KA, ‘B’ curve type complete, all as specified and directed.
Supply and fixing in repair MCB, single pole, 240 volts, 40 to 63 Amp, rupturing capacity 10 KA, ‘B’ curve type complete, all as specified and directed.
Supply and Fixing metal enclosure (plug & socket type DB) complete including single pole and neutral enclosure with two pin, earth plug and socket complete with one SP MCB, C Curve type of capacity 20 Amp, 10 KA complete, all as specified and directed.
M/s Vijay Construction Co.
tarvinder singh
Santokh Singh and Associates
tarlok singh contractor
M/s MAHAJAN CONSTRUCTION CO.
Sachdeva Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .